Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo

Arrays of electrodes for recording and stimulating the brain are used throughout clinical medicine and basic neuroscience research, yet are unable to sample large areas of the brain while maintaining high spatial resolution because of the need to individually wire each passive sensor at the electrode-tissue interface. To overcome this constraint, we developed new devices that integrate ultrathin and flexible silicon nanomembrane transistors into the electrode array, enabling new dense arrays of thousands of amplified and multiplexed sensors that are connected using fewer wires. We used this system to record spatial properties of cat brain activity in vivo, including sleep spindles, single-trial visual evoked responses and electrographic seizures. We found that seizures may manifest as recurrent spiral waves that propagate in the neocortex. As a result, the developments reported here herald a new generation of diagnostic and therapeutic brain-machine interface devices.

high spatial resolution↗

Flexible Vanadium Dioxide Photodetectors for Visible to Longwave Infrared Detection at Room Temperature

Abstract Flexible optoelectronics is a rapidly growing field, with a wide range of potential applications. From wearable sensors to bendable solar cells, curved displays, and curved focal plane arrays, the possibilities are endless. The criticality of flexible photodetectors for many of these applications is acknowledged, however, devices that are demonstrated thus far are limited in their spectral range. In this study, flexible photodetectors are demonstrated using a VO x nanoparticle ink, with an extremely broad operating wavelength range of 0.4 to 20 µm. This ink is synthesized using a simple and scalable wet‐chemical process. These photodetectors operate at room temperature and exhibit minimal variance in performance even when bent at angles of up to 100 ° at a bend radius of 6.4 mm. In addition, rigorous strain testing of 100 bend and release cycles revealed a photoresponse with a standard deviation of only 0.55%. This combination of mechanical flexibility, wide spectral response, and ease of fabrication makes these devices highly desirable for a wide range of applications, including low‐cost wearable sensors and hyperspectral imaging systems.

36 MATERIALS SCIENCE↗

A facile processing way of silica needle arrays with tunable orientation by tube arrays fabrication and etching method

A simple method to fabricate silica micro/nano-needle arrays (SNAs) is presented based on tube-etching mechanism. Using silica fibers as templates, highly aligned and free-standing needle arrays are created over large area by simple processes of polymer infiltration, cutting, chemical etching and polymer removal. Their sizes and orientations can be arbitrarily and precisely tuned by simply selecting fiber sizes and the cutting directions, respectively. This technique enables the needle arrays with special morphology to be fabricated in a greatly facile way, thereby offers them the potentials in various applications, such as optic, energy harvesting, sensors, etc. As a demonstration, the super hydrophobic property of PDMS treated SNAs is examined. - Graphical abstract: Silica needle arrays are fabricated by tube arrays fabrication and etching method. They show super hydrophobic property after being treated with PDMS.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Double-gated Si NW FET sensors: Low-frequency noise and photoelectric properties

The transport, noise, and photosensitivity properties of an array of silicon nanowire (NW) p{sup +}-p-p{sup +} field-effect transistors (FETs) are investigated. The peculiarities of photosensitivity and detectivity are analyzed over a wide spectrum range. The absorbance of p-Si NW shifts to the short wavelength region compared with bulk Si. The photocurrent and photosensitivity reach increased values in the UV range of the spectrum at 300 K. It is shown that sensitivity values can be tuned by the drain-source voltage and may reach record values of up to 2–4 A/W at a wavelength of 300 nm at room temperature. Low-frequency noise studies allow calculating the photodetectivity values, which increase with decreasing wavelength down to 300 nm. We show that the drain current of Si NW biochemical sensors substantially depends on pH value and the signal-to-noise ratio reaches the high value of 10{sup 5}. Increasing pH sensitivity with gate voltage is revealed for certain source-drain currents of pH-sensors based on Si NW FETs. The noise characteristic index decreases from 1.1 to 0.7 with the growth of the liquid gate voltage. Noise behavior is successfully explained in the framework of the correlated number-mobility unified fluctuation model. pH sensitivity increases as a result of the increase in liquid gate voltage, thus giving the opportunity to measure very low proton concentrations in the electrolyte medium at certain values of the liquid gate voltage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Precision, High Frequency Printed Antennas

An emerging trend in advanced manufacturing is printed electronics and sensors. The ability to print customized electronics and sensors integrated into functional packages is a growing need within a variety of growing markets such as smart manufacturing, internet of things (IoT), and the small satellite industry. Both Oak Ridge National Laboratory (ORNL) and the MITRE Corporation have seedling research efforts evaluating the potential for future printed electronic systems. High frequency, wide-bandwidth phased array antennas (i.e. >45 GHz) open the door to new applications. However, such sensors require currently prohibitively small feature sizes for commercial 3D printing technologies along with increasing challenges with connecting the driving electronics to such features. An additional finding with related advanced manufacturing challenges is the rapid production of 3D additive connectors for integration with commercial printed circuit boards (PCBs), primarily for advanced in-circuit inspection techniques. This work is developing additive manufacturing processes for producing connected and conductive fine scale 3D features. The primary focus was on aerosol-jet printing (AJP), which has a small minimum resolution (<50 µm) but is traditionally printed flat with small height/width aspect ratios <<1, and developing controls to enable fully 3D, high aspect ratio, and unsupported features. In Phase 1 of this effort, baselines of process performance were characterized, and test coupons produced for both ultra-high frequency antennas and microstructures to support reverse engineering of PCBs. In Phase 2, these efforts will be extended for system demonstration of ultra-high frequency antenna arrays, as well as reverse engineering circuitry for dense PCBs.

42 ENGINEERING↗

A novel occupancy detection solution using low-power IR-FPA based wireless occupancy sensor

Significant energy savings can be achieved by operating heating, ventilation, and air conditioning control systems with indoor occupancy measurement information. This paper presents a novel plug-and-play occupancy sensing method which will enable temporal minimization of building energy consumption to meet building usage behavior without privacy concerns. The proposed wireless occupancy sensing platform is based on long-wave infra-red (LWIR) focal-plane arrays (FPAs), or thermal imagers, that detect thermal energy rather than visible light. We developed an advanced sensor package consisting of multiple thermal imagers with low-cost optical enhancements to increase field of view and increase sensitivity to occupant detection (filtering building clutter). These imagers can be coupled with radio frequency and ultrasonic-based radar to enhance data collection at key occupant zone boundaries to improve accuracy. Standard filtering and estimation techniques from the image processing and computer vision communities are introduced to overcome the accuracy issues suffered by traditional PIR based sensing, especially when occupants remain relatively still. Accurate low-level counting of individuals can be achieved with minimal impact on privacy. As a result, the proposed occupancy detection method can work as a retrofit to enable real-time understanding of the building operational state and usage behavior. Sensor data obtained from real test building zones was used to test the efficacy of the method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of the Mid-Frequency Arrays for Advanced ACTPol

The Advanced ACTPol upgrade on the Atacama Cosmology Telescope aims to improve the measurement of the cosmic microwave background anisotropies and polarization, using four new dichroic detector arrays fabricated on 150-mm silicon wafers. These bolometric cameras use AlMn transition-edge sensors, coupled to feedhorns with orthomode transducers for polarization sensitivity. The first deployed camera is sensitive to both 150 and 230 GHz. Here, we present the laboratory characterization of the thermal parameters and optical efficiencies for the two newest fielded arrays, each sensitive to both 90 and 150 GHz. We provide assessments of the parameter uniformity across each array with evaluation of systematic uncertainties. Lastly, we show the arrays’ initial performance in the field.

42 ENGINEERING↗

Silicon photomultiplier characterization for the GlueX barrel calorimeter

GlueX is a new detector being constructed at Jefferson Laboratory to study gluonic excitations and confinement via the detection of exotic meson states. The hermetic detector includes a barrel calorimeter where the photodetectors must operate in a high magnetic field exceeding 0.5 T. After extensive tests with a variety of sensors, the chosen photodetector will be a custom silicon photomultiplier (SiPM) array manufactured by Hamamatsu Corporation. This paper will focus on the characterization of the first 80 production samples of these SiPMs, including dark rate, photodetection efficiency (PDE), crosstalk, response uniformity and radiation tolerance.

Calorimeter↗

Atomically engineered epitaxial anatase TiO 2 metal-semiconductor field-effect transistors

Here, anatase TiO 2 is a promising material for a vast array of electronic, energy, and environmental applications, including photocatalysis, photovoltaics, and sensors. A key requirement for these applications is the ability to modulate its electrical properties without dominant dopant scattering and while maintaining high carrier mobility. Here, we demonstrate the room temperature field-effect modulation of the conducting epitaxial interface between anatase TiO 2 and LaAlO 3 (001), which arises for LaO-terminated LaAlO 3 , while the AlO 2- terminated interface is insulating. This approach, together with the metal-semiconductor field-effect transistor geometry, naturally bypasses the gate/channel interface traps, resulting in a high field-effect mobility μ FE of 3.14 cm 2 (V s) –1 approaching 98% of the corresponding Hall mobility μ Hall . Accordingly, the channel conductivity is modulated over 6 orders of magnitude over a gate voltage range of ~4 V.

36 MATERIALS SCIENCE↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A dedicated mirror-magnet experiment to study quench characteristics and dependencies in $Nb_{3}Sn$ coils and explore improvements of diagnostics capabilities

A single Nb3Sn short quadrupole coil in a mirror-magnet configuration was employed to investigate a wide range of phenomena and to serve as test-bed for diagnostics developments. A configurable array of spot-heaters was installed on the inner coil surface for control of induced quench conditions. Several different quench antenna arrays were positioned along the coil inner surface, and included significant sensor overlap for assessment of their relative efficiency and operation. Multiple acoustic sensors were placed on the pole and at coil ends. Optical fibers in grid configurations were put in different places on the coil and magnet for strain assessment, along with standard resistive strain gauges. Current spikes in the magnet circuit were monitored. This plethora of instrumentation aimed to support investigations on induced and spontaneous quenches, among other goals, and was supplemented by standard voltage-tap-based measurements. Voltage tap data of induced quenches from various spot-heater configurations was investigated for similarities to voltage development in spontaneous quenches. Quench antennas provided insights about current redistribution in the quenching coil and coil splices. The Quench Current-boosting Device was applied and the effect on coil training examined. This paper describes motivations behind the research, the overall test setup and main results.

Stoynev, Stoyan [Fermilab]↗

OpenPET Hardware, Firmware, Software, and Board Design Files

OpenPET is an open source, flexible, high-performance, and modular data acquisition system for a variety of applications. The OpenPET electronics are capable of reading analog voltage or current signals from a wide variety of sensors. The electronics boards make extensive use of field programmable gate arrays (FPGAs) to provide flexibility and scalability. Firmware and software for the FPGAs and computer are used to control and acquire data from the system. The command and control flow is similar to the data flow, however, the commands are initiated from the computer similar to a tree topology (i.e., from top-to-bottom). Each node in the tree discovers its parent and children, and all addresses are configured accordingly. A user (or a script) initiates a command from the computer. This command will be translated and encoded to the corresponding child (e.g., SB, MB, DB, etc.). Consecutively, each node will pass the command to its corresponding child(ren) by looking at the destination address. Finally, once the command reaches its desired destination(s) the corresponding node(s) execute(s) the command and send(s) a reply, if required. All the firmware, software, and the electronics board design files are distributed through the OpenPET website (http://openpet.lbl.gov).

Abu-Nimeh, Faisal↗

bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

DNA translocation through an array of kinked nanopores

Synthetic solid-state nanopores are being intensively investigated as single-molecule sensors for detection and characterization of DNA, RNA and proteins. This field has been inspired by the exquisite selectivity and flux demonstrated by natural biological channels and the dream of emulating these behaviours in more robust synthetic materials that are more readily integrated into practical devices. So far, the guided etching of polymer films, focused ion-beam sculpting, and electron-beam lithography and tuning of silicon nitride membranes have emerged as three promising approaches to define synthetic solid-state pores with sub-nanometre resolution. These procedures have in common the formation of nominally cylindrical or conical pores aligned normal to the membrane surface. Here we report the formation of 'kinked' silica nanopores, using evaporation-induced self-assembly, and their further tuning and chemical derivatization using atomic-layer deposition. Compared with 'straight through' proteinaceous nanopores of comparable dimensions, kinked nanopores exhibit up to fivefold reduction in translocation velocity, which has been identified as one of the critical issues in DNA sequencing. Additionally, we demonstrate an efficient two-step approach to create a nanopore array exhibiting nearly perfect selectivity for ssDNA over dsDNA. We show that a coarse-grained drift-diffusion theory with a sawtooth-like potential can reasonably describe the velocity and translocation time of DNA through the pore. By control of pore size, length and shape, we capture the main functional behaviours of protein pores in our solid-state nanopore system.

36 MATERIALS SCIENCE↗

Multi-energy x-ray imaging and sensing for diagnostic and control of the burning plasma

New diagnostic and sensor designs are needed for future burning plasma (BP) fusion experiments, having good space and time resolution and capable of prolonged operation in the harsh BP environment. We evaluate the potential of multi-energy x-ray imaging with filtered detector arrays for BP diagnostic and control. Experimental studies show that this simple and robust technique enables measuring with good accuracy, speed, and spatial resolution the T{sub e} profile, impurity content, and MHD activity in a tokamak. Applied to the BP this diagnostic could also serve for non-magnetic sensing of the plasma position, centroid, ELM, and RWM instability. BP compatible x-ray sensors are proposed using 'optical array' or 'bi-cell' detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Properties of Low Tc AlMn TES

Low Tc AlMn transition-edge sensors (TESs) have been developed as sensitive thermometers for the Q-Array, which will use superconducting targets to measure the coherent elastic neutrino nucleus scattering spectrum in the RICOCHET experiment. The TESs are made of manganese-doped aluminum with a titanium and gold antioxidation layer. A prototype TES thermometer consists of two TESs in parallel, an input gold pad in metallic contact with the TESs and an output gold pad and gold thermal link meanders, which are each designed to control the flow of heat through the TESs. We have fabricated and measured low TC AlMn TES chips with or without thermal flow control structures. We present TC measurements of the TESs after the initial fabrication and further TC tuning by re-heating and summarize the thermal property studies of the prototype TES thermometer by measuring I-V curves and complex impedance.

Coherent elastic neutrino nucleus scattering, Cryo↗

Acoustic Event Location and Background Noise Characterization on a Free Flying Infrasound Sensor Network in the Stratosphere

We present that a variety of Earth surface and atmospheric sources generate low frequency sound waves that can travel great distances. Despite a rich history of ground-based sensor studies, very few experiments have investigated the prospects of free floating microphone arrays at high altitudes. However, recent initiatives have shown that such networks have very low background noise and may sample an acoustic wave field that is fundamentally different than that at Earth’s surface. The experiments have been limited to at most two stations at altitude, making acoustic event detection and localization difficult. We describe the deployment of four drifting microphone stations at altitudes between 21 and 24 km above sea level. The stations detected one of two regional ground-based chemical explosions as well as the ocean microbarom while traveling almost 500 km across the American Southwest. The explosion signal consisted of multiple arrivals; signal amplitudes did not correlate with sensor elevation or source range. The waveforms and propagation patterns suggest interactions with gravity waves in the 35-45 km altitude. A sparse network method that employed curved wave front corrections was able to determine the backazimuth from the free flying network to the acoustic source. Episodic signals similar to those seen on previous flights in the same region were noted, but their source remains unclear. Lastly, background noise levels were commensurate with those on infrasound stations in the International Monitoring System below 2 seconds.

58 GEOSCIENCES↗