Search NASA⌕ Search

SEARCH · Search NASA

Results for “system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Solar-Powered Aerogel-Based Adsorptive Air Conditioning

The DOE estimates the total primary energy consumption for commercial buildings was 10.72 quadrillion BTU (quads) in 1983, compared with 14.74 quads for the residential sector. According to the DOE Building Technologies Program, 40–60% of the energy used in U.S. commercial (and residential) buildings is for HVAC, creating massive potential for energy savings with a system that could cut cooling energy use by at least 30–60%. Initial vertical segments in the commercial building market include government and commercial office buildings; government facilities such as prisons, military bases, and schools; hotels and resorts; farming, wineries and other rural facilities; and general light industrial offices (e.g., printers and clothing makers). We propose a solar powered aerogel-based adsorption cooling system, including the completion and testing of a working prototype at an existing HVAC testing facility and technology-maturation testing at an existing beta-testing site. In the cooling system, solar radiation is focused by solar collectors onto on bed, which contains ultra high surface area aerogel. Heating causes thermal desorption of a refrigerant previously adsorbed into the aerogel’s pores. Refrigerant desorption increases the gas-phase pressure in the pores, thereby forcing the gaseous refrigerant to flow out of the first irradiated bed (Bed A) and through a two-stage condenser. In the condenser, heat is first removed from the hot gaseous refrigerant by a stream of water that eventually flows into a hot water heater and storage system. The refrigerant is then further cooled by chilled refrigerant leaving the evaporator after vaporization. After passing through the two-stage condenser, the gaseous refrigerant undergoes expansion through an expansion valve. A portion of the refrigerant condenses in the evaporator, while some of the refrigerant is flashed and exits the evaporator. The evaporator absorbs heat from the area being cooled, which results in further vaporization of the refrigerant. The cool, vaporized refrigerant leaves the evaporator, passing through tubes in the shell-and-tube heat exchanger comprising the second stage of the two-stage condenser. After leaving the tube side of this heat exchanger, it flows to the second bed of aerogel (Bed B), which is maintained at a relatively low temperature by water entering the building and destined for the hot water tank. During the first cycle, most of the refrigerant adsorbs on Bed B. When the refrigeration cycle is reversed, the refrigerant is thermally desorbed from Bed B, and adsorbed on the cooler Bed A. As the cycling rate increases, the quantity of adsorption media, the system size, and the associated cost becomes smaller. It appears that an optimized system can meet targeted performance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of Variable Refrigerant Flow Systems Performance and the Enhanced Control Algorithm on Oak Ridge National Laboratory's Flexible Research Platform

A research project “Evaluation of Variable Refrigerant Flow (VRF) Systems Performance and the Enhanced Control Algorithm on Oak Ridge National Laboratory’s (ORNL’s) Flexible Research Platform” was performed to (1) install and validate the performance of Samsung VRF systems compared with the baseline rooftop unit (RTU) variable-air-volume (VAV) system and (2) evaluate the enhanced control algorithm for the VRF system on the two-story flexible research platform (FRP) in Oak Ridge, Tennessee. Based on the VRF system designed by Samsung and ORNL, the system was installed from February 18 through April 15, 2014. The final commissioning and system optimization were completed on June 2, 2014, and the initial test for system operation was started the following day, June 3, 2014. In addition, the enhanced control algorithm was implemented and updated on June 18. After a series of additional commissioning actions, the energy performance data from the RTU and the VRF system were monitored from July 7, 2014, through February 28, 2015. Data monitoring and analysis were performed for the cooling season and heating season separately, and the calibrated simulation model was developed and used to estimate the energy performance of the RTU and VRF systems. This final report includes discussion of the design and installation of the VRF system, the data monitoring and analysis plan, the cooling season and heating season data analysis, and the building energy modeling study

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capture Cavities for the CW Polarized Positron Source Ce+BAF

The initial design of the capture cavities for the continuous wave (CW) polarized positron beams at Jefferson Lab (Ce+BAF) is presented. A chain of standing wave multi-cell copper cavities inside a solenoid tunnel are selected to bunch/capture positrons. The cavity design strategy is presented to accommodate constrains from the large phase distribution of the incident beams, RF power, radiation and RF heating, beam loading, etc. to improve the capture efficiency. A matrix of design parameters' range are given for future system optimization when the capture cavities are considered together with other sub-systems and beam dynamics. The contents will also be useful for other CW cavity design for beams with large phase space distribution.

Wang, Shaoheng↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building ControlScore: Research Laboratory Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore tool which captures operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

IEA Wind Energy Task 37 - System Engineering - Aerodynamic Optimization Case Study

This paper presents the results from the first IEA Wind Task 37 aerodynamic optimization case study. 8 participants applied their optimization tools to a purely aerodynamic problem and the results were compared. Overall, the different tools produced widely different designs, while there was better agreement in the improvement achieved. This highlights the fact that further investigation is needed to try to understand these differences and develop best practices. There were too many differences between the different analysis and optimization codes to determine the sources of these differences. However, several potential sources of discrepancy were identified for further investigation. One hypothesis is that one potential source of discrepancy is that the design problem itself is relatively flat in design directions of constant loading. This flatness would impact the convergence in the optimization, while at the same time mean that discrepancies in the design itself would be less severe.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Programmed schedule holds for improving launch vehicle holds

Baseline definition and system optimization are used for the analysis of programmed holds developed through prelaunch system analysis. Identification of design specifications for ground support equipment and maintenance concepts, and design specifications are used to describe the functional utilization of the overall flow process.

Gralow, F. H.↗

Quiet STOL propulsion session introductory remarks

Research activities, preliminary design activities, and system optimization studies in support of the development of advanced, quiet, STOL propulsion systems are discussed. Noise alleviation by means of controlling the source and by means of acoustical treatment receive considerable emphasis. A STOL airplane designed for a given payload has essentially double the installed thrust of a comparable CTOL airplane. Unless compensated for during the design process, this alone will tend to increase the source noise by 3 db. The propulsive lift introduces flap impingement noise or duct and flap scrubbing noise, noise sources not present in CTOL airplanes to any significant degree. These additional noise sources are illustrated. Depending on the specific configuration, this will tend to increase the noise by several db or more. Although the propulsive lift characteristics of STOL airplanes will tend to increase source noise significantly, the proximity of STOL airfields to populated areas leads to STOL noise objectives considerably lower than those currently applicable to CTOL airplanes.

Schroeder, R. W.↗

Active optics simulation system

Set of three major computer program packages aids design of mirror control system for large telescopes. It can be used to evaluate merit of particular active optics control system (or component subsystem); and once system configuration is chosen, it can be used as design aid to optimize system parameters.

Source record↗

First Results from a Microfocus X-Ray System for Macromolecular Crystallography

The design and performance of a 40 Watt laboratory crystallography system optimized for the structure determination of small protein crystals are described. This system combines a microfocus x-ray generator (40 microns FWHM spot size at a power level of 40 Watts) and a short focal length (F = 2.6 mm) polycapillary collimating optic, and produces a small diameter quasi-parallel x-ray beam. Measurements of x-ray flux, divergence and spectral purity of the resulting x-ray beam are presented. The x-ray flux in a 250 microns diameter aperture produced by the microfocus system is 14.7 times higher .than that from a 3.15 kW rotating anode generator equipped with graphite monochromator. Crystallography data taken with the microfocus system are presented, and indicate that the divergence and spectral purity of the x-ray are sufficient to refine the diffraction data using a standard crystallographic software. Significant additional improvements in flux and beam divergence are possible, and plans for achieving these coals are discussed.

Gubarev, Mikhail↗

Remote Sensing System Requirements Development: A Simulation-Based Approach

Earth science research and application requirements for multispectral data have often been driven by currently available remote sensing technology. Few parametric studies exist that specify data required for certain applications. Consequently, data requirements are often defined based on the best data available or on what has worked successfully in the past. Since properites such as spatial resolution, swath width, spectral bands, signal-to-noise ratio (SNR), data quantization, and band-to-band registration drive sensor platform and spaceraft system architecture and cost, analysis of these criteria is important to objectively optimize system design. Remote sensing data requirements are also linked to calibration and characterization methods. Parameters such as spatial resolution, radiometric accuracy, and geopositional accuracy affect the complexity and cost of calibration methods. However, there are few studies that quantify the true accuracies required for specific problems. As calibration methods and standards are proposed, it is important that they be tied to well-known data requirements. The Application Research Toolbox (ART) developed at Stennis Space Center provides a simulation-based method for multispectral data requirements development. The ART produces simulated data sets from hyperspectral data through band synthesis. Parameters such as spectral band shape and width, SNR, data quantization, spatial resolution, and band-to-band registration can be varied to create many different simulated data products. Simulated data utility can then be assessed for different applications so that requirements can be better understood. This paper describes the ART and its applicability for rigorously deriving remote sensing data requirements.

Zanoni, Vicki↗

IEA Wind Energy Task 37 System Engineering Aerodynamic Optimization Case Study: Preprint

This paper presents the results from the first IEA Wind Task 37 aerodynamic optimization case study. Eight participants applied their optimization tools to a purely aerodynamic problem and the results were compared. Overall, the different tools produced widely different designs, while there was better agreement in the improvement achieved. This highlights the fact that further investigation is needed to try to understand these differences and develop best practices. There were too many differences between the different analysis and optimization codes to determine the sources of these differences. However, several potential sources of discrepancy were identified for further investigation. One hypothesis is that one potential source of discrepancy is that the design problem itself is relatively flat in design directions of constant loading. This flatness would impact the convergence in the optimization, and at the same time mean that discrepancies in the design itself would be less severe.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Development of a parameter optimization technique for the design of automatic control systems

Parameter optimization techniques for the design of linear automatic control systems that are applicable to both continuous and digital systems are described. The model performance index is used as the optimization criterion because of the physical insight that can be attached to it. The design emphasis is to start with the simplest system configuration that experience indicates would be practical. Design parameters are specified, and a digital computer program is used to select that set of parameter values which minimizes the performance index. The resulting design is examined, and complexity, through the use of more complex information processing or more feedback paths, is added only if performance fails to meet operational specifications. System performance specifications are assumed to be such that the desired step function time response of the system can be inferred.

Whitaker, P. H.↗

Thermal protection optimization for the space shuttle.

This paper discusses optimal entry trajectories for the space shuttle that minimize the weight of an entry thermal protection system. The analysis was made using mathematical models of two types of thermal protection systems that were under consideration for the space shuttle: a metallic thermal protection system, and a reusable surface insulation thermal protection system. Optimal entries were generated using maximum orbiter nose temperature as a parameter. Thermal protection system weights were computed for both fixed and variable angles of attack using three-dimensional entry trajectories. Results indicated that variable angle-of-attack entries require less thermal protection system weight than entries at a constant angle of attack (35 deg) for both systems considered. Results also showed that 95 to 99 per cent of the thermal protection system weight requirement resulted from flight regimes in which the flow was still laminar.

Garcia, F., Jr.↗

Smart distribution systems

The increasing importance of system reliability and resilience is changing the way distribution systems are planned and operated. To achieve a distribution system self-healing against power outages, emerging technologies and devices, such as remote-controlled switches (RCSs) and smart meters, are being deployed. The higher level of automation is transforming traditional distribution systems into the smart distribution systems (SDSs) of the future. The availability of data and remote control capability in SDSs provides distribution operators with an opportunity to optimize system operation and control. In this paper, the development of SDSs and resulting benefits of enhanced system capabilities are discussed. A comprehensive survey is conducted on the state-of-the-art applications of RCSs and smart meters in SDSs. Specifically, a new method, called Temporal Causal Diagram (TCD), is used to incorporate outage notifications from smart meters for enhanced outage management. To fully utilize the fast operation of RCSs, the spanning tree search algorithm is used to develop service restoration strategies. Optimal placement of RCSs and the resulting enhancement of system reliability are discussed. Distribution system resilience with respect to extreme events is presented. Furthermore, test cases are used to demonstrate the benefit of SDSs. Active management of distributed generators (DGs) is introduced. Future research in a smart distribution environment is proposed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Metrics for Energy Resilience

Energy lies at the backbone of any advanced society and constitutes an essential prerequisite for economic growth, social order and national defense. However there is an Achilles heel to today?s energy and technology relationship; namely a precarious intimacy between energy and the fiscal, social, and technical systems it supports. Recently, widespread and persistent disruptions in energy systems have highlighted the extent of this dependence and the vulnerability of increasingly optimized systems to changing conditions. Resilience is an emerging concept that offers to reconcile considerations of performance under dynamic environments and across multiple time frames by supplementing traditionally static system performance measures to consider behaviors under changing conditions and complex interactions among physical, information and human domains. This paper identifies metrics useful to implement guidance for energy-related planning, design, investment, and operation. Recommendations are presented using a matrix format to provide a structured and comprehensive framework of metrics relevant to a system?s energy resilience. The study synthesizes previously proposed metrics and emergent resilience literature to provide a multi-dimensional model intended for use by leaders and practitioners as they transform our energy posture from one of stasis and reaction to one that is proactive and which fosters sustainable growth.

99 GENERAL AND MISCELLANEOUS↗

Designing robust energy policy packages under deep uncertainty: A multi-metric decision support framework

The complexity of transitioning to sustainable energy systems requires policy frameworks capable of balancing multiple objectives while addressing deep uncertainty. However, existing approaches often lack systematic methods to identify combinations of policy levers that remain effective across a wide range of uncertain futures. This paper presents a novel decision support framework that guides the selection of robust policy packages based on their performance across multiple objectives under uncertainty. Our method leverages a large ensemble of scenarios and applies scenario discovery techniques to identify influential policy levers. Here, we introduce new indicators to assess the robustness of policies by evaluating their ability to mitigate adverse outcomes across metrics. These indicators support an iterative process to build a robust policy package. Finally, we map the technological and energy pathways associated with the robust policy package by leveraging an energy system optimization model. We illustrate the application of this framework to the Spanish energy system, providing insights into how specific combinations of policy levers shape decarbonization pathways under uncertainty.

Decision-support method↗