Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Creation of High Resolution Terrain Models of Barringer Meteorite Crater (Meteor Crater) Using Photogrammetry and Terrestrial Laser Scanning Methods

Barringer Meteorite Crater or Meteor Crater, AZ, has been a site of high interest for lunar and Mars analog crater and terrain studies since the early days of the Apollo-Saturn program. It continues to be a site of exceptional interest to lunar, Mars, and other planetary crater and impact analog studies because of its relatively young age (est. 50 thousand years) and well-preserved structure. High resolution (2 meter to 1 decimeter) digital terrain models of Meteor Crater in whole or in part were created at NASA Stennis Space Center to support several lunar surface analog modeling activities using photogrammetric and ground based laser scanning techniques. The dataset created by this activity provides new and highly accurate 3D models of the inside slope of the crater as well as the downslope rock distribution of the western ejecta field. The data are presented to the science community for possible use in furthering studies of Meteor Crater and impact craters in general as well as its current near term lunar exploration use in providing a beneficial test model for lunar surface analog modeling and surface operation studies.

Brown, Richard B.↗

LiDAR-Inertial Based Navigation and Mapping for Precision Landing

Future lander missions will travel to ambitious, scientifically interesting locations near rough and dangerous terrain. They will need to operate with limited prior information about the terrain, and under varying lighting conditions. Landing safely and precisely in the face of these challenges is difficult for existing vision-based landing systems, which require detailed orbital reconnaissance, a priori hazard maps, and impose time-of-day restrictions on landing to ensure similar lighting conditions in orbital and descent imagery. Advanced 3D imaging LiDAR systems currently under development, and originally intended for single-scan hazard detection, have the potential to be operated continuously from altitudes of up to 5 km. Used together with existing inertial measurement units (IMUs), these sensors open a path-to-flight for a full navigation and mapping system, which could replace or augment a traditional landing sensor suite. A landing system based around these sensors can perform accurate altimetry, map-relative localization (MRL), LiDAR-inertial odometry, and map refinement in an illumination-insensitive manner, over unknown or partially known terrain. This paper outlines preliminary work on a LiDAR-inertial landing system that: estimates the spacecraft trajectory during entry, descent, and landing (EDL); and maps the topography of the terrain below, for future use in hazard detection and avoidance. An incremental, factor graph based, smoothing approach is used to solve for the maximum a posteriori trajectory of spacecraft states. Integrated IMU measurements and features tracked in adjacent range and intensity images are used to estimate motion (LiDAR-inertial odometry). LiDAR scans are binned into motion-corrected digital elevation models (DEMs), which are matched to an existing orbital topographic map to provide absolute position information (MRL). The estimated trajectory is then used to project the LiDAR scans into the map frame, creating a variable-resolution quadtree topographic map suitable for hazard detection and avoidance. Existing topographic maps from throughout the solar system (i.e., Earth, the Moon, Mars, Ceres, Vesta, Europa, Enceladus, and Eros) are upsampled for use in EDL simulations. The Mars 2020 Lander Vision System Simulator (LVSS) is extended to simulate LiDAR-inertial data for realistic EDL trajectories. Results of the algorithm operating on the simulated data are presented. Estimated spacecraft trajectory and refined map are compared to ground truth to assess estimation accuracy.

Katake, Anup↗

Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of surface modified Zr cladding by coating technology for ATF

It is expected that the accident tolerance fuels (ATF) will provide an enhanced fuel performance of active cooling in the reactor core for a longer time period during design-basis events as well as maintain or improve the fuel performance during normal operations and operational transients. Thus, various ATF cladding concepts have being suggested and developed in many countries. Among them, the coated cladding concept is studied in this work after the considerations of various performances in both the accidents and normal operation of LWRs. In the surface coated cladding concepts, the combination of coating material and coating method is a very important factor to determine the ATF cladding performance. As a new coating material, Cr-based alloy was developed to increase the corrosion resistance under normal operation as well as the oxidation resistance during an accident. From the high temperature oxidation test at 1200 Celsius degrees, the Cr-based alloy showed a superior oxidation resistance to Zircaloy-4 cladding, and showed more improved corrosion resistance than Zircaloy-4 cladding under 360 Celsius degrees PWR simulated loop conditions. The 3D laser coating and a combination of arc ion plating and laser beam scanning were developed to obtain a good adhesion property of corrosion resistance alloy coated on a Zr substrate. The corrosion resistance alloy (Cr-based alloy and FeCrAl alloy) coated layer used by two types of coating methods was maintained without peeling off during the ring compression test at room temperature, although some cracks were formed on the coated layer. After a high-temperature oxidation test at 1200 Celsius degrees for 2000 s, a very thin oxide layer, which was a few microns, was formed on the corrosion resistance alloy layer. However, the ZrO{sub 2} phase, which was thicker than 100 μm was formed on the Zr alloy cladding surface. Thus, it is known that the high-temperature oxidation resistance of commercial Zr alloy cladding can be considerably improved by the coating of corrosion resistant alloys. In addition, the partial oxide dispersion strengthened (ODS) treatment using a laser beam scanning (LBS) method was applied to decrease the ballooning and rupture opening during accident conditions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom

Purpose : X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosis and treatment is studied using a novel approach for three-dimensional (3D) x-ray fluorescence mapping (XFM) of gold nanoparticle (GNP)-loaded objects in a physical phantom at the technical level. Methods : All the theoretical analysis and experiments are conducted under the condition of using x-ray pencil beam and a compactly integrated x-ray spectrometer. The penetrability of the fluorescence x-rays from GNPs is first investigated by adopting a combination of BR12 with 70 mm/50 mm in thickness on the excitation/emission path to mimic the possible position of tumor goldin vivo. Then, a physical phantom made of BR12 is designed to translate in 3D space with three precise linear stages and subsequently the step by step XFM scanning is performed. The experimental technique named as background subtraction is applied to isolate the gold fluorescence from each spectrum obtained by the spectrometer. Afterwards, the attenuations of both the incident primary x-ray beam with energies beyond the gold K-edge energy (80.725 keV) and the isolated gold K{sub α} fluorescence x-rays (65.99 –69.80 keV) acquired after background subtraction are well calibrated, and finally the unattenuated K{sub α} fluorescence counts are used to realize mapping reconstruction and to describe the linear relationship between gold fluorescence counts and corresponding concentration of gold solutions. Results : The penetration results show that the goldK{sub α} fluorescence x-rays have sufficient penetrability for this phantom study, and the reconstructed mapping results indicate that both the spatial distribution and relative concentration of GNPs within the designed BR12 phantom can be well identified and quantified. Conclusions : Although the XFM method in this investigation is still studied at the technical level and is not yet practical for routinein vivo mapping tasks with GNPs, the current penetrability measurements and phantom study strongly suggest the feasibility to establish and develop a 3D XFM system.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Postoperative Radiotherapy in Prostate Cancer: The Case of the Missing Target

Purpose: Postoperative radiotherapy (XRT) increases survival in high-risk prostate cancer patients. Approximately 50% of patients on long-term follow-up relapse despite adjuvant XRT and the predominant site of failure remains local. Four consensus guidelines define postoperative clinical target volume (CTV) in prostate cancer. We explore the possibility that inadequate CTV coverage is an important cause of local failure. This study evaluates the utility of preoperative magnetic resonance imaging (MRI) in defining prostate bed CTV. Methods and Materials: Twenty prostate cancer patients treated with postoperative XRT who also had preoperative staging MRI were included. The four guidelines were applied and the CTVs were expanded to create planning target volumes (PTVs). Preoperative MRIs were fused with postoperative planning CT scans. MRI-based prostate and gross visible tumors were contoured. Three-dimensional (3D) conformal four- and six-field XRT plans were developed and dose-volume histograms analyzed. Subtraction analysis was conducted to assess the adequacy of prostate/gross tumor coverage. Results: Gross tumor was visible in 18 cases. In all 20 cases, the consensus CTVs did not fully cover the MRI-defined prostate. On average, 35% of the prostate volume and 32% of the gross tumor volume were missed using six-field 3D treatment plans. The entire MRI-defined gross tumor volume was completely covered in only two cases (six-field plans). The expanded PTVs did not cover the entire prostate bed in 50% of cases. Prostate base and mid-zones were the predominant site of inadequate coverage. Conclusions: Current postoperative CTV guidelines do not adequately cover the prostate bed and/or gross tumor based on preoperative MRI imaging. Additionally, expanded PTVs do not fully cover the prostate bed in 50% of cases. Inadequate CTV definition is likely a major contributing factor for the high risk of relapse despite adjuvant XRT. Preoperative imaging may lead to more accurate CTV definition, which should result in further improvements in survival for patients with high-risk prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large-scale synthesis of hierarchical-structured weissite (Cu{sub 2−x}Te) flake arrays and their catalytic properties

Graphical abstract: - Highlights: • Large-scale Cu{sub 2−x}Te flake arrays grown on copper foam were synthesized. • They possess superior catalytic efficiency on methylene blue with the assistance of H{sub 2}O{sub 2}. • The effects of preparing conditions on the growth of Cu{sub 2−x}Te flake arrays were investigated. - Abstract: Large-scale weissite (Cu{sub 2−x}Te) flake arrays with three-dimensional (3D) hierarchical structure have been successfully fabricated via a facile one-step solution-phase strategy through the reaction of tellurium powder and copper foam. At the end of the reaction Cu{sub 2−x}Te flakes were distributed evenly on the surface of a porous solid copper substrate. Field-emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM) analysis showed the abundance of flakes grown on the 3D porous copper architecture, while X-ray diffraction (XRD) and energy-dispersive X-ray spectra (EDS) were used to determine the crystal structure and phase composition of these products. A series of experiments discovered that the size and morphology of the products could be affected by some reactive parameters including the reaction time, synthesis temperature and volume ratio of absolute ethanol/deionized water. Catalysis experiments using the in situ synthesized of Cu{sub 2−x}Te flakes to catalyze the degradation of methylene blue (MB) demonstrated the strong catalytic ability of these flakes.

36 MATERIALS SCIENCE↗

Precision islands in the Ising and O(N ) models

We make precise determinations of the leading scaling dimensions and operator product expansion (OPE) coefficients in the 3d Ising, O(2), and O(3) models from the conformal bootstrap with mixed correlators. We improve on previous studies by scanning over possible relative values of the leading OPE coefficients, which incorporates the physical information that there is only a single operator at a given scaling dimension. The scaling dimensions and OPE coefficients obtained for the 3d Ising model, (Δ σ , Δ ϵ , λ σσϵ , λ ϵϵϵ ) = (0.5181489(10), 1.412625(10), 1.0518537(41), 1.532435(19) , give the most precise determinations of these quantities to date.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

H-Canyon exhaust tunnel LiDAR data request for information review and release

This request is to release LiDAR data files acquired by SRNL R&D Engineering and H-Area Operations and Engineering while performing scans of the interior of the H-Canyon Exhaust tunnel. LiDAR data includes 3-dimensional (3D) point cloud data sets and panoramic digital images of the interior tunnel wall surfaces. Presently two deployments have been completed, the first in November 2019, Fig. 1, and the second in June of 2020. This request is for the release of the data collected during those two deployments. Detailed information on the deployment and data collected can be found in SRS document C-ESR-H-00072, “November 2019 Initial Deployment of LiDAR”. It is planned to perform ongoing scans at approximately 6-month intervals, the purpose of the deployments is to evaluate the usefulness of the data collected to enable quantitative measurements such as tunnel dimensions and rate of surface erosion and as a precursor to a potential deployment of a LiDAR system on the tunnel inspection crawler.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Designing Track for Electrospinning Unit and Cost-Effective Laser Scanning System

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo↗

Designing a track for an electrospinning unit and cost-effective laser scanning system

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo↗

Microstructure characterization and mechanical behaviors of a hot forged high Nb containing PM-TiAl alloy

In this work, the effects of deformation on the microstructure and mechanical behaviors of TiAl alloy were investigated. Deformed microstructure observation was characterized by scanning electron microscopy, electron back scattered diffraction technique, transmission electron microscopy and DEFORM-3D software. Results indicated that the core area of the TiAl pancake was characterized by completely dynamically recrystallized microstructures, however some residual lamellar colonies can be observed near the edge area, which are primarily caused by a temperature drop and inhomogenous plastic flow. The main softening mechanism is dynamic recrystallization of γ grains. The as-forged alloy exhibited excellent mechanical properties at both room temperature and high temperature. Tensile test results showed that the ultimate tensile strength of the alloy increased from 832 MPa at room temperature to 853 MPa at 700 °C, while the elongation increased from 2.7% to 17.8%. Even at the temperature of 850 °C, the ultimate tensile strength maintained 404 MPa, and the elongation increased to 75%. The as-forged alloy also exhibited remarkable low-temperature superplasticity at 850 °C, with an elongation of 120%. - Highlights: • The core area of the TiAl pancake was characterized by DRX microstructure. • The elongation at RT is higher than that of other high Nb-containing TiAl alloys. • The forged alloy exhibited low-temperature superplasticity at 850 °C.

36 MATERIALS SCIENCE↗

Robotic Assisted Non-Destructive Testing (NDT)

Mission Statement: Concrete wall characterization for structural integrity evaluation of H-Canyon exhaust tunnel using a remote controlled robotic arm with a NDT Concrete Instrument. Challenges: Rough and Curved Surfaces, Remote location. The UR5 is a collaborative robotic arm capable of: Payload: 11 lbs (5 kg), Reach: 33.5 in (850 mm), Footprint: 5.87 in (149 mm) diameter, Weight: 45.4 Ibs (20.6 kg). The force torque sensor reacts to a set value inputted by the user that can be utilized for sensitive products. This allows the UR5 to react to surfaces using the built-in function to search for a wall and orient itself normal to that plane. The Proceq Pundit 250 array is a nondestructive device that the user applies against a concrete wall and scans using ultrasonic transducers. The back wall and other defects can be show through the touchscreen. A fixture to hold the Proceq Pundit 250 array onto the UR5 robotic arm was designed and 3D printed. It includes openings for easy access to the buttons from the Pundit array as well as a reinforced structural design. The scan from the Pundit array can show the back-wall, rebars, and other defects to assist in determining the structural integrity. In order to scan, a program was made to search for the wall first. 1. The UR5 robotic arm will go to the desired location away from the wall. 2. It will then search for the wall by moving towards it slowly. 3. After contact, the force applied will slowly but steadily increase to a preset value inputted by the user. 4. The force torque sensor will use those values and communicate with the UR5 by adjusting the arm to become normal to the wall. 5. The arm will then apply force to push back the transducers on the Pundit array to avoid gaps. 6. It will then prompt the user to collect data and wait until finished. The UR5 teach pendant allows the user to program the robot to perform automated and repeatable tasks. It includes a free drive mode which allows the user to move the arm to a desired position by hand. The user can also apply restricted planes which include either stopped or slower motion to ensure safety. The concrete sample being tested includes rebars and different grades of surface roughness to understand the readings from the Proceq Pundit 250 array. Desired concrete samples are currently being fabricated that will simulate the terrain being tested.

3D PRINTING↗

Liquid crystalline phase synthesis of nanoporous MnO{sub 2} thin film arrays as an electrode material for electrochemical capacitors

Graphical abstract: Three-dimensional (3D) MnO{sub 2} thin film arrays with nanoporous structure is electrodeposited on Ti foil from hexagonal lyotropic liquid crystalline phase. Low-angle X-ray diffraction (XRD), wide-angle XRD, field emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM) are employed to study the morphology and the structure of the as-synthesized MnO{sub 2} materials. Galvanostatic charge/discharge measurements show the nanoporous, 3D electrode material exhibits excellent capacitive performance between the potential range of −0.1 to 0.9 V, and a maximum specific capacitance as high as 462 F g{sup −1} are achieved in 0.5 M Na{sub 2}SO{sub 4} solution at a charge/discharge current density of 4 A g{sup −1}. Highlights: ► 3D MnO{sub 2} thin film arrays with nanoporous structure is fabricated for the first time. ► A maximum specific capacitance as high as 462 F g{sup −1} is obtained. ► The 3D and nanoporous superarchitecture facilitate electrolyte penetration. -- Abstract: Three-dimensional (3D) MnO{sub 2} thin film arrays with nanoporous structure is electrodeposited on Ti foil from hexagonal lyotropic liquid crystalline phase. Low-angle X-ray diffraction (XRD), wide-angle XRD, field emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM) are employed to study the morphology and the structure of the as-synthesized MnO{sub 2} materials. Galvanostatic charge/discharge measurements show the nanoporous, 3D electrode material exhibits excellent capacitive performance between the potential range of −0.1 to 0.9 V, and a maximum specific capacitance as high as 462 F g{sup −1} are achieved in 0.5 M Na{sub 2}SO{sub 4} solution at a charge/discharge current density of 4 A g{sup −1}.

36 MATERIALS SCIENCE↗

Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer Radiotherapy

Purpose: To evaluate the accuracy of three-dimensional (3D) surface imaging system (AlignRT) registration algorithms for head-and-neck cancer patient setup during radiotherapy. Methods and Materials: Eleven patients, each undergoing six repeated weekly helical computed tomography (CT) scans during treatment course (total 77 CTs including planning CT), were included in the study. Patient surface images used in AlignRT registration were not captured by the 3D cameras; instead, they were derived from skin contours from these CTs, thereby eliminating issues with immobilization masks. The results from surface registrations in AlignRT based on CT skin contours were compared to those based on bony anatomy registrations in Pinnacle{sup 3}, which was considered the gold standard. Both rigid and nonrigid types of setup errors were analyzed, and the effect of tumor shrinkage was investigated. Results: The maximum registration errors in AlignRT were 0.2 Degree-Sign for rotations and 0.7 mm for translations in all directions. The rigid alignment accuracy in the head region when applied to actual patient data was 1.1 Degree-Sign , 0.8 Degree-Sign , and 2.2 Degree-Sign in rotation and 4.5, 2.7, and 2.4 mm in translation along the vertical, longitudinal, and lateral axes at 90% confidence level. The accuracy was affected by the patient's weight loss during treatment course, which was patient specific. Selectively choosing surface regions improved registration accuracy. The discrepancy for nonrigid registration was much larger at 1.9 Degree-Sign , 2.4 Degree-Sign , and 4.5 Degree-Sign and 10.1, 11.9, and 6.9 mm at 90% confidence level. Conclusions: The 3D surface imaging system is capable of detecting rigid setup errors with good accuracy for head-and-neck cancer. Further investigations are needed to improve the accuracy in detecting nonrigid setup errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure reconstruction of battery polymer separators by fusing 2D and 3D image data for transport property analysis

A new approach to generate high-fidelity 3D microstructure reconstructions by leveraging resolution and sample volume characteristics from 2D and 3D microscopy methods is presented here. This approach is employed to model the microstructure of a highly orthotropic polypropylene separator used in lithium-ion batteries, which have challenging multi-scale features of fibrils (<100 nm) and lamellae (>100 nm) to resolve in 3D. Phase contrast nano X-ray computed tomographic data are used to reconstruct the lamellae phase, while 2D scanning electron microscopy data are used to characterize sub-100 nm microstructure features such as the thin fibrils that are beyond the effective resolution of X-ray computed tomography. Fibril geometries are reconstructed stochastically based on the 2D higher resolution data, and integrated with the lamellae geometries in 3D space. Transport property analyses are performed to investigate the bias of microstructure models without considering the fibrils. A sensitivity study is also conducted to facilitate understanding of the relationship between microstructure characteristics and transport properties.

25 ENERGY STORAGE↗

Bootstrapping mixed correlators in three-dimensional cubic theories II

Conformal field theories (CFTs) with cubic global symmetry in 3D are relevant in a variety of condensed matter systems and have been studied extensively with the use of perturbative methods like the \varepsilon ε expansion. In an earlier work, we used the nonperturbative numerical conformal bootstrap to provide evidence for the existence of a previously unknown 3D CFT with cubic symmetry, dubbed “Platonic CFT”. In this work, we make further use of the numerical conformal bootstrap to perform a three-dimensional scan in the space of scaling dimensions of three low-lying operators. We find a three-dimensional isolated allowed region in parameter space, which includes both the 3D (decoupled) Ising model and the Platonic CFT. The essential assumptions on the spectrum of operators used to provide the isolated allowed region include the existence of a stress-energy tensor and the irrelevance of certain operators (in the renormalization group sense).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗