Search NASA⌕ Search

SEARCH · Search NASA

Results for “read performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Deep Learning for Fish Identification from Sonar Data: CRADA 481 [Abstract only]

To help solve the challenges of hydropower energy production related to the potential for eel injury and mortality from passage through hydropower turbines, we will develop a deep learning method for identifying migrating eels from imaging sonar. This project continues with a prior project conducted by the Pacific Northwest National Laboratory (PNNL) and the Electric Power Research Institute (EPRI) in FY2018-2019. The proposed method employs Convolution Neural Network (CNN), a powerful deep learning method for image classification, to distinguish between images of eels and non-eel moving objects. We propose to collect more laboratory data and add more existing field data to train a powerful deep learning model. In addition to eels and sticks as classified in previous studies, we will add images containing several non-eel fish species and macrophyte mats to the training data. A multi-class classification model will be developed to distinguish these objects. Object detection algorithm will be explored and developed to locate and identify multiple objects in each sonar frame. Motion analysis will be performed to track the movement of objects in sonar video clips. We will also improve the data conversion algorithm so that it can read in both DIDSON and ARIS (both are imaging sonars developed by Sound Metrics Corp) data files and convert them to images with comparably high resolution, regardless of the varying detection ranges in different environments. The developed algorithms will be packaged as a software with a graphic user interface. The software will be evaluated by external collaborators in the field. The developed framework can be generalized for automatic monitoring of fish passage and migration using other imaging sonars like ARIS and will benefit the design and operation of ecologically friendly hydroelectric projects. The developed wavelet and CNN model configuration parameters can potentially be transferred to lamprey detection in similar riverine environments.

13 HYDRO ENERGY↗

Demonstration program for Omega receiver prototype microcomputer data processing

The JOLT (TM) commercial microcomputer, based on the MOS Technology 6502 processor chip, for use in Omega navigation system is evaluated. A computer program was prepared in hand-assembled code to demonstrate receiver operation. The processor provides binary processing with interrupts enabled, a carriage return is given to initialize the teleprinter, and a jump is performed to enter the program loop to wait for an interrupt. The program loop operates continuously testing the interrupt flag. The interrupt routine reads the receiver status word and determines whether the current time-slot is the A slot. If so, the interrupt flag, which is also the data index pointer, is reset to zero. The status word is stored in the status buffer. If the time-slot is not A, the interrupt flag/pointer is incremented by one to index the phase and status to the proper buffer words for later use by the print routine.

Lilley, R. W.↗

Planning for execution monitoring on a planetary rover

A planetary rover will be traversing largely unknown and often unknowable terrain. In addition to geometric obstacles such as cliffs, rocks, and holes, it may also have to deal with non-geometric hazards such as soft soil and surface breakthroughs which often cannot be detected until rover is in imminent danger. Therefore, the rover must monitor its progress throughout a traverse, making sure to stay on course and to detect and act on any previously unseen hazards. Its onboard planning system must decide what sensors to monitor, what landmarks to take position readings from, and what actions to take if something should go wrong. The planning systems being developed for the Pathfinder Planetary Rover to perform these execution monitoring tasks are discussed. This system includes a network of planners to perform path planning, expectation generation, path analysis, sensor and reaction selection, and resource allocation.

Gat, Erann↗

Digital Mid-Wavelength and Long-Wavelength Infrared Focal Planes for SmallSat Applications

In this presentation, we will report our recent efforts in achieving high performance in Antimonides type-II superlattice (T2SL) based infrared photodetectors using the barrier infrared detector (BIRD) architecture. The high operating temperature (HOT) BIRD focal plane arrays (FPAs) offer the same high performance, uniformity, operability, manufacturability, and affordability advantages as InSb. However, mid-wavelength infrared (MWIR) HOT-BIRD FPAs can operate at significantly higher temperatures (>150K) than InSb FPAs (typically 80K). Moreover, while InSb has a fixed cutoff wavelength (~5.4 µm), the HOT-BIRD offers a continuous adjustable cutoff wavelength, ranging from ~4 µm to >15 µm, and is therefore also suitable for long wavelength infrared (LWIR) as well. The LWIR detectors based on the BIRD architecture has also demonstrated significant operating temperature advantages over those based on traditional p-n junction designs. Two 6U SmalSat missions CIRAS (Cubesat Infrared Atmospheric Sounder) and HyTI (Hyperspectral Thermal Imager) are based on JPL’s T2SL BIRD focal plane arrays (FPAs). Based on III-V compound semiconductors, the BIRD FPAs offer a breakthrough solution for the realization of low cost (high yield), high-performance FPAs with excellent uniformity and pixel-to-pixel operability. Furthermore, we will discuss the advantages of the utilization of all digital read out integrated circuits with HOT-BIRDs.

Pagano, Thomas↗

Spectroscopic Signature of a Ubiquitous Metal Binding Site in the Metallo-beta-lactamase Superfamily

The metallo-{beta}-lactamase (M{beta}L) superfamily is a functionally diverse group of metalloproteins sharing a distinctive {alpha}{beta}/{alpha}{beta} fold and a characteristic metal binding motif. A large number of open reading frames identified in genomic sequencing efforts have been annotated as members of this superfamily through sequence comparisons. However, structural and functional studies performed on purified proteins are normally needed to unequivocally include a newly discovered protein in the M{beta}L superfamily. Here we report the spectroscopic characterization of recombinant YcbL, a gene product annotated as a member of the M{beta}L superfamily whose function in vivo remains unknown. By taking advantage of the structural features characterizing the M{beta}L superfamily metal binding motif, we performed spectroscopic studies on Zn(II)- and Co(II)-substituted YcbL to structurally interrogate the metal binding site. The dinuclear center in Co(II)-YcbL was shown to display characteristic electronic absorption features in the visible region, which were also observed in an engineered M{beta}L aimed at mimicking this metal site. Thus, the spectroscopic features reported herein can be employed as a signature to readily identify and characterize the presence of these ubiquitous metal binding sites.

59 BASIC BIOLOGICAL SCIENCES↗

A novel synthetic single crystal diamond device for in vivo dosimetry

Purpose: Aim of the present work is to evaluate the synthetic single crystal diamond Schottky photodiode developed at the laboratories of “Tor Vergata” University in Rome in a new dosimeter configuration specifically designed for offline wireless in vivo dosimetry (IVD) applications. Methods: The new diamond based dosimeter, single crystal diamond detector (SCDD-iv), consists of a small unwired detector and a small external reading unit that can be connected to commercial electrometers for getting the detector readout after irradiation. Two nominally identical SCDD-iv dosimeter prototypes were fabricated and tested. A basic dosimetric characterization of detector performances relevant for IVD application was performed under irradiation with {sup 60}Co and 6 MV photon beams. Preirradiation procedure, response stability, short and long term reproducibility, leakage charge, fading effect, linearity with dose, dose rate dependence, temperature dependence, and angular response were investigated. Results: The SCDD-iv is simple, with no cables linked to the patient and the readout is immediate. The range of response with dose has been tested from 1 up to 12 Gy; the reading is independent of the accumulated dose and dose rate independent in the range between about 0.5 and 5 Gy/min; its temperature dependence is within 0.5% between 25 and 38 °C, and its directional dependence is within 2% from 0° to 90°. The combined relative standard uncertainty of absorbed dose to water measurements is estimated lower than the tolerance and action level of 5%. Conclusions: The reported results indicate the proposed novel offline dosimeter based on a synthetic single crystal diamond Schottky photodiode as a promising candidate for in vivo dosimetry applications with photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

Detector Assembly and the Ultralow-Temperature Refrigerator for XRS

The X-ray spectrometer (XRS) on the Japanese Astro-E Spacecraft is the first ultra low temperature space borne instrument. The system utilizes a 900g Ferric Ammonium Alum (FAA) Adiabatic Demagnetization Refrigerator (ADR) with a helium-3 gas gap heat switch to cool the detector assembly to 0.060K. The system operates in a "single shot" configuration allowing the system to remain at its operating temperature for about 40 hours in the lab. The on-orbit performance is expected to be about 35 hours with a 97% duty cycle. The detector assembly for XRS consists of a 32 channel microcalorimeter array bias electronics, thermometry, and an anti-coincidence detector that are attached to the cold stage of the ADR. To thermally Isolate the detector system from the superfluid helium reservoir, the detector system is suspended by Kevlar cords and electrical connection in made by L30, 17-micron diameter, tensioned NbTi leads. The detectors are read out in a source-follower arrangement using FET amplifiers operating at 130K mounted in multiply-thermally-isolated assemblies that also use Kevlar and stainless steel wiring. The design and thermal performance of this system will be discussed and compared to the theoretical limits.

Porter, F. S.↗

Error-Correcting Codes for Code-Division Multiplexed TES Detectors

Transition edge sensors (TESs) have proven to be highly sensitive and versatile X-ray spectrometers. Upcoming missions, including Athena X-IFU, will rely on highly multiplexed focal planes where more than 32 TES pixels are read out using a single SQUID amplifier channel. We have implemented an error correction algorithm for code-division multiplexed TES signals that can compensate for potential failures of individual SQUID readout channels and that is both scalable and easily implemented in hardware. We present this algorithm for error correction and show results of laboratory tests to assess algorithm performance at recovering TES channels after a SQUID failure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silvabase: A flexible data file management system

The need for a more flexible and efficient data file management system for mission planning in the Mission Operations Laboratory (EO) at MSFC has spawned the development of Silvabase. Silvabase is a new data file structure based on a B+ tree data structure. This data organization allows for efficient forward and backward sequential reads, random searches, and appends to existing data. It also provides random insertions and deletions with reasonable efficiency, utilization of storage space well but not at the expense of speed, and performance of these functions on a large volume of data. Mission planners required that some data be keyed and manipulated in ways not found in a commercial product. Mission planning software is currently being converted to use Silvabase in the Spacelab and Space Station Mission Planning Systems. Silvabase runs on a Digital Equipment Corporation's popular VAX/VMS computers in VAX Fortran. Silvabase has unique features involving time histories and intervals such as in operations research. Because of its flexibility and unique capabilities, Silvabase could be used in almost any government or commercial application that requires efficient reads, searches, and appends in medium to large amounts of almost any kind of data.

Lambing, Steven J.↗

SU-E-T-167: Characterization of In-House Plastic Scintillator Detectors Array for Radiation Therapy

Purpose: To characterize basic performance of plastic scintillator detectors (PSD) array designed for dosimetry of radiation therapy. Methods: An in-house PSD array has been developed by placing single point PSD into customized 2D holder. Each point PSD is a plastic scintillating fiber-based detector designed for highly accurate measurement of small radiotherapy fields used in patient plan verification and machine commissioning and QA procedures. A parallel fiber without PSD is used for Cerenkov separation by subtracting from PSD readings. Cerenkov separation was confirmed by optical spectroscopy. Alternative Cerenkov separation approaches are also investigated. The optical signal was converted to electronic signal with a photodiode and then subsequently amplified. We measured its dosimetry performance, including percentage depth dose and output factor, and compared with reference ion chamber measurements. The PSD array is then placed along the radiation beam for multiple point dose measurement, representing subsets of PDD measurements, or perpendicular to the beam for profile measurements. Results: The dosimetry results of PSD point measurements agree well with reference ion chamber measurements. For percentage depth dose, the maximal differences between PSD and ion chamber results are 3.5% and 2.7% for 6MV and 15MV beams, respectively. For the output factors, PSD measurements are within 3% from ion chamber results. PDD and profile measurement with PSD array are also performed. Conclusions: The current design of multichannel PSD array is feasible for the dosimetry measurement in radiation therapy. Dose distribution along or perpendicular to the beam path could be measured. It might as well be used as range verification in proton therapy.A PS hollow fiber detector will be investigated to eliminate the Cerenkov radiation effect so that all 32 channels can be used.

60 APPLIED LIFE SCIENCES↗

Technology Development for the Advanced Technology Large Aperture Space Telescope (ATLAST) as a Candidate Large UV-Optical-Infrared (LUVOIR) Surveyor

The Advanced Technology Large Aperture Space Telescope (ATLAST) team has identified five key technologies to enable candidate architectures for the future large-aperture ultraviolet/optical/infrared (LUVOIR) space observatory envisioned by the NASA Astrophysics 30-year roadmap, Enduring Quests, Daring Visions. The science goals of ATLAST address a broad range of astrophysical questions from early galaxy and star formation to the processes that contributed to the formation of life on Earth, combining general astrophysics with direct-imaging and spectroscopy of habitable exoplanets. The key technologies are: internal coronagraphs, starshades (or external occulters), ultra-stable large-aperture telescopes, detectors, and mirror coatings. Selected technology performance goals include: 1x1010 raw contrast at an inner working angle of 35 milli-arcseconds, wavefront error stability on the order of 10 pm RMS per wavefront control step, autonomous on-board sensing & control, and zero-read-noise single-photon detectors spanning the exoplanet science bandpass between 400 nm and 1.8 μm. Development of these technologies will provide significant advances over current and planned observatories in terms of sensitivity, angular resolution, stability, and high-contrast imaging. The science goals of ATLAST are presented and flowed down to top-level telescope and instrument performance requirements in the context of a reference architecture: a 10-meter-class, segmented aperture telescope operating at room temperature (~290 K) at the sun-Earth Lagrange-2 point. For each technology area, we define best estimates of required capabilities, current state-of-the-art performance, and current Technology Readiness Level (TRL) - thus identifying the current technology gap. We report on current, planned, or recommended efforts to develop each technology to TRL 5.

Technology Development↗

In‐memory integration of existing software components for parallel adaptive unstructured mesh workflows

Summary Reliable mesh‐based simulations are needed to solve complex engineering problems. Mesh adaptivity can increase reliability by reducing discretization errors but requires multiple software components to exchange information. Often, components exchange information by reading and writing a common file format. This file‐based approach becomes a problem on massively parallel computers where filesystem bandwidth is a critical performance bottleneck. Our approach using data streams and component interfaces avoids the filesystem bottleneck. In this paper, we present these techniques and their use for coupling mesh adaptivity to the PHASTA computational fluid dynamics solver, the Albany multi‐physics framework, and the Omega3P linear accelerator frequency analysis applications. Performance results are reported on up to 16,384 cores of an Intel Knights Landing‐based system.

Smith, Cameron W.↗

Effectiveness of a genetic test panel designed for gynecological cancer: an exploratory study

To increase diagnostic efficiency and cost-effectiveness, we performed an exploratory genetic test using a newly designed panel containing 28 actionable and druggable genes, alterations in which are frequently reported in gynecological cancers (TANRE-G, Targeted variants ANalysis RElated to Gynecological cancers). Samples consisted of the formalin-fixed, paraffin-embedded tissue of endometrial (4 cases), cervical (3 cases), and ovarian (4 cases) carcinomas. The sequencing procedure was performed using Ion PGM in our institute with related sequencing kits, and data were analyzed using ClinVar. The present system achieved more than 2500 reads in all tumor samples, and enabled a copy number variation analysis. Results showed that actionable and druggable mutations were detected in 82% (9/11) and 64% (7/11) of cases, respectively, which was similar to other commercially available genetic tests. The amplification of MYC and KRAS was also detected. The analysis cost for each sample was JPY 94,000 (USD 850). These results demonstrate the potential of the TANRE-G panel as an effective tool for examining genetic alterations in gynecological cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

YBCO-on-Kapton: Material for High-Density Quan-tum Computer Interconnects with Ultra-Low Thermal Conductance

Development of practical quantum computers would require 1000's of qubits and equally large number of read-outs, bias and drive lines. New materials that combine low passive loss and good RF properties are needed. In this study we report performance of signal interconnects comprised of high-temperature YBCO films that are exfoliated from a metal substrate and transferred to a E-Kapton tape. The technology offers low-loss transition be-tween 60 K to sub-mK environments and interfacing with off-shelf flexible silicon electronics. We demonstrate < 1 dB/m at-tenuation at 6 GHz at 77 K. The microstrip assemblies demon-strated no degradation upon multiple cycles to liquid Nitrogen and conduction cooling down to 18 K. We discuss designs of a practical high-density signal cable with passive heat load well below 1 μW per line. The YBCO-on-Kapton technology offers a practical pathway to large error-corrected quantum computing systems.

47 OTHER INSTRUMENTATION↗

Minority carrier lifetimes in very long-wave infrared InAs/GaInSb superlattices

Here, significantly improved carrier lifetimes in very-long wave infrared InAs/GaInSb superlattice(SL) absorbers are demonstrated by using time-resolved microwave reflectance (TMR) measurements. A nominal 47.0 Å InAs/21.5 Å Ga 0.75 In 0.25 Sb SLstructure that produces an approximately 25 μm response at 10 K has a minority carrier lifetime of 140 ± 20 ns at 18 K, which is markedly long for SL absorber with such a narrow bandgap. This improvement is attributed to the strain-engineered ternary design. Such SL employs a shorter period with reduced gallium in order to achieve good optical absorption and epitaxial advantages, which ultimately leads to the improvements in the minority carrier lifetime by reducing Shockley–Read–Hall (SRH) defects. By analyzing the temperature-dependence of TMR decay data, the recombination mechanisms and trap states that currently limit the performance of this SL absorber have been identified. The results show a general decrease in the long-decay lifetime component, which is dominated by the SRH recombination at temperature below ~30 K, and by Auger recombination at temperatures above ~45 K.

36 MATERIALS SCIENCE↗

A new FPGA-based trigger/DAQ system for the MTV experiment at TRIUMF

A new FPGA based data acquisition (DAQ) and trigger combined system is developed for the MTV experiment (Mott Polarimetry for T-Violation Experiment). The MTV experiment measures backward Mott scattering events by detecting the incident and scattered tracks using a drift chamber. For the backward scattering probability is as small as less than 0.1%, efficient triggering system is required to select the desired events. An intelligent Level-2 trigger system reading hitting pattern together with its digital readout system are built in a custom FPGA system. In this paper, design overview and results from performance tests are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

diBELLA: Distributed Long Read to Long Read Alignment

© 2019 ACM. We present a parallel algorithm and scalable implementation for genome analysis, specifically the problem of finding overlaps and alignments for data from "third generation" long read sequencers [29]. While long sequences of DNA offer enormous advantages for biological analysis and insight, current long read sequencing instruments have high error rates and therefore require different approaches to analysis than their short read counterparts. Our work focuses on an efficient distributed-memory parallelization of an accurate single-node algorithm for overlapping and aligning long reads. We achieve scalability of this irregular algorithm by addressing the competing issues of increasing parallelism, minimizing communication, constraining the memory footprint, and ensuring good load balance. The resulting application, diBELLA, is the first distributed memory overlapper and aligner specifically designed for long reads and parallel scalability. We describe and present analyses for high level design trade-offs and conduct an extensive empirical analysis that compares performance characteristics across state-of-the-art HPC systems as well as a commercial cloud architectures, highlighting the advantages of state-of-the-art network technologies.

Ellis, Marquita↗