The DOE Advanced Gas Reactor Fuel Development and Qualification Program
No abstract prepared.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
Ti-6Al-4V is the most studied alloy via electron beam melting (EBM) with regards to microstructure and mechanical behavior, but there have been no attempts to correlate in situ porosity detection and fatigue behavior. This is required for widespread adoption of EBM because conventional evaluation is often time-consuming and expensive. This study presents the use of near-infrared imaging to detect and quantify porosity in Ti-6Al-4V builds fabricated from different powder feedstocks and its correlation to their fatigue response. Finally, we report that, for identical processing parameters, the variability in powder feedstock causes variations in porosity and scatter in the respective fatigue response.
No abstract prepared.
The continuously growing demand for batteries used within automotive, aviation, and grid applications has exacerbated the need to supplement critical battery material feedstocks, such as those for anode and cathode active materials. New or supplementary material sources, however, universally comprise unique material properties that can significantly affect the lifetime and performance of resultant batteries. As such, the influence of composition, microstructure, and morphology on electrochemical performance should be characterized quickly and accurately to accelerate commercialization of new material sources. This work introduces a tiered framework to quickly assess new material viability and understand the influence of physicochemical properties on battery performance. The Tier 1 testing described here is rapid and lower-effort to quickly recognize materials with fundamental flaws and potentially disqualify them. Later testing would require more time and effort but provide higher fidelity information with a goal of validating materials for specific applications. A case study examining various commercial sources of LiFePO4 (LFP) is presented, using Tier 1 of the protocol to identify rapid electrochemical and physicochemical signals that correlate with performance and to provide early go/no-go decisions on LFP materials without the need for long-term cycling data.
Two modeling tools, a thermohydraulics code and a computational model in COMSOL Multiphysics, have been developed, tested and then applied to the analysis of fluid flow and heat transfer in a thermal convection loop (TCL). Such a device has recently been used to experimentally evaluate corrosion compatibility of APMT (Fe–21Cr–5Al–3Mo) steel with high-temperature molten eutectic lead-lithium (PbLi) alloy at Oak Ridge National Lab, TN, USA. Here, the 1-D thermohydraulics code allows for rapid calculations of the loop parameters as a function of the applied heat flux. The supplemental COMSOL finite-element computations provide detailed 3-D velocity and temperature field data but are much more time consuming. Both modelling tools demonstrate an excellent agreement in the computed circulation velocity as well as maximum and minimum temperatures. The performed TCL analysis focuses on flow development in the “hot” and “cold” legs, formation of Dean vortices in corner regions, blocking effect of the immersed samples, and radiative and convective cooling effects under the experiment-relevant conditions for Prandtl number Pr = 0.015, Grashof numbers Gr ~10 7 , and Reynolds numbers Re ~10 4 .
Several high-purity 233 U items potentially useful as isotope dilution mass spectrometry standards for safeguards, non-proliferation, and nuclear forensics measurements are identified and rescued from downblending. By preserving the supply of 233 U materials of different pedigree for use as source materials for certified reference materials (CRMs), it is ensured that the safeguards community has high quality uranium isotopic standards required for calibration of the analytical instruments. One of the items identified as a source material for a high-purity CRM is characterized for the uranium isotope-amount ratios using thermal ionization mass spectrometry (TIMS). Additional verification measurements on this material using quadrupole inductively coupled plasma mass spectrometry (ICPMS) are also performed. As a result, the comparison of the ICPMS uranium isotope-amount ratios with the TIMS data, with much smaller uncertainties, validated the ICPMS measurement practices. ICPMS is proposed for the initial screening of the purity of items in the rescue campaign.
Purpose: To evaluate and histologically qualify carbogen-induced ΔR{sub 2}* as a noninvasive magnetic resonance imaging biomarker of improved tumor oxygenation using a double 2-nitroimidazole hypoxia marker approach. Methods and Materials: Multigradient echo images were acquired from mice bearing GH3 prolactinomas, preadministered with the hypoxia marker CCI-103F, to quantify tumor R{sub 2}* during air breathing. With the mouse remaining positioned within the magnet bore, the gas supply was switched to carbogen (95% O{sub 2}, 5% CO{sub 2}), during which a second hypoxia marker, pimonidazole, was administered via an intraperitoneal line, and an additional set of identical multigradient echo images acquired to quantify any changes in tumor R{sub 2}*. Hypoxic fraction was quantified histologically using immunofluorescence detection of CCI-103F and pimonidazole adduct formation from the same whole tumor section. Carbogen-induced changes in tumor pO{sub 2} were further validated using the Oxylite fiberoptic probe. Results: Carbogen challenge significantly reduced mean tumor R{sub 2}* from 116 ± 13 s{sup −1} to 97 ± 9 s{sup −1} (P<.05). This was associated with a significantly lower pimonidazole adduct area (2.3 ± 1%), compared with CCI-103F (6.3 ± 2%) (P<.05). A significant correlation was observed between ΔR{sub 2}* and Δhypoxic fraction (r=0.55, P<.01). Mean tumor pO{sub 2} during carbogen breathing significantly increased from 6.3 ± 2.2 mm Hg to 36.0 ± 7.5 mm Hg (P<.01). Conclusions: The combined use of intrinsic susceptibility magnetic resonance imaging with a double hypoxia marker approach corroborates carbogen-induced ΔR{sub 2}* as a noninvasive imaging biomarker of increased tumor oxygenation.
Not Available
The Joint Projects under the Japan-USA Fusion Cooperation Program started in 1981 and has continued for more than 40 years. In the Joint Projects, although a wide range of fusion materials and engineering issues were covered, neutron radiation effects on fusion reactor materials have always been the major research emphases, and the neutron irradiation facilities in the US were jointly used by Japanese and US researchers. Japanese test facilities including neutron and charged particle irradiation facilities were complementarily used. Here, the initial focus of the Joint Projects was on fundamental fusion neutron radiation effects and irradiation correlation. Systematic comparison of fission and fusion radiation effects in comparable damage levels and the effects of transmutation-induced helium were investigated. The collaboration was then focused on the effect of dynamic irradiation effects in variable conditions. In addition to the relatively fundamental studies, the Joint Projects contributed largely to development of candidate materials such as RAFM steels, vanadium alloys, SiC/SiC composites, and tungsten alloys, through a mechanism-oriented approach. The Joint Projects also covered issues specific to materials application to fusion blankets and plasma-facing components, including neutron radiation effects such as tritium retention and permeation of neutron-irradiated plasma-facing materials. Various irradiation technologies were developed and applied to the irradiation experiments, including those for in-situ testing.Considering that high energy neutron sources, such as A-FNS and IFMIF-DONES, now have high viability, the research supporting the neutron source programs is essential. The knowledge obtained through the Joint Projects is valuable and should be advanced for this purpose. To this end, it is of urgent necessity to launch an international scientific program accumulating knowledge of fusion neutron radiation effects, including their fundamental aspects.
Explore the source record for details and available documents.
Not Available
Not Available
Abstract not provided.
Not provided.
We have designed, built, and successfully fielded a highly efficient and gated Bragg crystal spectrometer for x-ray Thomson scattering measurements on the National Ignition Facility (NIF). It utilizes a cylindrically curved Highly Oriented Pyrolytic Graphite crystal. Its spectral range of 7.4–10 keV is optimized for scattering experiments using a Zn He-α x-ray probe at 9.0 keV or Mo K-shell line emission around 18 keV in second diffraction order. The spectrometer has been designed as a diagnostic instrument manipulator-based instrument for the NIF target chamber at the Lawrence Livermore National Laboratory, USA. Here, we report on details of the spectrometer snout, its novel debris shield configuration and an in situ spectral calibration experiment with a Brass foil target, which demonstrated a spectral resolution of E/ΔE = 220 at 9.8 keV.