Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Accelerator-Based Production of Scandium Radioisotopes for Applications in Prostate Cancer: Toward Building a Pipeline for Rapid Development of Novel Theranostics

In the field of nuclear medicine, the β + -emitting 43 Sc and β - -emitting 47 Sc are promising candidates in cancer diagnosis and targeted radionuclide therapy (TRT) due to their favorable decay schema and shared pharmacokinetics as a true theranostic pair. Additionally, scandium is a group-3 transition metal (like 177 Lu) and exhibits affinity for DOTA-based chelators, which have been studied in depth, making the barrier to implementation lower for 43/47 Sc than for other proposed true theranostics. Before 43/47 Sc can see widespread pre-clinical evaluation, however, an accessible production methodology must be established and each isotope’s radiolabeling and animal imaging capabilities studied with a widely utilized tracer. As such, a simple means of converting an 18 MeV biomedical cyclotron to support solid targets and produce 43 Sc via the 42 Ca(d,n) 43 Sc reaction has been devised, exhibiting reasonable yields. The Nat Ti(γ,p) 47 Sc reaction is also investigated along with the successful implementation of chemical separation and purification methods for 43/47 Sc. The conjugation of 43/47 Sc with PSMA-617 at specific activities of up to 8.94 MBq/nmol and the subsequent imaging of LNCaP-ENZaR tumor xenografts in mouse models with both 43/47 Sc-PSMA-617 are also presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE USE OF KF STYLE FLANGES IN LOW PARTICULATE APPLICATIONS

As SCRF particle accelerator technology advances the need for “low particulate” and “particle free” vacuum sys-tems becomes greater and greater. In the course of the op-eration of these systems, there comes a time when various instruments have to be temporarily attached for diagnostic purposes: RGAs, leak detectors, and additional pumps. In an effort to make the additions of these instruments easier and more time effective, we propose to use KF style flanges for these types of temporary diagnostic connec-tions. This document will describe the tests used to com-pare the particles generated using the assembly of the, widely accepted for “particle free” use, conflat flange to the proposed KF style flange, and demonstrate that KF flanges produce comparable or even less particles

43 PARTICLE ACCELERATORS↗

Bridging the Gap Between Modern UX Design and Particle Accelerator Control Room Interfaces

Accelerator control systems often represent relatively complex and safety-sensitive human-machine interfaces within process control industries. These systems are technically robust and reflect the cumulative integration of solutions built and adapted across decades. One of the regular, unfortunate casualties of provisional accelerator control system updates is their human-system interfaces (HSIs) which often lag behind modern usability and design standards. An additional challenge is that although there is a multitude of established human factors (HF), and user experience (UX) principles for everyday digital applications, there are very few (if any) established principles for complex and safety-critical applications for an accelerator. This paper argues for the importance of established HF and UX principles (herein referred to as human-centered design principles) into the development of accelerator HSIs, emphasizing the need for clarity, consistency, responsiveness, and cognitive accessibility. Drawing from HF/UX best practices and human-centered design, this paper discusses how these approaches can enhance operator performance, reduce human error, and improve accelerator personnel collaboration. Case studies from Accelerator Control Operations Research Network (ACORN) at Fermilab are explored to demonstrate how interfaces built with human-centered design principles can scale with system complexity while remaining intuitive and efficient for diverse user roles including operators, machine experts, and engineers. By bridging the gap between traditional control system design and modern human-centered design methods, this paper provides a roadmap for evolving accelerator HSIs into more usable, maintainable, and effective tools.

Hill, Rachael [Idaho Natl. Lab.]↗

Facility for Advanced Accelerator Experimental Tests at SLAC (FACET) Conceptual Design Report

This Conceptual Design Report (CDR) describes the design of FACET. It will be updated to stay current with the developing design of the facility. This CDR begins as the baseline conceptual design and will evolve into an 'as-built' manual for the completed facility. The Executive Summary, Chapter 1, gives an introduction to the FACET project and describes the salient features of its design. Chapter 2 gives an overview of FACET. It describes the general parameters of the machine and the basic approaches to implementation. The FACET project does not include the implementation of specific scientific experiments either for plasma wake-field acceleration for other applications. Nonetheless, enough work has been done to define potential experiments to assure that the facility can meet the requirements of the experimental community. Chapter 3, Scientific Case, describes the planned plasma wakefield and other experiments. Chapter 4, Technical Description of FACET, describes the parameters and design of all technical systems of FACET. FACET uses the first two thirds of the existing SLAC linac to accelerate the beam to about 20GeV, and compress it with the aid of two chicanes, located in Sector 10 and Sector 20. The Sector 20 area will include a focusing system, the generic experimental area and the beam dump. Chapter 5, Management of Scientific Program, describes the management of the scientific program at FACET. Chapter 6, Environment, Safety and Health and Quality Assurance, describes the existing programs at SLAC and their application to the FACET project. It includes a preliminary analysis of safety hazards and the planned mitigation. Chapter 7, Work Breakdown Structure, describes the structure used for developing the cost estimates, which will also be used to manage the project. The chapter defines the scope of work of each element down to level 3.

43 PARTICLE ACCELERATORS↗

Proposed New Accelerator Design for Homeland Security X-Ray Applications

In the security and inspection market, there is a push towards highly mobile, reduced-dose active interrogation scanning and imaging systems to allow operation in urban environments. To achieve these goals, the accelerator system design needs to be smaller than existing systems. A smaller radiation exclusion zone may be accomplished through better beam collimation and an integrated, x-ray-source/detector-array assembly to allow feedback and control of an intensity-modulated x-ray source. A shaped low-Z target in the x-ray source can be used to generate a more forward peaked x-ray beam. Electron-beam steering can then be applied to direct the forward-peaked x rays toward areas in the cargo with high attenuation. This paper presents an exploratory study to identify components and upgrades that would be required to meet the desired specifications, as well as the best technical approach to design and build a prototype.

43 PARTICLE ACCELERATORS↗

Monitoring applications once they are in the user community

Once an application is released into the user community, obtaining prompt and high quality information on application usage, applicability and reliability can be a challenge. Most Linux and Solaris applications used at RHIC and associated accelerators have been instrumented so that application and crash information is gathered, stored and forwarded to the appropriate developer for immediate analysis. To support this process, databases were created to track developer and application information. In order to keep these databases relevant, a web based application release procedure was created to collect information and automatically update the database. Additional capabilities have been developed that utilize and expand on the various components of this system to promote communication between developers and users, and to monitor applications. An application feedback feature allows users to instantly communicate with application developers. An application history system records application usage and reliability.

43 PARTICLE ACCELERATORS↗

MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current capabilities and future needs for semiconductor ion implantation (invited)

For many years the largest commercial application for particle accelerators has been semiconductor ion implantation. These tools differ from other accelerators in many respects. In particular they are automated to a very high degree and, in addition to technical performance requirements their success depends on other key metrics including productivity, availability and cost of ownership. These tools also operate with a large variety of species, four orders of magnitude of energy range and five orders of magnitude of dose range. The ion source is a key component of implanters with its own performance metrics that include beam current, lifetime, and materials cost. In this paper, we describe the primary applications for ion implantation and some of the beam line architectures that are used. We describe the ion source that has evolved for this application. Some key future challenges for implanter ion source development are also discussed.

36 MATERIALS SCIENCE↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

ELECTRON ACCELERATION IN PULSAR-WIND TERMINATION SHOCKS: AN APPLICATION TO THE CRAB NEBULA GAMMA-RAY FLARES

The γ -ray flares from the Crab Nebula observed by AGILE and Fermi -LAT reaching GeV energies and lasting several days challenge the standard models for particle acceleration in pulsar-wind nebulae because the radiating electrons have energies exceeding the classical radiation-reaction limit for synchrotron. Previous modeling has suggested that the synchrotron limit can be exceeded if the electrons experience electrostatic acceleration, but the resulting spectra do not agree very well with the data. As a result, there are still some important unanswered questions about the detailed particle acceleration and emission processes occurring during the flares. We revisit the problem using a new analytical approach based on an electron transport equation that includes terms describing electrostatic acceleration, stochastic wave-particle acceleration, shock acceleration, synchrotron losses, and particle escape. An exact solution is obtained for the electron distribution, which is used to compute the associated γ -ray synchrotron spectrum. We find that in our model the γ -ray flares are mainly powered by electrostatic acceleration, but the contributions from stochastic and shock acceleration play an important role in producing the observed spectral shapes. Our model can reproduce the spectra of all the Fermi -LAT and AGILE flares from the Crab Nebula, using magnetic field strengths in agreement with the multi-wavelength observational constraints. We also compute the spectrum and duration of the synchrotron afterglow created by the accelerated electrons, after they escape into the region on the downstream side of the pulsar-wind termination shock. The afterglow is expected to fade over a maximum period of about three weeks after the γ -ray flare.

79 ASTRONOMY AND ASTROPHYSICS↗