Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative phase imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Gas Hydrate Characterization in the GoM using Marine EM Methods

In spite of the importance of gas hydrate as a low-carbon fuel, a possible contributor to rapid climate change, and a significant natural hazard, our current understanding about the amount and distribution of submarine gas hydrate is somewhat poor; estimates of total volume vary by at least an order of magnitude, and commercially useful concentrations of hydrate have remained an elusive target. This is largely because conventional geophysical tools have intrinsic limitations in their ability to quantitatively image hydrate. It has long been known from well logs that gas hydrate is resistive compared to the host sediments, and electrical and electromagnetic methods have been proposed and occasionally used to image hydrates. This project seeks to expand our capabilities to use electromagnetic methods to explore for gas hydrate in the marine environment. An important basic science aspect of our work was to quantify the resistivity of pure gas hydrate as a function of temperature at seafloor pressures. We designed, constructed, and tested a highpressure cell in which hydrate could be synthesized and then subjected to electrical conductivity measurements. Impedance spectroscopy at frequencies between 20 Hz and 2 MHz was used to separate the effect of the blocking electrodes from the intrinsic conductivity of the hydrate. We obtained very reproducible results that showed that pure methane hydrate was several times more resistive than the water ice that seeded the synthesis, 20,000 {Ohm}m at 0{degrees} C, and that the activation energy is 30.6 kJ/mol over the temperature range of -15 to 15{degrees} C. Adding silica sand to the hydrate, however, showed that the addition of the extra phase caused the conductivity of the assemblage to increase in a counterintuitive way. The fact that the increased conductivity collapsed after a percolation threshold was reached, and that the addition of glass beads does not produce a similar increase in conductivity, together suggest that while the surface of the gas hydrate grains are not intrinsically conductive, the presence of sand does increase their conductivity. In the field component of this project, we carried out an 18day cruise on the R.V. Roger Revelle in the Gulf of Mexico from 7th-26th October 2008 to collect controlled-source electromagnetic (CSEM) data over four hydrate prospects; blocks AC 818, WR 313, GC 955, and MC 118. During these surveys we deployed 30 ocean bottom electromagnetic (OBEM) recorders a total of 94 times at four survey areas and towed the Scripps Undersea Electromagnetic Source Instrument (SUESI) a total of 103 hours. SUESI transmission was 200 A on a 50 m dipole antenna at heights of 70-100 m above the seafloor. We also towed a neutrally buoyant 3-axis electric field recorder behind the SUESI antenna at a constant offset of 300 m. The use of a towed receiver that is "flown" above the seafloor allowed us to operate in areas where seafloor infrastructure such as wellheads, pipelines, and installed scientific equipment existed. We reduced the data to apparent resistivity psuedosections. The most compelling results come from the hydrate observatory at MC 118, where a localized resistivity anomaly is clearly identified under the southeast crater in an otherwise uniform 1 {Ohm}m background. The data from MC 118 also show that authigenic carbonate does not necessarily express itself as a confounding resistor, as was feared at the start of this project. While the results from the other prospects are much more complicated, the data are well correlated with known geology, and line to line agreement is good. Although these data are not amenable to 1D inversion as was initially hoped, we expect to use a newly developed 2D CSEM inversion code to continue to get useful information from this rich data set.

03 NATURAL GAS↗

Toward Relating Open- and Closed-Test Section Microphone Phased Array Aeroacoustic Measurements

Aeroacoustic measurements utilizing microphone phased arrays are becoming more commonplace in large-scale wind tunnels. However, for such costly tests it is difficult to assess the influence of a given facility's configuration on the acquired data. One such opportunity has recently arisen in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel, where the High-Lift configuration of the Common Research Model was tested in both open-jet and closed wall configurations. Acoustic data were acquired on the same model with the same specific hardware at the same Mach number; and for similar model angles of attack, array apertures, and array angles relative to the model location. Initial deconvolution comparisons using DAMAS appear poor. The closed test section results show contamination likely due to background noise and reflections. The open-jet results show severe blurring due to the decorrelation of acoustic waves passing through a turbulent free shear layer. However, accounting for image sources in the DAMAS grid reduces visual artifacts in the closed test section results, and a preliminary coherence correction technique mitigates the blurring in the open-jet results. Qualitatively, both tests identify similar source behavior. Quantitatively, summed spectra of the slat noise agree in some frequency bands but differ in others. Proposals that may mitigate the difference are given for each configuration, such as correcting for the array protective cover and applying background subtraction in the closed wall configuration, and further developing the coherence loss correction for deconvolution methods in the open-jet setup.

microphone array↗

Smooth Pursuit of a Partially Occluded Object

There has long been qualitative evidence that humans can pursue an object defined only by the motion of its parts. We explored this quantitatively using an occluded diamond stimulus. Four subjects (one naive) tracked a line-figure diamond moving along an elliptical path (0.9 Hz) either clockwise (CW) or counterclockwise (CCW) behind either an X-shaped aperture (CROSS) or two vertical rectangular apertures (BARS), which obscured the corners. Although the stimulus consisted of only four line segments (108 cd/square m) moving within a visible aperture (0.2 cd/square m) behind a foreground (38 cd/square m), it is largely perceived as a coherently moving diamond. The inter-saccadic portions of eye-position traces were fit with sinusoids. All subjects tracked object motion with considerable temporal accuracy. The mean phase lag was 5 deg/6 deg (CROSS/BARS) and the mean relative phase between the horizontal and vertical components was +95 deg/+92 deg (CW) and -85 deg/-75 deg (CCW), which is close to perfect. Furthermore, a chi-square analysis showed that 56% of BARS trials were consistent with tracking the correct elliptical shape (p is less than 0.05), although segment motion was purely vertical. These data disprove the main tenet of most models of pursuit: that it is a system that seeks to minimize retinal image motion through negative feedback. Rather, the main drive must be a visual signal which has already integrated spatiotemporal retinal information into an object-motion signal.

Stone, L. S.↗

Derivation of A Representative Elementary Volume (REV) for Upscaled Two-Phase Flow in Porous Media

Relative permeability plays an important role in the upscaling of multiphase flow in porous media from the pore scale to the Darcy scale. The entire concept of relative permeability is contingent on the existence of a representative elementary volume (REV). As we move to smaller samples to measure relative permeability, such as with digital core analysis, the concept of a classical REV has become increasingly unlikely when using the conventional approach to defining a representative volume. The “‘conventional”’ understanding of an REV is that a large enough volume must be considered such that spatial variability averages out. In digital rock methods, such as pore-scale simulations based on micro-computed tomography (CT) images, the domain size is typically 2 to 4 mm. This is approximately the length scale of a single-phase flow REV using the classic REV approach. However, the single-phase perspective does not consider the complex dynamics and fluctuations often observed in multiphase flow systems, even at centimeter-scale experiments and/or simulations. A fundamental question is, therefore, whether the domain size commonly used in digital rock simulations can provide a consistent energy budget such that the concept of relative permeability exists. Based on first principles, relative permeability accounts for the rate of energy dissipated in a stationary process. If the dynamics are fluctuating, the energy dissipated can vary but will average out over a long enough timescale. The key to determining the validity of the relative permeability is the timescale of the measurement, not the spatial scale. The conventional REV theory assumes that spatial, temporal, and ensemble averages are equivalent in an ergodic system, but it does not provide a way to test this assumption. We provide a formal way to identify the timescale where the relative permeability accurately captures energy dissipation as a way to validate relative permeability measurements and quantitatively assess their accuracy. This result will be tested for a practical SCAL test, determining how long a flow experiment needs to be run to accurately characterize the rate of energy dissipation by the flow. The outcome will be a best practice guide for the determination of relative permeability from core-scale experiments and/or digital core simulations that ensure the energy budget is fully accounted for in the relative permeability coefficient.

Mcclure, James [Virginia Tech, Blacksburg]↗

THE BULGELESS SEYFERT/LINER GALAXY NGC 3367: DISK, BAR, LOPSIDEDNESS, AND ENVIRONMENT

NGC 3367 is a nearby isolated active galaxy that shows a radio jet, a strong bar, and evidence of lopsidedness. We present a quantitative analysis of the stellar and gaseous structure of the galaxy disk and search for evidence of recent interaction. Our study is based on new UBVRI H{alpha} and JHK images and on archive H{alpha} Fabry-Perot and H I Very Large Array data. From a coupled one-dimensional/two-dimensional GALFIT bulge/bar/disk decomposition a (B/D {approx} 0.07-0.1) exponential pseudobulge is inferred in all the observed bands. A near-infrared (NIR) estimate of the bar strength Q{sup max}{sub T}(R) = 0.44 places NGC 3367 bar among the strongest ones. The asymmetry properties were studied using (1) the optical and NIR concentration-asymmetry-clumpiness indices, (2) the stellar (NIR) and gaseous (H{alpha}, H I) A{sub 1} Fourier mode amplitudes, and (3) the H I-integrated profile and H I mean intensity distribution. While the average stellar component shows asymmetry values close to the average found in the local universe for isolated galaxies, the young stellar component and gas values are largely decoupled showing significantly larger A{sub 1} mode amplitudes suggesting that the gas has been recently perturbed and placing NGC 3367 in a global starburst phase. NGC 3367 is devoid of H I gas in the central regions where a significant amount of molecular CO gas exists instead. Our search for (1) faint stellar structures in the outer regions (up to {mu}{sub R} {approx} 26 mag arcsec{sup -2}), (2) (H{alpha}) star-forming satellite galaxies, and (3) regions with different colors (stellar populations) along the disk all failed. Such an absence is interpreted by using results from recent numerical simulations to constrain either a possible tidal event with an LMC like galaxy to some dynamical times in the past or a very low mass but perhaps gas rich recent encounter. We conclude that a cold flow accretion mode (gas and small/dark galaxies) may be responsible for the nuclear activity and peculiar (young stars and gas) morphology regardless of the highly isolated environment. Black hole growth in bulgeless galaxies may be triggered by smooth mass accretion.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase retrieval using polychromatic illumination for transmission X-ray microscopy

An alternative method for quantitative phase retrieval in a transmission X-ray microscope system at sub-50-nm resolution is presented. As an alternative to moving the sample in the beam direction in order to analyze the propagation-introduced phase effect, we have illuminated the TXM using X-rays of different energy without any motor movement in the TXM system. Both theoretical analysis and experimental studies have confirmed the feasibility and the advantage of our method, because energy tuning can be performed with very high energy resolution using a double crystal monochromator at a synchrotron beam line, and there is zero motor error in TXM system in our approach. High-spatial-resolution phase retrieval is accomplished using the proposed method.

47 OTHER INSTRUMENTATION↗

SU-F-J-76: Evaluation of the Performance of Different Deformable Image Registration Algorithms in Helical, Axial and Cone-Beam CT Images of a Mobile Phantom

Purpose: To investigate quantitatively the performance of different deformable-image-registration algorithms (DIR) with helical (HCT), axial (ACT) and cone-beam CT (CBCT) by evaluating the variations in the CT-numbers and lengths of targets moving with controlled motion-patterns. Methods: Four DIR-algorithms including demons, fast-demons, Horn-Schunk and Locas-Kanade from the DIRART-software are used to register CT-images of a mobile-phantom. A mobile-phantom is scanned with different imaging techniques that include helical, axial and cone-beam CT. The phantom includes three targets with different lengths that are made from water-equivalent material and inserted in low-density-foam which is moved with adjustable motion-amplitudes and frequencies. Results: Most of the DIR-algorithms are able to produce the lengths of the stationary-targets, however, they do not produce the CT-number values in CBCT. The image-artifacts induced by motion are more regular in CBCT imaging where the mobile-target elongation increases linearly with motion-amplitude. In ACT and HCT, the motion-artifacts are irregular where some mobile -targets are elongated or shrunk depending on the motion-phase during imaging. The DIR-algorithms are successful in deforming the images of the mobile-targets to the images of the stationary-targets producing the CT-number values and length of the target for motion-amplitudes < 20 mm. Similarly in ACT, all DIR-algorithms produced the actual CT-number and length of the stationary-targets for motion-amplitudes < 15 mm. As stronger motion-artifacts are induced in HCT and ACT, DIR-algorithms fail to produce CT-values and shape of the stationary-targets and fast-demons-algorithm has worst performance. Conclusion: Most of DIR-algorithms produce the CT-number values and lengths of the stationary-targets in HCT and ACT images that has motion-artifacts induced by small motion-amplitudes. As motion-amplitudes increase, the DIR-algorithms fail to deform mobile-target images to the stationary-images in HCT and ACT. In CBCT, DIR-algorithms are successful in producing length and shape of the stationary-targets, however, they fail to produce the accurate CT-number level.

60 APPLIED LIFE SCIENCES↗

Correlation between human observer performance and model observer performance in differential phase contrast CT

Purpose: With the recently expanding interest and developments in x-ray differential phase contrast CT (DPC-CT), the evaluation of its task-specific detection performance and comparison with the corresponding absorption CT under a given radiation dose constraint become increasingly important. Mathematical model observers are often used to quantify the performance of imaging systems, but their correlations with actual human observers need to be confirmed for each new imaging method. This work is an investigation of the effects of stochastic DPC-CT noise on the correlation of detection performance between model and human observers with signal-known-exactly (SKE) detection tasks.Methods: The detectabilities of different objects (five disks with different diameters and two breast lesion masses) embedded in an experimental DPC-CT noise background were assessed using both model and human observers. The detectability of the disk and lesion signals was then measured using five types of model observers including the prewhitening ideal observer, the nonprewhitening (NPW) observer, the nonprewhitening observer with eye filter and internal noise (NPWEi), the prewhitening observer with eye filter and internal noise (PWEi), and the channelized Hotelling observer (CHO). The same objects were also evaluated by four human observers using the two-alternative forced choice method. The results from the model observer experiment were quantitatively compared to the human observer results to assess the correlation between the two techniques.Results: The contrast-to-detail (CD) curve generated by the human observers for the disk-detection experiments shows that the required contrast to detect a disk is inversely proportional to the square root of the disk size. Based on the CD curves, the ideal and NPW observers tend to systematically overestimate the performance of the human observers. The NPWEi and PWEi observers did not predict human performance well either, as the slopes of their CD curves tended to be steeper. The CHO generated the best quantitative agreement with human observers with its CD curve overlapping with that of human observer. Statistical equivalence between CHO and humans can be claimed within 11% of the human observer results, including both the disk and lesion detection experiments.Conclusions: The model observer method can be used to accurately represent human observer performance with the stochastic DPC-CT noise for SKE tasks with sizes ranging from 8 to 128 pixels. The incorporation of the anatomical noise remains to be studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-219: Quantitative Evaluation of Motion Effects On Accuracy of Image-Guided Radiotherapy with Fiducial Markers Using CT Imaging

Purpose: To investigate quantitatively patient motion effects on the localization accuracy of image-guided radiation with fiducial markers using axial CT (ACT), helical CT (HCT) and cone-beam CT (CBCT) using modeling and experimental phantom studies. Methods: Markers with different lengths (2.5 mm, 5 mm, 10 mm, and 20 mm) were inserted in a mobile thorax phantom which was imaged using ACT, HCT and CBCT. The phantom moved with sinusoidal motion with amplitudes ranging 0–20 mm and a frequency of 15 cycles-per-minute. Three parameters that include: apparent marker lengths, center position and distance between the centers of the markers were measured in the different CT images of the mobile phantom. A motion mathematical model was derived to predict the variations in the previous three parameters and their dependence on the motion in the different imaging modalities. Results: In CBCT, the measured marker lengths increased linearly with increase in motion amplitude. For example, the apparent length of the 10 mm marker was about 20 mm when phantom moved with amplitude of 5 mm. Although the markers have elongated, the center position and the distance between markers remained at the same position for different motion amplitudes in CBCT. These parameters were not affected by motion frequency and phase in CBCT. In HCT and ACT, the measured marker length, center and distance between markers varied irregularly with motion parameters. The apparent lengths of the markers varied with inverse of the phantom velocity which depends on motion frequency and phase. Similarly the center position and distance between markers varied inversely with phantom speed. Conclusion: Motion may lead to variations in maker length, center position and distance between markers using CT imaging. These effects should be considered in patient setup using image-guided radiation therapy based on fiducial markers matching using 2D-radiographs or volumetric CT imaging.

60 APPLIED LIFE SCIENCES↗

Can MRI be used to diagnose histologic grade in T1a (< 4 cm) clear cell renal cell carcinomas?

Objective: To assess whether MRI can differentiate low-grade from high-grade T1a cc-RCC. Materials and methods: With IRB approval, 49 consecutive solid < 4 cm cc-RCC (low grade [Grade 1 or 2] N = 38, high grade [Grade 3] N = 11) with pre-operative MRI before nephrectomy were identified between 2013 and 2018. Tumor size, apparent diffusion coefficient (ADC) histogram analysis, enhancement wash-in and wash-out rates, and chemical shift signal intensity index (SI index) were assessed by a blinded radiologist. Subjectively, two blinded Radiologists also assessed for (1) microscopic fat, (2) homogeneity (5-point Likert scale), and (3) ADC signal (relative to renal cortex); discrepancies were resolved by consensus. Outcomes were studied using Chi square, multivariate analysis, logistic regression modeling, and ROC. Inter-observer agreement was assessed using Cohen’s kappa. Results: Tumor size was 24 ± 7 (13–39) mm with no association to grade (p = 0.45). Among quantitative features studied, corticomedullary phase wash-in index (p = 0.015), SI index (p = 0.137), and tenth-centile ADC (p = 0.049) were higher in low-grade tumors. 36.8% (14/38) low-grade tumors versus zero high-grade tumors demonstrated microscopic fat (p = 0.015; Kappa = 0.67). Microscopic fat was specific for low-grade disease (100.0% [71.5–100.0]) with low sensitivity (36.8% [21.8–54.6]). Other subjective features did not differ between groups (p > 0.05). A logistic regression model combining microscopic fat + wash-in index + tenth-centile-ADC yielded area under ROC curve 0.98 (Confidence Intervals 0.94–1.0) with sensitivity/specificity 87.5%/100%. Conclusion: The combination of microscopic fat, higher corticomedullary phase wash-in and higher tenth-centile ADC is highly accurate for diagnosis of low-grade disease among T1a clear cell RCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative wood–adhesive penetration with X-ray computed tomography

Micro X-ray computed tomography (XCT) was used to analyze the 3D adhesive penetration behavior of different wood–adhesive bondlines. Three adhesives, a phenol formaldehyde (PF), a polymeric diphenylmethane diisocyanate (pMDI), and a hybrid polyvinyl acetate (PVA), all tagged with iodine for enhanced X-ray attenuation, were used to prepare single-bondline laminates in two softwoods, Douglas-fir and loblolly pine, and one hardwood, a hybrid polar. Adhesive penetration depth was measured with two separate calculations, and results were compared with 2D fluorescent micrographs. A total of 54 XCT scans were collected, representing six replicates of each treatment type; each replicate, however, consisted of approximately 1500 individual, cross-section slices stacked along the specimen length. As these adhesives were highly modified, the presented results do not indicate typical behavior for their broader adhesive classes. Still, clear penetration differences were observed between each adhesive type, and between wood species bonded with both the PF and pMDI adhesives. Furthermore, penetration results depended on the calculation method used. Two adhesive types with noticeably different resin distributions in the cured bondline, showed relatively similar penetration depths when calculated with a traditional effective penetration equation. However, when the same data was calculated with a weighted penetration calculation, which accounts for both adhesive area and depth, the results appeared to better represent the different distributions depicted in the photomicrographs and tomograms. Additionally, individual replicate comparisons showed variation due to specimen anatomy, not easily observed or interpreted from 2D images. Finally, 3D views of segmented 3D adhesive phases offered unique, in-situ views of the cured adhesive structures. In particular, voids formed by CO 2 bubbles generated during pMDI cure were clearly visible in penetrated columns of the solidified adhesive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.

60 APPLIED LIFE SCIENCES↗

Fluid Dynamic Verification Experiments on STS-70

Fluid dynamic experiments were flown on STS-70 as phase two of the engineering evaluation of the first bioreactor Engineering Development Unit (EDU#1). The phase one experiments were comparative cell cultures in identical units on earth and onboard STS-70. In phase two, two types of fluid dynamic experiments were performed. Qualitative comparisons of the basic flow patterns were evaluated with the use of 'dye' streaklines formed from alternate injections of either a mild acid or base solution into the external flow loop that was then perfused into the vessel. The presence of Bromothymol Blue in the fluid then caused color changes from yellow to blue or vice versa, indicating the basic fluid motions. This reversible change could be repeated as desired. In the absence of significant density differences in the fluid, the flow patterns in space should be the same as on earth. Video tape records of the flow patterns for a wide range of operating conditions were obtained. The second type of fluid dynamic experiment was the quantitative evaluation of the trajectories of solid beads of various densities and sizes. The beads were introduced into the vessel and the paths recorded on video tape, with the vessel operated at various rotation rates and flow perfusion rates. Because of space limitations, the video camera was placed as close as possible to the vessel, resulting in significant optical distortion. This report describes the analysis methods to obtain comparisons between the in-flight fluid dynamics and numerical models of the flow field. The methods include optical corrections to the video images and calculation of the bead trajectories for given operating conditions and initial bead locations.

Kleis, Stanley J.↗

Intracranial Effects of Intermittent Lower Body Negative Pressure with Head Down Tilt Bed Rest: Comparison to Upright Posture

INTRODUCTION Spaceflight-associated neuro-ocular syndrome (SANS) affects a majority of astronauts during long-duration spaceflight. SANS is hypothesized to result from an unrelenting headward fluid shift that occurs in the microgravity environment. Altered intracranial structure and physiology documented in spaceflight and head-down tilt (HDT) experiments(1, 2) are also theorized to be related to chronic headward fluid shift and thereby can provide an independent quantitative assessment related to this mechanism. As a potential countermeasure, lower body negative pressure (LBNP) applied in the supine posture has shown efficacy in reducing headward fluid shift(3). However, it remains unknown if intermittent LBNP simulating daily upright posture fluid redistribution can mitigate SANS and intracranial changes associated with long-duration spaceflight. The goal of this study was to quantify the effects of daily application of LBNP or daily exposure to the upright posture on intracranial structure and physiology during long-term HDT in order to evaluate the potential efficacy of LBNP as a countermeasure to SANS. METHODS 22 healthy volunteers (11 men; 11 women; mean age = 35 years (SD=9.2)(age range = 24 to 52 years); mean BMI = 24.0 kg/m2 (SD=2.8)) completed an MRI study performed at the German Aerospace Facility in Cologne, Germany. Strict six-degree head-down tilt (HDT) bedrest was used as a spaceflight analog to induce a continuous headward fluid shift for 30 days. The subjects were divided equally into two groups of interventions: 1) LBNP for 3-hour sessions twice daily and 2) seated position for 3-hour sessions twice daily. Interventions were divided into morning and afternoon sessions for both groups. The LBNP intervention was maintained at 25 mmHg  2 mmHg. Pulse-gated MRI phase-contrast flow imaging was used to quantify cerebral artery stroke volume (CASV) and peak-to-peak cerebral spinal fluid (CSF) velocity (CSFVp-p) within the cerebral aqueduct. A 3D T1-MPRAGE sequence was used to quantify volumetric changes of the brain and intracranial CSF spaces using MRI Cloud software. MRI acquisitions were obtained at baseline (BDC, supine posture), 15 days into HDT (HDT15), 29 days into HDT (HDT29), and 12 days after recovery (R12, supine posture). The data were analyzed by a mixed model, which included intervention, time (four nominal levels BDC, HDT15, HDT29, R12), and intervention-time interaction as the fixed effects and included subject as a random effect. RESULTS Compared to BDC there was no statistically significant difference in CASV and CSFVp-p during HDT except for CASV at HDT29 (seated group) where there was a 1.7 mL (12%) decrease (P<0.01). Compared to BDC there was a statistically significant increase in intracranial volume (ICV; ICV = white matter + gray matter + CSF) for both interventions at HDT15 (Δ13 mL, 0.9 % (LBNP group); Δ15 mL, 1.0%, (seated group)) and HDT29 (Δ19 mL, 1.2%, (LBNP group); Δ23 mL, 1.5%) (seated group)) (All Ps<.001). Compared to baseline, lateral ventricular volume increased at HDT15 (Δ0.9 mL, 5.5%) and HDT29 (Δ1.8 mL, 10%)) for LBNP only (P=.001 for each). During HDT, white matter volume remained stable compared to baseline for both interventions. There were no significant intervention effects in the overall response to HDT (All Ps >.2). CONCLUSION LBNP had a similar response to the seated posture during 29 days of HDT. Although there was an increase in ICV and lateral ventricular volume with HDT there was no change in intracranial physiological parameters with LBNP suggesting an overall diminished response to the long-term effects of HDT. The lack of any significant increase in white matter volume during HDT with LBNP suggests maintenance of cerebral interstitial fluid transport. Final conclusions are pending the data collection for the control group (no intervention) which will be completed in 2023.

Larry A Kramer↗

Corresponding Standard Reference Material Data used in Partial Least Squares Regression Models for Sugar Composition Estimates in Biomass in: Economic Impact of Yield and Composition Variation in Bioenergy Crops: Populus trichocarpa

Corresponding Standard Reference Material Data used in Partial Least Squares Regression Models for Sugar Composition Estimates in Biomass in: Economic Impact of Yield and Composition Variation in Bioenergy Crops: Populus trichocarpa (for corresponding manuscript: DOI: 10.1002/bbb.2148) PDF Files: Images of 1H NMR spectra for neutralized 2-stage acid hydrolysates of 4 NIST Standard Reference Material biomass samples (Monterey Pine 8493, Sugarcane Bagasse 8491, Wheat Straw 8494, and Eastern Cottonwood/Poplar 8492) and 2 Center for Bioenergy Innovation reference biomass samples (Poplar - Populus trichocarpa and Switchgrass - Panicum Virgatum). Suppression of the water peak was achieved using a NOESY-1D with presaturation, a recycle delay of 5 s, and a total of 64 scans. Spectra were acquired at 298 K and processed with automatic phase correction, baseline correction, and chemical shift referencing to TSP-d4. Images show all 1H data from 10 to 1ppm with inset spectra of region of interest (4.0 to 3.1 ppm). Text Files: Spectra for neutralized 2-stage acid hydrolysates of 4 NIST Standard Reference Material biomass samples (Monterey Pine 8493, Sugarcane Bagasse 8491, Wheat Straw 8494, and Eastern Cottonwood/Poplar 8492) and 2 Center for Bioenergy Innovation reference biomass samples (Poplar - Populus trichocarpa and Switchgrass - Panicum Virgatum) were converted into text files for plotting. Files contain 8192 points of raw spectral data from 12.23 to -2.78 ppm. The text file contains 4 columns of data and includes: Point number, Intensity, Hz, and ppm. Xcel Spreadsheet: HPLC measured monomeric sugar concentrations and bucketed 1H NMR data used to build monomeric sugar composition prediction models. Sugar composition in biomass determined from HPLC analyses are given in mg sugar/mg of biomass. Spectral bucketing was performed using Bruker’s AMIX software. Spectra were divided into 0.005 ppm buckets in the region of 3.10– 4.15 ppm for a total of 210 buckets. Headers for the bucketed data are the chemical shift in ppm of the center of the bucket. Bucketed data was used to build partial least squares models for subsequent predictions in The Unscrambler v. 10.5(CAMO A/S, Trondheim, Norway). The formation of methanol during hydrolysis interferes with the quantitative NMR analysis of sugars, so the methanol peak centered at 3.37 ppm and spanning four buckets (3.2925 – 3.2775 ppm) was set to zero for all spectra.

09 BIOMASS FUELS↗

CT reconstruction techniques for improved accuracy of lung CT airway measurement

Purpose: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. Methods: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12–100 mA s current–time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women’s Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. Results: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD FBP. Veo reconstructions showed slight improvement over STD FBP reconstructions (4%–9% increase in accuracy). The most improved ID and WA% measures were for the smaller airways, especially for low dose scans reconstructed at half DFOV (18 cm) with the EDGE algorithm in combination with 100% ASIR to mitigate noise. Using the BONE + ASIR at half BONE technique, measures improved by a factor of 2 over STD FBP even at a quarter of the x-ray dose. Conclusions: The flexibility of ASIR in combination with higher frequency algorithms, such as BONE, provided the greatest accuracy for conventional and low x-ray dose relative to FBP. Veo provided more modest improvement in qCT measures, likely due to its compatibility only with the smoother STD kernel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗