Search NASA⌕ Search

SEARCH · Search NASA

Results for “temporal resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Estimation of the fractional coverage of rainfall in climate models

The fraction of the grid cell area covered by rainfall, mu, is an essential parameter in descriptions of land surface hydrology in climate models. A simple procedure is presented for estimating this fraction, based on extensive observations of storm areas and rainfall volumes. Storm area and rainfall volume are often linearly related; this relation can be used to compute the storm area from the volume of rainfall simulated by a climate model. A formula is developed for computing mu, which describes the dependence of the fractional coverage of rainfall on the season of the year, the geographical region, rainfall volume, and the spatial and temporal resolution of the model. The new formula is applied in computing mu over the Amazon region. Significant temporal variability in the fractional coverage of rainfall is demonstrated. The implications of this variability for the modeling of land surface hydrology in climate models are discussed.

Eltahir, E. A. B.↗

EUNIS; Extreme-Ultraviolet Normal-Incidence Spectrometer

GSFC is in the process of assembling an Extreme-Ultraviolet Normal Incidence Spectrometer called EUNIS, to be flown as a sounding rocket payload. The instrument builds on the many technical innovations pioneered by our highly successful SERTS experiment, which has now flown a total of ten times, most recently last summer. The new design will have somewhat improved spatial and spectral resolutions, as well as two orders of magnitude greater sensitivity, permitting high signal/noise EUV spectroscopy with a temporal resolution near 1 second for the first time ever. In order to achieve such high time cadence, a novel detector system is being developed, based on Active-Pixel-Sensor electronics, a key component of our design.

Thomas, Roger J.↗

High current table-top setup for femtosecond gas electron diffraction

Here, we have constructed an experimental setup for gas phase electron diffraction with femtosecond resolution and a high average beam current. While gas electron diffraction has been successful at determining molecular structures, it has been a challenge to reach femtosecond resolution while maintaining sufficient beam current to retrieve structures with high spatial resolution. The main challenges are the Coulomb force that leads to broadening of the electron pulses and the temporal blurring that results from the velocity mismatch between the laser and electron pulses as they traverse the sample. We also present here a device that uses pulse compression to overcome the Coulomb broadening and deliver femtosecond electron pulses on a gas target. The velocity mismatch can be compensated using laser pulses with a tilted intensity front to excite the sample. The temporal resolution of the setup was determined with a streak camera to be better than 400 fs for pulses with up to half a million electrons and a kinetic energy of 90 keV. Finally, the high charge per pulse, combined with a repetition rate of 5 kHz, results in an average beam current that is between one and two orders of magnitude higher than previously demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prior data assisted compressed sensing: A novel MR imaging strategy for real time tracking of lung tumors

Purpose: Hybrid radiotherapy-MRI devices promise real time tracking of moving tumors to focus the radiation portals to the tumor during irradiation. This approach will benefit from the increased temporal resolution of MRI's data acquisition and reconstruction. In this work, the authors propose a novel spatial-temporal compressed sensing (CS) imaging strategy for the real time MRI–-prior data assisted compressed sensing (PDACS), which aims to improve the image quality of the conventional CS without significantly increasing reconstruction times. Methods: Conventional 2D CS requires a random sampling of partial k-space data, as well as an iterative reconstruction that simultaneously enforces the image's sparsity in a transform domain as well as maintains the fidelity to the acquired k-space. PDACS method requires the additional acquisition of the prior data, and for reconstruction, it additionally enforces fidelity to the prior k-space domain similar to viewsharing. In this work, the authors evaluated the proposed PDACS method by comparing its results to those obtained from the 2D CS and viewsharing methods when performed individually. All three methods are used to reconstruct images from lung cancer patients whose tumors move and who are likely to benefit from lung tumor tracking. The patients are scanned, using a 3T MRI, under free breathing using the fully sampled k-space with 2D dynamic bSSFP sequence in a sagittal plane containing lung tumor. These images form a reference set for the evaluation of the partial k-space methods. To create partial k-space, the fully sampled k-space is retrospectively undersampled to obtain a range of acquisition acceleration factors, and reconstructed with 2D-CS, PDACS, and viewshare methods. For evaluation, metrics assessing global image artifacts as well as tumor contour shape fidelity are determined from the reconstructed images. These analyses are performed both for the original 3T images and those at a simulated 0.5T equivalent noise level. Results: In the 3.0T images, the PDACS strategy is shown to give superior results compared to viewshare and conventional 2D CS using all metrics. The 2D-CS tends to perform better than viewshare at the low acceleration factors, while the opposite is true at the high acceleration factors. At simulated 0.5T images, PDACS method performs only marginally better than the viewsharing method, both of which are superior compared to 2D CS. The PDACS image reconstruction time (0.3 s/image) is similar to that of the conventional 2D CS. Conclusions: The PDACS method can potentially improve the real time tracking of moving tumors by significantly increasing MRI's data acquisition speeds. In 3T images, the PDACS method does provide a benefit over the other two methods in terms of both the overall image quality and the ability to accurately and automatically contour the tumor shape. MRI's data acquisition may be accelerated using the simpler viewsharing strategy at the lower, 0.5T magnetic field, as the marginal benefit of the PDACS method may not justify its additional reconstruction times.

60 APPLIED LIFE SCIENCES↗

Interpretation of Fracture Initiation Points by In-Well Low-Frequency Distributed Acoustic Sensing in Horizontal Wells

Summary Low-frequency distributed acoustic sensing (LF-DAS) exploits the optical phase shift of Rayleigh backscatter in fiber-optic cables to obtain distributed measurements of changes in strain and temperature. Fiber-optic cables are often installed for multistage hydraulic fracture diagnostics in horizontal wells. LF-DAS in an untreated well provides far-field strain measurements, while offset wells are hydraulically fractured. Such a configuration is called crosswell LF-DAS sensing. Crosswell LF-DAS measurements have proved useful in diagnosing fracture hits, fracture azimuth, planarity, cluster efficiency, fracture propagation rates, and the dynamic distance to the fracture front. In contrast, in-well LF-DAS is conducted on the actively fractured well. Due to cool fracture fluid being injected at high injection rates, the strain component of the LF-DAS response is largely obscured by temperature changes. In permanent fiber-optic cable installations, distributed temperature sensing (DTS) is often conducted simultaneously with LF-DAS. An opportunity exists to decouple the temperature and strain components of LF-DAS sensors to observe strain changes on in-well LF-DAS. The LF-DAS response is modeled as linearly dependent on strain and temperature changes. Theoretical LF-DAS temperature and strain sensitivity coefficients are derived based on the changes to the index of refraction and length of the fiber. Using the DTS measurements, temperature changes are computed, smoothed, filtered, and compared to the LF-DAS response. Crossplots of the in-well LF-DAS measurements and temperature changes from DTS measurements far from the actively fractured region are used to validate the theoretical sensitivity coefficients. Uncertainty in the temperature component of the LF-DAS response is quantified. The difficulty in corresponding the different spatial and temporal resolutions of the DTS and LF-DAS measurements is overcome by comparing the responses over a moving temporal and spatial window. If the LF-DAS response at the center of the window agrees with the DTS response within uncertainty, the measurement is filtered out. After filtering, the remaining nonzero in-well LF-DAS measurements are due to changes in strain. The data are then visualized in waterfall plots. The results indicate that the theoretical and observed strain and temperature coefficients agree within 10%. After the temperature component of the in-well LF-DAS response is extracted, the remaining nonzero measurements are located primarily within the actively treated region. Locations with peaks in the strain response are interpreted to indicate fracture initiation points. These fracture initiation points are compared with in-well DTS and high-frequency DAS noise measurements across multiple stages to better understand fracture initiation along the horizontal well.

Engineering↗

The Ocean Colour Climate Change Initiative: II. Spatial and Temporal Homogeneity of Satellite Data Retrieval Due to Systematic Effects in Atmospheric Correction Processors

The established procedure to access the quality of atmospheric correction processors and their underlying algorithms is the comparison of satellite data products with related in-situ measurements. Although this approach addresses the accuracy of derived geophysical properties in a straight forward fashion, it is also limited in its ability to catch systematic sensor and processor dependent behaviour of satellite products along the scan-line, which might impair the usefulness of the data in spatial analyses. The Ocean Colour Climate Change Initiative (OC-CCI) aims to create an ocean colour dataset on a global scale to meet the demands of the ecosystem modelling community. The need for products with increasing spatial and temporal resolution that also show as little systematic and random errors as possible, increases. Due to cloud cover, even temporal means can be influenced by along-scanline artefacts if the observations are not balanced and effects cannot be cancelled out mutually. These effects can arise from a multitude of results which are not easily separated, if at all. Among the sources of artefacts, there are some sensor-specific calibration issues which should lead to similar responses in all processors, as well as processor-specific features which correspond with the individual choices in the algorithms. A set of methods is proposed and applied to MERIS data over two regions of interest in the North Atlantic and the South Pacific Gyre. The normalised water leaving reflectance products of four atmospheric correction processors, which have also been evaluated in match-up analysis, is analysed in order to find and interpret systematic effects across track. These results are summed up with a semi-objective ranking and are used as a complement to the match-up analysis in the decision for the best Atmospheric Correction (AC) processor. Although the need for discussion remains concerning the absolutes by which to judge an AC processor, this example demonstrates clearly, that relying on the match-up analysis alone can lead to misjudgement.

Ocean Colour↗

Asynchronous space–time domain decomposition method with localized uncertainty quantification

The computational cost associated with uncertainty quantification of engineering problems featuring localized phenomenon can be reduced by confining the random variability of the model parameters within a region of interest. Here in this case, a localized treatment of mesh and time resolutions is required to capture the effect of the confined material uncertainty on the global response. We present a computational approach for localized uncertainty quantification with the capability of asynchronous treatment of mesh and time resolutions. In particular, we allow each subdomain to have its local uncertainty representation and the corresponding mesh and time resolutions. As a result, computing resources can be directed toward a small region of interest where a model with high spatial and temporal resolutions is required. To verify the numerical implementation, we consider elastic wave propagation in an axially loaded beam. Moreover, we perform convergence studies with respect to the spatial and temporal discretizations as well as the size of an uncertain subdomain. A projectile impacting a composite sandwich plate is considered as an engineering application for the proposed method.

42 ENGINEERING↗

Multiscale dynamic experiments on fiber-reinforced composites with damage assessment using high-speed synchrotron X-ray phase-contrast imaging

We report fiber-reinforced composites (FRCs) have been widely used as protection materials to replace heavier metals. However, predictive capabilities for the impact-induced failure of FRCs have not been well-developed. In this work, we introduced an integrated technique to visualize the dynamic failure of FRCs, with the modified Kolsky bar loading and the high-speed synchrotron X-ray phase-contrast imaging (PCI). We summarize our experimental studies across the FRCs’ structural levels by using this integrated technique, including single-fiber tensile experiments, fiber/matrix debonding experiments, and single-edge notched bending experiments on composite laminates. It is revealed that the high-speed synchrotron X-ray PCI technique possesses sufficient spatial resolution to identify the failure behavior of a single fiber in the 10-μm scale level, as well as temporal resolution to identify the time sequence of internal dynamic damage evolution. The technique can penetrate through the opaque composite sample and provide real-time visualization of small-scale damaging mechanisms such as the embedded fiber’s sliding in the matrix and the fiber’s transverse debonding with the matrix. At an expanding scale, the technique can identify the crack initiation and track the cracking behavior inside a single ply or between different plies of a composite laminate. High-speed visualization inside the material by this integrated technique provides critical deformation and failure information to develop physical understanding of the damage inside composites under impact.

47 OTHER INSTRUMENTATION↗

Investigation of mechanism of anode plasma formation in ion diode with dielectric anode

The results of investigation of the anode plasma formation in a diode with a passive anode in magnetic insulation mode are presented. The experiments have been conducted using the BIPPAB-450 ion accelerator (350–400 kV, 6–8 kA, 80 ns) with a focusing conical diode with B{sub r} external magnetic field (a barrel diode). For analysis of plasma formation at the anode and the distribution of the ions beam energy density, infrared imaging diagnostics (spatial resolution of 1–2 mm) is used. For analysis of the ion beam composition, time-of-flight diagnostics (temporal resolution of 1 ns) were used. Our studies have shown that when the magnetic induction in the A-C gap is much larger than the critical value, the ion beam energy density is close to the one-dimensional Child-Langmuir limit on the entire working surface of the diode. Formation of anode plasma takes place only by the flashover of the dielectric anode surface. In this mode, the ion beam consists primarily of singly ionized carbon ions, and the delay of the start of formation of the anode plasma is 10–15 ns. By reducing the magnetic induction in the A-C gap to a value close to the critical one, the ion beam energy density is 3–6 times higher than that calculated by the one-dimensional Child-Langmuir limit, but the energy density of the ion beam is non-uniform in cross-section. In this mode, the anode plasma formation occurs due to ionization of the anode material with accelerated electrons. In this mode, also, the delay in the start of the formation of the anode plasma is much smaller and the degree of ionization of carbon ions is higher. In all modes occurred effective suppression of the electronic component of the total current, and the diode impedance was 20–30 times higher than the values calculated for the mode without magnetic insulation of the electrons. The divergence of the ion beam was 4.5°–6°.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geostationary Spectrograph (GeoSpec) for Earth and Atmospheric Science Applications

GeoSpec will support several possible future mission concepts in the Atmospheric Sciences and in Land and Ocean Sciences by measurement of both chemically linked atmospheric trace gas concentrations and profiles of important molecules such as OS, N02, CH20 and SO2 and at the same time coastal and ocean pollution events, tidal effects, and the origin and evolution of aerosol plumes. The instrument design concept we will describe is a dual spectrograph covering the WMS wavelength region of 310- 481 nm and the VIS/NIR wavelength region of 500-900 nm. A third channel in the short- wave infrared (SWIR) region between 2.2 p and 2.4 pn for total column measurements of CO, CH4, and N20 will also be described. The goal is to design a system capable of making moderate spatial resolution (750 meters at nadir) hyperspectral measurements (0.2 to 1.2 nm resolution) from a geostationary orbit. This would enable studies of time- varying pollution and coastal change processes with a temporal resolution of 5 minutes on a regional scale to 1 hour on a continental scale. Technological advances in the design and fabrication of convex holographic gratings and large format, high dynamic range PIN/CMOS detectors at the focal plane will be exploited. By simply changing the focal length of the front-end telescope GeoSpec can accommodate different orbital altitudes, including low Earth orbit, the Sun-side Lagrangian point L1, and/or different spatial resolutions.

Janz, Scott J.↗

Resolution Enhancement of MODIS-Derived Water Indices for Studying Persistent Flooding

Monitoring coastal marshes for persistent flooding and salinity stress is a high priority issue in Louisiana. Remote sensing can identify environmental variables that can be indicators of marsh habitat conditions, and offer timely and relatively accurate information for aiding wetland vegetation management. Monitoring activity accuracy is often limited by mixed pixels which occur when areas represented by the pixel encompasses more than one cover type. Mixtures of marsh grasses and open water in 250m Moderate Resolution Imaging Spectroradiometer (MODIS) data can impede flood area estimation. Flood mapping of such mixtures requires finer spatial resolution data to better represent the cover type composition within 250m MODIS pixel. Fusion of MODIS and Landsat can improve both spectral and temporal resolution of time series products to resolve rapid changes from forcing mechanisms like hurricane winds and storm surge. For this study, using a method for estimating sub-pixel values from a MODIS time series of a Normalized Difference Water Index (NDWI), using temporal weighting, was implemented to map persistent flooding in Louisiana coastal marshes. Ordinarily NDWI computed from daily 250m MODIS pixels represents a mixture of fragmented marshes and water. Here, sub-pixel NDWI values were derived for MODIS data using Landsat 30-m data. Each MODIS pixel was disaggregated into a mixture of the eight cover types according to the classified image pixels falling inside the MODIS pixel. The Landsat pixel means for each cover type inside a MODIS pixel were computed for the Landsat data preceding the MODIS image in time and for the Landsat data succeeding the MODIS image. The Landsat data were then weighted exponentially according to closeness in date to the MODIS data. The reconstructed MODIS data were produced by summing the product of fractional cover type with estimated NDWI values within each cover type. A new daily time series was produced using both the reconstructed 250-m MODIS, with enhanced features, and the approximated daily 30-m high-resolution image based on Landsat data. The algorithm was developed and tested over the Calcasieu-Sabine Basin, which was heavily inundated by storm surge from Hurricane Ike to study the extent and duration of flooding following the storm. Time series for 2000-2009, covering flooding events by Hurricane Rita in 2005 and Hurricane Ike in 2008, were derived. High resolution images were formed for all days in 2008 between the first cloud free Landsat scene and the last cloud-free Landsat scene. To refine and validate flooding maps, each time series was compared to Louisiana Coastwide Reference Monitoring System (CRMS) station water levels adjusted to marsh to optimize thresholds for MODIS-derived time series of NDWI. Seasonal fluctuations were adjusted by subtracting ten year average NDWI for marshes, excluding the hurricane events. Results from different NDWI indices and a combination of indices were compared. Flooding persistence that was mapped with higher-resolution data showed some improvement over the original MODIS time series estimates. The advantage of this novel technique is that improved mapping of extent and duration of inundation can be provided.

Underwood, L. W.↗

Transcript, protein and metabolite temporal dynamics in the CAM plant Agave

Already a proven mechanism for drought resilience, crassulacean acid metabolism (CAM) is a specialized type of photosynthesis that maximizes water-use efficiency (WUE) via an inverse (compared to C 3 and C 4 photosynthesis-performing species) day/night pattern of stomatal closure/opening to shift CO 2 uptake to the night, when evapotranspiration rates are low. A systems-level understanding of temporal molecular and metabolic controls is needed to define the cellular behavior that underpins CAM. Here, we report high-resolution temporal behaviors of transcript, protein and metabolite abundances across a CAM diel cycle and, where applicable, compare those observations to the well-established C 3 model plant, Arabidopsis thaliana. A mechanistic finding that emerged is that CAM operates with a diel redox poise that is shifted relative to that in Arabidopsis thaliana. Moreover, we identified widespread rescheduled expression of genes associated with signal transduction mechanisms that regulate stomatal opening/closing. Controlled production and degradation of transcripts and proteins represents a timing mechanism by which to regulate cellular function, yet how this molecular timekeeping regulates CAM physiology remains unclear. In this paper, we provide new insights into complex post-transcriptional and -translational hierarchies that govern CAM in Agave. These data sets together provide a resource to inform efforts to engineer more water-use efficient CAM pathway traits into economically valuable C 3 crops.

59 BASIC BIOLOGICAL SCIENCES↗

Pushing resolution in frequency and time: general discussion

One of the most important aspects of spectroscopy in general is resolution: the higher it is, the more information can be attained. At one end, spectral resolution provides geometric and electronic structural information and insights into weak interactions such as hydrogen bonds. At the other end, temporal resolution provides insight into geometric and electronic structural dynamics. The aim of this session is to provide a forum to discuss the state of the art in terms of resolution in general and how recent advances in light sources and ion mass spectroscopy can be used to study unexplored phenomena and interactions. Theoretical developments also have a key role in this area, particularly in relation to time-resolved measurements, since theoretical predictions are of key importance for providing molecular-insight into the observed experimental dynamics. The key discussion points will revolve around how experiment and theory can best combine to achieve the deepest insight, both in terms of structure and dynamics; and how new light sources may open new horizons.

Simons, Jack↗

Un-collimated single-photon imaging system for high-sensitivity small animal and plant imaging

In preclinical single-photon emission computed tomography (SPECT) system development the primary objective has been to improve spatial resolution by using novel parallel-hole or multi-pinhole collimator geometries. Furthermore, such high-resolution systems have relatively poor sensitivity (typically 0.01% to 0.1%). In contrast, a system that does not use collimators can achieve very high-sensitivity. Here we present a high-sensitivity un-collimated detector single-photon imaging (UCD-SPI) system for the imaging of both small animals and plants. This scanner consists of two thin, closely spaced, pixelated scintillator detectors that use NaI(Tl), CsI(Na), or BGO. The performance of the system has been characterized by measuring sensitivity, spatial resolution, linearity, detection limits, and uniformity. With 99m Tc (140 keV) at the center of the field of view (20 mm scintillator separation), the sensitivity was measured to be 31.8% using the NaI(Tl) detectors and 40.2% with CsI(Na). The best spatial resolution (FWHM when the image formed as the geometric mean of the two detector heads, 20 mm scintillator separation) was 19.0 mm for NaI(Tl) and 11.9 mm for CsI(Na) at 140 keV, and 19.5 mm for BGO at 1116 keV, which is somewhat degraded compared to the cm-scale resolution obtained with only one detector head and a close source. The quantitative accuracy of the system’s linearity is better than 2% with detection down to activity levels of 100 nCi. Two in vivo animal studies (a renal scan using 99m Tc MAG-3 and a thyroid scan with 123 I) and one plant study (a 99m TcO 4 - xylem transport study) highlight the unique capabilities of this UCD-SPI system. From the renal scan, we observe approximately a one thousand-fold increase in sensitivity compared to the Siemens Inveon SPECT/CT scanner. In conclusion, UCD-SPI is useful for many imaging tasks that do not require excellent spatial resolution, such as high-throughput screening applications, simple radiotracer uptake studies in tumor xenografts, dynamic studies where very good temporal resolution is critical, or in planta imaging of radioisotopes at low concentrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep convolutional neural networks for multi-scale time-series classification and application to disruption prediction in fusion devices

The multi-scale, mutli-physics nature of fusion plasmas makes predicting plasma events challenging. Recent advances in deep convolutional neural network architectures (CNN) utilizing dilated convolutions enable accurate predictions on sequences which have long-range, multi-scale characteristics, such as the time-series generated by diagnostic instruments observing fusion plasmas. Here we apply this neural network architecture to the popular problem of disruption prediction in fusion tokamaks, utilizing raw data from a single diagnostic, the Electron Cyclotron Emission imaging (ECEi) diagnostic from the DIII-D tokamak. ECEi measures a fundamental plasma quantity (electron temperature) with high temporal resolution over the entire plasma discharge, making it sensitive to a number of potential pre-disruptions markers with different temporal and spatial scales. Promising, initial disruption prediction results are obtained training a deep CNN with large receptive field ({$\sim$}30k), achieving an $F_1$-score of {$\sim$}91\% on individual time-slices using only the ECEi data.

convolutional neural networks↗

Sensor-based phenology from snowmelt experiment gradient, East River, Colorado, 2017 to 2020

The timing of snowmelt is a critical cue for the initiation of growth in mountain meadow ecosystems and can also impact the duration and magnitude of plant production. High frequency observations of species-level phenology are time consuming and require a high degree of expertise, and publicly available remote sensing products lack the necessary temporal resolution to assess fine-scale growing season dynamics. Near-surface sensing methods provide a middle ground with high temporal frequency and tractable spatial scales (from sub-meter to hillslope scale). This data package includes csv files of Normalized Difference Vegetation Index (NDVI) timeseries (SM_NDVI_dailymax.csv) and phenological thresholds (SM_NDVI_summary.csv) for sub-plots (1m2) and Green Chromatic Coordinate (GCC) phenological thresholds (SM_GCC_summary.csv) at the plot scale (10m x 14m). Location IDs associated with this data package are: ER-LM, WG-UM, WG-LS, ER-US, and XX-AL. Related data packages include: “Microclimate observations associated with snowmelt experiment gradient sites, East River, Colorado, 2017 to 2020” and “Colorado Elevation Gradient Snowmelt Manipulation Plant Phenology 2017-2018”.

54 ENVIRONMENTAL SCIENCES↗

Generation of Bright Soft X-ray Laser Beams (Final Report)

The project goal was to demonstrate new compact soft x-ray lasers emitting high energy ultrashort pulses at shorter wavelengths and increased repetition rates by amplification in atomic transitions in high density laser-created plasmas. To demonstrate these lasers we developed new high power solid state lasers. The project succeeded in demonstrating the shortest wavelength compact soft x-ray laser to date, 6.85 nm wavelength, and the highest repetition rate table-top soft x-ray laser, 400 Hz. We also applied these compact soft x-ray laser sources to determine the composition of materials with nanoscale resolution using a new technique that combines soft x-ray laser ablation with mass spectrometry, and we demonstrated that these lasers are capable of acquiring nanoscale resolution holograms with picosecond time resolution. The combination of an increased pumping efficiency with increased repetition rates can yield soft x-ray laser beams with an unprecedented average power on a table-top for applications demanding a high photon flux. We have demonstrated that the efficiency of plasma-based laser-pumped soft x-ray lasers can be significantly increased by detailed pulse shaping of the pump laser using a new pulse synthesizer. Results include the demonstration of 18.9 nm wavelength laser operation at a record 400 Hz repetition rate, and the extension of repetitive gain-saturated plasma-based table-top x-ray lasers to the shortest wavelength to date, 6.85 nm. Laser amplification was also observed at wavelengths as short at 5.8 nm by isolectronic scaling in Ni-like lanthanide ions. We have also conducted simulations to explore the possibility of demonstrating gain saturated atomic x-ray lasers near the carbon K-edge, in the “carbon window” for the first time. The work conducted under this program also includes the use of compact soft x-ray lasers in applications to problems of chemical interest, such as isotopic composition mapping of micron-size uranium particles with nanoscale resolution, and nanoscale resolution depth profiling analysis of CoNCN-coated electrodes for water oxidation catalysis. We also demonstrated single-shot high resolution soft x-ray Fourier transform holography over a broad 7 µm diameter field of view with ~ 5 ps temporal resolution.

74 ATOMIC AND MOLECULAR PHYSICS↗

The benefits of using short-interval satellite images to derive winds for tropical cyclones

During the 1975, 1976 and 1977 North Atlantic hurricane seasons, NOAA/NESS and NASA/GSFC conducted a cooperative program to determine the best resolution and frequency now available from satellite images for deriving winds to study and forecast tropical cyclones. High spatial and temporal resolution satellite imagery made it feasible to provide a large number of lower and upper tropospheric winds which can be obtained by tracking clouds within 650 km of tropical cyclone centers. Up to 10 (5) times as many low-level winds were derived from images spaced at 3 or 7.5 min intervals as from those at 30 min (15 min) intervals. Rapid-scan full-resolution IR and visible images minimized the 'erroneous' winds derived by tracking cloud elements that propagate by growing on one side and dissipating on the other and by tracking repetitive patterns that provided ambiguous indications of direction of movement.

Rodgers, E.↗