Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Effectiveness of Surface Treatment Techniques for Composite Bonding with Different Contamination Levels

Various surface treatment techniques have been developed to promote adhesive bond performance for composite structural components in aerospace applications. The condition of the pre-bond surface is critical to achieving desirable bond quality. Contamination on bonding surfaces is well recognized as a major threat to ultimate bond performance. Variation in contamination level has brought additional challenges into manufacturing process control. High fidelity surface treatment techniques are required for effective removal of contaminants over a wide range of contamination levels. In this study, a common contaminant, i.e. silicone mold release, was introduced to pre-bond composite surfaces with different concentrations. Plasma and laser surface treatment techniques were performed and their effectiveness in restoring and enhancing desirable bond quality was investigated. Surface characterization techniques, including water contact angle goniometry, Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy, were conducted to assess the condition of contaminated surfaces and the improvement induced by plasma and laser surface treatments. Failure modes from a customized double cantilever beam test were investigated before and after surface treatments. Fundamental mechanisms of plasma and laser surface treatments on the composite bonding surfaces were also investigated.

Fang, Xiaomei↗

Characterization of Archaeal Community in Contaminated and Uncontaminated Surface Stream Sediments

Abstract Archaeal communities from mercury and uranium-contaminated freshwater stream sediments were characterized and compared to archaeal communities present in an uncontaminated stream located in the vicinity of Oak Ridge, TN, USA. The distribution of the Archaea was determined by pyrosequencing analysis of the V4 region of 16S rRNA amplified from 12 streambed surface sediments. Crenarchaeota comprised 76% of the 1,670 archaeal sequences and the remaining 24% were from Euryarchaeota. Phylogenetic analysis further classified the Crenarchaeota as a Freshwater Group, Miscellaneous Crenarchaeota group, Group I3, Rice Cluster VI and IV, Marine Group I and Marine Benthic Group B; and the Euryarchaeota into Methanomicrobiales, Methanosarcinales, Methanobacteriales, Rice Cluster III, Marine Benthic Group D, Deep Sea Hydrothermal Vent Euryarchaeota 1 and Eury 5. All groups were previously described. Both hydrogen- and acetate-dependent methanogens were found in all samples. Most of the groups (with 60% of the sequences) described in this study were not similar to any cultivated isolates, making it difficult to discern their function in the freshwater microbial community. A significant decrease in the number of sequences, as well as in the diversity of archaeal communities was found in the contaminated sites. The Marine Group I, including the ammonia oxidizer Nitrosopumilus maritimus, was the dominant group in both mercury and uranium/nitrate-contaminated sites. The uranium-contaminated site also contained a high concentration of nitrate, thus Marine Group I may play a role in nitrogen cycle.

08 HYDROGEN↗

Thermocapillary flows and their stability: Effects of surface layers and contamination

The fluid mechanics and heat transfer of motions driven by surface tension gradients (Marangoni convection) were analyzed theoretically to obtain an understanding of the convection accompanying the process of growing high quality single crystals from the melt in a mu-g environment. The geometries considered include two dimensional liquid filled slots and axisymmetric float zone configurations.

Davis, S. H.↗

Effects of the contamination environment on surfaces and materials

In addition to the issues that have always existed, demands are being placed on space systems for increased contamination prevention/control. Optical surveillance sensors are required to detect low radiance targets. This increases the need for very low scatter surfaces in the optical system. Particulate contamination levels typically experienced in today's working environments/habits will most likely compromise these sensors. Contamination (molecular and particulate) can also affect the survivability of space sensors in both the natural and hostile space environments. The effects of di-octyl phthalate (DOP) on sensors are discussed.

Maag, Carl R.↗

Laboratory studies on surface sampling of Bacillus anthracis contamination: summary, gaps, and recommendations

This article summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the 1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and 2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed. Recommendations are given for future evaluations of data from existing studies and possible new studies.

anthrax↗

Correlation of an optical system degradation with contamination on a critical surface

The loss of sensitivity of a radiantly cooled radiometer during space operation was investigated. A quartz crystal microbalance (QCM), mounted in the proximity of the instrument filter lens and held at its temperature, measured the contaminant at the location during a vacuum test. The temperature cycling of the lens and the QCM verified the contamination of the lens as the cause of the deterioration. Data on the instrument performance in space and in the chamber allowed estimation of the rate of contaminant accretion on the lens in space service. That rate was used to estimate the contaminant partial pressure. The nature of material was inferred by comparison of the partial pressures and the saturated vapor pressures of materials at the temperature of the contaminated surface. These data, in conjunction with data on fields of view of the lens, are used to identify the sources of contamination.

Scialdone, J. J.↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, a LIBS system was designed and assembled at NASA Langley Research Center (LaRC) to enable detection of ultralow concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization of CFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is also presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity.

Surface characterization, Carbon fiber reinforced ↗

Recent Advances in LIBS for Real-Time Detection of Silicone Contaminants on CFRP Surfaces

Laser induced breakdown spectroscopy (LIBS) is a materials characterization technique that has been advanced and refined to provide in situ, real-time quality control of carbon fiber reinforced polymer (CFRP) surfaces. As part of an effort to improve process control for adhesive bonding, aLIBS system was designed and assembled at the NASA Langley Research Center (LaRC) to enable detection of ultra low concentrations of silicone contamination on CFRP adherends. The LIBS instrument provides high sensitivity detection and quasi-nondestructive surface characterization ofCFRP adherends prior to adhesive bonding. This review focuses on the advancements at LaRC using LIBS as a quality control tool for the detection of silicone contaminants for improved adhesive bonding reliability of CFRP materials. This work describes how the LIBS technique was advanced by analyzing the laser parameters, studying the laser-matter interactions, and performing time-resolved measurements to determine the optimal plasma conditions for elemental detection. In addition, LIBS results were compared to X-ray photoelectron spectroscopy data to enable quantitative analysis from analytical calibration curves. Examples are shown of how to perform surface mapping of silicone contamination. Finally, a brief discussion is presented on LIBS instrumentation, recommendations for laser parameters and instrumentation components, and LIBS technique maturity

Rodolfo I. Ledesma↗

Changes in the Optical Properties of Materials Are Observed After 18 Months in Low Earth Orbit

Materials located on the exterior of spacecraft in low Earth orbit are subjected to a number of environmental threats, including atomic oxygen, ultraviolet radiation, thermal cycling, and micrometeroid and debris impact. Atomic oxygen attacks materials vulnerable to oxidation. Ultraviolet radiation can break chemical bonds and cause undesirable changes in optical properties. Thermal cycling can cause cracking, and micrometeroid and debris impacts can damage protective coatings. Another threat is contamination. The outgassing of volatile chemicals can contaminate nearby surfaces, changing their thermal control properties. Contaminated surfaces may undergo further change as a result of atomic oxygen and ultraviolet radiation exposure. The Passive Optical Sample Assembly (POSA) experiment was designed as a risk mitigation experiment for the International Space Station. Samples were characterized before launch, exposed for 18 months on the exterior of Mir, and characterized upon their return. Lessons learned from POSA about the durability of material properties can be applied to the space station and other long-duration missions.

Jaworske, Donald A.↗

Novel alkali intercalated and acid-exfoliated biochars with enhanced surface areas for contaminant adsorption applications

Cost-effective and eco-friendly adsorbents are essential in environmental engineering and biochar is a promising material from the perspective. A novel and efficient surface modification approach involving alkali intercalation and acid exfoliation was designed in this study to enhance the physicochemical properties of biochar. Here, the alkali intercalation process utilizes potassium hydroxide (KOH), while acid exfoliation involves varying HNO 3 , H 2 SO 4 , and H 3 PO 4 concentrations. A simple two-stage pyrolysis process was employed to facilitate the intercalation-exfoliation modification. The modified biochars were characterized using BET, SEM, XRD, etc., to understand physicochemical properties. To quantify the effectiveness of the modifications, adsorption of malachite green dye as a model moiety was investigated. Dye removal sorption rates exceeding 99 % were recorded in the case of the biochars modified through a two-step process using KOH and 0.1MH 3 PO 4 . Specifically, the highest contaminant removal of 99.9 % was recorded when 60 mg of the KOH-0.1MH 3 PO 4 biochar was employed, which is significantly higher than unmodified biochar’s 45.41 % removal at a higher dosage of 100 mg. Moreover, the adsorption kinetics revealed that all the modified biochars attained the maximum removal concentrations (~99 % removal) in a mere 300 min, indicating a tenfold improvement in adsorption rate from unmodified biochar's requirement of over 5000 min. The results achieved through this study provide a cost-effective, fast, and environment-friendly technology for enhancing the adsorption characteristics and performance of biochars toward contaminant removal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing Landing Site Contamination Using 3-D Trajectory Optimization for Surface Hoppers

Rocket-powered vehicles utilizing Vertical Take-off Vertical Landing (VTVL) are a compelling alternative to surface rovers for exploring planetary and lunar bodies. These so called “hoppers” provide enhanced mobility for accessing locations difficult to reach, and over a wider region of the surface. However, contamination and plume interactions from rocket exhaust deposited at landing sites is anticipated since landing approaches are typically along a vertical direction during the final descent. Consequently, exhaust products may alter the surface chemistry, potentially confounding compositional analysis for samples collected in the vicinity of the landing site or jeopardize mining efforts. There has been no rigorous study on flight maneuvers that can mitigate plume-to-surface interactions. A multi-objective optimization tool has been developed to simulate propulsive hops on a planetary body and minimize both fuel consumption and site alterations. Trajectories are derived by multi-objective optimization and include solutions with significant reduction in contamination for a modest increase in fuel consumption. For these solutions, surface-to-surface propulsive transfer is demonstrated, but the method can also be modified for orbit-to-surface transfers (e.g., landers).

guidance↗

Reducing Landing Site Contamination Using 3-D Trajectory Optimization for Surface Hoppers

Rocket-powered vehicles utilizing Vertical Take-off Vertical Landing (VTVL) are a compelling alternative to surface rovers for exploring planetary and lunar bodies. These so called “hoppers” provide enhanced mobility for accessing locations difficult to reach, and over a wider region of the surface. However, contamination and plume interactions from rocket exhaust deposited at landing sites is anticipated since landing approaches are typically along a vertical direction during the final descent. Consequently, exhaust products may alter the surface chemistry, potentially confounding compositional analysis for samples collected in the vicinity of the landing site or jeopardize mining efforts. There has been no rigorous study on flight maneuvers that can mitigate plume-to-surface interactions. A multi-objective optimization tool has been developed to simulate propulsive hops on a planetary body and minimize both fuel consumption and site alterations. Trajectories are derived by multi-objective optimization and include solutions with significant reduction in contamination for a modest in-crease in fuel consumption. For these solutions, surface-to-surface propulsive transfer is demonstrated, but the method can also be modified for orbit-to-surface transfers (e.g., landers).

guidance↗

Wipe-rinse technique for quantitating microbial contamination on large surfaces

The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).

Kirschner, L. E.↗

Methodology for Volume Reduction of Radioactive Metallic Waste - 19491

A decontamination methodology for out-of-core nuclear reactor alloys is being developed to reduce the volume of low- and intermediate-level radioactive metallic wastes. For out-of-core reactor metals contamination is limited to surface oxides. For surface oxide removal a technology based on laser ablation is being explored. This paper presents work performed to identify the key parameters that affect the efficiency of removal of surface oxides from out-of-core reactor metals and alloys. This study examined carbon steel (used for coolant feeder pipes of CANDU{sup R} reactors) as a model reactor material. The morphology and thickness of oxides on a used feeder pipe vary considerably depending on its service life and the location along the pipe. Hence, oxides with different morphologies and thicknesses were first grown by corroding carbon steel coupons under different solution conditions. The oxides formed ranged from thin layers of uniformly distributed mixed Fe{sup II}/Fe{sup III} hydroxides/oxides to dual layers consisting of ferric oxide/oxyhydroxide islands with thickness up to 200 μm on top of the more uniformly distributed mixed Fe{sup II}/Fe{sup III} layer. Removal of these oxides was performed using a 1064 nm pulsed laser. Of the laser parameters tested, the pulse radiance was found to be the most important. Four radiances ranging from 5 to 200 MW/cm{sup 2} were used. At radiances higher than 100 MW/cm{sup 2}, single pulses were sufficient to remove both types of oxides, but also extensively melted the metal substrate. At lower radiances, multiple pulses were required to remove the oxides completely, but caused less damage to the metal substrate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contamination of Optical Surfaces Under Irradiation by Outgassed Volatile Products

Deposition of outgassed products of a polymeric composite on model material surfaces being irradiated by electrons and protons with initial energies of E{sub e} = 40 keV and E{sub p} = 30 keV respectively was studied. It was shown that deposition of volatile products on model material surfaces being under ionizing radiations results in increase of organic film growth rate.

36 MATERIALS SCIENCE↗

Contamination Characteristics of Concrete by Radio-Cs in Off-site Concrete - 18284

To obtain the penetration information of radio-cesium (r-Cs) in concrete, useful for the decommissioning or decontamination of contaminated concrete structures, Cs distributions are evaluated for real contaminated concrete near the Fukushima Daiichi nuclear power plant. The results showed that, for many road-related concrete samples, the contamination was limited to the surface. In other cases, the surface was contaminated and contamination at depths of a few millimeters was observed. The contamination on the surface was not water soluble; therefore, it was easy to reduce contamination using a water jet. Where cracks were observed in the concrete, r-Cs penetrated at least 10 cm deep. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovative Use of Cr(VI) Plume Depictions and Pump-and-Treat Capture Analysis to Estimate Risks of Contaminant Discharge to Surface Water at Hanford Reactor Areas

The Hanford Site nuclear reactor operations required large quantities of high-quality cooling water, which was treated with chemicals including sodium dichromate dihydrate for corrosion control. Cooling water leakage, as well as intentional discharge of cooling water to ground during upset conditions, produced extensive groundwater recharge mounds consisting largely of contaminated cooling water and resulted in wide distribution of hexavalent chromium (Cr[VI]) contamination in the unconfined aquifer. The 2013 Cr(VI) groundwater plumes in the 100 Areas cover approximately 6 km2 (1500 acres), primarily in the 100-HR-3 and 100-KR-4 groundwater operable units (OUs). The Columbia River is a groundwater discharge boundary; where the plumes are adjacent to the Columbia River there remains a potential to discharge Cr(VI) to the river at concentrations above water quality criteria. The pump-and-treat systems along the River Corridor are operating with two main goals: 1) protection of the Columbia River, and 2) recovery of contaminant mass. An evaluation of the effectiveness of the pump-and-treat systems was needed to determine if the Columbia River was protected from contamination, and also to determine where additional system modifications may be needed. In response to this need, a technique for assessing the river protection was developed which takes into consideration seasonal migration of the plume and hydraulic performance of the operating well fields. Groundwater contaminant plume maps are generated across the Hanford Site on an annual basis. The assessment technique overlays the annual plume and the capture efficiency maps for the various pump and treat systems. The river protection analysis technique was prepared for use at the Hanford site and is described in detail in M.J. Tonkin, 2013. Interpolated capture frequency maps, based on mapping dynamic water level observed in observation wells and derived water levels in the vicinity of extraction and injection wells, are developed initially. Second, simulated capture frequency maps are developed, based on transport modelling results. Both interpolated and simulated capture frequency maps are based on operation of the systems over a full year. These two capture maps are then overlaid on the plume distribution maps for inspection of the relative orientation of the contaminant plumes with the capture frequency. To quantify the relative degree of protection of the river from discharges of Cr(VI) (and conversely, the degree of threat) at any particular location, a systematic method of evaluating and mapping the plume/capture relationship was developed. By comparing the spatial relationship between contaminant plumes and hydraulic capture frequency, an index of relative protectiveness is developed and the results posted on the combined plume/capture plan view map. Areas exhibiting lesser degrees of river protection are identified for remedial process optimization actions to control plumes and prevent continuing discharge of Cr(VI) to the river.

Miller, Chuck W.↗