Search NASA⌕ Search

SEARCH · Search NASA

Results for “safety visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Digital Human Modeling

The development of models to represent human characteristics and behaviors in human factors is broad and general. The term "model" can refer to any metaphor to represent any aspect of the human; it is generally used in research to mean a mathematical tool for the simulation (often in software, which makes the simulation digital) of some aspect of human performance and for the prediction of future outcomes. This section is restricted to the application of human models in physical design, e.g., in human factors engineering. This design effort is typically human interface design, and the digital models used are anthropometric. That is, they are visual models that are the physical shape of humans and that have the capabilities and constraints of humans of a selected population. They are distinct from the avatars used in the entertainment industry (movies, video games, and the like) in precisely that regard: as models, they are created through the application of data on humans, and they are used to predict human response; body stresses workspaces. DHM enable iterative evaluation of a large number of concepts and support rapid analysis, as compared with use of physical mockups. They can be used to evaluate feasibility of escape of a suited astronaut from a damaged vehicle, before launch or after an abort (England, et al., 2012). Throughout most of human spaceflight, little attention has been paid to worksite design for ground workers. As a result of repeated damage to the Space Shuttle which adversely affected flight safety, DHM analyses of ground assembly and maintenance have been developed over the last five years for the design of new flight systems (Stambolian, 2012, Dischinger and Dunn Jackson, 2014). The intent of these analyses is to assure the design supports the work of the ground crew personnel and thereby protect the launch vehicle. They help the analyst address basic human factors engineering questions: can a worker reach the task site from the work platform provided; can she or he see the task site; can she or he control tools, which, if dropped, might damage the system? Figure 7.3.1 provides an example of such analysis for a future NASA launch vehicle. [figure 7.3.1 here] In-space systems for operation by astronauts have long been targets for DHM analysis, given the focus on mission success and concerns for astronaut safety. Figure 7.3.2 illustrates the analysis of the design to support astronaut tasks for an International Space Station glovebox. [Figure 7.3.2 here] Use by

Dischinger, H. Charles, Jr.↗

Global Response of the Space Shuttle External Tank with the Presence of Intertank Stringer Cracks and Radius Blocks

After propellant was loaded into the external tank (ET), the November 5, 2010 launch of Space Shuttle mission STS-133 was scrubbed due to a gaseous hydrogen leak located in a vent line near the ground umbilical and ET connection. Subsequent visual inspections identified cracks in the sprayed-on foam insulation in the forward end of the ET intertank segment, adjacent to the liquid oxygen (LOX) tank, as shown in Figure 1. These cracks necessitated repair of the foam due to debris concerns that violated launch constraints. As part of the repair process, the affected foam was removed to reveal cracks in the underlying external hat stiffeners on the intertank, as shown in Figure 2. Ultimately, five stiffeners were discovered to be cracked adjacent to the LOX tank. As the managing center for the ET Project, NASA Marshall Space Flight Center (MSFC) coordinated failure investigation and repair activities among multiple organizations, which included the ET prime contractor (Lockheed Martin Space Systems Michoud Operations), the Space Shuttle Program Office at the NASA Johnson Space Center (JSC), the NASA Kennedy Space Center (KSC), and the NASA Engineering and Safety Center (NESC). STS-133 utilized the external tank designated as ET-137. Many aspects of the investigation have been reported previously in Refs. 1-7, which focus on the root cause of the failures, the flight readiness rationale and the local analyses of the stringer failures and repair. This paper summarizes the global analyses that were conducted on ET-137 as part of the NESC effort during the investigation, which was conducted primarily to determine if the repairs that were introduced to the stringers would alter the global response of the ET. In the process of the investigation, a new STAGS tabular input capability was developed to more easily introduce the aerodynamic pressure loads using a method that could easily be extended to incorporate finite element property data such as skin and stiffener thicknesses and beam cross-sectional properties.

Lovejoy, Andrew E.↗

Carbon Ion Radiation Therapy Improves the Prognosis of Unresectable Adult Bone and Soft-Tissue Sarcoma of the Head and Neck

Purpose: To evaluate the safety and efficacy of carbon ion radiotherapy (C-ion RT) with 70.4 GyE for unresectable bone and soft-tissue sarcoma of the adult head and neck. Methods and Materials: Twenty-seven patients (mean age, 46.2 years) were enrolled in this prospective study on C-ion RT with 70.4 GyE/16 fractions (fr) between April 2001 and February 2008. The primary end points were acute and late reactions of normal tissues, local control rate, and overall survival rate. The secondary end point was efficacy of the treatment in comparison to historical results with 57.6 or 64.0 GyE/16 fr. Results: The 3-year local control rate and overall survival rate for all patients were 91.8% (95% confidence interval [CI] = 81.0-100%) and 74.1% (95% CI = 57.5-90.6%), respectively. Acute reaction of Grade 3 or more was observed in only 1 patient. With regard to late reactions, visual loss was observed in 1 patient and a Grade 3 reaction of the maxillary bone was observed in 4 patients. A comparison with historical results revealed that the local control rate with 70.4 GyE was significantly higher than that with 57.6 or 64.0 GyE (3-year, 91.8% vs. 23.6%, p < 0.0001). Furthermore, the overall survival with 70.4 GyE tended to be higher than that with 57.6 or 64.0 GyE (3-year, 74.1% vs. 42.9%, p = 0.09). Conclusion: C-ion RT with 70.4 GyE/16 fr for bone and soft-tissue sarcoma of the adult head and neck appears to be effective with acceptable toxicities in comparison to conventional RT and C-ion RT with lower doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting and Managing Lighting and Visibility for Human Operations in Space

Lighting is critical to human visual performance. On earth this problem is well understood and solutions are well defined and executed. Because the sun rises and sets on average every 45 minutes during Earth orbit, humans working in space must cope with ~ extremely dynamic lighting conditions varying from very low light conditions to severe glare and contrast conditions. For critical operations, it is essential that lighting conditions be predictable and manageable. Mission planners need to detelmine whether low-light video cameras are required or whether additional luminaires, or lamps, need to be flown . Crew and flight directors need to have up to date daylight orbit time lines showing the best and worst viewing conditions for sunlight and shadowing. Where applicable and possible, lighting conditions need to be part of crew training. In addition, it is desirable to optimize the quantity and quality of light because of the potential impacts on crew safety, delivery costs, electrical power and equipment maintainability for both exterior and interior conditions. Addressing these issues, an illumination modeling system has been developed in the Space Human Factors Laboratory at ASA Johnson Space Center. The system is the integration of a physically based ray-tracing package ("Radiance"), developed at the Lawrence Berkeley Laboratories, a human factors oriented geometric modeling system developed by NASA and an extensive database of humans and their work environments. Measured and published data has been collected for exterior and interior surface reflectivity; luminaire beam spread distribution, color and intensity and video camera light sensitivity and has been associated with their corresponding geometric models. Selecting an eye-point and one or more light sources, including sun and earthshine, a ~ snapshot of the light energy reaching the surfaces or reaching the eye point is computed. This energy map is then used to extract the required information needed for useful predictions. Using a validated, comprehensive illumination model integrated with empirically derived data, predictions of lighting and viewing conditions have been successfully used for Shuttle and Space Station planning and assembly operations. It has successfully balanced the needs for adequate human performance with the utili zation of resources. Keywords: Modeling, ray tracing, luminaires, refl ectivity, luminance, illuminance.

Maida, James C.↗

Exploring the Use of Muon Momentum for Detection of Nuclear Material Within Shielded Spent Nuclear Fuel Dry Casks

The inspection of the storage containers that house used nuclear fuel is an important issue facing the nuclear industry; currently, there are limited options available to provide for even minimal inspections. During the long storage life of the fuel, intermediate handling and transportation activities may take place that can create concerns regarding fuel integrity (safety) and continuity of knowledge (safeguards and security). Accidents and natural disasters also contribute to this concern. The reliable and safe management of used nuclear fuel is among the critical tasks to be addressed for the advancement of fission-based nuclear energy in the United States and elsewhere. Since the early 1950's, when the first nuclear power plant began to produce electricity, approximately 65,000 metric tons of used nuclear fuel have been generated in the United States. The postponement of the opening of a permanent repository until 2048 will lead to increased used fuel accumulation at reactor sites. A rapid increase in storage installations with more than 9,000 casks storing {approx}420,000 assemblies is anticipated by 2050 even if no new nuclear power plants are built. After used nuclear fuel has been placed inside a cask, the cask is sealed, not allowing for visual inspection. Conventional methods, e.g., x-rays, are limited in that they cannot penetrate dense, well-shielded objects. More sophisticated techniques, such as penetrating neutrons or proton radiography, require the use of an expensive accelerator. Efforts by Ziock et al. using neutron and gamma-ray imagers concluded that '...the signatures are deemed insufficient to uniquely identify individual casks of the same type...'. It was found that the gamma-ray and neutron images were dominated by diffusion and thermalization effects resulting from the large amount of shielding. One promising mode of inspection would use cosmic-ray muons. These muons are naturally generated, are able to penetrate dense materials, and are incident from all directions above the horizon. Tomography performed using these muons could potentially provide efficient, inexpensive, remote assessment of used nuclear fuel. However, current muon applications are limited in that they have not included momentum measurement. If momentum measurement could be incorporated, that would represent a big step forward because it would allow more accurate estimation of the muon observables, e.g., scattering variance. This approach has the potential to reconstruct the contents of a cask with improved resolution and identify partial defects, fuel assemblies, and individual fuel rods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-151: Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT

Purpose: To estimate dosimetric errors resulting from using contours deformably mapped from planning CT to 4D cone beam CT (CBCT) images for image-guided adaptive radiotherapy of locally advanced non-small cell lung cancer (NSCLC). Methods: Ten locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan-beam CT (4DFBCT) and weekly 4DCBCT scans. Multiple physicians delineated the gross tumor volume (GTV) and normal structures in planning CT images and only GTV in CBCT images. Manual contours were mapped from planning CT to CBCTs using small deformation, inverse consistent linear elastic (SICLE) algorithm for two scans in each patient. Two physicians reviewed and rated the DIR-mapped (auto) and manual GTV contours as clinically acceptable (CA), clinically acceptable after minor modification (CAMM) and unacceptable (CU). Mapped normal structures were visually inspected and corrected if necessary, and used to override tissue density for dose calculation. CTV (6mm expansion of GTV) and PTV (5mm expansion of CTV) were created. VMAT plans were generated using the DIR-mapped contours to deliver 66 Gy in 33 fractions with 95% and 100% coverage (V66) to PTV and CTV, respectively. Plan evaluation for V66 was based on manual PTV and CTV contours. Results: Mean PTV V66 was 84% (range 75% – 95%) and mean CTV V66 was 97% (range 93% – 100%) for CAMM scored plans (12 plans); and was 90% (range 80% – 95%) and 99% (range 95% – 100%) for CA scored plans (7 plans). The difference in V66 between CAMM and CA was significant for PTV (p = 0.03) and approached significance for CTV (p = 0.07). Conclusion: The quality of DIR-mapped contours directly impacted the plan quality for 4DCBCT-based adaptation. Larger safety margins may be needed when planning with auto contours for IGART with 4DCBCT images. Reseach was supported by NIH P01CA116602.

60 APPLIED LIFE SCIENCES↗

Development of Streamlined Nuclear Safety Analysis Tool for Spent Nuclear Fuel Applications

To understand the changing nuclear and mechanical characteristics of spent nuclear fuel (SNF) or used nuclear fuel (UNF) and the different storage, transportation, and disposal systems at various stages within the waste management system, different types of analyses are required. These analyses require the use of assorted tools and numerous types of data. Using the appropriate modeling and simulation (M&S) parameters and selecting from the diversity of analytic tools to conduct SNF analyses can be a tedious, error-prone, and time-consuming undertaking for analysts and reviewers alike. A new, integrated data and analysis system was designed to simplify and automate performance of accurate, efficient evaluations for characterizing the input to the overall U.S. nuclear waste management system—the UNF-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). A relational database has been assembled to provide a standard means by which UNF-ST&DARDS can succinctly store and retrieve M&S parameters for specific SNF analysis. A library of various analysis model templates is used to communicate M&S parameters for the most appropriate M&S application. A process manager facilitates performance of actual as-loaded, assembly-specific, and cask-specific evaluations. Interactive visualization capabilities facilitate data analysis and results interpretation. To date, UNF-ST&DARDS has completed (1) explicit depletion and decay analysis of every fuel assembly (~245 000) discharged from commercial U.S. reactors through June 2013, with 13 cooling time steps (results include isotopic compositions for 142 isotopes, and radiation and thermal source terms); (2) SNF radiation dose rate evaluations at 1 m for all the fuel assemblies discharged through June 2013; and (3) criticality, shielding, thermal, and containment analyses of hundreds of loaded casks. In conclusion, UNF-ST&DARDS also provides various automated report generation capabilities with dynamic figure and table update capabilities based on changes to the Unified Database.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-J-195: Quantification of Rotations and Deformations in Head and Heck Radiotherapy

Purpose: To quantify the magnitude of patient rotations and deformations over the course of head and neck radiotherapy. Methods: 45 CBCT images acquired weekly were selected retrospectively from 5 head and neck cancer patients. CBCT images were registered to the corresponding planning CT images using translation, rigid-body, and cubic B-spline deformable transformations. Elastix ( elastix.isi.uu.nl ), an open-source public domain registration algorithm, was used for all registrations with mutual information as similarity metric and gradient descent as optimization. Four-level multiresolution approach was employed with 2 cm B-spline grid spacing at the finest resolution. Registration qualities were visually verified. Rotational occurrences were quantified from the rigid-body registrations. The magnitude of deformations in planning target volumes (PTV) and organs were quantified from the deformation vector fields with rigid registrations as baseline. Results: The measured rotations (mean±std) were 1.0±1.0 deg, - 0.3±1.0 deg, and 0.1±0.8 deg in the sagittal, coronal, and axial plains respectively. The estimated magnitudes of deformations (mean±std) were 3.4±2.1 mm for PTVs, 2.9±1.2 mm for parotid glands, 2.8±1.2 mm for mandible, and 2.2±1.1 mm for spinal cord. The overall deformation in the body contour was 4.3±4.3 mm. The organ spatial deviation due to rotation was small and approximately 8.4% of that from deformations. Results varied among patients. Conclusion: Rotations occurred about 1.0 deg (1SD) in the H'N area. Daily geometric deviation of target volumes was considerable and mainly from tissue deformation than rotations. Proper safety margin is necessary for adequate target coverage. Online plan adaptation may mitigate the daily differences between the plan and actual patient poses. Partially supported by a grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Identification and Preservation of Arm Lymphatic System in Axillary Dissection for Breast Cancer to Reduce Arm Lymphedema Events: A Randomized Clinical Trial

Background: Controversy in axillary reverse mapping in axillary lymph node dissection (ALND) possibly results from incomplete recognition of the arm lymphatic system (ALS) and its compromise to oncological safety. The iDEntification and Preservation of ARm lymphaTic system (DEPART) technique facilitates complete identification of ALS; therefore, its use may decrease the occurrence of arm lymphedema. This study aimed to examine the arm lymphedema rate, locoregional recurrence, and feasibility to perform DEPART in ALND. Methods: Patients from February 2013 to October 2017 from two tertiary referral centers were randomly assigned to two groups. In the study group, indocyanine green and methylene blue (MB) were utilized to identify arm sentinel nodes, and 0.1 ml MB was injected into the arm sentinel nodes to reveal the subsequent-echelon nodes and lymphatics. Gross arm lymph nodes were examined by intraoperative partial frozen section and were removed if positive. Arm lymphedema, local recurrence, regional recurrence, and distant metastasis were recorded at different follow-up examinations. Results: Arm sentinel nodes were identified in 573 (83.2%) patients. Subsequent-echelon nodes and lymphatics were visualized in 558 (97.4%) patients. Metastatic arm nodes were identified in 38 (6.8%) patients. The arm lymphedema rate was 3.3% (18/543) in the study group versus 15.3% (99/648) in the control group (p < 0.001) after 37-month median follow-up. Regional recurrence showed no difference between the two groups (1.4% and 1.2%, respectively) (p = 0.392). Conclusions: DEPART can benefit breast cancer patients who undergo ALND, reducing the arm lymphedema rate without adversely affecting the morbidity of regional recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Images for Checked and Carry-on Baggage and Cargo Screening

The current X-ray systems used by airport security personnel for the detection of contraband, and objects such as knives and guns that can impact the security of a flight, have limited effect because of the limited display quality of the X-ray images. Since the displayed images do not possess optimal contrast and sharpness, it is possible for the security personnel to miss potentially hazardous objects. This problem is also common to other disciplines such as medical Xrays, and can be mitigated, to a large extent, by the use of state-of-the-art image processing techniques to enhance the contrast and sharpness of the displayed image. The NASA Langley Research Center's Visual Information Processing Group has developed an image enhancement technology that has direct applications to this problem of inadequate display quality. Airport security X-ray imaging systems would benefit considerably by using this novel technology, making the task of the personnel who have to interpret the X-ray images considerably easier, faster, and more reliable. This improvement would translate into more accurate screening as well as minimizing the screening time delays to airline passengers. This technology, Retinex, has been optimized for consumer applications but has been applied to medical X-rays on a very preliminary basis. The resultant technology could be incorporated into a new breed of commercial x-ray imaging systems which would be transparent to the screener yet allow them to see subtle detail much more easily, reducing the amount of time needed for screening while greatly increasing the effectiveness of contraband detection and thus public safety.

Woodell, Glenn↗

Enhanced Images for Checked and Carry-on Baggage and Cargo Screening

The current X-ray systems used by airport security personnel for the detection of contraband, and objects such as knives and guns that can impact the security of a flight, have limited effect because of the limited display quality of the X-ray images. Since the displayed images do not possess optimal contrast and sharpness, it is possible for the security personnel to miss potentially hazardous objects. This problem is also common to other disciplines such as medical X-rays, and can be mitigated, to a large extent, by the use of state-of-the-art image processing techniques to enhance the contrast and sharpness of the displayed image. The NASA Langley Research Centers Visual Information Processing Group has developed an image enhancement technology that has direct applications to this problem of inadequate display quality. Airport security X-ray imaging systems would benefit considerably by using this novel technology, making the task of the personnel who have to interpret the X-ray images considerably easier, faster, and more reliable. This improvement would translate into more accurate screening as well as minimizing the screening time delays to airline passengers. This technology, Retinex, has been optimized for consumer applications but has been applied to medical X-rays on a very preliminary basis. The resultant technology could be incorporated into a new breed of commercial x-ray imaging systems which would be transparent to the screener yet allow them to see subtle detail much more easily, reducing the amount of time needed for screening while greatly increasing the effectiveness of contraband detection and thus public safety.

Woodell, Glen↗

AN OVERVIEW OF REDUCED ORDER MODELING TECHNIQUES FOR SAFETY APPLICATIONS

The RISMC project is developing new advanced simulation-based tools to perform Computational Risk Analysis (CRA) for the existing fleet of U.S. nuclear power plants (NPPs). These tools numerically model not only the thermal-hydraulic behavior of the reactors primary and secondary systems, but also external event temporal evolution and component/system ageing. Thus, this is not only a multi-physics problem being addressed, but also a multi-scale problem (both spatial, µm-mm-m, and temporal, seconds-hours-years). As part of the RISMC CRA approach, a large amount of computationally-expensive simulation runs may be required. An important aspect is that even though computational power is growing, the overall computational cost of a RISMC analysis using brute-force methods may be not viable for certain cases. A solution that is being evaluated to assist the computational issue is the use of reduced order modeling techniques. During the FY2015, we investigated and applied reduced order modeling techniques to decrease the RISMC analysis computational cost by decreasing the number of simulation runs; for this analysis improvement we used surrogate models instead of the actual simulation codes. This article focuses on the use of reduced order modeling techniques that can be applied to RISMC analyses in order to generate, analyze, and visualize data. In particular, we focus on surrogate models that approximate the simulation results but in a much faster time (microseconds instead of hours/days).

97 MATHEMATICS AND COMPUTING↗

A BRIEF DESCRIPTION OF THE SMALL-SCALE SAFETY TESTING SYSTEMS AT LAWRENCE LIVERMORE NATIONAL LABORATORY

Small-scale sensitivity testing is important for determining material response to various stimuli including impact, friction, and static spark. These tests, briefly described below, provide parameters for safety in handling. ERL Type 12 drop hammer equipment at LLNL, shown in Figure 1, was used to determine the impact sensitivity. The equipment includes a 2.5-kg drop weight, a striker (upper anvil, 2.5 kg for solid samples and 1.0 kg for liquid samples), a bottom anvil, a microphone sensor, and a peakmeter. For each drop, sample (35 mg for solid or 45 microliter for liquid) is placed on the bottom anvil surface and impacted by the drop weight from different heights. Signs of reactions upon impact are observed and recorded. These signs include noises, flashes or sparks, smoke, pressure, gas emissions, temperature rise due to exothermic reaction, color change of the sample, and changes to the anvil surface (noted by inspection). For solid samples, a 'GO' was defined as a microphone sensor (for noise detection) response of {ge} 1.3 V as measured by a peakmeter. The higher the DH{sub 50} values, the lower the impact sensitivity. The method used to calculate DH{sub 50} values is the 'up and down' or Bruceton method. PETN and RDX have impact sensitivities of 15 and 35 cm, respectively. TATB has impact sensitivity more than 177 cm. For liquid samples, a 'GO' was determined by the noise levels as measured by the peakmeter, appearance of flashes, temperature rise of the anvil, and visual inspection of the anvil surface. Two liquid samples TMETN and FEFO have impact sensitivities of 14 and 32 cm, respectively. Figure 2 shows a 'GO' event observed during the impact sensitivity test; flashes appeared as the drop weight impacted the sample. A BAM friction sensitivity test machine, as shown in Figure 3, was used to determine the frictional sensitivity. The system uses a fixed porcelain pin and a movable porcelain plate that executes a reciprocating motion. Weight affixed to a torsion arm allows for a variation in applied force between 0.5 kg to 36.0 kg. The relative measure of the frictional sensitivity of a material is based upon the smallest load (kg) at which reaction occurs for a 1-in-10 series of attempts. The lower the load values, the higher the frictional sensitivity. PETN has a frictional sensitivity of 6.4 kg. The static spark machine at LLNL is used to evaluate the electrostatic discharge hazards (human ESD) associated with the handling of explosives. The machine was custom-built almost 30 years ago and consists of a capacitor bank (up to 20,000 pF), a voltage meter, and a discharge circuit, as shown in Figure 4. An adjustable resistor up to 510 ohms (chosen to simulate human body) is wired to the discharge circuit. A 5-mg sample is placed in a Teflon washer sealed to a steel disc and covered with a Mylar tape. High static voltage (up to 10 kv) is applied and discharged to the sample. Evidence of reaction is judged from the condition of Mylar tape, smokes, and color change of the sample. Voltage, capacitance, and resistance can be adjusted to achieve the desired static energy. The results obtained are expressed as a zero in 10 or one-in-ten at a specific voltage and joules. One reaction in ten trials at {le} 0.25 joules is considered spark-sensitive. Primary explosives show reaction at 0.1 joule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test and Evaluation Metrics of Crew Decision-Making And Aircraft Attitude and Energy State Awareness

NASA has established a technical challenge, under the Aviation Safety Program, Vehicle Systems Safety Technologies project, to improve crew decision-making and response in complex situations. The specific objective of this challenge is to develop data and technologies which may increase a pilot's (crew's) ability to avoid, detect, and recover from adverse events that could otherwise result in accidents/incidents. Within this technical challenge, a cooperative industry-government research program has been established to develop innovative flight deck-based counter-measures that can improve the crew's ability to avoid, detect, mitigate, and recover from unsafe loss-of-aircraft state awareness - specifically, the loss of attitude awareness (i.e., Spatial Disorientation, SD) or the loss-of-energy state awareness (LESA). A critical component of this research is to develop specific and quantifiable metrics which identify decision-making and the decision-making influences during simulation and flight testing. This paper reviews existing metrics and methods for SD testing and criteria for establishing visual dominance. The development of Crew State Monitoring technologies - eye tracking and other psychophysiological - are also discussed as well as emerging new metrics for identifying channelized attention and excessive pilot workload, both of which have been shown to contribute to SD/LESA accidents or incidents.

Bailey, Randall E.↗

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record↗

PBX-9501 High Explosive Infrared Thermography Test Report

High explosive safety requirements put in place by the Department of Defense necessitate that Los Alamos National Laboratory verify that high melting explosive-based plastic bonded explosive 9501 will not present a health or safety risk to personnel when exposed to various accident scenarios. The JT5R-14C test is being developed to validate this requirement in a scenario where PBX-9501 is exposed to a hydrocarbon fuel fire. Preliminary testing is required to establish benchmark data on the burning characteristics of PBX-9501. The PBX-9501 High Explosive Infrared Thermography test was designed to provide the benchmark burning characteristics of PBX-9501 in a simulated fuel fire environment using propane burners as a fuel source. The PBX-9501-HEIT was successfully completed using a 20.32 cm tall cylindrical sample of PBX-9501 with a radius of 10.16 cm, a volume of 6,589.63 cm 3 , a density of 1.83 g/cm 3 , and a mass of 1.2 kg. The PBX-9501-HEIT test was captured and recorded video sequence using a Telops Inc., Multispectral Infrared camera. The infrared sequence was reviewed to identify key events throughout the test and serves as a visual tool to cross reference against future testing to aid in the identification of PBX-9501 high explosive ignition and deflagration characteristics. The data obtained in the thermographic sequence confirmed that the temperatures emitted by the PBX-9501 were higher than the temperatures of the propane burner ignition source. The propane burner flames had a temperature range of 700-850 °C. The cylindrical sample of PBX-9501 burned at an average temperature of 1000-1200 °C on the surface with off-gassing temperatures averaging 1100-1250 °C. The heat map of the PBX-9501 obtained through the test was between 250-550 °C higher than the propane gas temperatures. The temperature differential between the PBX-9501 and the propane flame allowed for the identification of key burning features.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dispersion curve regression – assisted wideband local wavenumber analysis for characterizing three-dimensional (3D) profile of hidden corrosion damage

Corrosion as common damage in civil, petrochemical, nuclear, and aerospace structures affects the integrity and safety of the structures and may lead to catastrophic failures. This paper presents dispersion curve regression-assisted local wavenumber analysis method, which can analyze the time–space wavefield containing wideband information of wave-damage interaction and further extract the structural information carried by such wavefield for characterizing hidden corrosion damage in an isotropic plate. To acquire the time–space wavefield, a noncontact scanning laser Doppler vibrometer is used. In our analysis method, the acquired time–space wavefield is firstly processed to generate a local wavenumber function. The derived wavenumber function is further analyzed with a dispersion curve regression step, which searches in a set of theoretical frequency-wavenumber dispersion curves for different plate thicknesses and identifies the optimal plate thickness whose theoretical curve best matches the frequency-wavenumber relation contained in the local wavenumber function. By this means, a 3D profile including both in plane and thickness dimensions of the structure can be constructed for corrosion visualization and quantification. The experimental study demonstrates that our method can quantify the profile of hidden uniform corrosion in metal plates in terms of its in-plane shape and size as well as its out-of-plane depth in the subwavelength scale. Moreover, compared to previous Lamb wave-based corrosion inspection methods, our technique allows for noncontact 3D characterization of hidden corrosion from a far distance to the structure. Finally, we believe this work will inspire new 3D damage quantification methods that are based on wavefield analysis as well as enable potential applications for the quantification of hidden corrosion in civil, petrochemical, nuclear, and aerospace structures.

42 ENGINEERING↗

A Section 106 Evaluation of Building CP-1, Area 6, Nevada National Security Site, Nye County, Nevada

On December 17, 2015, the National Nuclear Security Administration Nevada Field Office (NNSA/NFO) vacated Building CP-1 (Building 06-CP-1) on the Nevada National Security Site (NNSS) in Nye County, Nevada. Starting in 1951, nearly all nuclear tests during the Cold War were controlled from this building on the facility, known as the Nevada Test Site for most of its years of operation. The test site was renamed the NNSS in 2010. CP-1 was the command and control center where decisions about NNSS activities were sought and made; where authorization for movements about the areas forward (north) of Mercury base camp were coordinated, granted or declined, and monitored; and where problems and emergencies in the forward areas were communicated and relayed to the appropriate agencies for solution. Some of the testing duties for the Control Point included the timing and firing of nuclear tests, air operations, security, communications, weather monitoring, and radiation safety. During tests, communications were maintained through various channels to receive and pass instructions or information to the numerous testing operations, to Washington, D.C., the national laboratories, and overhead aircraft monitoring the tests. At one time, the Security Control Center, a Class A Weather Station, and the Radiation Safety Headquarters were located in CP-1, which also contained a cafeteria, a dining area, and bunk rooms. This survey was prompted by recognition that closure of the building in place creates a situation where CP-1 is vulnerable to decay in its present and unused condition. Activities at CP-1 have been reduced gradually over time since the end of nuclear testing in 1992. The Area of Potential Effects (APE) was determined by NNSA/NFO to be a two-acre area historically considered the space directly associated with CP-1 and available to CP-1 personnel for use. The APE is bounded on the south by an unnamed main paved road into the guarded Control Point area, on the west by the edge of the parking lot for adjacent Building CP-9, on the east by the edge of the bladed cut-and-fill terrace for CP-1, and on the north by a barbed wire security fence (Figure 2). All of this lot is either bladed or covered with asphalt. Contained within the lot are eight Accessary Resources (AR) which are much more closely aligned with CP-1 than with adjacent buildings. AR are defined by the Nevada State Historic Preservation Office (SHPO) (2013) as “…related but subordinate to the principal building. Accessory resources would not exist were it not for the principal resource.” The Visual APE was determined by NNSA/NFO to be the same as the APE used for intensive survey because no exterior modifications to the resource are anticipated. The APE is located in Section 34 T11S R53E MDBM (projected) within the NNSS base called the Control Point in Area 6. It is on the 1986 Yucca Lake USGS 7.5 min. series topographic quadrangle. The Desert Research Institute (DRI) surveyed the APE with the assistance of National Security Technologies, LLC (NSTec), resulting in recordation and evaluation of CP-1 (SHPO Resource Number B14490) and eight accessory resources (AR1-AR8). This recording of CP-1 was done in three sessions. Copies of the building form and report are on file at Nevada Cultural Resources Information System (NVCRIS), DRI, and with the NNSA/NFO, Las Vegas, Nevada. Control Point refers to the support facilities of which Building CP-1, with its 126 rooms, is the most important part (Campbell et al. 1983:165). CP-1 refers to the entire building but it also is the designation for the first phase of construction, i.e. the original building. There were three major subsequent phases of additions to the building. The first two were called CP-1A (the east wing) and CP-1B (the west wing with the new War Room). A final phase filled in the hyphen between CP-1 and CP-1B with a Field Office. For convenience this last phase is called CP-1C in this report. Hence, CP-1 can refer either the entire building or to the first phase of the building exclusive of additions. The context makes clear which of the two meanings is intended in the various sections of this report. There were also two minor expansions consisting of a small battery room and a shelter for an emergency exit.

54 ENVIRONMENTAL SCIENCES↗