Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

X-ray structure determination using low-resolution electron microscopy maps for molecular replacement

Structures of multi-subunit macromolecular machines are primarily determined by either electron microscopy (EM) or X-ray crystallography. In many cases, a structure for a complex can be obtained at low resolution (at a coarse level of detail) with EM and at higher resolution (with finer detail) by X-ray crystallography. The integration of these two structural techniques is becoming increasingly important for generating atomic models of macromolecular complexes. A low-resolution EM image can be a powerful tool for obtaining the "phase" information that is missing from an X-ray crystallography experiment, however integration of EM and X-ray diffraction data has been technically challenging. Here we show a step-by-step protocol that explains how low-resolution EM maps can be placed in the crystallographic unit cell by molecular replacement, and how initial phases computed from the placed EM density are extended to high resolution by averaging maps over non-crystallographic symmetry. As the resolution gap between EM and Xray crystallography continues to narrow, the use of EM maps to help with X-ray crystal structure determination, as described in this protocol, will become increasingly effective.

59 BASIC BIOLOGICAL SCIENCES↗

In vivo volumetric imaging of calcium and glutamate activity at synapses with high spatiotemporal resolution

Studying neuronal activity at synapses requires high spatiotemporal resolution. For high spatial resolution in vivo imaging at depth, adaptive optics (AO) is required to correct sample-induced aberrations. To improve temporal resolution, Bessel focus has been combined with two-photon fluorescence microscopy (2PFM) for fast volumetric imaging at subcellular lateral resolution. To achieve both high-spatial and high-temporal resolution at depth, we develop an efficient AO method that corrects the distorted wavefront of Bessel focus at the objective focal plane and recovers diffraction-limited imaging performance. Applying AO Bessel focus scanning 2PFM to volumetric imaging of zebrafish larval and mouse brains down to 500 µm depth, we demonstrate substantial improvements in the sensitivity and resolution of structural and functional measurements of synapses in vivo. This enables volumetric measurements of synaptic calcium and glutamate activity at high accuracy, including the simultaneous recording of glutamate activity of apical and basal dendritic spines in the mouse cortex.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging 3D chemistry at 1 nm resolution with fused multi-modal electron tomography

Measuring the three-dimensional (3D) distribution of chemistry in nanoscale matter is a longstanding challenge for metrological science. The inelastic scattering events required for 3D chemical imaging are too rare, requiring high beam exposure that destroys the specimen before an experiment is completed. Even larger doses are required to achieve high resolution. Thus, chemical mapping in 3D has been unachievable except at lower resolution with the most radiation-hard materials. Here, high-resolution 3D chemical imaging is achieved near or below one-nanometer resolution in an Au-Fe 3 O 4 metamaterial within an organic ligand matrix, Co 3 O 4 -Mn 3 O 4 core-shell nanocrystals, and ZnS-Cu 0.64 S 0.36 nanomaterial using fused multi-modal electron tomography. Multi-modal data fusion enables high-resolution chemical tomography often with 99% less dose by linking information encoded within both elastic (HAADF) and inelastic (EDX/EELS) signals. We thus demonstrate that sub-nanometer 3D resolution of chemistry is measurable for a broad class of geometrically and compositionally complex materials.

36 MATERIALS SCIENCE↗

Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium

The coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to an Orbitrap Fusion Lumos Tribrid 1M mass spectrometer is described as a significant step towards the elimination of isobaric interferences in elemental/isotopic mass spectrometry. The developed setup permits broadband, elemental mass spectra to be easily acquired at a mass resolution (m/Δm) of 500 000. A new ion source housing and integrated control system provide enhanced stability and sensitivity of the microplasma ion source in comparison to the previous designs. Detailed evaluation of the ion sampling parameters provided insight into differences with other Orbitrap platforms leading to a 5-fold increase in resolution in elemental/isotopic analysis. The roles of data acquisition/ion processing parameters were evaluated with regards to the precision and accuracy of 235 U/ 238 U isotope ratios. Significantly, the precision of those measurements improves as a function of pre-set mass resolution up to a value of 1 000 000, where a precision of 0.086% RSD is obtained for uranium concentrations of 100 ng mL− 1 . Analytical response curves (log–log), acquired for the two uranium isotopes at a resolution of 120 000 were linear (R 2 = 0.9969) over more than 5 orders of magnitude, with limits of detection of 1 pg mL −1 for U. Based on 60 μL injection volumes, this represents a mass of 70 fg 235 U. These figures of merit satisfy International Target Values (ITVs) for Measurement Uncertainties in Safeguarding Nuclear Materials set by the International Atomic Energy Agency (IAEA). Ultimately, and totally unique from beam-type instruments, the move to the higher-resolution Orbitrap platform provides all of the benefits of high mass resolution, with no penalties in sensitivity, precision, or dynamic range for uranium analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers

Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches are not ideal: using strip detectors loses the 2D position sensitivity (important for, e.g., background estimation) and the high counting rate; using pixel detectors with a small pitch results in complex charge sharing behaviour and typically have a small size. Developing pixel detectors with high aspect ratio and a small pitch in the wavelength dispersive direction would be ideal, however, it would require a substantial ASIC development. We present a new approach, with a novel sensor design using rectangular pixels with a high aspect ratio (between strips and pixels, further called “strixels”), and strixel redistribution to match the square pixel arrays of typical ASICs. This results in a sensor area of 17.4 mm × 77 mm, with a fine pitch of 25 µm in the horizontal direction resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs, leveraging their low noise (43 e - , or 180 eV rms). We present results obtained with a Hammerhead ePix100 camera, showing that the small pitch (25 µm) in the dispersion direction maximizes performance for both high and low photon occupancies, resulting in optimal WDS energy resolution. The low noise level at high photon occupancy allows precise photon counting, while at low occupancy, both the energy and the subpixel position can be reconstructed for every photon, allowing an ultrahigh resolution (in the order of 1 µm) in the dispersion direction and rejection of scattered beam and harmonics. Using strixel sensors with redistribution and flip-chip bonding to standard ePix readout ASICs results in ultrahigh position resolution (~1 µm) and low noise in WDS applications, leveraging the advantages of hybrid pixel detectors (high production yield, good availability, relatively inexpensive) while minimizing development complexity through sharing the ASIC, hardware, software and DAQ development with other versions of ePix cameras.

47 OTHER INSTRUMENTATION↗

The Velociprobe: An ultrafast hard X-ray nanoprobe for high-resolution ptychographic imaging

Motivated by the advanced photon source upgrade, a new hard X-ray microscope called "Velociprobe" has been recently designed and built for fast ptychographic imaging with high spatial resolution. We are addressing the challenges of high-resolution and fast scanning with novel hardware designs, advanced motion controls, and new data acquisition strategies, including the use of high-bandwidth interferometric measurements. The use of granite, air-bearing-supported stages provides the necessary long travel ranges for coarse motion to accommodate real samples and variable energy operation while remaining highly stable during fine scanning. Scanning the low-mass zone plate enables high-speed and high-precision motion of the probe over the sample. With an advanced control algorithm implemented in a closed-loop feedback system, the setup achieves a position resolution (3σ) of 2 nm. The instrument performance is evaluated by 2D fly-scan ptychography with our developed data acquisition strategies. A spatial resolution of 8.8 nm has been demonstrated on a Au test sample with a detector continuous frame rate of 200 Hz. Using a higher flux X-ray source provided by double-multilayer monochromator, we achieve 10 nm resolution for an integrated circuit sample in an ultrafast scan with a detector's full continuous frame rate of 3000 Hz (0.33 ms per exposure), resulting in an outstanding imaging rate of 9 x 10 4 resolution elements per second

36 MATERIALS SCIENCE↗

Tuning time and energy resolution in time-resolved photoemission spectroscopy with nonlinear crystals

Time- and angle-resolved photoemission spectroscopy is a powerful probe of electronic band structures out of equilibrium. Tuning time and energy resolution to suit a particular scientific question has become an increasingly important experimental consideration. Many instruments use cascaded frequency doubling in nonlinear crystals to generate the required ultraviolet probe pulses. In this work, we demonstrate how calculations clarify the relationship between laser bandwidth and nonlinear crystal thickness contributing to experimental resolutions and place intrinsic limits on the achievable time-bandwidth product. Experimentally, we tune time and energy resolution by varying the thickness of nonlinear β-BaB 2 O 4 crystals for frequency upconversion, providing a flexible experiment design. We achieve time resolutions of 58–103 fs and corresponding energy resolutions of 55–27 meV. We propose a method to select crystal thickness based on desired experimental resolutions.

36 MATERIALS SCIENCE↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Future projections of storm surge in Hurricane Katrina and sensitivity to meteorological forcing resolution

In this study, we investigated whether and how the storm surge induced by Hurricane Katrina could change if it occurs in a future warmer climate, and the sensitivity of the changes to atmospheric forcing resolution. Climate model simulations of Hurricane Katrina at 27 km, 4.5 km, and 3 km resolutions were used to drive storm surge simulations in historical and future climates using the ADvanced CIRCulation (ADCIRC) model. We found that peak surge height increased significantly in the future with all forcing resolutions. However, the future projection is 22% greater in the 3 km forcing, typical of regional climate models, compared to the 27 km forcing, typical of state-of-the-art global climate models. Additionally, the spatial extent of the future change is highly sensitive to forcing resolution, extending most broadly under the 27 km forcing. Furthermore, we found that storm surge duration decreases in the future with all forcing resolutions due to increasing TC translation speed and decreasing ocean lifetime. However, the future change in the surge duration is sensitive to the forcing resolution, decreasing by 31% in the 27 km forcing and 6% in the 3 km forcing.

54 ENVIRONMENTAL SCIENCES↗

Deep-learning-based canopy height model generation from sub-meter resolution panchromatic satellite imagery

Canopy height models (CHMs) with sufficient resolution to distinguish individual trees are useful for a variety of applications. However, standard techniques to acquire such data, such as airborne lidar surveying, are often prohibitively expensive. Deep learning techniques for generating CHMs from high-resolution imagery are an attractive option to reduce costs. To date, success with these methods has been demonstrated using multichannel aerial photography and specialized satellite data products derived from multiple sensors, neither of which is commonly available at temporal resolutions finer than one year. Here we demonstrate a method to generate sub-meter resolution CHMs in three forests in California using a more abundant data source: sub-meter resolution, panchromatic satellite imagery from a single sensor. We show that phenology and species composition play important roles in model transferability; when trained using imagery from a single conifer forest in autumn, the model performs well on autumn imagery from a second conifer forest several hundred kilometers distant with no re-training. With modest additions to the training dataset, the same model generates minimally biased estimates of canopy height in both conifer and deciduous forests during multiple seasons. Because the model operates on satellite data with global coverage and a relatively short return interval, we propose its suitability to extrapolate tree-level canopy height data to remote regions and conduct high-temporal resolution monitoring of forest structure. We furthermore demonstrate the workflow’s applicability to fire modeling by conducting simulations in forests populated by trees measured using both this approach and airborne lidar surveying. We find minimal differences in fire behavior relative to a baseline case in which only statistical distributions of tree height and crown area are known. This result underscores the value of forest structural information derived from our workflow for improving the fidelity of wildland fire simulations, among other ecological applications.

54 ENVIRONMENTAL SCIENCES↗

Short-range correlation physics at low renormalization group resolution

Recent experiments have succeeded in isolating processes for which short-range correlation (SRC) physics is dominant and well accounted for by SRC phenomenology. But an alternative and compelling picture emerges from renormalization group (RG) evolution to low RG resolution. At high RG resolution, SRCs are identified as components in the nuclear wave function with relative pair momenta greater than the Fermi momentum. Scale separation results in wave-function factorization that can be exploited with phenomenologies such as the generalized contact formalism or the low-order correlation operator approximation. Evolution to lower resolution shifts SRC physics from nuclear structure to the reaction operators without changing the measured observables. We show how the features of SRC phenomenology manifested at high RG resolution are cleanly identified at low RG resolution using simple two-body operators and local-density approximations with uncorrelated wave functions, all of which can be systematically generalized. We verify that the experimental consequences to date follow directly at low resolution from well-established properties of nucleon-nucleon interactions such as the tensor force. Thus the RG reconciles the contrasting pictures of the same experiment and shows how to get correct results using wave functions without SRC components. Finally, our demonstration has implications for the analysis of knockout reactions for which SRC physics is not cleanly isolated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resolution requirements for numerical modeling of neutrino quantum kinetics

Neutrino quantum kinetics is a rapidly evolving field in computational astrophysics, with a primary focus on collective neutrino oscillations in core-collapse supernovae and postmerger phases of binary neutron star mergers. In recent years, there has been considerable debate concerning resolution dependence in numerical simulations. In this paper, we conduct a comprehensive resolution study in both angular- and spatial directions by using two independent schemes of quantum kinetic neutrino transport: finite volume and pseudospectral methods. We complement our discussion by linear stability analysis including inhomogeneous modes. Our result suggests that decreasing spatial resolutions underestimates the growth of flavor instability, and then leads to wrong asymptotic states of flavor conversions, which potentially has a critical impact on astrophysical consequences. We further delve into numerical results of low resolution simulations, that reveals the underlying mechanism responsible for numerical artifacts caused by insufficient resolutions. Finally, this study settles the debate on requirements of resolutions and serves as a guideline for numerical modeling of quantum kinetic neutrino transport.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Grid resolution requirement for resolving rare and high intensity wall-shear stress events in direct numerical simulations

Turbulent signals are intermittent with large instantaneous fluctuations. Such large fluctuations lead to small Kolmogorov scales that are hard to resolve in numerical simulations [P. K. Yeung, K. R. Sreenivasan, and S. B. Pope, Effects of finite spatial and temporal resolution in direct numerical simulations of incompressible isotropic turbulence, Phys. Rev. Fluids 3, 064603 (2018)]. Here, the present paper follows the above basic logic, but instead of dissipation events in isotropic turbulence, we study wall-shear stress events in plane channel flow. Wall-shear stress fluctuations are increasingly more intermittent as the Reynolds number increases. Hence, one has to employ higher grid resolutions as the Reynolds number increases in order to resolve a given percentage of wall-shear stress events. The objective of this paper is to quantify effects of the grid resolutions on the rare and high intensity wall-shear stress events. We find that the standard grid resolution resolves about 99% of the wall-shear stress events at Re τ = 180. A slightly higher grid resolution has to be employed in order to resolve 99% of the wall-shear stress events at higher Reynolds numbers, and if the standard grid resolution is used for, e.g., a Re τ = 10000 channel flow, one resolves about 90%–95% wall-shear stress events.

42 ENGINEERING↗

Super-resolution image display using diffractive decoders

High-resolution image projection over a large field of view (FOV) is hindered by the restricted space-bandwidth product (SBP) of wavefront modulators. We report a deep learning–enabled diffractive display based on a jointly trained pair of an electronic encoder and a diffractive decoder to synthesize/project super-resolved images using low-resolution wavefront modulators. The digital encoder rapidly preprocesses the high-resolution images so that their spatial information is encoded into low-resolution patterns, projected via a low SBP wavefront modulator. The diffractive decoder processes these low-resolution patterns using transmissive layers structured using deep learning to all-optically synthesize/project super-resolved images at its output FOV. This diffractive image display can achieve a super-resolution factor of ~4, increasing the SBP by ~16-fold. We experimentally validate its success using 3D-printed diffractive decoders that operate at the terahertz spectrum. This diffractive image decoder can be scaled to operate at visible wavelengths and used to design large SBP displays that are compact, low power, and computationally efficient.

36 MATERIALS SCIENCE↗

Peering into cloud physics using ultra-fine resolution radar and lidar systems

Cloud microphysical processes, such as droplet activation, condensational growth, and collisional growth, play a central role in the evolution of clouds and precipitation. Accurate representations of these processes in numerical models are challenging partially due to incomplete understanding of them at the process-level arising from limited systematic observations. Most surface-based active remote sensors, including today’s operational cloud radars and lidars, have a resolution on the order of tens of meters. This resolution is insufficient to resolve cloud microphysical processes that manifest at finer (meter and sub-meter) scales. A new set of ultra-high-resolution ground-based radar and lidar systems have been developed to address this observational gap. The newly developed 94-GHz cloud radar has a range resolution down to 2.8 m, or a factor of 10 finer than typical radars, using a large bandwidth and quadratic phase coding techniques. The lidar has a range resolution down to 10 cm, or a factor of 100 finer than typical lidars, using a time-gated time-correlated single photon counting technique. Such high-resolution observations were previously only achievable through in situ aircraft measurements. Even then, aircraft measurements do not permit continuous long-term cloud observation as is possible with ground-based remote sensing instruments. In this study, the first-light cloud observations from the new radar and lidar systems are shown to reveal detailed cloud structures that conventional sensors could only perceive in a bulk sense, thus providing new avenues to investigate cloud microphysical processes and their impact on weather and climate.

54 ENVIRONMENTAL SCIENCES↗

Deep learning enhanced super-resolution x-ray fluorescence microscopy by a dual-branch network

X-ray fluorescence (XRF) microscopy is a powerful technique for quantifying the distribution of elements in complex materials, which makes it a crucial imaging technique across a wide range of disciplines in physical and biological sciences, including chemistry, materials science, microbiology, and geosciences. However, as a scanning microscopy technique, the spatial resolution of XRF imaging is inherently constrained by the x-ray probe profile and scanning step size. Here we propose a dual-branch machine learning (ML) model, which can extract scale-variant features and bypass abundant low-frequency information separately, to enhance the spatial resolution of the XRF images by mitigating the effects of blurring from the probe profile. The model is trained by simulated natural images, and a two-stage training strategy is used to overcome the domain gap between the natural images and experimental data. The tomography reconstruction from enhanced XRF projections shows an improvement in resolution by a scale factor of four and reveals distinct internal features invisible in low-resolution XRF within a battery sample. This study offers a promising approach for obtaining high-resolution XRF imaging from its low-resolution version, paving the way for future investigations in a broader range of disciplines and materials.

36 MATERIALS SCIENCE↗

Towards a Fine-Resolution Global Coupled Climate System for Prediction on Decadal/Centennial Scales

The over-arching goal of this project was to contribute to the realization of a fully coupled fine resolution Earth System Model simulation in which a weather-scale atmosphere is coupled to an ocean in which mesoscale eddies are largely resolved. Both a prototype fine-resolution fully coupled ESM simulation and a first-ever multi-decadal forced fine-resolution global coupled ocean/ice simulation were configured, tested, run, and analyzed as part of this grant. Science questions focused on the gains from the use of high horizontal resolution, particularly in the ocean and sea-ice, with respect to climatically important processes. Both these fine resolution coupled ocean/sea ice and fully-coupled simulations and precedent stand-alone eddy-resolving ocean and eddy-permitting coupled ocean/ice simulations were used to explore the high resolution regime. Overall, these studies showed that the presence of mesoscale eddies significantly impacted mixing processes and the global meridional overturning circulation in the ocean simulations. Fourteen refereed publications and a Ph.D. dissertation resulted from this grant.

54 ENVIRONMENTAL SCIENCES↗

Negative Ion Drift Time Projection Chamber Development for High-Resolution Tracking

Gas Time Projection Chambers (TPCs) are used extensively in High Energy Physics. Modern micro-pattern gaseous detectors (MPGDs) have made it feasible to construct large-volume TPCs with high readout granularity, so that ionization can be imaged with spatial resolution of order 100 μm or better. A challenge with large TPCs is preserving the track geometry over large drift distances. The reduced diffusion offered by negative ion drift (NID) has long been considered a possible means to scaling up TPCs at reduced cost, but NID has up to now required toxic and often flammable multi-component gas mixtures. A number of recent breakthroughs in the field have, however, led to a resurgence of interest in NID gas TPCs: First, it was found that multiple charge carriers in NID can be utilized to measure the absolute position of primary ionization in the drift direction, yielding a powerful new handle on backgrounds, at zero additional cost. Second, work by one of the PIs has revealed SF6 gas to be a non-toxic, non-flammable, NID gas with suitable minority charge carriers present. Third, preliminary work by the PIs suggests that multiple MPGD technologies work well with SF6. This opens the door to a new generation of large, high-resolution, low-background, low-cost gas TPCs. In this work we will investigate MPGD charge multiplication and charge readout in NID TPCs with SF6 gas. The objectives are to quantify the improvement over electron drift TPCs, and to identify the optimal MPGD types, operational parameters, electronics, and vacuum technologies for future low-background experiments. We will measure low-level detector performance parameters such as gain, gain resolution, and spatial resolution, as well as the resulting higher-level performance parameters such nuclear recoil identification efficiency, gamma-ray background rejection, track angle resolution and recoil energy resolution. The proposed work also includes investigation of acrylic vacuum vessels and collaboration on dedicated charge readout chips, both required for next-generation NID MPGD TPCs. MGPD NID TPCs may prove transformative for applications which require both high readout granularity and large detector volumes, such as the reconstruction of nuclear recoils in the context of large-scale directional dark matter searches, measurements of coherent neutrino-nucleus scattering, and directional neutron detection. While the proposed work is focused on nuclear recoils, the lessons learned will be widely applicable to gas TPCs in HEP, and hence have broad impact.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗