Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Dependence of Yb-169 absorbed dose energy correction factors on self-attenuation in source material and photon buildup in water

Purpose: Absorbed dose energy correction factors, used to convert the absorbed dose deposited in a LiF thermoluminescent dosimeter (TLD) into the clinically relevant absorbed dose to water, were obtained for both spherical volumetric sources and for the model 4140 HDR Yb-169 source. These correction factors have a strong energy dependence below 200 keV; therefore, spectral changes were quantified as Yb-169 photons traveled through both source material (Yb{sub 2}O{sub 3}) and water with the corresponding absorbed dose energy correction factors, f(r,{theta}), calculated as a function of location in a phantom. Methods: Using the MCNP5 Monte Carlo radiation transport simulation program, the Yb-169 spectrum emerging from spherical Yb{sub 2}O{sub 3} sources (density 6.9 g/cm{sup 3}) with radii between 0.2 and 0.9 mm were analyzed and their behavior compared against those for a point-source. The absorbed dose deposited to both LiF and H{sub 2}O materials was analyzed at phantom depths of 0.1-10 cm for each source radius and the absorbed dose energy correction factor calculated as the ratio of the absorbed dose to water to that of LiF. Absorbed dose energy correction factors for the Model 4140 Yb-169 HDR brachytherapy source similarly were obtained and compared against those calculated for the Model M-19 Ir-192 HDR source. Results: The Yb-169 average spectral energy, emerging from Yb{sub 2}O{sub 3} spherical sources 0.2-0.9 mm in radius, was observed to harden from 7% to 29%; as these photons traveled through the water phantom, the photon average energy softened by as much as 28% at a depth of 10 cm. Spectral softening was dependent on the measurement depth in the phantom. Energy correction factors were found to vary both as a function of source radius and phantom depth by as much as 10% for spherical Yb{sub 2}O{sub 3} sources. The Model 4140 Yb-169 energy correction factors depended on both phantom depth and reference angle and were found to vary by more than 10% between depths of 1 and 10 cm and angles of 0 deg. and 180 deg. This was in contrast to that of the Model M-19 Ir-192 source which exhibited approximately 3.5%-4.4% variation in its energy correction factors from phantom depths of 0.5-10 cm. The absorbed dose energy correction factor for the Ir-192 source, on the other hand, was independent of angle to within 1%. Conclusions: The application of a single energy correction factor for Yb-169 TLD based dosimetry would introduce a high degree of measurement uncertainty that may not be reasonable for the clinical characterization of a brachytherapy source; rather, an absorbed dose energy correction function will need to be developed for these sources. This correction function should be specific to each source model, type of TLD used, and to the experimental setup to obtain accurate and precise dosimetric measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Proteomics Analysis of Human Contaminant Proteins

Complete characterization of unknowns via proteomics remains challenging. There exist regions of mass spectrometry-based proteomics data where empirical measurements are not attributed to peptides, and/or sequenced peptides from mass spectra are not attributed to any source. These uncharacterized regions are known as the “dark” proteome. Many proteomics tools rely on some a priori knowledge of sample composition; few tools allow for investigation of unknowns without relying on composition assumptions. Further, the potential low abundance of minor traces in these uncharacterized regions can make elucidation of the “dark” proteome challenging. Herein, we describe the development and evaluation of approaches to study the “dark” proteome and move towards an untargeted approach for more complete characterization, namely by studying minor human protein traces in non-human samples and combining that approach with non-human source organism identification without relying on assumptions. Human protein markers, in the form of genetically variant peptides, have been extensively examined in a variety of human matrices, including blood, plasma, and hair, but have yet to be investigated in non-human samples, such as cell cultures, as human contaminant traces. Genetically variant peptides are those that are found in proteins carrying single nucleotide polymorphisms. In this work, we aimed to (1) investigate the feasibility of detecting human contaminant genetically variant peptides (GVPs) in a diverse set of non-human organisms using public proteomics data and a computational pipeline, as well as to (2) develop a combined capability for untargeted source organism characterization and GVP detection. To our knowledge, this is the first report of applying these approaches towards a more complete proteomic characterization of unknowns. We successfully demonstrate the feasibility of broad human contaminant GVP detection in proteomics data, develop a better understanding of GVP detectability, characterize the sample-to-sample variability in GVP detection, and identify a core set of GVPs that can potentially be used as markers indicative of the human contaminant traces portion of the “dark” proteome. Further, we developed and evaluated a combined pipeline, MARLOWE-GVP, that enables both untargeted source organism characterization and GVP detection. We show high accuracy of correct source organism characterization and high degree of similarity of human contaminant GVP detection compared to the conventional approach. Success on both these efforts have allowed us to advance our understanding and characterization of the “dark” proteome.

59 BASIC BIOLOGICAL SCIENCES↗

Corrosion and Chemical Characterization of Bio-Oils from Biomass with Varying Ash and Moisture Contents

As part of the Feedstock Conversion Interface Consortium four samples of pine chips (all combinations of low and high moisture and ash content) were collected and processed for fast pyrolysis. The prepared biomass samples were liquefied at the National Renewable Energy Laboratory (NREL) using the fast pyrolysis process. Following some characterization of the bio-oils at NREL, the bio-oils were shipped to Oak Ridge National Laboratory (ORNL) for corrosion testing and further characterization.The content and composition of ash in each bio-oil was determined. Corrosion testing consisted of exposing selected metallic and elastomer samples for 1000 hr at 50°C and for longer times at room temperature as well as electrochemical impedance spectroscopy measurements to assess relative corrosivity of the bio-oils. Chemical characterization was conducted to identify the corrosive component of the bio-oils as well as to define the chemical differences among the oils. It was hypothesized that there could be a catalytic effect from the higher ash content in two of the biomass sources. Results of these characterization and corrosion studies will be reported.

Keiser, Jim↗

Extraction of high value added gelatin biopolymer from black tilapia (Oreochromis mossambicus) head bones

Black tilapia (Oreochromis mossambicus) fish head bones were evaluated for its possibilities in extracting gelatin. Head bones were subjected to pre-treatment with 3% of hydrochloric acid (HCl) for demineralization before undergoes thermal extraction process. The raw head bones were characterized via Scanning Electron Microscopy (SEM) in order to investigate the external and internal surface morphology. SEM images also reveal the presence of collagen fiber with 1 µm diameter in the head bone. The black tilapia fish head bones yields 5.75 % of gelatin in wet weight basis, indicating the possibility of this fish species as sources of gelatin. Further characterizations were done on both raw head bones and extracted gelatin through Fourier Transform Infrared Spectroscopy (FTIR) and proximate analysis. The head bones gelatin shows high protein (10.55%) and ash (3.11 %) content with low moisture. This further proves the effectiveness of demineralization and extraction method used. The black tilapia fish head bones are found to be a prospective source of gelatin with good chemical and functional properties.

60 APPLIED LIFE SCIENCES↗

Bright Photon Pair Source with High Spectral and Spatial Purity

Spontaneous parametric down-conversion (SPDC) is a reliable and robust source of photons for quantum information applications. For applications that involve operations such as entanglement swapping or single-photon heralding, two-photon states are required to be factorable (uncorrelated) in their spectral and spatial degrees of freedom. We report the design and experimental characterization of an SPDC source that has been optimized for high spectral and spatial purity. The source is pumped by the 776 nm output of a mode-locked Ti:Sapphire laser and consists of a periodically-poled Potassium Titanyl Phosphate (PPKTP) crystal phase-matched for collinear type-II SPDC. The dispersive properties of PPKTP at these wavelengths is such that it is possible to minimize the spectral entanglement by matching the widths of the pump to the spectral phase-matching function. The spatial entanglement is minimized through careful control of the pump focus, yielding nearly single-mode emission. An advantage of this approach is that the emission rate into the collection modes is very high, resulting in a very bright SPDC source. We also report a scheme that employs the output of collinear sources such as these to produce polarization-entangled photon pairs. The scheme, which requires only simple polarization elements, can be scaled to N-photon GHZ states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian Inversion of Seismic and Electromagnetic Data for Marine Gas Reservoir Characterization Using Multi-chain Markov Chain Monte Carlo Sampling

In this study we developed an efficient Bayesian inversion framework for interpreting marine seismic amplitude versus angle (AVA) and controlled source electromagnetic (CSEM) data for marine reservoir characterization. The framework uses a multi-chain Markov-chain Monte Carlo (MCMC) sampler, which is a hybrid of DiffeRential Evolution Adaptive Metropolis (DREAM) and Adaptive Metropolis (AM) samplers. The inversion framework is tested by estimating reservoir-fluid saturations and porosity based on marine seismic and CSEM data. The multi-chain MCMC is scalable in terms of the number of chains, and is useful for computationally demanding Bayesian model calibration in scientific and engineering problems. As a demonstration, the approach is used to efficiently and accurately estimate the porosity and saturations in a representative layered synthetic reservoir. The results indicate that the seismic AVA and CSEM joint inversion provides better estimation of reservoir saturations than the seismic AVA-only inversion, especially for the parameters in deep layers. The performance of the inversion approach for various levels of noise in observational data was evaluated – reasonable estimates can be obtained with noise levels up to 25%. Sampling efficiency due to the use of multiple chains was also checked and was found to have almost linear scalability.

Ren, Huiying↗

The Effect of Spectral Resolution of Light Sources on Photopic and a-opic Quantities

There is a growing interest in including light source spectrum in advanced lighting software tools and simulations. Given that traditional lighting software tools have been used primarily for calculating photometric quantities, their simplifying assumptions may not be suitable for calculating other a-opic quantities. Commonly used simulation tools use three values to represent the three primary colors (red, green, and blue), but others have expanded the number of bands (i.e., the spectral resolution) to 9, 27, or 81 in an attempt to more accurately represent variations in light source spectrum and downstream spectrally-derived quantities. It remains unclear, however, to what extent spectral resolution affects calculated quantities. To address this gap, a numerical analysis was completed using a large spectral power distribution database (n = 1,302 light sources). Calculated illuminance, a-opic irradiance, luminous efficacy of radiation (LER), melanopic efficacy of radiation (MER), and melanopic to photopic (M/P) ratio were compared for spectral resolutions of 3 and 9 bands compared to a baseline of 81 bands. Across all examined lighting quantities, considerable errors—a mean absolute percent error of 18.4%—were found when using 3 band calculations. These were reduced to 4% for 9 band calculations. The errors varied by metric and light source type. The results suggest that the use of 9 bands can more accurately characterize performance of different light source types across a range of metrics compared to using 3 bands.

Abboushi, Belal K.↗

GAMMA-RAY EMISSION FROM PSR J0007+7303 USING SEVEN YEARS OF FERMI LARGE AREA TELESCOPE OBSERVATIONS

Based on more than seven years of Fermi Large Area Telescope Pass 8 data, we report on a detailed analysis of the bright gamma-ray pulsar (PSR) J0007+7303. We confirm that PSR J0007+7303 is significantly detected as a point source also during the off-peak phases with a test statistic value of 262 (∼16 σ ). In the description of the off-peak spectrum of PSR J0007+7303, a power law with an exponential cutoff at 2.7 ± 1.2 ± 1.3 GeV (the first/second uncertainties correspond to statistical/systematic errors) is preferred over a single power law at a level of 3.5 σ . The possible existence of a cutoff hints at a magnetospheric origin of the emission. In addition, no extended gamma-ray emission is detected that is compatible with either the supernova remnant (CTA 1) or the very high-energy (>100 GeV) pulsar wind nebula. A flux upper limit of 6.5 × 10{sup −12} erg cm{sup −2} s{sup −1} in the energy range 10–300 GeV is reported, for an extended source assuming the morphology of the VERITAS detection. During on-peak phases, a sub-exponential cutoff is significantly preferred (∼11 σ ) for representing the spectral energy distribution, in both the phase-averaged and phase-resolved spectra. Three glitches are detected during the observation period and we found no flux variability at the time of the glitches or in the long-term behavior. We also report the discovery of a previously unknown gamma-ray source in the vicinity of PSR J0007+7303, Fermi J0020+7328, which we associate with the z = 1.781 quasar S5 0016+73. A concurrent analysis of this source is needed to correctly characterize the behavior of CTA 1 and it is also presented in the paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Challenges and Opportunities with Highly Brilliant X-ray Sources for multi-Modal in-Situ and Operando Characterization of Solar Cells

The generation of electricity is one of the great challenges of our time, and its success shall be measured by the sustainability from ecological, economical, and social points of view. The advent of photovoltaics has led to a dramatic decrease of the levelized cost of energy (LCOE) such that it has not only reached grid parity in many countries but is often the most competitive energy source.

Stuckelberger, M. E.↗

Learning to Apply Metrology Principles to the Measurement of X-ray Intensities in the 500 eV to 110 keV Energy Range

National Security Technologies, LLC (NSTec), Livermore Operations, has two optical radiation calibration laboratories accredited by “the National Voluntary Laboratories Accreditation Program (NVLAP) which is the accrediting body of” the National Institute of Standards and Technology (NIST), and is now working towards accreditation for its X-ray laboratories. NSTec operates several laboratories with X-ray sources that generate X-rays in the energy range from 50 eV to 115 keV. These X-ray sources are used to characterize and calibrate diagnostics and diagnostic components used by the various national laboratories, particularly for plasma analysis on the Lawrence Livermore National Laboratory (LLNL) National Ignition Facility (NIF). Because X-ray photon flux measurement methods that can be accredited, i.e., traceable to NIST, have not been developed for sources operating in these energy ranges, NSTec, NIST, and the National Voluntary Accreditation Program (NVLAP) together have defined a path toward the development and validation of accredited metrology methods for X-ray energies. The methodology developed for the high energy X-ray (HEX) Laboratory was NSTec’s starting point for X-ray metrology accreditation and will be the basis for the accredited processes in the other X-ray laboratories. This paper will serve as a teaching tool, by way of this example using the NSTec X-ray sources, for the process and methods used in developing an accredited traceable metrology.

07 ISOTOPE AND RADIATION SOURCES↗

CeSOX: Short-Distance Neutrino Oscillations with BoreXino

Several experimental anomalies in neutrino physics may point to the possible existence of one or more additional neutrino species that do not interact weakly, the so-called sterile neutrinos. The third phase of the Borexino experiment (SOX) is devoted to verification of this hypothesis. Within the first stage (CeSOX) the count rate of antineutrino events in the liquid scintillation detector from the artificial source {sup 1}44Ce–{sup 1}44Pr placed in the special pit beneath the setup will be measured. The smaller antineutrino flux, as compared to the original one, would indicate the presence of oscillations into sterile states. This paper gives a survey of the CeSOX experiment, including the general description, the characterization of the radioactive source and the specific features of its use, the description of the method for data analysis, and the expected results. Depending on the significance of the obtained scientific information, the decision on carrying out the second stage of the SOX experiment with the {sup 51}Cr source of electron neutrinos will be made.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements and simulations of focused beam for orthovoltage therapy

Purpose: Megavoltage photon beams are typically used for therapy because of their skin-sparing effect. However, a focused low-energy x-ray beam would also be skin sparing, and would have a higher dose concentration at the focal spot. Such a beam can be produced with polycapillary optics. MCNP5 was used to model dose profiles for a scanned focused beam, using measured beam parameters. The potential of low energy focused x-ray beams for radiation therapy was assessed. Methods: A polycapillary optic was used to focus the x-ray beam from a tungsten source. The optic was characterized and measurements were performed at 50 kV. PMMA blocks of varying thicknesses were placed between optic and the focal spot to observe any variation in the focusing of the beam after passing through the tissue-equivalent material. The measured energy spectrum was used to model the focused beam in MCNP5. A source card (SDEF) in MCNP5 was used to simulate the converging x-ray beam. Dose calculations were performed inside a breast tissue phantom. Results: The measured focal spot size for the polycapillary optic was 0.2 mm with a depth of field of 5 mm. The measured focal spot remained unchanged through 40 mm of phantom thickness. The calculated depth dose curve inside the breast tissue showed a dose peak several centimeters below the skin with a sharp dose fall off around the focus. The percent dose falls below 10% within 5 mm of the focus. It was shown that rotating the optic during scanning would preserve the skin-sparing effect of the focused beam. Conclusions: Low energy focused x-ray beams could be used to irradiate tumors inside soft tissue within 5 cm of the surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric accuracy of a deterministic radiation transport based {sup 192}Ir brachytherapy treatment planning system. Part I: Single sources and bounded homogeneous geometries

Purpose: The aim of this work is to validate a deterministic radiation transport based treatment planning system (TPS) for single {sup 192}Ir brachytherapy source dosimetry in homogeneous water geometries. Methods: TPS results were obtained using the deterministic radiation transport option of a BRACHYVISION v. 8.8 system for three characteristic source designs (VS2000, GMPlus HDR, and GMPlus PDR) with each source either centered in a 15 cm radius spherical water phantom, or positioned at varying distance away from the phantom center. Corresponding MC simulations were performed using the MCNPX code v.2.5.0 and source geometry models prepared using information provided by the manufacturers. Results: Comparison in terms of the AAPM TG-43 dosimetric formalism quantities, as well as dose rate distributions per unit air kerma strength with a spatial resolution of 0.1 cm, yielded close agreement between TPS and MC results for the sources centered in the phantom. Besides some regions close to the source longitudinal axes where discrepancies could be characterized as systematic, overall agreement for all three sources studied is comparable to the statistical (type A) uncertainty of MC simulations (1% at the majority of points in the geometry increasing to 2%-3% at points lying both away from the source center and close to the source longitudinal axis). A corresponding good agreement was also found between TPS and MC results for the sources positioned away from the phantom center. Conclusions: Results of this work attest the capability of the TPS to accurately account for the scatter conditions regardless of the size or shape of a given geometry of dosimetric interest, and the position of a source within it. This is important since, as shown in the literature and summarized also in this work, these factors could introduce a significant dosimetric effect that is currently ignored in clinical treatment planning. It is concluded that the implementation of the deterministic radiation transport option of the BRACHYVISION v. 8.8 system for {sup 192}Ir brachytherapy dosimetry in homogeneous water geometries yields results of comparable accuracy to the golden standard of Monte Carlo simulation, in clinically viable calculation times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The impact of flow focusing on gas hydrate accumulations in overpressured marine sediments

This study demonstrates the potential for flow focusing due to overpressuring in marine sedimentary environments to act as a significant methane transport mechanism from which methane hydrate can precipitate in large quantities in dipping sandstone bodies. Traditionally, gas hydrate accumulations in nature are discussed as resulting from either short-range diffusive methane migration or from long-range advective fluid transport sourced from depth. However, 3D simulations performed in this study demonstrate that a third migration mechanism, short-range advective transport, can provide a significant methane source that is unencumbered by limitations of the other two end-member mechanisms. Short-range advective sourcing is advantageous over diffusion because it can convey greater amounts of methane to sands over shorter timespans, yet it is not necessarily limited by down-dip pore blocking in sands as is typical of updip advection from a deep source. These results are novel because they integrate pore size impacts on spatial solubility gradients, grid block properties that evolve through time, and methane sourcing through microbial methanogenesis into a holistic characterization of environments exposed to multiple methane hydrate sourcing mechanisms. We show that flow focusing toward sand bodies transports large quantities of methane, the magnitude of which are determined by the sand-clay solubility contrast, and generates larger quantities of hydrate in sands than a solely diffusive system; after depositing methane as hydrate, fluid exiting a sand body is depleted in methane and leaves a hydrate free region in its wake above the sand. Additionally, we demonstrate that in overpressured environments, hydrate growth is initially diffusively dominated before transitioning to an advection-dominated regime. The timescale and depth at which this transition takes place depends primarily on the rate of microbial metabolism and the sedimentation rate but only depends loosely on the degree of overpressuring.

Nole, Michael↗

Cf-252 Characterization Documents

Six documents were written by Vance and Associates under contract to the Off-Site Source Recovery Project of Los Alamos National Laboratory. These Six documents provided the basis for characterization of Californium-252 sealed sources and for the packaging and manifesting of this material for disposal at the Waste Isolation Pilot Project. The Six documents are: 1. VA-OSR-10, Development of radionuclide distributions for Cf-252 sealed sources. 2. VA-OSR-11, Uncertainty analysis for Cf-252 sealed sources. 3. VA-OSR-12, To determine the radionuclides in the waste drums containing Cf-252 sealed source waste that are required to be reported under the requirements of the WIPP WAC and the TRAMPAC. 4. VA-OSR-13, Development of the spreadsheet for the radiological calculations for the characterization of Cf-252 sources. 5. VA-OSR-14, Relative importance of neutron-induced fission in Cf-252 sources. 6. VA-OSR-15, Determine upper bound of decay product inventories from a drum of Cf-252 sources. These six documents provide the technical basis for the characterization of Cf-252 sources and will be part of the AK documentation required for submittal to the Central Characterization Project (CCP) of WIPP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRACER-BC2-SP2 Field Campaign Report

The focus of this project was to assess black carbon and brown carbon aerosol in Houston, Texas during the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility Tracking Aerosol Convection Interactions Experiment (TRACER) through the co-located deployment of a single-particle soot photometer (SP2) with the University of Houston/Baylor aerosol optical instrumentation in the Texas (BC)2 network in and around Houston. The deployment of the SP2 enables us to expand the spatial assessment of black carbon (BC) in Houston during TRACER by permitting a more thorough characterization of BC, including sources, transport, and potential processing. BC is well known to undergo physical and chemical changes during local and long-range transport that will impact its optical properties. By deploying multiple SP2s in the Houston area, the impacts of local and long-range transport can be assessed. The TRACER-BC2-SP2 campaign will expand spatial and temporal characterization of BC in the Houston area during TRACER and link the TRACER-carbon analysis to ongoing black and brown carbon monitoring (Texas [BC]2 network) in Houston.

54 ENVIRONMENTAL SCIENCES↗

Work Plan for the Site-wide SSHAC Level 3 Probabilistic Seismic Hazard Analysis at INL

This work plan provides the overall framework, key activities, key tasks, and schedule for the execution of a probabilistic seismic hazard analysis at Idaho National Laboratory (INL). The probabilistic seismic hazard analysis will follow processes and procedures appropriate for the Senior Seismic Hazard Analysis Committee (SSHAC) Level 3 study provided in U. S. Nuclear Regulatory Commission guidance, NUREG-2213. The SSHAC Level 3 probabilistic seismic hazard analysis (PSHA) is being conducted as an INL site-wide effort. The work plan was developed and revised by participants who will perform the SSHAC Level 3 PSHA. The work plan also includes the quality assurance requirements commensurate with American Society of Mechanical Engineers Nuclear Quality Assurance NQA 1 2008/2009 and 2011 Addendum for design nuclear facilities under the U.S. Department of Energy and U. S. Nuclear Regulatory Commission. The scope of the SSHAC Level 3 PSHA is designed to produce the mean-centered definition of the seismic hazard with the appropriate treatment of uncertainties supported by the associated technical justifications. The SSHAC Level 3 study will properly implement and completely document the activities of evaluation, integration, and documentation. The evaluation process will consider data, models, and methods proposed by the larger technical community that are relevant to the PSHA at INL. The integration process will build seismic-source and ground-motion characterization models that represent the center, body, and range of technically defensible interpretations, taking into consideration the outcomes of the evaluation process. Key tasks and activities—such as a project kickoff meeting, three workshops, four formal working meetings, and a briefing meeting with the Participatory Peer Review Panel—will occur for the seven-member technical integration teams to construct seismic-source and ground-motion-characterization models. Both preliminary and final hazard-input documents will be developed to perform sensitivity analyses and the final PSHA, respectively. The entire study will be thoroughly documented in draft and final reports. The Participatory Peer Review Panel will review the SSHAC Level 3 study from start to finish, including the draft and final INL Site-wide PSHA reports, so they can provide a closure letter documenting the study’s adherence to SSHAC processes and technical adequacy of the final products.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗