Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Numerical Experiments in Error Control for Sound Propagation Using a Damping Layer Boundary Treatment

This paper presents results from numerical experiments for controlling the error caused by a damping layer boundary treatment when simulating the propagation of an acoustic signal from a continuous pressure source. The computations are with the 2D Linearized Euler Equations (LEE) for both a uniform mean flow and a steady parallel jet. The numerical experiments are with algorithms that are third, fifth, seventh and ninth order accurate in space and time. The numerical domain is enclosed in a damping layer boundary treatment. The damping is implemented in a time accurate manner, with simple polynomial damping profiles of second, fourth, sixth and eighth power. At the outer boundaries of the damping layer the propagating solution is uniformly set to zero. The complete boundary treatment is remarkably simple and intrinsically independant from the dimension of the spatial domain. The reported results show the relative effect on the error from the boundary treatment by varying the damping layer width, damping profile power, damping amplitude, propagtion time, grid resolution and algorithm order. The issue that is being addressed is not the accuracy of the numerical solution when compared to a mathematical solution, but the effect of the complete boundary treatment on the numerical solution, and to what degree the error in the numerical solution from the complete boundary treatment can be controlled. We report maximum relative absolute errors from just the boundary treatment that range from O[10-2] to O[10-7].

Computational Aeroacoustics↗

Time dependence of solid-particle impingement erosion of an aluminum alloy

Erosion studies were conducted on 6061-T6511 aluminum alloy by using jet impingement of glass beads and crushed glass particles to investigate the influence of exposure time on volume loss rate at different pressures. The results indicate a direct relationship between erosion-versus-time curves and pitmorphology (width, depth, and width-depth ratio)-versus-time curves for both glass forms. Extensive erosion data from the literature were analyzed to find the variations of erosion-rate-versus-time curves with respect to the type of device, the size and shape of erodent particles, the abrasive charge, the impact velocity, etc. Analysis of the experimental data, obtained with two forms of glass, resulted in three types of erosion-rate-versus-time curves: (1) curves with incubation, acceleration, and steadystate periods (type 1); (2) curves with incubation, acceleration, decleration, and steady-state periods (type 3); and (3) curves with incubation, acceleration, peak rate, and deceleration periods (type 4). The type 4 curve is a less frequently seen curve and was not reported in the literature. Analysis of extensive literature data generally indicated three types of erosion-rate-versus-time curves. Two types (types 1 and 3) were observed in the present study; the third type involves incubation (and deposition), acceleration, and steady-state periods (type 2). Examination of the extensive literature data indicated that it is absolutely necessary to consider the corresponding stages or periods of erosion in correlating and characterizing erosion resistance of a wide spectrum of ductile materials.

Veerabhadrarao, P.↗

DEM Modeling and Validation of Pebble Bed Packing Using Chrono::GPU

Accurate prediction of pebble packing structure is important for pebble bed reactors because the spatial distribution of void fraction directly affects coolant flow, pressure drop, heat transfer, and neutronic behavior. However, experimentally validated DEM studies that directly evaluate local void-fraction structure in reactor-relevant pebble beds remain limited. In this work, the pebble bed experiment conducted at Missouri University of Science and Technology is simulated using the graphics processing unit (GPU)-based discrete element method (DEM) code Chrono::GPU. The study focuses on evaluating the ability of Chrono::GPU to reproduce the packing arrangement and void-fraction distribution of a randomly packed spherical pebble bed. The DEM results are first verified against established radial void-fraction correlations, including the Mueller and Vortmeyer-Schuster models, to assess the predicted bulk porosity, near-wall behavior, and oscillatory packing structure. The simulation is then verified against reference DEM data and validated against gamma-ray computed tomography (CT) experimental data at three axial locations. The Chrono::GPU results reproduce the main features of the experimental packing, including the high void fraction near the wall, the first near-wall trough, and the damped oscillatory radial profile caused by wall-induced ordering. Quantitative comparison with DEM data and the CT-based radial profiles shows good agreement, with mean absolute errors on the order of 0.07 and root-mean-square errors below 0.09 for the averaged profiles. These results demonstrate that Chrono::GPU can accurately capture the void-fraction structure of spherical pebble beds and provides a reliable DEM framework for future pebble bed reactor packing, recycling, and thermal-hydraulic studies.

97 - MATHEMATICS AND COMPUTING↗

Evaluating the impacts of Variable Message Signs on Airport Curbside Performance Using Microsimulation

Curbs play a vital role in facilitating vehicle access and egress for individuals at airports. Inefficiently allocating this resource hinders airport accessibility and productivity, resulting in congestion, longer travel times, and increased pollution. As airport demand fluctuates throughout the day and grows over time, airports face intensified curbside pressure. Yet, curb management research is significantly less robust at airports than in urban areas. Given the unbalanced nature of airport demand—riders tend to arrive simultaneously at specific entrances at certain hours—Variable Message Sign (VMS) arises as a cost-effective technology to divert vehicles from congested to underutilized curbs. Still, VMS implementation faces a significant challenge. Historically, airports have managed VMS heuristically and by intuition rather than an evidence-based approach. This research investigates the impacts of implementing VMS on curb performance at airports. By considering different driver compliance rates (DCR), we aim to determine when the sign should be turned on and off to diverge traffic to avoid undesired externalities while enhancing curb performance. Using a validated agent-based microsimulation model, VISSIM, we analyzed the Seattle-Tacoma (SeaTac) Airport as a case study. We modeled sixteen VMS management scenarios and a baseline where the message sign is not displayed, diverging vehicles between the departures and arrivals access levels at four different moments (early morning, morning, afternoon, and late night). We quantified the effects of VMS using seven metrics, including curb productivity index (CPI), curb accessibility (CA), queue length, queue duration, delay, vehicle counts, and emissions. The results of each scenario were compared against the baseline using absolute and relative changes and Repeated Measures ANOVA. Overall, VMS improved curb performance and traffic conditions at the airport, reducing emissions by 14.8% to 8.9%. Moreover, significant reductions in queue length (1,150 ft to 100 ft) and duration (15 to 144 minutes) were observed in the sending link under all VMS policies. However, impacts on the receiving link varied based on congestion, with significant increases in queue duration (9.8 to 24 min) when congested but no substantial changes in free flow. Notably, diverging vehicles to congested links resulted in non-significant results, and activating late and deactivating late VMS affected curb productivity (-5.8% to -61.4%), curb accessibility (-16.5% to -25.8%), cumulative counts (-33.4% to -59.4%), and vehicle delay (95.98% to 594.3%). Activating VMS before congestion begins in the sending link and deactivating before a queue forms in the receiving link yield the most significant improvements: 8.1% to 10.1% in CPI, 9.4% to9.6% in CA, -29.3% to -77.9% in total delay, -11.6% to -13.9% in total emissions, and 101% to 103% in cumulative counts. As the analysis was made with a wide range of time periods, access levels, driver compliance rates, and scenarios, we believe our findings can provide valuable insights into how airports should manage VMS. Our work introduces a novel approach to the scientific airport literature, as some of our metrics were previously unexplored. Additionally, we propose a methodology that other airports can adopt to maximize their curb performance.

Gutierrez, Jorge D.↗

Evaluation of Sex Differences in Physiologic Responses to Submaximal Cycling Under Normoxic and Hypoxic Conditions

BACKGROUND: During Lunar missions, astronauts may live and operate in conditions where altered atmospheric pressure and oxygen concentrations may result in a mildly hypoxic environment. While the compensatory hemodynamic mechanisms ensuring adequate oxygen delivery to contracting muscles during exercise in hypoxic conditions are well-studied, less research has focused on potential sex differences in the responses to hypoxia exposure during exercise. As female astronauts make up half of the Artemis astronaut corps, understanding whether physiologic responses in a hypoxic environment differ between sexes may inform recommendations for exercising safely in exploration environments. METHODS: Fourteen subjects (7M/7F) from NASA’s Exploration Atmosphere Study performed two submaximal cycle exercise trials (10 min of exercise at 40% peak aerobic capacity [VO 2 pk]) ergometer under normobaric normoxic gas (21% O 2 ) and normobaric hypoxic (18% O 2 and balanced N 2 ) conditions in randomized order. Linear mixed models with Bonferroni post hoc corrections (fixed effects: condition, sex, VO 2 pk [covariate], body mass [BM, covariate]; random effects: subject, mission) were performed to evaluate the effect of condition and sex on physiologic responses to exercise (oxygen uptake [VO 2 ], carbon dioxide production [VCO 2 ], ventilation [VE], oxygen saturation [SpO 2 ], and heart rate [HR]). RESULTS: Males were comparable to females for age (36.6±4.7 vs 36.4±9.3 yrs; p>0.05) but had greater BM (87.3±10.9 vs 64.5±7.4 kg; p<0.001) and absolute VO2pk (3.5±0.6 vs 2.4±4.7 L/min; p<0.001). Additionally, males had higher VO2 (p=0.005), VCO2 (p=0.02), and VE (p=0.01) during exercise trials, independent of condition; however, when VO 2 pk was added as a covariate, the effect of sex was no longer significant. SpO 2 was reduced during hypoxic exercise compared to the normoxic condition (p<0.001), but neither sex nor environmental condition impacted HR. CONCLUSIONS: Though most physiologic responses to submaximal, short-duration exercise between normoxia and mild hypoxia were similar, females exhibited lower VO 2 , VCO 2 , and VE during both conditions, likely driven by lower aerobic capacity. Future research is needed to determine whether similar findings result from multiday hypobaric hypoxia experienced during missions.

N C Strock↗

Updates of the KArLE Experiment: New Libs Calibration Under High Vacuum for the Quantification of Potassium in Basalt for In Situ Geochronology

In planetary exploration, in situ absolute geochronology is one of the main important measurements that needs to be accomplished. Until now, on Mars, the age of the surface is only determined by crater density counting, which gives relative ages. These ages can have a lot of uncertainty as they depend on many parameters. More than that, the curves must be ties to absolute ages. Thus far, only the lost lander Beagle 2 was designed to conduct absolute geochronology measurements, though some recent attempts using MSL Curiosity show that this investigation is feasible and should be strongly encouraged for future flight. Experimental: The Potassium (K)-Argon Laser Experiment (KArLE) is being developed at MSFC through the NASA Planetary Instrument Definition and Development Program (PIDDP). The goal of this experiment is to provide in situ geochronology based on the K-Ar method. A laser ablates a rock under high vacuum, creating a plasma which is sensed by an optical spectrometer to do Laser Induced Breakdown Spectroscopy (LIBS). The ablated material frees gases, including radiogenic 40Ar,which is measured by a mass spectrometer (MS). As the potassium is a content and the 40Ar is a quantity, the ablated mass needed in order to relate them. The mass is given by the product of the ablated volume by the density of this material. So we determine the mineralogy of the ablated material with the LIBS spectra and images and calculate its density. The volume of the pit is measured by using microscopy. LIBS measurement of K under high vacuum: Three independant projects [1, 2, 3] including KArLE, are developing geochronological instruments based on this LA-LIBS-MS method. Despite several differences in their setup, all of them have validated the methods with analyses and ages. However, they all described difficulties with the LIBS measurements of K [3,4]. At ambient pressure, the quantification of K by LIBS on geological materials can be accurate [5]. However the protocol of the LA-LIBS-MS experiment required hundreds of shots under high vacuum in order to free enough 40Ar* to be measured by the QMS. This long duration of ablation may induces significant changes in the LIBS spectra. The pressure may increases by orders of magnitudewithin the chamber and the laser pit geometry can change the effectiveness of ablation and intensity of plasma light received. These effects introduce variation between the first and last spectra and so the quantification of K is more complex. The ablation of one crater can give, depending on the protocol of acquisition, from tens to hundreds of spectra. Protocol and results: We are in the process of further characterizing the variation introduced into LIBS spectra by the use of hundreds of laser shots, and definining a protocol that can be used to ensure accuracy and reporoducibility in the results.We are using natural rock powder standards fused in a furnace, as well as mars analog samples with known K content. We will show the result of the calibration and some new statistical approaches in order to apprehend the effects of the long time ablation on rocks under high vacuum.

Devismes, D.↗

Work and Fatigue Characteristics of Unsuited and Suited Humans During Isolated, Isokinetic Joint Motions

The effects of a pressurized suit on human performance were investigated. The suit is known as an Extra-vehicular Mobility Unit (EMU) and is worn by astronauts while working outside of their space craft in low earth orbit. Isolated isokinetic joint torques of three female and three male subjects (all experienced users of the suit) were measured while working at 100% and 80% of their maximum voluntary torque (MVT). It was found that the average decrease in the total amount of work done when the subjects were wearing the EMU was 48% and 41% while working at 100% and 80% MVT, respectively. There is a clear relationship between the MVT and the time and amount of work done until fatigue. In general the stronger joints took longer to fatigue and did more work than the weaker joints. However, it is not clear which joints are most affected by the EMU suit in terms of the amount of work done. The average amount of total work done increased by 5.2% and 20.4% for the unsuited and suited cases, respectively, when the subject went from working at 100% to 80% MVT. Also, the average time to fatigue increased by 9.2% and 25.6% for the unsuited and suited cases, respectively, when the subjects went from working at 100% to 80% MVT. The EMU also decreased the joint range of motion. It was also found that the experimentally measured torque decay could be predicted by a logarithmic equation. The absolute average error in the predictions was found to be 18.3% and 18.9% for the unsuited and suited subject, respectively, working at 100% MVT, and 22.5% and 18.8% for the unsuited and suited subject, respectively, working at 80% MVT. These results could be very useful in the design of future EMU suits, and planning of Extra-Vehicular Activit). (EVA) for the upcoming International Space Station assembly operations.

Gonzalez, L. Javier↗

Experimental Investigation of Flow Condensation in Microgravity

Future manned missions to Mars are expected to greatly increase the space vehicle's size, weight, and heat dissipation requirements. An effective means to reducing both size and weight is to replace single-phase thermal management systems with two-phase counterparts that capitalize upon both latent and sensible heat of the coolant rather than sensible heat alone. This shift is expected to yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients. A major challenge to this shift is a lack of reliable tools for accurate prediction of two-phase pressure drop and heat transfer coefficient in reduced gravity. Developing such tools will require a sophisticated experimental facility to enable investigators to perform both flow boiling and condensation experiments in microgravity in pursuit of reliable databases. This study will discuss the development of the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS), which was initiated in 2012 in collaboration between Purdue University and NASA Glenn Research Center. This facility was recently tested in parabolic flight to acquire condensation data for FC-72 in microgravity, aided by high-speed video analysis of interfacial structure of the condensation film. The condensation is achieved by rejecting heat to a counter flow of water, and experiments were performed at different mass velocities of FC-72 and water and different FC-72 inlet qualities. It is shown that the film flow varies from smooth-laminar to wavy-laminar and ultimately turbulent with increasing FC-72 mass velocity. The heat transfer coefficient is highest near the inlet of the condensation tube, where the film is thinnest, and decreases monotonically along the tube, except for high FC-72 mass velocities, where the heat transfer coefficient is enhanced downstream. This enhancement is attributed to both turbulence and increased interfacial waviness. One-ge correlations are shown to predict the average condensation heat transfer coefficient with varying degrees of success, and a recent correlation is identified for its superior predictive capability, evidenced by a mean absolute error of 21.7%.

microgravity↗

Ground Based, Millimeter Wave Measurement of Ozone in the Middle Atmosphere

There is a need for highly reliable measurements of stratospheric ozone. Policy makers worldwide concerned with public health rely oil a clear consensus from the scientific community as a basis for ozone-related environmental policy that has a significant impact oil national economies. Tile latest Such consensus was presented in WMO, and used in a 1999 meeting of the parties considering amendments to the Montreal Protocol oil Substances that Deplete the Ozone Layer. Tile scientific community, in turn, needs highly precise and accurate measurements of ozone levels, and small time derivatives of these levels, both in continued - development of its understanding of the physical and chemical processes involved and as clear evidence that these processes are occurring as stated. Over most of the world, changes in ozone levels are small. For example, over the heavily populated northern midlatitudes, the linearized rate of ozone decline is between 0.2% per year and 0.7% per year, depending on altitude. These values are small enough to make measurement requirements technically challenging. Data quality may suffer from imperfections in individual instruments. In one instance, early results from a satellite-borne ozone sensor were later found to be invalid because of calibration drift. Even in the absence of drift, tile absolute calibration of a new sensor may differ slightly from that of its predecessor in service. Most ozone remote sensing instruments operate at ultraviolet or infrared wavelengths where scattering from dust and aerosols must be taken into account; results from these systems may be or are affected following a major volcanic eruption, such as tile one at Mt. Pinatubo in 1991. Given these difficulties, a consensus of measurements from several independent systems is required to insure a reliable understanding of stratospheric ozone levels. Because of the above-described need for highly precise and accurate ozone measurements using several independent techniques, there was interest in developing several techniques which were known but not highly developed in the 1980's into systems capable of being used in ail operational manner to make measurements with the level of quality needed to-detect small trends in ozone levels. A ground-based microwave instrument capable of remotely sensing stratospheric ozone had been designed by tile Principal Investigator of the present project. This instrument was built at tile Millitech Corporation in South Deerfield, Massachusetts before tile present work began. (Funding for design and construction of the instrument came from sources other than the present grant.) Tile instrument measured the spectrum of one of the many emission lines produced by purely rotational transitions of ozone, one at a frequency of 110.8 GHz. The altitude distribution of ozone can. in principle, be retrieved from the details of the pressure-broadened spectrum of the ozone transition. However, the level of contamination of the spectral measurement by instrumentally induced artifacts must be very low in order to retrieve a ozone profile of useful quality from it. The Millitech instrument demonstrated spectral purity at ail adequate level, and there were promising ideas for instrumental improvements and for further development of the technique. The initial objectives of the present project, then, were to develop techniques for calibrating the Millitech instrument, to minimize artifacts in tile spectra it produces, to optimally retrieve ozone profiles from tile spectra, to test tile quality of the microwave profiles by comparing them with profiles obtained using several other, independent techniques over both short and periods of time, and to perform research using the ozone data gathered with the instrument.

Parrish, Alan↗

Solar Array in Simulated LEO Plasma Environment

Six different types of solar arrays have been tested in large vacuum chambers. The low earth orbit plasma environment was simulated in plasma vacuum chambers, where the parameters could be controlled precisely. Diagnostic equipment included spherical Langmuir probes, mass spectrometer, low-noise CCD camera with optical spectrometer, video camera, very sensitive current probe to measure arc current, and a voltage probe to register variations in a conductor potential. All data (except video) were obtained in digital form that allowed us to study the correlation between external parameters (plasma density, additional capacitance, bias voltage, etc) and arc characteristics (arc rate, arc current pulse width and amplitude, gas species partial pressures, and intensities of spectral lines). Arc inception voltages, arc rates, and current selections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness cases the increase in arc inception voltage. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 micron coverglass thickness and 60 V for the sample with 150 micron coverglass thickness. Installation of cryogenic pump in large vacuum chamber provided the possibility of considerable outgassing of array surfaces which resulted in significant decrease of arc rate. Arc sites were determined by employing a video-camera, and it is shown that the most probable sites for arc inception are triple-junctions, even though some arcs were initiated in gaps between cells. It is also shown that the arc rate increases with increasing of ion collection current. The analysis of optical spectra (240-800 nm) reveals intensive narrow atomic lines (Ag, H) and wide molecular bands (OH, CH, SiH, SiN) that confirms a complicated mechanism of arc plasma generation. The results obtained seem to be important for the understanding of the arc inception mechanism, which is absolutely essential for progress toward the design of high-voltage solar array for space application.

Vayner, Boris↗

Solar Array in Simulated LEO Plasma Environment

Six different types of solar arrays have been tested in large vacuum chambers. The low Earth orbit plasma environment was simulated in plasma vacuum chambers, where the parameters could be controlled precisely. Diagnostic equipment included spherical Langmuir probes, mass spectrometer, low-noise CCD camera with optical spectrometer, video camera, very sensitive current probe to measure arc current, and a voltage probe to register variations in a conductor potential. All data (except video) were obtained in digital form that allowed us to study the correlation between external parameters (plasma density, additional capacitance, bias voltage, etc) and arc characteristics (arc rate, arc current pulse width and amplitude, gas species partial pressures, and intensities of spectral lines). Arc inception voltages, arc rates, and current collections are measured for samples with different coverglass materials and thickness, interconnect designs, and cell sizes. It is shown that the array with wrapthrough interconnects have the highest arc threshold and the lowest current collection. Coverglass design with overhang results in decrease of current collection and increase of arc threshold. Doubling coverglass thickness causes the increase in arc inception voltage. Both arc inception voltage and current collection increase significantly with increasing a sample temperature to 80 C. Sustained discharges are initiated between adjacent cells with potential differences of 40 V for the sample with 300 m coverglass thickness and 60 V for the sample with 150 m coverglass thickness. Installation of cryogenic pump in large vacuum chamber provided the possibility of considerable outgassing of array surfaces which resulted in significant decrease of arc rate. Arc sites were determined by employing a video-camera, and it is shown that the most probable sites for arc inception are triple-junctions, even though some arcs were initiated in gaps between cells. It is also shown that the arc rate increases with increasing of ion collection current. The analysis of optical spectra (240-800 nm) reveals intensive narrow atomic lines (Ag, H) and wide molecular bands (OH, CH, SiH, SiN) that confirms a complicated mechanism of arc plasma generation. The results obtained seem to be important for the understanding of the arc inception mechanism, which is absolutely essential for progress toward the design of high-voltage solar array for space application.

Vayner, Boris↗

Effects of acute fresh water exposure on water flux rates and osmotic responses in Kemp's ridley sea turtles (Lepidochelys kempi)

Water flux rates and osmotic responses of Kemp's Ridley sea turtles (Lepidochelys kempi) acutely exposed to fresh water were quantified. Salt-water adapted turtles were exposed to fresh water for 4 d before being returned to salt water. During the initial salt water phase, absolute and relative water flux rates were 1.2+/-0.1 l d(-1) and 123.0+/-6.8 ml kg(-1) d(-1), respectively. When turtles were exposed to fresh water, rates increased by approximately 30%. Upon return to salt water, rates decreased to original levels. Plasma osmolality, Na(+), K(+), and Cl(-) decreased during exposure to fresh water, and subsequently increased during the return to salt water. The Na(+):K(+) ratio was elevated during the fresh water phase and subsequently decreased upon return to salt water. Aldosterone and corticosterone were not altered during exposure to fresh water. Elevated water flux rates during fresh water exposure reflected an increase in water consumption, resulting in a decrease in ionic and osmotic concentrations. The lack of a change in adrenocorticoids to acute fresh water exposure suggests that adrenal responsiveness to an hypo-osmotic environment may be delayed in marine turtles when compared to marine mammals.

Non-programmatic↗

The Feasibility of Tropospheric and Total Ozone Determination Using a Fabry-perot Interferometer as a Satellite-based Nadir-viewing Atmospheric Sensor

Monitoring of the global distribution of tropospheric ozone (O3) is desirable for enhanced scientific understanding as well as to potentially lessen the ill-health impacts associated with exposure to elevated concentrations in the lower atmosphere. Such a capability can be achieved using a satellite-based device making high spectral resolution measurements with high signal-to-noise ratios; this would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface, interfering species, and clouds. The Fabry-Perot Interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance. Decreasing stratospheric O3 concentrations may lead to an increase in biologically harmful solar ultraviolet radiation reaching the earth's surface, which is detrimental to health. In this research, a conceptual instrument design to achieve the desired measurement has been formulated. This involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). A spectral region of about 1 cm(exp -1) wide centered at 1054.73 cm(exp -1) within the strong 9.6 micron ozone infrared band is sampled with 24 spectral channels. Other design characteristics include operation from a nadir-viewing satellite configuration utilizing a 9 inch (diameter) telescope and achieving horizontal spatial resolution with a 50 km nadir footprint. A retrieval technique has been implemented and is demonstrated for a tropical atmosphere possessing enhanced tropospheric ozone amounts. An error analysis assessing the impact on retrieved O3 amounts of the most significant uncertainties associated with this particular measurement has been performed for several different types of atmospheres. Results show the proposed instrumentation to enable a good measurement of absolute ozone amounts and an even better determination of relative changes, with a range of accuracy to within 7.55 to 20.6 percent for integrated tropospheric amounts (and 1.99 to 4.02 percent for total O3 column abundance) and a corresponding range in precision to within 7.73 to 10.4 percent (and 3.30 to 3.95 percent for total O3 column abundance), for the atmospheric conditions considered.

Larar, Allen Maurice↗

Combustion of Metals in Reduced-Gravity and Extra Terrestrial Environments

The combustion of metals is a field with important practical applications in rocket propellants, high-temperature flames, and material synthesis. Also, the safe operation of metal containers in high-pressure oxygen systems and with cryogenic fuels and oxidizers remains an important concern in industry. The increasing use of metallic components in spacecraft and space structures has also raised concerns about their flammability properties and fire suppression mechanisms. In addition, recent efforts to embark on unmanned and manned planetary exploration, such as on Mars, have also renewed the interest in metal/carbon-dioxide combustion as an effective in situ resource utilization technology. In spite of these practical applications, the understanding of the combustion properties of metals remains far behind that of the most commonly used fuels such as hydrocarbons. The lack of understanding is due to the many problems unique to metal- oxidizer reactions such as: low-temperature surface oxidation prior to ignition, heterogeneous reactions, very high combustion temperatures, product condensation, high emissivity of products, and multi-phase interactions. Very few analytical models (all neglecting the influence of gravity) have been developed to predict the burning characteristics and the flame structure details. Several experimental studies attempting to validate these models have used small metal particles to recreate gravity-free conditions. The high emissivity of the flames, rapid reaction, and intermittent explosions experienced by these particles have made the gathering of any useful information on burning rates and flame structure very difficult. The use of a reduced gravity environment is needed to clarify some of the complex interactions among the phenomena described above. First, the elimination of the intrusive buoyant flows that plague all combustion phenomena is of paramount importance in metal reactions due to the much higher temperatures reached during combustion. Second, a low-gravity environment is absolutely essential to remove the destructive effect of gravity on the shape of a molten metal droplet in order to study a spherically symmetric condition with large bulk samples. The larger size of the spherical metal droplet and the longer burning times available in reduced gravity extend the spatial and temporal dimensions to permit careful probing of the flame structure and dynamics. Third, the influence of the radiative heat transfer from the solid oxides can be studied more carefully by generating a stagnant spherical shell of condensed products undisturbed by buoyancy.

Branch, M.C.↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Work and fatigue characteristics of unsuited and suited humans during isolated isokinetic joint motions

The effects of a pressurized suit on human performance were investigated. The suit is known as an Extra-Vehicular Mobility Unit (EMU) and is worn by astronauts while working outside their spacecraft in a low earth orbit. Isolated isokinetic joint torques of three female and three male subjects (all experienced users of the suit in 1G gravity) were measured while working at 100% and 80% of their maximum voluntary torque (MVT, which is synonymous with maximum voluntary contraction (MVC)). It was found that the average decrease in the total amount of work (the sum of the work in each repetition until fatigue) done when the subjects were wearing the EMU were 48% and 41% while working at 100% and 80% MVT, respectively. There is a clear relationship between the MVT and the time and amount of work done until fatigue. Here, the time to fatigue is defined as the ending time of the repetition for which the computed work done during that repetition dropped below 50% of the work done during the first repetition. In general the stronger joints took longer to fatigue and did more work than the weaker joints. It was found that the EMU decreases the work output at the wrist and shoulder joints the most, due to the EMU joint geometry. The EMU also decreased the joint range of motion. The average total amount of work done by the test subjects increased by 5.2% (20.4%) for the unsuited (suited) case, when the test subjects decreased the level of effort from 100% to 80% MVT. Also, the average time to fatigue increased by 9.2% (25.6%) for the unsuited (suited) case, when the test subjects decreased the level of effort from 100% to 80% MVT. It was also found that the experimentally measured torque decay could be predicted by a logarithmic equation. The absolute average errors in the predictions were found to be 18.3% and 18.9% for the unsuited and suited subjects, respectively, when working at 100% MVT, and 22.5% and 18.8% for the unsuited and suited subjects, respectively, when working at 80% MVT. These results could be very useful in the design of future EMU suits and the planning of Extra-Vehicular Activity (EVA) for the future International Space Station assembly operations.

NASA Discipline Life Sciences Technologies↗

Atomic oxygen density determination in the effluent of the COST reference source using in situ effective lifetime measurements in the presence of a liquid interface

Abstract Spatially resolved, absolute densities of atomic oxygen are measured for several helium-based admixtures in the effluent of the COST Reference Microplasma Jet using two-photon absorption laser induced fluorescence (TALIF). Admixtures investigated include a helium-only admixture, four helium/oxygen admixtures (0.1 % , 0.5 % , 0.6 % , and 1.0 % oxygen), and a helium/water admixture (2500 ppm water), chosen to coincide with previously published characterizations of plasma-treated liquid. The atomic oxygen TALIF signal is calibrated for density using the noble gas xenon, which possesses a very similar two-photon excitation and fluorescence scheme. Measurements are conducted for the jet operating in ambient air with both an open effluent and a liquid surface present, allowing for comparison with liquid phase measurements conducted under similar conditions. The presence of a water surface does not appear to alter the background chemistry in the effluent but reduces O densities close to the liquid interface when compared to a similar distance from the nozzle in an open effluent case. This may be the result of a reduction in flow velocity caused by the liquid obstructing the gas flow. Additionally, measurements near the liquid surface revealed a region of atomic oxygen well outside of where the core of the effluent impinges on the liquid. This is likely relevant for applications as it considerably expands the surface area subject to O absorption. Critically, in situ measurements of the effective lifetimes of the laser-excited 3p 3 P J state of atomic oxygen were recorded in the effluent by employing a picosecond (ps) laser and a nanosecond (ns) ICCD. By experimentally determining the contribution from collisional quenching via the in situ effective lifetime measurements, significant improvements in the accuracy of the atomic oxygen density calibration were made, with differences of approximately 30 % from existing methods of estimating quenching rates at atmospheric pressure. Finally, spatially resolved atomic oxygen densities allow for an investigation of O formation and extinction pathways in the effluent and a comparison between admixtures.

laser diagnostics↗

Additional Trials & Tribulations in Synthesizing a Sulfide Standard

Well-characterized sulfide reference materials that can serve as matrix-matched calibrants for in-situ trace element analyses via laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) remain elusive. Here, we describe the creation an in-house sulfide standard at NASA JSC that will be used to measure siderophile and chalcophile trace elements in low pressure experimental products, specifically pentlandite ([FeNi]9S8) and pyrrhotite ([FeNi]1-xS), as well as natural sulfides in terrestrial and meteoritic mineral assemblages. Recent methods in creating a homogenous sulfide standard include pressed pellets, synthesized chips, or fused glass [e.g. 1-3]. Other studies, however, have had success in forming homogenous FeS standards via synthesization methods [e.g. 4-6]. We present a variation of the method described in [4], in which we create a pyrrhotite standard doped with a variety of trace elements (Zn, As, Se, Mo, Ru, Rh, Pd, Sn, Sb, Te, W, Os, Ir, Pt, Au) at ~10-40 ppm and Cu at ~200 ppm. Sulfide compositions were constructed using Fe and Ni metal and elemental sulfur powders. Trace elements were added to elemental sulfur from Atomic Absorption Spectroscopy (AAS) elemental standards as either nitrate or chloride solutions to prevent oxidation of the metal powders. The dried sulfur mixture was mixed with Fe and Ni powders and mechanically mixed before two aliquots were placed in separate SiO2 tubes. Each tube was held under vacuum for ~30 minutes, sealed under vacuum, and then heated at 800C for 48 hours. Like [4], the synthesis products were composed of pourous sulfide crystals. Major element analyses of both experimental aliquots, collected using an Electron Probe Microanalyser (EPMA), yield indistinguishable major element compositions (uncertainties in 2SE & 2RSE[%]), with an average of 57.90  0.09 (0.16 %), 4.95  0.03 (0.55 %), and 39.70  0.14 (0.34 %), for Fe, Ni, and S, respectively. Trace element data were measured using a Photon Machines 193nm laser ablation system coupled to a Thermo-Scientific Element-XR ICP-MS. Spot sizes were limited to 50 μm due to the porous nature of the sulfide target material. Trace element abundances, normalized to Fe as an internal standard, were also found to be homogenous between the two aliquots, with weighted mean 2RSE (%) values of <3.0 for all trace elements. Synthesized products were re-powdered and absolute concentrations measured via solution ICP-MS. Although the sulfide appears to be homogenous, sintering experiments will be performed to more closely match the standard density to natural sulfides and minimize differences in ablation behavior. Improved density also allows for higher sensitivity (i.e. more compact target material) and larger spot sizes or traverses, as void space is eliminated. Additional major and trace element analyses on the products of the sintering experiments will be undertaken.

Jacob B Setera↗