Search NASA⌕ Search

SEARCH · Search NASA

Results for “system testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Propagating Parameter Uncertainty in Power System Nonlinear Dynamic Simulations Using a Koopman Operator-Based Surrogate Model

In this work, we propose a Koopman operator-based surrogate model for propagating parameter uncertainties in power system nonlinear dynamic simulations. First, we augment a priori known state-space model by reformulating parameters deemed uncertain as pseudo-state variables. Then, we apply the Koopman operator theory to the resulting state-space model and obtain a linear dynamical system model. This transformation allows us to analyze the evolution of the system dynamics through its Koopman eigenfunctions, eigenvalues, and modes. Of particular importance for this letter, the obtained linear dynamical system is a surrogate that enables the evaluation of parameter uncertainties by simply perturbing the initial conditions of the Koopman eigenfunctions associated with the pseudo-state variables. Simulations carried out on the New England test system reveal the excellent performance of the proposed method in terms of accuracy and computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection of gas leakage

A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

Three-dimensional ultrasonic imaging of concrete elements using different SAFT data acquisition and processing schemes

Ultrasonic testing systems using transducer arrays and the SAFT (Synthetic Aperture Focusing Technique) reconstruction allow for imaging the internal structure of concrete elements. At one-sided access, three-dimensional representations of the concrete volume can be reconstructed in relatively great detail, permitting to detect and localize objects such as construction elements, built-in components, and flaws. Different SAFT data acquisition and processing schemes can be utilized which differ in terms of the measuring and computational effort and the reconstruction result. In this contribution, two methods are compared with respect to their principle of operation and their imaging characteristics. The first method is the conventional single-channel SAFT algorithm which is implemented using a virtual transducer that is moved within a transducer array by electronic switching. The second method is the Combinational SAFT algorithm (C-SAFT), also named Sampling Phased Array (SPA) or Full Matrix Capture/Total Focusing Method (TFM/FMC), which is realized using a combination of virtual transducers within a transducer array. Five variants of these two methods are compared by means of measurements obtained at test specimens containing objects typical of concrete elements. The automated SAFT imaging system FLEXUS is used for the measurements which includes a three-axis scanner with a 1.0 m × 0.8 m scan range and an electronically switched ultrasonic array consisting of 48 transducers in 16 groups. On the basis of two-dimensional and three-dimensional reconstructed images, qualitative and some quantitative results of the parameters image resolution, signal-to-noise ratio, measurement time, and computational effort are discussed in view of application characteristics of the SAFT variants.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Study of Eutectic Molten Salts NaCl/KCl/ZnCl2 Heat Transfer Inside a Smooth Tube for High-Temperature Application

Abstract Eutectic salts NaCl-KCl-ZnCl2 and NaCl-KCl-MgCl2 are two of the chloride salt systems that are promising for being used as high-temperature heat transfer fluid (HTF) and thermal energy storage (TES) materials in a wide range of temperatures from 230 °C to 750 °C in concentrated solar thermal power systems. To conduct measurement of the heat transfer coefficient of the molten salt at high temperatures, a circulation system and instrumentation of flow and heat transfer was constructed. Experimental measurement of the convective heat transfer coefficients of NaCl-KCl-ZnCl2 (molar fraction: 13.8–41.9–44.3%) inside tubes has been accomplished to find the most suitable heat transfer correlations. Experience of salt processing and operation of the high-temperature heat transfer test system was obtained. Two correlations, Dittus-Boelter equation and Gnielinski’s correlation for Nusselt number against Reynolds number and Prandtl number, are evaluated using the test results, and the latter correlation is recommended due to its better agreement of prediction against tested data.

Energy & Fuels↗

Nuclear cusps and singularities in the nonadditive kinetic potential bifunctional from analytical inversion

The non-additive kinetic potential $v^{\text{NAD}}$ is a key quantity in density-functional theory (DFT) embedding methods, such as frozen density embedding theory and partition DFT. $v^{\text{NAD}}$ is a bi-functional of electron densities $\rho_{\rm B}$ and $\rho_{\rm tot} = \rho_{\rm A} + \rho_{\rm B}$. It can be evaluated using approximate kinetic-energy functionals, but accurate approximations are challenging. The behavior of $v^{\text{NAD}}$ in the vicinity of the nuclei has long been questioned, and singularities were seen in some approximate calculations. In this article, the existence of singularities in $v^{\text{NAD}}$ is analyzed analytically for various choices of $\rho_{\rm B}$ and $\rho_{\rm tot}$, using the nuclear cusp conditions for the density and Kohn-Sham potential. It is shown that no singularities arise from smoothly partitioned ground-state Kohn-Sham densities. We confirm this result by numerical calculations on diatomic test systems HeHe, HeLi$^+$, and H$_2$, using analytical inversion to obtain a numerically exact $v^{\rm NAD}$ for the local density approximation. We examine features of $v^{\rm NAD}$ which can be used for development and testing of approximations to $v^{\rm NAD}[\rho_{\rm B},\rho_{\rm tot}]$ and kinetic-energy functionals.

74 ATOMIC AND MOLECULAR PHYSICS↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part I: Short Term Faults

Power system planning is the process of forecasting load demand and ensuring sufficient generation and reserve capacities over some planning horizon. This process includes investigation of steady-state and dynamic operation of power system of interest. This paper addresses the transient stability (also known as large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability and frequency response for all fault types for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted components present and is applicable to the study of both short term and long term faults, though only short term faults are considered here (long term faults are treated sequentially in a companion paper). Furthermore, this paper considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

ASC ATDM Level 2 Milestone #6015: Asynchronous Many-Task Software Stack Demonstration

This report is an outcome of the ASC ATDM Level 2 Milestone 6015: Asynchronous Many-Task Software Stack Demonstration. It comprises a summary and in depth analysis of DARMA and a DARMA-compliant Asynchronous Many-Task (AMT) runtime software stack. Herein performance and productivity of the over- all approach are assessed on benchmarks and proxy applications representative of the Sandia ATDM applications. As part of the effort to assess the perceived strengths and weaknesses of AMT models compared to more traditional methods, experiments were performed on ATS-1 (Advanced Technology Systems) test bed machines and Trinity. In addition to productivity and performance assessments, this report includes findings on the generality of DARMAs backend API as well as findings on interoperability with node- level and network-level system libraries. Together, this information provides a clear understanding of the strengths and limitations of the DARMA approach in the context of Sandias ATDM codes, to guide our future research and development in this area.

97 MATHEMATICS AND COMPUTING↗

Visualizing Electrical Power Systems as Flow Fields

We describe a method for visualizing data flows on large networks. We transform data flow on fixed networks into a vector field, which can be directly visualized using scientific flow visualization techniques. We evaluated the method on power flowing through two transmission power networks: a small, regional, IEEE test system (RTS-96) and a large national-scale system (the Eastern Interconnection). For the larger and more complex transmission system, the method illustrates features of the power flow that are not accessible when visualizing the power transmission with traditional network visualization techniques.

97 MATHEMATICS AND COMPUTING↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part II: Long Term Faults

Here, this paper addresses the transient stability (also called large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability, and frequency response for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted system' components present and is applicable to the study of both short term and long term faults. Part I of this research discussed the short term faults whereas as Part II, the present paper, discusses long term faults. This research considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000 MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

An Information Theoretic Approach to Identify Dominant Voltage Influencers for Unbalanced Distribution Systems

Smart distribution grid with multiple renewable energy sources can experience random voltage fluctuations due to variable generation, which may result in voltage violations. Traditional voltage control algorithms are inadequate to handle fast voltage variations. Therefore, new dynamic control methods are being developed that can significantly benefit from the knowledge of dominant voltage influencer (DVI) nodes. DVI nodes for a particular node of interest refer to nodes that have a relatively high impact on the voltage fluctuations at that node. Conventional power flow-based algorithms to identify DVI nodes are computationally complex, which limits their use in real-time applications. This paper proposes a novel information theoretic voltage influencing score (VIS) that quantifies the voltage influencing capacity of nodes with DERs/active loads in a three phase unbalanced distribution system. VIS is then employed to rank the nodes and identify the DVI set. VIS is derived analytically in a computationally efficient manner and its efficacy to identify DVI nodes is validated using the IEEE 37-node test system. It is shown through experiments that KL divergence and Bhattacharyya distance are effective indicators of DVI nodes with an identifying accuracy of more than 90%. Additionally, the computation burden is also reduced by an order of 5, thus providing the foundation for efficient voltage control.

42 ENGINEERING↗

Parallel File System I/O Performance Testing On LANL Clusters

These are slides from a presentation on parallel file system I/O performance testing on LANL clusters. I/O is a known bottleneck for HPC applications. Performance optimization of I/O is often required. This summer project entailed integrating IOR under Pavilion and automating the results analysis. The slides cover the following topics: scope of the work, tools utilized, IOR-Pavilion test workflow, build script, IOR parameters, how parameters are passed to IOR, *run_ior: functionality, Python IOR-Output Parser, Splunk data format, Splunk dashboard and features, and future work.

97 MATHEMATICS AND COMPUTING↗

Subtask 2.18 - Advancing CO 2 Capture Technology: Partnership for CO 2 Capture (PCO 2 C) Phase III

Industries and utilities continue to investigate ways to decrease their carbon footprint. Carbon capture and storage (CCS) can enable existing power generation facilities to meet the current national CO 2 reduction goals. The Partnership for CO2 Capture Phase III focused on several important research areas in an effort to find ways to decrease the cost of capture across both precombustion and postcombustion platforms. Two flue gas pretreatment technologies for postcombustion capture, an SO 2 reduction scrubbing technology from Cansolv Technologies Inc. and the Tri-Mer filtration technology that combines particulate, NOx, and SO 2 control, were evaluated on the Energy & Environmental Research Center’s (EERC’s) pilot-scale test system. Pretreating the flue gas should enable more efficient, and therefore less expensive, CO 2 capture. Both technologies were found to be effective in pretreating flue gas prior to CO 2 capture. Two new postcombustion capture solvents were tested, one from the Korea Carbon Capture and Sequestration R&D Center (KCRC) and one from CO 2 Solutions Incorporated. Both of these solvents showed the ability to capture CO 2 while requiring less regeneration energy, which would reduce the cost of capture. Hydrogen separation membranes from Commonwealth Scientific and Industrial Research Organisation were evaluated through precombustion testing. They are composed of vanadium alloy, which is less expensive than the palladium alloys that are typically used. Their performance was comparable to that of other membranes that have been tested at the EERC. Aspen Plus® software was used to model the KCRC and CO 2 Solutions solvents and found that they would result in significantly improved overall plant performance. The modeling effort also showed that the parasitic steam load at partial capture of 45% is less than half that of 90% overall capture, indicating savings that could be accrued if 90% capture is not required. Modeling of three regional power plants using the Carnegie Mellon Integrated Environmental Control Model showed that, among other things, the use of a bypass during partial capture may minimize the size of the capture tower(s) and result in a slight reduction in the revenue required to operate the capture facility. The results reinforced that a one-size-fits-all approach cannot be taken to adding capture to a power plant. Laboratory testing indicated that Fourier transform infrared spectroscopy could be used to continuously sample stack emissions at CO 2 capture facilities to detect and quantify any residual amine or its degradation products, particularly nitrosamines. The information gathered during Phase III is important for utility stakeholders as they determine how to reduce their CO 2 emissions in a carbon-constrained world. This subtask was funded through the EERC–U.S. Department of Energy (DOE) Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the North Dakota Industrial Commission, PPL Montana, Nebraska Public Power District, Tri-Mer Corporation, Montana–Dakota Utilities Co., Basin Electric Power Cooperative, KCRC/Korean Institute of Energy Research, Cansolv Technologies, and CO 2 Solutions, Inc.

01 COAL, LIGNITE, AND PEAT↗

Reliability enhancement of APR + diverse protection system regarding common cause failures

The Advanced Power Reactor Plus (APR +) nuclear power plant design has been developed on the basis of the APR1400 (Advanced Power Reactor 1400 MWe) to further enhance safety and economics. For the mitigation of Anticipated Transients Without Scram (ATWS) as well as Common Cause Failures (CCF) within the Plant Protection System (PPS) and the Emergency Safety Feature - Component Control System (ESF-CCS), several design improvement features have been implemented for the Diverse Protection System (DPS) of the APR + plant. As compared to the APR1400 DPS design, the APR + DPS has been designed to provide the Safety Injection Actuation Signal (SIAS) considering a large break LOCA accident concurrent with the CCF. Additionally several design improvement features, such as channel structure with redundant processing modules, and changes of system communication methods and auto-system test methods, are introduced to enhance the functional reliability of the DPS. Therefore, it is expected that the APR + DPS can provide an enhanced safety and reliability regarding possible CCF in the safety-grade I and C systems as well as the DPS itself. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Biochar Classification System and Associated Test Methods

In this chapter, a biochar classification system related to its use as soil amendment is proposed. This document builds upon previous work: “Standardized product definition and product testing guidelines for biochar that is used in soil” (IBI, 2015) (aka IBI Biochar Standards) and “Guidelines for biochar production for a sustainable production of biochar: European Biochar Certificate” (EBC, 2012-2022) (aka EBC Biochar Standards). It should be noted that the EBC guidelines constitute the basis for biochar certification through the independent government accredited inspection agency, Bio.Inspecta AG. The present document constrains its scope to materials with properties that satisfy the criteria for biochar as defined by either the IBI Biochar Standards or the EBC Standards (Annex I), as required by the current methodologies developed for accounting carbon credits associated with the biochar use in the voluntary market (e.g., Verra, Puro.Earth). The classification system envisions enabling stakeholders and commercial entities to (i) identify the most suitable biochar to fulfil the requirements for a particular soil and/or land-use, (ii) distinguish the application of biochar for specific niches (e.g., soilless agriculture), and (iii) assess the climate-impact value based on biochar properties, production efficiency, and alternative feedstock uses. It is based on the best current knowledge and will need to be improved as new data and knowledge become available in the scientific literature.

biochar, climate change impacts, soil amendment, c↗

CyPhyR: a cyber‐physical analysis tool for measuring and enabling resiliency in microgrids

This study presents a tool to study the cyber‐physical resiliency (CyPhyR) of critical energy infrastructure system, in particular the effect of cyber attacks on the microgrid's resiliency. The developed tool enables measuring resiliency using data from cyber and physical systems and suggests control decisions for resilient planning and operation of the microgrid. The microgrid resiliency is formulated based on graph theory based indices and cyber‐power system characteristics. A Common Vulnerability Scoring System based metric called the Cyber Asset Impact Potential is developed and used in the planning phase, and another metric, Cyber Impact Severity is introduced to study the system performance in the operational phase. The information from these two phases is provided to the operator to make informed and proactive decisions to ensure the resilient operation of the microgrid. The performance of the developed tool has been tested using comprehensive real‐time cyber‐power testbed for a Consortium for Electric Reliability Technology Solutions microgrid test system.

Venkataramanan, Venkatesh↗

Locational Marginal Pricing in the Campus Power System at the Power Distribution Level

In the development of smart grid at distribution level, the realization of real-time nodal pricing is one of the key challenges. The research work in this paper implements and studies the methodology of locational marginal pricing at distribution level based on a real-world distribution power system. The pricing mechanism utilizes optimal power flow to calculate the corresponding distributional nodal prices. Both Direct Current Optimal Power Flow and Alternate Current Optimal Power Flow are utilized to calculate and analyze the nodal prices. The University of Denver campus power grid is used as the power distribution system test bed to demonstrate the pricing methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operational and Mission Highlights A Monthly Summary of Top Achievements April 2022

When the Laboratory’s Detonator Production team originally completed manufacturing two ALT939 DEV#1 functional cables — the first development units produced in this lot, team members quickly hit an obstacle when electrical testing for these cables failed. Team members sent the cables out for further testing, which revealed the root cause of failure involved the cables’ connectors. Although a challenging issue to resolve, the team worked together and solved the issue ahead of a stipulated deadline, with the cables completed and shipped to support system tests. The team responsible for this challenging work included members from Detonator Production, Nondestructive Testing & Evaluation, and collaborators from Sandia National Laboratories.

42 ENGINEERING↗