Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

The Advanced Topographic Laser Altimeter System (ATLAS) for NASA's Ice Cloud and Land Elevation Satellite-2 (ICESat-2): Design, Development, and On-Orbit Performance

Conceived in response to the 2007 Earth Science Decadal Survey, ATLAS/ICESat-2 was launched on September 15, 2018 to a polar orbit and has been operating continuously since. The ATLAS instrument is a continuously-operating direct-detection pulsed laser altimeter utilizing a solid-state 532-nm laser source operating at a 10-kHz pulse repetition rate along with a diffractive optic to illuminate six 15-meter spots on the Earth's surface with each laser pulse. An 80-cm receiver telescope fiber-coupled to segmented photomultipliers provides single-photon detection capability. This presentationr will present an overview of the ATLAS instrument design, some challenges encountered during development, and initial results from orbit.

Lidar↗

Effect of sample thickness on 511 keV single Compton-scattered gamma rays

Gamma backscattering experiments were performed on metal foils varying some geometric parameters of the assembly. A collimated beam from a {sup 22}Na source impinges on aluminum sheets of dimensions 33.3×20.4×1.0 cm{sup 3} and iron sheets of (33.2×20.4×0.2) cm{sup 3}. The backscattered photons are detected by a 3″×3″ CsI scintillator detector placed at 90° to the incident beam. The experimental results show that thickness of metalic samples can be determined with a very small uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the Short-Pulse X-ray Project (SPX) at the Advanced Photon Source (APS)

The Advanced Photon Source Upgrade project (APS-U) at Argonne includes implementation of Zholents’* deflecting cavity scheme for production of short x-ray pulses. This is a joint project between Argonne National Laboratory, Thomas Jefferson National Laboratory, and Lawrence Berkeley National Laboratory. This paper describes performance characteristics of the proposed source and technical issues related to its realization. Ensuring stable APS storage ring operation requires reducing quality factors of these modes by many orders of magnitude. These challenges reduce to those of the design of a single-cell SC cavity that can achieve the desired operating deflecting fields while providing needed damping of all these modes. The project team is currently prototyping and testing several promising designs for single-cell cavities with the goal of deciding on a winning design in the near future. Here

43 PARTICLE ACCELERATORS↗

Magnetic two-photon scattering and two-photon emission - Cross sections and redistribution functions

The magnetic two-photon scattering cross section is discussed within the framework of QED, and the corresponding scattering redistribution function for this process and its inverse, as well as the scattering source function are calculated explicitly. In a similar way, the magnetic two-photon emission process which follows the radiative excitation of Landau levels above ground is calculated. The two-photon scattering and two-photon emission are of the same order as the single-photon magnetic scattering. All three of these processes, and in optically thick cases also their inverses, are included in radiative transport calculations modeling accreting pulsars and gamma-ray bursters. These processes play a prominent role in determining the relative strength of the first two cyclotron harmonics, and their effects extend also to the higher harmonics.

Alexander, S. G.↗

Demonstration of Single-Crystal Self-Seeded Two-Color X-Ray Free-Electron Lasers

A scheme for generating two simultaneous hard-x-ray free-electron laser pulses with a controllable difference in photon energy is described and then demonstrated using the self-seeding setup at the Linac Coherent Light Source (LCLS). The scheme takes advantage of the existing LCLS equipment, which allows two independent rotations of the self-seeding diamond crystal. The two degrees of freedom are used to select two nearby crystal reflections, causing two wavelengths to be present in the forward transmitted seeding x-ray pulse. The free-electron laser system must support amplification at both desired wavelengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New approaches for metabolomics by mass spectrometry

Small molecules constitute a large part of the world around us, including fossil and some renewable energy sources. Solar energy harvested by plants and bacteria is converted into energy rich small molecules on a massive scale. Some of the worst contaminants of the environment and compounds of interest for national security also fall in the category of small molecules. The development of large scale metabolomic analysis methods lags behind the state of the art established for genomics and proteomics. This is commonly attributed to the diversity of molecular classes included in a metabolome. Unlike nucleic acids and proteins, metabolites do not have standard building blocks, and, as a result, their molecular properties exhibit a wide spectrum. This impedes the development of dedicated separation and spectroscopic methods. Mass spectrometry (MS) is a strong contender in the quest for a quantitative analytical tool with extensive metabolite coverage. Although various MS-based techniques are emerging for metabolomics, many of these approaches include extensive sample preparation that make large scale studies resource intensive and slow. New ionization methods are redefining the range of analytical problems that can be solved using MS. This project developed new approaches for the direct analysis of small molecules in unprocessed samples, as well as pushed the limits of ultratrace analysis in volume limited complex samples. The projects resulted in techniques that enabled metabolomics investigations with enhanced molecular coverage, as well as the study of cellular response to stimuli on a single cell level. Effectively individual cells became reaction vessels, where we followed the response of a complex biological system to external perturbation. We established two new analytical platforms for the direct study of metabolic changes in cells and tissues following external perturbation. For this purpose we developed a novel technique, laser ablation electrospray ionization (LAESI), for metabolite profiling of functioning cells and tissues. The technique was based on microscopic sampling of biological specimens by mid-infrared laser ablation followed by electrospray ionization of the plume and MS analysis. The two main shortcomings of this technique had been limited specificity due to the lack of a separation step, and limited molecular coverage, especially for nonpolar chemical species. To improve specificity and the coverage of the metabolome, we implemented the LAESI ion source on a mass spectrometer with ion mobility separation (IMS). In this system, the gas phase ions produced by the LAESI source were first sorted according to their collisional cross sections in a mobility cell. These separated ion packets were then subjected to MS analysis. By combining the atmospheric pressure ionization with IMS, we improved the metabolite coverage. Further enhancement of the non-polar metabolite coverage resulted from the combination of laser ablation with vacuum UV irradiation of the ablation plume. Our results indicated that this new ionization modality provided improved detection for neutral and non-polar compounds. Based on rapid progress in photonics, we had introduced another novel ion source that utilized the interaction of a laser pulse with silicon nanopost arrays (NAPA). In these nanophotonic ion sources, the structural features were commensurate with the wavelength of the laser light. The enhanced interaction resulted in high ion yields. This ultrasensitive analytical platform enabled the MS analysis of single yeast cells. We extended these NAPA studies from yeast to other microorganisms, including green algae (Chlamydomonas reinhardtii) that captured energy from sunlight on a massive scale. Combining cellular perturbations, e.g., through environmental changes, with the newly developed single cell analysis methods enabled us to follow dynamic changes induced in the cells. In effect, we were able to use individual cells as a “laboratory,” and approached the long-standing goal of establishing a “lab-in-a-cell.” Model systems for these studies included cells of cyanobacteria (Anabaena), yeast (Saccharomyces cerevisiae), green algae (C. reinhardtii) and Arabidopsis thaliana.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Protein crystal structure from non-oriented, single-axis sparse X-ray data

X-ray free-electron lasers (XFELs) have inspired the development of serial femtosecond crystallography (SFX) as a method to solve the structure of proteins. SFX datasets are collected from a sequence of protein microcrystals injected across ultrashort X-ray pulses. The idea behind SFX is that diffraction from the intense, ultrashort X-ray pulses leaves the crystal before the crystal is obliterated by the effects of the X-ray pulse. The success of SFX at XFELs has catalyzed interest in analogous experiments at synchrotron-radiation (SR) sources, where data are collected from many small crystals and the ultrashort pulses are replaced by exposure times that are kept short enough to avoid significant crystal damage. The diffraction signal from each short exposure is so `sparse' in recorded photons that the process of recording the crystal intensity is itself a reconstruction problem. Using the EMC algorithm, a successful reconstruction is demonstrated here in a sparsity regime where there are no Bragg peaks that conventionally would serve to determine the orientation of the crystal in each exposure. In this proof-of-principle experiment, a hen egg-white lysozyme (HEWL) crystal rotating about a single axis was illuminated by an X-ray beam from an X-ray generator to simulate the diffraction patterns of microcrystals from synchrotron radiation. Millions of these sparse frames, typically containing only ~200 photons per frame, were recorded using a fast-framing detector. It is shown that reconstruction of three-dimensional diffraction intensity is possible using the EMC algorithm, even with these extremely sparse frames and without knowledge of the rotation angle. Further, the reconstructed intensity can be phased and refined to solve the protein structure using traditional crystallographic software. In conclusion, this suggests that synchrotron-based serial crystallography of micrometre-sized crystals can be practical with the aid of the EMC algorithm even in cases where the data are sparse.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the Short-Pulse X-ray Project at the Advanced Photon Source

The Advanced Photon Source Upgrade (APS-U) Project at Argonne will include generation of short-pulse x-rays based on Zholents deflecting cavity scheme. We have chosen superconducting (SC) cavities in order to have a continuous train of crabbed bunches and flexibility of operating modes. In collaboration with Jefferson Laboratory, we are prototyping and testing a number of single-cell deflecting cavities and associated auxiliary systems with promising initial results. In collaboration with Lawrence Berkeley National Laboratory, we are working to develop state-of-the-art timing, synchronization, and differential rf phase stability systems that are required for SPX. Collaboration with Advanced Computations Department at Stanford Linear Accelerator Center is looking into simulations of complex, multi-cavity geometries with lower- and higher-order modes waveguide dampers using ACE3P. This contribution provides the current R&D status of the SPX project.

43 PARTICLE ACCELERATORS↗

Sensitivity and Detection Limit of Spectroscopic-Grade Perovskite CsPbBr 3 Crystal for Hard X-Ray Detection

We report spectroscopic-grade single crystal detectors can register the energies of individual X-ray interactions enabling photon-counting systems with superior resolution over traditional photoconductive X-ray detection systems. Current technical challenges have limited the preparation of perovskite semiconductors for energy-discrimination X-ray photon-counting detection. Here, this work reports the deployment of a spectroscopic-grade CsPbBr 3 Schottky detector under reverse bias for continuum hard X-ray detection in both the photocurrent and spectroscopic schemes. High surface barriers of approximate to ≈ 1 eV are formed by depositing solid bismuth and gold contacts. The spectroscopic response under a hard X-ray source is assessed in resolving the characteristic X-ray peak. The methodology in enhancing X-ray sensitivity by controlling the X-ray energies and flux, and voltage, is described. The X-ray sensitivity varies between a few tens to over 8000 μC Gy air -1 cm -2 . The detectable dose rate of the CsPbBr 3 detectors is as low as 0.02 nGy air s -1 in the energy discrimination configuration. Finally, the unbiased CsPbBr 3 device forms a spontaneous contact potential difference of about 0.7 V enabling high quality of the CsPbBr 3 single crystals to operate in "passive" self-powered X-ray detection mode and the X-ray sensitivity is estimated as 14 μC Gy air -1 cm -2 . The great potential of spectroscopic-grade CsPbBr 3 devices for X-ray photon-counting systems is anticipated in this work.

36 MATERIALS SCIENCE↗

Generating Single-Spike Hard X-Ray Pulses with Nonlinear Bunch Compression in Free-Electron Lasers

Here, a simple method for generating single-spike hard x-ray pulses in free-electron lasers (FELs) has been developed at the Linac Coherent Light Source (LCLS). This is realized by nonlinear bunch compression using 20-pC bunch charge, demonstrated in the hard x-ray regime at 5.6 and 9 keV, respectively. Measurements show about half of the FEL shots containing a single-spike spectrum. At 5.6-keV photon energy, the single-spike shots have a mean pulse energy of about 10 μJ with 70% intensity fluctuation and the pulse full width at half maximum is evaluated to be at 200-as level.

47 OTHER INSTRUMENTATION↗

Epp: A C++ EGSnrc user code for x-ray imaging and scattering simulations

Purpose: Easy particle propagation (Epp) is a user code for the EGSnrc code package based on the C++ class library egspp. A main feature of egspp (and Epp) is the ability to use analytical objects to construct simulation geometries. The authors developed Epp to facilitate the simulation of x-ray imaging geometries, especially in the case of scatter studies. While direct use of egspp requires knowledge of C++, Epp requires no programming experience. Methods: Epp's features include calculation of dose deposited in a voxelized phantom and photon propagation to a user-defined imaging plane. Projection images of primary, single Rayleigh scattered, single Compton scattered, and multiple scattered photons may be generated. Epp input files can be nested, allowing for the construction of complex simulation geometries from more basic components. To demonstrate the imaging features of Epp, the authors simulate 38 keV x rays from a point source propagating through a water cylinder 12 cm in diameter, using both analytical and voxelized representations of the cylinder. The simulation generates projection images of primary and scattered photons at a user-defined imaging plane. The authors also simulate dose scoring in the voxelized version of the phantom in both Epp and DOSXYZnrc and examine the accuracy of Epp using the Kawrakow-Fippel test. Results: The results of the imaging simulations with Epp using voxelized and analytical descriptions of the water cylinder agree within 1%. The results of the Kawrakow-Fippel test suggest good agreement between Epp and DOSXYZnrc. Conclusions: Epp provides the user with useful features, including the ability to build complex geometries from simpler ones and the ability to generate images of scattered and primary photons. There is no inherent computational time saving arising from Epp, except for those arising from egspp's ability to use analytical representations of simulation geometries. Epp agrees with DOSXYZnrc in dose calculation, since they are both based on the well-validated standard EGSnrc radiation transport physics model.

60 APPLIED LIFE SCIENCES↗

A Multiwavelength Study of the Extreme AGN J2310-437

We present new X-ray, radio, and optical data for the unusual galaxy/cluster system J2310-437. Our results confirm the presence of an active nucleus and suggest an interpretation as an anomalous BL Lac object of bulk relativistic Doppler factor <2, with an optically deficient radio to X-ray spectrum. The radio, optical, and soft X-ray flux densities could lie along a single power-law function, lacking the curvature typical of BL Lac objects. Compared with other known sources that may have comparable multi-frequency spectra, J2310-437 is the most extreme. Its low isotropic optical/Ultraviolet (UV) radiation is consistent with the intensity of external photons governing the electron spectral break through Compton cooling; in this source the external photon density would be too low to produce a spectral break below the X-ray.

Worrall, D. M.↗

Comptonization of diffuse ambient radiation by a relativistic jet: The source of gamma rays from blazars?

Recent Energy Gamma Ray Experiment Telescope (EGRET) observations of blazars have revealed strong, variable gamma-ray fluxes with no signatures of gamma-ray absorption by pair production. This radiation probably originates from the inner parts of relativistic jets which are aimed nearly toward us. On sub-parsec scales, the jet will be pervaded by radiation from the broad-line region, as well as by photons from the central continuum source (some of which will be scattered by thermal plasma). In a frame moving with the relativistic outflow, the energy of this ambient radiation would be enhanced. This radiation would be Comptonized by both cold and relativistic electrons in the jet, yielding (in the observer's frame) a collimated beam of X-rays and gamma rays. On the assumption that this process dominates self-Comptonization of synchrotron radiation, we develop a self-consistent model for variable gamma-ray emission, involving a single population of relativistic electrons accelerated by a disturbance in the jet. The spectral break between the X-ray and gamma-ray band, observed in 3C 279 and deduced for other blazars, results from inefficient radiative cooling of lower energy electrons. The existence of such a break strongly favors a model involving Comptonization of an external radiation field over a synchrotron self-Compton model. We derive constraints on such model parameters as the location and speed of the source, its dimensions and internal physical parameters, the maximum photon energies produced in the source, and the density and distribution of ambient radiation. Finally, we discuss how observations might discriminate between our model and alternative ones invoking Comptonization of ambient radiation.

Sikora, Marek↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Streaked Sub-ps-resolution X-ray Line Shapes and Implications for Solid-density Plasma Dynamics

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

High-energy-density plasmas↗

Laboratory Studies of Astronomical Ices: Reaction Chemistry and Spectroscopy

In this article, we will describe the work of the Cosmic Ice Laboratory at NASA’s Goddard Space Flight Center to characterize the composition of and to understand the chemistry occurring in icy bodies in the Solar System and beyond. Our work has touched on a wide range of extraterrestrial environments including icy interstellar grains, small bodies such as comets and asteroids, and planets and moons. We are especially interested in the chemical and physical changes that occur in ices as a result of thermal changes or exposure to radiation. To this end, we conduct experiments designed to simulate cold extraterrestrial environments and measure physical properties of single- and multi-component ices. We expose ices to radiation (e.g., MeV protons or keV-MeV electrons) or high-energy photons (e.g., UV) to initiate physical and chemical changes. We conduct experiments using cryo-vacuum chambers equipped with analytical tools and radiation sources to make most of our measurements, including the collection of all spectroscopic data,in situ. When possible and appropriate, we also collect reaction products for further ex situ analysis. The work of the Cosmic Ice Lab provides critical data to astrochemists and others seeking to understand observations, make predictions, and plan future space missions.

Christopher K Materese↗