Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Tomography Analysis of Orion Artemis 1 Heatshield Sample

The Orion spacecraft, under NASA's Artemis program, is an integral step in humanity's ambitions of deep space exploration, including our return to the Moon and subsequent mission to Mars. The performance of Orion's heatshield is central to ensuring the safety and success of such missions. This presentation offers a comprehensive overview of the process used in and findings derived from tomography scans of an Artemis 1 heatshield sample executed at the Lawrence Berkeley National Laboratory's Advanced Light Source. These tomography scans captured high-resolution X-Ray images of the heatshield's microstructure, allowing advanced imaging to be employed for 3D image segmentation and visualization of the sample. The Porous Media Analysis (PuMA) software stands central to our analysis, offering robust computational algorithms and methodologies to digitally compute properties of the heatshield material. The presentation discusses the following derived metrics: - Volume fractions, representing the spatial distribution and amounts of various components throughout the heatshield’s depth. - Porosity and crack distributions, offering insights into the void space within the material, critical for understanding the heatshield's structural integrity. - Fiber orientation, detailing the alignment and arrangement of fibers, significant for material orthotropy. - Permeability estimates, quantifying the passage of gas through the material, relevant for re-entry conditions and pyrolysis gasses. One distinctive feature of this study is the comparative evaluation against data obtained from tomography scans of the Exploration Flight Test-1 (EFT-1) heatshield. Such a comparison offers multiple insights, including evaluation of the consistency and repeatability of manufacturing processes as well as understanding of any evolutionary changes in heatshield design or material properties.

Micro-tomography↗

Li-ion Battery Material phase prediction through Hierarchical Curriculum Learning

Li-ion Batteries (LIB), one of the most efficient energy storage devices, are widely adopted in many industrial applications. Imaging data of these battery electrodes obtained from X-ray tomography can explain the distribution of material constituents and allow reconstructions to study electron transport pathways. Therefore, it can eventually help quantify various associated properties of electrodes (e.g., volume-specific surface area, porosity) which determine the performance of batteries. However, these images often suffer from low image contrast between multiple material constituents , making it difficult for humans to distinguish and characterize these constituents through visualization. A minor error in detecting distributions among the material constituents can lead to a high error in the calculated parameters of material properties.We present a novel hierarchical curriculum learning framework to address the complex task of estimating material constituent distribution in battery electrodes. To provide spatially smooth prediction, our framework comprises three modules: (i) an uncertainty-aware model trained to yield inferences conditioned upon global knowledge of material distribution, (ii) a technique to capture relatively more fine-grained (local) distributional signals, (iii) an aggregator to appropriately fuse the local and global effects towards obtaining the final distribution.

Tabassum, Anika↗

Imaging of 3D morphological evolution of nanoporous silicon anode in lithium ion battery by X-ray nano-tomography

Nanostructured silicon with its high theoretical capacity and ability to accommodate volume expansion has attracted great attention as a promising anode material for Lithium ion (Li-ion) batteries. Liquid metal dealloying method, is a novel method to create nanoporous silicon (np-Si). The assembled Li-ion batteries based on such np- Si anode can be cycled beyond 1500 cycles, in 1000 mA h/g constant capacity cycling mode with consistent performance; however, it suffers from degradation after ~ 460 cycles, while being cycled under 2000 mA h/g. To reveal the failure mechanism and differences in the morphological evolution in different capacity cycling modes in the np-Si anode, we conducted synchrotron X-ray nano-tomography studies. The three dimensional (3D) morphological evolution was visualized and quantified as a function of the number of cycles and cycling capacities. By comparing the 3D morphology under each cycling condition and correlating these 3D morphological changes with cycling-life performance, we elucidate the failure mechanism of the np-Si electrodes resulting from a mesoscopic to macroscopic deformation, involving volume expansion and gradual delamination. In particular, the shorter cycling life in higher-capacity cycling mode stems from particle agglomeration. Overall, while the nanoporous structure can accommodate the volume expansion locally, these mesoscopic and macroscopic deformations ultimately result in heterogeneous stress distribution with faster delamination. As a result, the work thus sheds the light on the importance to consider the structural evolution at the mesoscopic and macroscopic scales, while designing nano-structured energy storage materials for enhanced performances, particularly for long cycling-life durability.

25 ENERGY STORAGE↗

Space Station Human Factors Research Review. Volume 1: EVA Research and Development

An overview is presented of extravehicular activity (EVA) research and development activities at Ames. The majority of the program was devoted to presentations by the three contractors working in parallel on the EVA System Phase A Study, focusing on Implications for Man-Systems Design. Overhead visuals are included for a mission results summary, space station EVA requirements and interface accommodations summary, human productivity study cross-task coordination, and advanced EVAS Phase A study implications for man-systems design. Articles are also included on subsea approach to work systems development and advanced EVA system design requirements.

Cohen, Marc M.↗

X-ray Phase Contrast Imaging of the Impact of a Single HMX Particle in a Polymeric Matrix

A thorough understanding of the mechanisms by which high explosives (HEs) are shock initiated, especially at the particle scale, is still in demand. One approach to explain shock initiation phenomenon is hot spot theory, which suggests that distributed energy in energetic material is localized due to shock or impact to generate the high temperatures for ignition. Here, we focus on the impact response of a HE polycrystalline particle, specifically HMX, in a polymer matrix. This represents a simplified analog of a traditional polymer-bonded explosive (PBX) formulation. A light gas gun, together with high-speed x-ray phase contrast imaging (PCI), was used to study the impact response of a single particle of production-grade HMX in a Sylgard-184® matrix. The high-speed x-ray PCI allows for real-time visualization of HE particle behavior. The experiments revealed that, at impact velocities of ~ 200 m s -1 , the energetic particle was cracked and crushed. When the impact velocity was increased to 445 m s -1 , a significant volume expansion of the particle was observed. This volume expansion is considered to be the result of chemical reaction within the HE particle.

42 ENGINEERING↗

The application of cinematic rendering to CT evaluation of upper tract urothelial tumors: principles and practice

Upper tract urothelial carcinoma (UTUC) is a relatively uncommon but aggressive genitourinary malignancy for which multi-phase contrast-enhanced computed tomography (CT) plays an important role in evaluation and staging. 3D imaging with maximum intensity projection (MIP) and volume-rendered (VR) images has been described as a useful means of evaluating UTUC. In this study, we describe the technique of a novel 3D methodology known as cinematic rendering (CR) and provide clinical examples of UTUC visualized with CR. CR utilizes a complex universal lighting model in order to create photorealistic images with improved detail and depth in comparison to MIP or VR images. In the case of UTUC, CR can be used in different contrast phases to show abnormally thickened and enhancing urothelium or filling defects in the renal collecting system or ureters in the excretory phase. CR images can also be manipulated in order to generate translucent views of the upper urinary tract in order to add conspicuity to intraluminal findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure

Aim: The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF). Methods: Fifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting {sup 99m}Tc-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and {sup 18}F-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually. Results: There was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT. Conclusion: CZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coupling dynamic in situ X-ray micro-imaging and indentation: A novel approach to evaluate micromechanics applied to oil shale

Oil and gas shales are a system where understanding the mechanical properties at the microscale is of paramount importance, e.g. to better understand the behavior of proppant-shale contacts and their role in the evolution of propped fractures in unconventional reservoirs. Here we show for the first time an experiment coupling indentation testing with in situ X-ray imaging in a Green River shale sample. A full compliance curve has been measured with the sample in water, allowing to visualize the indentation of the sample in function of axial load, in a purpose-built system for combined in situ indentation and X-ray imaging. A series of 3D datasets were used for a digital volume correlation study to obtain local strain fields. This analysis has been complemented with the analysis of cracks. Finally, geomechanical modeling has been carried out to replicate and generalize the observed behavior in the shale. This study validated this experimental approach, providing a breakthrough in understanding micro-mechanics in shales, and demonstrates how this class of experiments can be important for studies involving the prediction of the evolution of propped fractures in shale reservoirs, with possible applications in a much larger number of application fields (geothermal, materials science, etc.)

04 OIL SHALES AND TAR SANDS↗

Influence of Entrainment on Centimeter-Scale Cloud Microphysics in Marine Stratocumulus Clouds Observed during CSET

Abstract Cloud microphysical relationships observed during the Cloud System Evolution in the Trades (CSET) campaign held between Northern California and Hawaii were analyzed to study the effects of entrainment and subsequent mixing of free-tropospheric and cloudy air on cloud microphysical properties of marine stratocumulus clouds. The data measured by Holographic Detector for Clouds (HOLODEC) were extensively used because they could provide the 3D positions and sizes of droplets within sample volume on the centimeter scale, making it possible to explore the 3D spatial distribution of droplets, which has not been possible for conventional cloud probes. This study focused on analyzing the 3D spatial distribution of droplets and visual traits of inhomogeneous mixing and on quantifying the relationship between 3D spatial distributions and traits of inhomogeneous mixing. Two types of spatial distributions are compared. The first is measured droplet spatial distribution and the second type is generated randomly distributed droplets using the Monte Carlo approach, that is, to analyze whether or not clustering is strong enough to classify as a clustered distribution for a hologram. The difference between the two types of spatial distributions depends on whether they are affected by entrainment and mixing. The holograms observed near the cloud top, where the effects of entrainment and mixing would be immediate, showed relatively high confidence in the significance test for spatially clustered populations of droplets. Moreover, spatially clustered holograms appeared to exhibit stronger visual traits of inhomogeneous mixing than perfectly randomly distributed holograms only when observed near the cloud top. On the other hand, these characteristics did not appear for holograms observed deeper into the cloud where the effects of entrainment and mixing would be reduced. Such 3D structural characteristics of droplet distributions seem to be consistent with vertical circulation mixing.

Meteorology & Atmospheric Sciences↗

Design and Testing of the Vortex Ring Facility

This document summarizes the efforts of building an experimental test facility to study the evolution of the cloud following a nuclear detonation above ground level and support the development of numerical models to describe it. The experimental facility allows nonintrusive flow visualization and measurements of buoyant vortex ring formation and evolution using background-oriented Schlieren and particle image velocimetry techniques. In addition, 3D unsteady computational fluid dynamics simulations using unsteady Reynolds-averaged Navier–Stokes and volume-of-fluid numerical methods were performed to support the experimental design as well as to provide insight about the formation and evolution of the vortex ring.

42 ENGINEERING↗

Image analysis of particle field by means of computed tomography

In order to visualize and investigate spray structures, computed tomography technique is applied to analyze droplet information. From the transmitted light intensity through the spray and/or the data of particle size distribution obtained from a Fraunhofer diffraction principle, the quantitative volume of spray droplet or local particle size was calculated and the reconstruction of spray structures was made. The background of computed tomography is described along with some experimental results of the structure of intermittent spray such as diesel spray.

Nakayama, Mitsushige↗

A resting bottom sodium cooled fast reactor

This follows ICAPP 2011 paper 11059 'Fast Reactor with a Cold Bottom Vessel', on sodium cooled reactor vessels in thermal gradient, resting on soil. Sodium is frozen on vessel bottom plate, temperature increasing to the top. The vault cover rests on the safety vessel, the core diagrid welded to a toric collector forms a slab, supported by skirts resting on the bottom plate. Intermediate exchangers and pumps, fixed on the cover, plunge on the collector. At the vessel top, a skirt hanging from the cover plunges into sodium, leaving a thin circular slit partially filled by sodium covered by argon, providing leak-tightness and allowing vessel dilatation, as well as a radial relative holding due to sodium inertia. No 'air conditioning' at 400 deg. C is needed as for hanging vessels, and this allows a large economy. The sodium volume below the slab contains isolating refractory elements, stopping a hypothetical corium flow. The small gas volume around the vessel limits any LOCA. The liner cooling system of the concrete safety vessel may contribute to reactor cooling. The cold resting bottom vessel, proposed by the author for many years, could avoid the complete visual inspection required for hanging vessels. However, a double vessel, containing support skirts, would allow introduction of inspecting devices. Stress limiting thermal gradient is obtained by filling secondary sodium in the intermediate space. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cameco Corporation's Approach to Legacy and Ongoing Waste Management Within the Fuel Services Division - 19124

Since 2011, a Fuel Services Division (FSD) employee has been dedicated to oversee divisional waste management with the goal of accelerating the recycle/disposal of accumulated legacy radioactive wastes stored at its Ontario operations in Blind River and Port Hope. The Blind River Refinery (BRR) and Port Hope Conversion Facility (PHCF) were previously owned by the federal Crown Corporation, Eldorado Nuclear, becoming part of Cameco in 1988 and Cameco Fuel Manufacturing (CFM), previously known as Zircatec Precision Industries, becoming part of Cameco in 2006. Accumulated legacy radioactive waste is stored at each of the facilities. This radioactive waste has accumulated from operations beginning in the 1930's in Port Hope and the 1980's in Blind River. Due to minimal commercially available outlets for the disposal and/or treatment of these wastes, the waste was managed onsite by storage in underutilized space in buildings, trailers and/or in the secured yard. This relatively low-cost practice meant that over decades, the inventory increased at an unsustainable rate until available space became a limiting factor. During this time, the labelling, inventory records, characterization details and other history of many of the waste materials was not maintained adequately. Due to the volume of waste that had accumulated, campaigns to address these deficiencies in information were not considered feasible, sustaining the issue of accumulation of low-level radioactive waste. Since 2011, FSD has completed annual campaigns to address the accumulated legacy waste, which has included processing of material for decontamination to meet the unrestricted release criteria under the Canadian Nuclear Substance and Radiation Devices Regulations (NSRDR), disposal of marginally contaminated wastes (<500 ppm uranium) at a permitted landfill in the United States, processing of contaminated materials to reduce the volume of low-level radioactive waste and disposal at a designated facility in Port Hope. In addition FSD has undertaken significant changes to radioactive waste management practices at each of the facilities. Multiple characterization techniques, including visual observation, review of process and other historical records, laboratory analysis and radiation scanning have been utilized in campaign planning to identify the scope and appropriate waste management technique(s) to reduce the inventory of stored material. This divisional waste management program has resulted in a significant change to how radioactive waste is generated, inventoried, characterized and managed within FSD and has increased the visibility within the leadership team of the opportunities and challenges of waste management, such as alignment with decommissioning planning, project planning and budgeting. The heightened awareness has led to better financial and physical resource planning to execute waste projects with a current projected elimination of the legacy waste within FSD by 2025. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Shuttle vehicle and mission simulation requirements report, volume 1

The requirements for the space shuttle vehicle and mission simulation are developed to analyze the systems, mission, operations, and interfaces. The requirements are developed according to the following subject areas: (1) mission envelope, (2) orbit flight dynamics, (3) shuttle vehicle systems, (4) external interfaces, (5) crew procedures, (6) crew station, (7) visual cues, and (8) aural cues. Line drawings and diagrams of the space shuttle are included to explain the various systems and components.

Burke, J. F.↗

Scalable Analysis Methods and In Situ Infrastructure for Extreme Scale Knowledge Discovery

High performance computers have for many years been on a trajectory that gives them extraordinary compute power with the addition of more and more compute cores. At the same time, other system parameters such as the amount of memory per core and bandwidth to storage have remained constant or have barely increased. This creates an imbalance in the computer, giving it the ability to compute a lot of data that it cannot reasonably save out due to time and storage constraints. While technologies have been invented to mitigate this problem (burst buffers, etc.), software has been adapting to employ in situ libraries which perform data analysis and visualization on simulation data while it is still resident in memory. This avoids the need to ever have to pay the costs of writing many terabytes of data files. Instead, in situ enables the creation of more concentrated data products such as statistics, plots, and data extracts, which are all far smaller than the full-sized volume data. With the increasing popularity of in situ, multiple in situ infrastructures have been created, each with its own mechanism for integrating with a simulation. To make it easier to instrument a simulation with multiple in situ infrastructures and include custom analysis algorithms, this project created the SENSEI framework.

97 MATHEMATICS AND COMPUTING↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryocrystallography

In the past we have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. From these images it was clear that a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. During these studies we used large volume crystals, which were clearly distinguished from the loop holding them. These large crystals, originally grown for neutron diffraction studies, were chosen deliberately to enhance the imaging. As an extension to this work, we used thermal imaging to study small crystals, held in a cryo- loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryo-cooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied .

Snell, Eddie H.↗

SDSS IV MaNGA: visual morphological and statistical characterization of the DR15 sample

ABSTRACT We present a detailed visual morphological classification for the 4614 MaNGA galaxies in SDSS Data Release 15, using image mosaics generated from a combination of r band (SDSS and deeper DESI Legacy Surveys) images and their digital post-processing. We distinguish 13 Hubble types and identify the presence of bars and bright tidal debris. After correcting the MaNGA sample for volume completeness, we calculate the morphological fractions, the bi-variate distribution of type and stellar mass M* – where we recognize a morphological transition ‘valley’ around S0a-Sa types – and the variations of the g − i colour and luminosity-weighted age over this distribution. We identified bars in 46.8 per cent of galaxies, present in all Hubble types later than S0. This fraction amounts to a factor ∼2 larger when compared with other works for samples in common. We detected 14 per cent of galaxies with tidal features, with the fraction changing with M* and morphology. For 355 galaxies, the classification was uncertain; they are visually faint, mostly of low/intermediate masses, low concentrations, and discy in nature. Our morphological classification agrees well with other works for samples in common, though some particular differences emerge, showing that our image procedures allow us to identify a wealth of added value information as compared to SDSS-based previous estimates. Based on our classification, we also propose an alternative criteria for the E–S0 separation, in the structural semimajor to semiminor axis versus bulge to total light ratio (b/a − B/T) and concentration versus semimajor to semiminor axis (C − b/a) space.

Vázquez-Mata, J. A. (ORCID:0000000186941204)↗

Hot Views on Cold Crystals: The Application of Thermal Imaging in Cryo-crystallography

In the past we have used thermal imaging techniques to visualize the cryocooling processes of macromolecular crystals. From these images it was clear that a cold wave progresses through a crystal starting at the face closest to the origin of the cold stream and ending at the point furthest away. During these studies we used large volume crystals, which were clearly distinguished from the loop holding them. These large crystals, originally grown for neutron diffraction studies, were chosen deliberately to enhance the imaging. As an extension to this work, we present used thermal imaging to study small crystals, held in a cryo-loop, in the presence of vitrified mother liquor. The different infrared transmission and reflectance properties of the crystal in comparison to the mother liquor surrounding it are thought to be the parameter that produces the contrast that makes the crystal visible. An application of this technology may be the determination of the exact location of small crystals in a cryo-loop. Data from initial tests in support of application development was recorded for lysozyme crystals and for bFGF/dna complex crystals, which were cryo-cooled and imaged in large loops, both with visible light and with infrared radiation. The crystals were clearly distinguished from the vitrified solution in the infrared spectrum, while in the case of the bFGF/dna complex the illumination had to be carefully manipulated to make the crystal visible in the visible spectrum. These results suggest that the thermal imaging may be more sensitive than visual imaging for automated location of small crystals. However, further work on small crystals robotically mounted at SSRL did not clearly visualize those crystals. The depth of field of the camera proved to be limiting and a different cooling geometry was used, compared to the previous, successful experiments. Analysis to exploit multiple images to improve depth of field and experimental work to understand cooling geometry effects is ongoing. These results will be presented along with advantages and disadvantages of the technique and a discussion of how it might be applied.

Snell, E. H.↗