Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface reflection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A first-principles approach to the optimization of neutron-focusing guide design and development

Fundamental optical concepts are utilized across all fields of scientific instrumentation. In the case of beam-like systems in neutron scattering instrumentation (low-divergence trajectories taken over long distances), quantities describing a system can be scaled into dimensionless figures of merit that convey performance characteristics and geometric limits. Furthermore, this first-principles approach facilitates a straight forward means by which to tailor an optical system to a defined source-sample configuration, as well as further inform guide surface shapes and reflectivity requirements. These principles will be presented and applied incorporated to examples showing their relevance to practical applications and future instrumentation.

Frost, Matthew J.↗

Nanoscale Superconducting States in the Fe-Based Filamentary Superconductor of Pr-Doped CaFe 2 As 2

The low-temperature scanning tunneling microscope and spectroscopy (STM/STS) are used to visualize superconducting states in the cleaved single crystal of 9% praseodymium-doped CaFe 2 As 2 (Pr-Ca122) with Tc ≈ 30 K. The spectroscopy shows strong spatial variations in the density of states (DOS), and the superconducting map constructed from spectroscopy discloses a localized superconducting phase, as small as a single unit cell. The comparison of the spectra taken at 4.2 K and 22 K (below vs. close to the bulk superconducting transition temperature) from the exact same area confirms the superconducting behavior. Nanoscale superconducting states have been found near Pr dopants, which can be identified using dI/dV conductance maps at +300 mV. There is no correlation of the local superconductivity to the surface reconstruction domain and surface defects, which reflects its intrinsic bulk behavior. We, therefore, suggest that the local strain of Pr dopants is competing with defects induced local magnetic moments; this competition is responsible for the local superconducting states observed in this Fe-based filamentary superconductor.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Geographically aware estimates of remotely sensed water properties for Chesapeake Bay

This software contains the code for a data-driven model to produce high-resolution (< 1 km2) estimates of temperature, salinity, and turbidity over decadal time scales as required by next-generation Earth Systems Models. Our model fits daily MODIS Aqua reflectance data to surface observations (< 1 m depth) from 2000-2021 in Chesapeake Bay, USA.

Stachelek, Jemma↗

Methods and systems for monitoring a solid-liquid interface

Methods and systems are provided for monitoring a solid-liquid interface, including providing a vessel configured to contain an at least partially melted material; detecting radiation reflected from a surface of a liquid portion of the at least partially melted material that is parallel with the liquid surface; measuring a disturbance on the surface; calculating at least one frequency associated with the disturbance; and determining a thickness of the liquid portion based on the at least one frequency, wherein the thickness is calculated based on.times. ##EQU00001## where g is the gravitational constant, w is the horizontal width of the liquid, and f is the at least one frequency.

Stoddard, Nathan G↗

Detection of exposure damage in composite materials using Fourier transform infrared technology.

Goal: to detect the subtle changes in laminate composite structures brought about by thermal, chemical, ultraviolet, and moisture exposure. Compare sensitivity of an array of NDI methods, including Fourier Transform Infrared Spectroscopy (FTIR), to detect subtle differences in composite materials due to deterioration. Inspection methods applied: ultrasonic pulse echo, through transmission ultrasonics, thermography, resonance testing, mechanical impedance analysis, eddy current, low frequency bond testing & FTIR. Comparisons between the NDI methods are being used to establish the potential of FTIR to provide the necessary sensitivity to non-visible, yet significant, damage in the resin and fiber matrix of composite structures. Comparison of NDI results with short beam shear tests are being used to relate NDI sensitivity to reduction in structural performance. Chemical analyses technique, which measures the infrared intensity versus wavelength of light reflected on the surface of a structure (chemical and physical information via this signature). Advances in instrumentation have resulted in hand-held portable devices that allow for field use (few seconds per scan). Shows promise for production quality assurance and in-service applications on composite aircraft structures (scarfed repairs). Statistical analysis on frequency spectrums produced by FTIR interrogations are being used to produce an NDI technique for assessing material integrity. Conclusions are: (1) Use of NDI to assess loss of composite laminate integrity brought about by thermal, chemical, ultraviolet, and moisture exposure. (2) Degradation trends between SBS strength and exposure levels (temperature and time) have been established for different materials. (3) Various NDI methods have been applied to evaluate damage and relate this to loss of integrity - PE UT shows greatest sensitivity. (4) FTIR shows promise for damage detection and calibration to predict structural integrity (short beam shear). (5) Detection of damage for medium exposure levels (possibly resin matrix degradation only) is more difficult and requires additional study. (6) These are initial results only - program is continuing with additional heat, UV, chemical and water exposure test specimens.

36 MATERIALS SCIENCE↗

Methods and systems for monitoring a solid-liquid interface

Methods and systems are provided for monitoring a solid-liquid interface, including providing a vessel configured to contain an at least partially melted material; detecting radiation reflected from a surface of a liquid portion of the at least partially melted material; providing sound energy to the surface; measuring a disturbance on the surface; calculating at least one frequency associated with the disturbance; and determining a thickness of the liquid portion based on the at least one frequency, wherein the thickness is calculated based on L=(2m-1)v.sub.s/4f, where f is the frequency where the disturbance has an amplitude maximum, v.sub.s is the speed of sound in the material, and m is a positive integer (1, 2, 3, . . . ).

36 MATERIALS SCIENCE↗

Exploring growth kinetics of carbon nanotube arrays by in situ optical diagnostics and modeling

Simple kinetic models of carbon nanotube growth have been able to successfully link together many experimental parameters involved in the growth of carbon nanotubes for practical applications including the prediction of growth rates, terminal lengths, number of walls, activation energies, and their dependences on the growth environment. The implications of recent experiments utilizing in situ monitoring of carbon nanotube growth on our past kinetic model are first reviewed. Then, sub-second pulsed feedstock gas introduction is discussed to explore the nucleation and initial growth of carbon nanotubes in the context of the kinetic model. Moreover, kinetic effects in "pulsed CVD" - using repeated pulsed gas introduction to stop and restart nanotube growth - are explored to understand renucleation, the origin of alignment in nanotube arrays, and incremental growth. Time-resolved reflectivity of the surface is used to remotely understand the kinetics of nucleation and the coordinated growth of arrays. This approach demonstrates that continuous vertically aligned single wall carbon nanotubes can be grown incrementally by pulsed CVD, and that the first exposure of fresh catalyst to feedstock gas is critical to nanotubes site density required for coordinated growth. Aligned nanotube arrays (as short as 60 nm) are shown to nucleate and grow within single, sub-second gas pulses. The multiple-pulse growth experiments (> 100 pulses) show that a high fraction of nanotubes renucleate on subsequent gas pulses.

Puretzky, Alexander A↗

Ultra-flat optical device with high transmission efficiency

An optical device includes a nanostructured transparent dielectric film, which is a Huygens metasurface. The Huygens metasurface imparts a phase change to light propagating through or reflecting from the surface. The phase change can be achieved by means of a resonant interaction between light and the Huygens resonators, resulting in a controllable phase change of 0 to 2π with approximately 100% light transmission characterized by a below 0.1 dielectric loss tangent of delta and with the height of the resonators less than the wavelength of light. In one embodiment, the metasurface includes titanium dioxide, but many materials or stacks of different materials may be used. The optical device is functional throughout the visible spectrum between 380 and 700 nm. The nanostructured transparent dielectric film includes a plurality of Huygens resonators. The phase and the amplitude of the nanostructured transparent dielectric film are modulated by arranging the plurality of Huygens resonators such that certain properties, including the radius and height of each Huygens resonator, as well as the gap between two adjacent Huygens resonators, are controlled to optimize the performance of the optical device within the visible spectrum.

Czaplewski, David A.↗

Tunable plasmonic color device and method of making the same

A plasmonic system is disclosed. The system includes at least one polarizer that is configured to provide at least one linearly polarized broadband light beam, an anisotropic plasmonic metasurface (APM) assembly having a plurality of nanoantennae each having a predetermined orientation with respect to a global axis representing encoded digital data, the APM assembly configured to receive the at least one linearly polarized broadband light beam and by applying localized surface plasmon resonance reflect light with selectable wavelengths associated with the predetermined orientations of the nanoantennae, and at least one analyzer that is configured to receive the reflected light with selectable wavelength, wherein the relative angles between each of the at least one analyzers and each of the at least one polarizers are selectable with respect to the global axis, thereby allowing decoding of the digital data.

Kildishev, Alexander V.↗

Study on mechanism of photocatalytic performance of La-doped TiO{sub 2}/Ti photoelectrodes by theoretical and experimental methods

TiO{sub 2} photoelectrodes with various nanostructures have been successfully prepared by the anodization method. The morphology, microstructure and optical properties of as-prepared photoelectrodes were studied by scanning electron microscopy (SEM), X-ray diffraction (XRD), ultraviolet/visible light diffuse reflectance spectra (UV/vis/DRS), surface photovoltage spectroscopy (SPS) and photocurrent. The electronic structure and optical properties of La doped/undoped TiO{sub 2} photoelectrodes with different crystal structures were calculated by the density function theory. The photocatalytic and photoelectrocatalytic activities of as-prepared photoelectrodes were evaluated. The results showed that the anodization potentials played a crucial role in the surface morphology and microstructure. Both results of theoretical calculations and experimental tests demonstrated that La-doped photoelectrodes were more sensitive to light than undoped one. The difference of photoelectrodes performance was ascribed to the crystal configuration, impurity energy levels and long-range orientation moving of photogenerated carriers. - Graphical abstract: Photophysical chemistry processes in as-prepared TiO{sub 2} photoelectrodes. Overall scheme of TiO{sub 2} photoelectrodes: (A) movement of photoelectrons and holes without bias potentials; (B) movement of photoelectrons and holes at applied bias potentials; (a) and (b) were the transmission of photogenerated electrons and holes of local enlargement of (A) (black open circle): (a) photoelectrons movement in P-TiO{sub 2} photoelectrodes and La-TiO{sub 2} photoelectrodes, the red dot line denotes the top of valence band (VB) and the bottom of conduction band (CB) of pure photoelectrodes; (b) photoelectrons movement in P-160 and La-160 TiO{sub 2} photoelectrodes (mixed crystal phase). The number refers to as follows: (1) transmission process of photoelectrons and holes; (2) recombination process of photoelectrons and holes. Arrows represent the moving direction of photoelectrons. Highlights: Black-Right-Pointing-Pointer Morphology and structure of La-doped photoelectrodes. Black-Right-Pointing-Pointer Band gap and electric structure of La-doped and undoped photoelectrodes. Black-Right-Pointing-Pointer Optical, PECH, PC and PEC properties of La-TiO{sub 2} photoelectrodes. Black-Right-Pointing-Pointer Transmission process of photoelectron-hole pairs in La-TiO{sub 2} photoelectrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Graphene: a Barrier to Hydrogen Permeation

Small area freestanding monolayer graphene has been shown to be impermeable to standard gases including hydrogen and helium.1 Several recent reports have suggested that graphene can be used as a hydrogen permeation barrier on metals.2 Those studies have relied on electrochemical hydrogen permeation measurements, which do a good job reproducing bulk permeability compared to gaseous diffusion but do not always reflect the real surface effects due to the difference in driving forces. This problem is magnified when measuring the permeability of thin coatings, which are dominated by surface effects. For this reason, we performed gas driven hydrogen permeation measurements of graphene coated metal samples. The diffusion of hydrogen through a metal can be described using Fick's and Sievert's Laws. Graphene-coated copper foils were prepared using chemical vapor deposition (CVD) with a methane precursor. Photo-reduced graphene samples were prepared by first sputtering a layer (∼15 nm) of copper on top of stainless steel foils. Graphene oxide in ethanol solutions were then drop cast on the surface and photo reduced using a neon lamp. A custom-designed apparatus has been assembled for measuring the hydrogen permeability of various materials. The operating principle of the system is as follows: A sample is sealed between the fore-sample and post-sample chambers using standard vacuum gaskets. Hydrogen is introduced into the fore sample region at varying pressures while the post sample region is maintained under high vacuum. Due to the concentration gradient, hydrogen then diffuses through the material and is detected using a quadrupole mass spectrometer. This process is repeated at several temperatures. The mass spectrometer was calibrated using an orifice with known conductance in place of the sample. Data collection and reduction were automated using scripts written in LabVIEW and Octave, respectively. We saw a decrease in the hydrogen permeability of copper after adding graphene to the surface for small temperature steps. This result is also observed when considering temperature steps of 20 K. Future Work: Apply this methodology to graphene-coated 316L stainless steel. The hydrogen permeability of 316L steel should also decrease with the addition of graphene to the surface. Determine methods for graphene defect reduction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Segregation of Chromium and Titanium in Sapphire Optical Fiber Grown via the Laser-Heated Pedestal Growth Technique

Our research involves growth of single crystal (SC) optical fibers to be used for sensing applications in harsh environments. Silica optical fibers are an affordable and reliable option for a wide variety of applications including optical fiber sensors and fiber lasers. However, for applications in harsh environments, such as high temperatures, radioactivity, corrosivity, etc., silica fibers are not suitable due to their instability under such conditions. Fibers composed of SC materials such as sapphire and YAG are mechanically, chemically, and thermally more robust to harsh conditions, and thus are more appropriate for sensing applications in environments such as nuclear reactors, jet engines, and boiler. However, SC fibers grown via the laser-heated pedestal growth (LHPG) technique do not intrinsically have a functional cladding layer. A cladding layer is required to reduce the modal volume for distributed sensing applications, to reduce frustrated total internal reflection induced by surface contact of the fiber in certain applications, and to improve transmissivity. Our lab investigates introduction of dopant materials during LHPG to induce an effective core-cladding structure while maintain the crystallinity of the host material. This process results in optical fiber that is not only robust to harsh environments, but also has improved optical properties for distributed sensor applications.

distributed sensing↗

High Density n-Si/n-TiO2 Core/Shell Nanowire Arrays with Enhanced Photoactivity

There are currently great needs to develop low-cost inorganic materials that can efficiently perform solar water splitting as photoelectrolysis of water into hydrogen and oxygen has significant potential to provide clean energy. We investigate the Si/TiO2 nanowire heterostructures to determine their potential for the photooxidation of water. We observed that highly dense Si/TiO2 core/shell nanowire arrays enhanced the photocurrent by 2.5 times compared to planar Si/TiO2 structure due to their low reflectance and high surface area. We also showed that n-Si/n-TiO2 nanowire arrays exhibited a larger photocurrent and open circuit voltage than p-Si/n-TiO2 nanowires due to a barrier at the heterojunction.

36 MATERIALS SCIENCE↗

Carbon contamination topography analysis of EUV masks

The impact of carbon contamination on extreme ultraviolet (EUV) masks is significant due to throughput loss and potential effects on imaging performance. Current carbon contamination research primarily focuses on the lifetime of the multilayer surfaces, determined by reflectivity loss and reduced throughput in EUV exposure tools. However, contamination on patterned EUV masks can cause additional effects on absorbing features and the printed images, as well as impacting the efficiency of cleaning process. In this work, several different techniques were used to determine possible contamination topography. Lithographic simulations were also performed and the results compared with the experimental data.

36 MATERIALS SCIENCE↗

Dissociation of trimethylgallium on the ZrB{sub 2}(0001) surface

X-ray photoelectron spectroscopy and reflection absorption infrared spectroscopy (RAIRS) have been used to study the dissociative adsorption of trimethylgallium (TMG) on the ZrB{sub 2}(0001) surface. Spectra were obtained as a function of annealing temperature following TMG exposure at temperatures of 95 and 300 K, and also as a function of TMG exposure for a surface temperature of 300 K. After annealing above 220 K, a significant decrease in the relative concentration of carbon and gallium occurred accompanied by a shift of ∼0.2 eV in the Ga 2p{sub 3/2} binding energy. The RAIR spectra show that after annealing to ∼220 K, only one CH{sub 3} deformation band at 1196 cm{sup −1} remains, the intensity of which is considerably decreased indicating loss of at least one methyl group from TMG. Further annealing leads to the sequential loss of the other methyl groups. The first methyl desorbs while the last two dissociate to deposit two C atoms per TMG molecule onto the ZrB{sub 2} surface.

36 MATERIALS SCIENCE↗

Simultaneous detection of surface coverage and structure of krypton films on gold by helium atom diffraction and quartz crystal microbalance techniques

We describe a quartz crystal microbalance setup that can be operated at low temperatures in ultra high vacuum with gold electrode surfaces acting as substrate surface for helium diffraction measurements. By simultaneous measurement of helium specular reflection intensity from the electrode surface and resonance frequency shift of the crystal during film adsorption, helium diffraction data can be correlated to film thickness. In addition, effects of interfacial viscosity on the helium diffraction pattern could be observed. To this end, first, flat gold films on AT cut quartz crystals were prepared which yield high enough helium specular reflection intensity. Then the crystals were mounted in the helium diffractometer sample holder and driven by means of a frequency modulation driving setup. Different crystal geometries were tested to obtain the best quality factor and preliminary measurements were performed on Kr films on gold surfaces. While the crystal structure and coverage of krypton films as a function of substrate temperature could successfully be determined, no depinning effects could be observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microjetting from grooved surfaces in metallic samples subjected to laser driven shocks

When a shock wave propagating in a solid sample reflects from a free surface, geometrical effects predominantly governed by the roughness and defects of that surface may lead to the ejection of tiny jets that may breakup into high velocity, approximately micrometer-size fragments. This process referred to as microjetting is a major safety issue for engineering applications such as pyrotechnics or armour design. Thus, it has been widely studied both experimentally, under explosive and impact loading, and theoretically. In this paper, microjetting is investigated in the specific loading conditions associated to laser shocks: very short duration of pressure application, very high strain rates, small spatial scales. Material ejection from triangular grooves in the free surface of various metallic samples is studied by combining transverse optical shadowgraphy and time-resolved velocity measurements. The influences of the main parameters (groove angle, shock pressure, nature of the metal) on jet formation and ejection velocity are quantified, and the results are compared to theoretical estimates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reflections of ions in electrostatic analyzers: A case study with New Horizons/Solar Wind Around Pluto

Electrostatic analyzers (ESAs), in various forms, are used to measure plasma in a range of applications. In this article, we describe how ions reflect from the interior surfaces of an ESA, the detection of which constitutes a fundamentally nonideal response of ESAs. We demonstrate this effect by comparing laboratory data from a real ESA-based space instrument, the Solar Wind Around Pluto (SWAP) instrument, aboard the NASA New Horizons spacecraft, to results from a model based on quantum mechanical simulations of particles reflected from the instrument's surfaces combined with simulations of particle trajectories through the instrument's applied electrostatic fields. Thus, we show, for the first time, how reflected ions in ESAs lead to nonideal effects that have important implications for understanding the data returned by these instruments, as well as for designing new low-background ESA-based instruments. Specifically, we show that the response of SWAP widens considerably below a level of 10{sup -3} of the peak response. Thus, a direct measurement of a plasma distribution with SWAP will have an energy-dependent background on the order of {<=}10{sup -3} of the peak of the signal due to that distribution. We predict that this order of magnitude estimate for the background applies to a large number of ESA-based instruments because ESAs operate using a common principle. However, the exact shape of the energy-dependent response will be different for different instruments. The principle of operation is that ions outside the ideal range of energy-per-charge are deflected into the walls of the ESA. Therefore, we propose that a new design paradigm is necessary to mitigate the effect of ion reflections and thus accurately and directly measure the energy spectrum of a plasma using ESAs. In this article, we build a framework for minimizing the effect of ion reflections in the design of new ESAs. Through the use of existing computer simulation software, a design team can use our method to quantify the amount of reflections in their instrument and iteratively change design parameters before fabrication, conserving resources. A possible direction for the new design paradigm is having nonsolid walls of the ESA, already used in some applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗