Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Diagnostic accuracy of MRI with extracellular vs. hepatobiliary contrast material for detection of residual hepatocellular carcinoma after locoregional treatment

Purpose: To compare the diagnostic accuracy of extracellular gadolinium-based contrast-enhanced MRI (Gd-MRI) and gadoxetic acid-enhanced MRI (EOB-MRI) for the assessment of hepatocellular carcinoma (HCC) response to locoregional therapy (LRT) using explant correlation as the reference standard. Methods: Forty-nine subjects with cirrhosis and HCC treated with LRT who underwent liver MRI using either Gd-MRI (n = 26) or EOB-MRI (n = 23) within 90 days of liver transplantation were included. Four radiologists reviewed the MR images blinded to histology to determine the size and percentage of viable residual HCC using a per-lesion explant reference standard. Sensitivities, specificities, accuracies, and agreement with histology for the detection residual HCC were calculated. Results: Gd-MRI had greater agreement with histology (ICC: 0.98 [0.95–0.99] vs. 0.80 [0.63–0.90]) and greater sensitivity for viable HCC (76% [13/17 50–93%] vs. 58% [7/12; 28–85%]) than EOB-MRI; specificities were similar (84% [16/19; 60–97%] vs. 85% [23/27; 66–96%]). Areas under ROC curves for detecting residual viable tumor were 0.80 (0.64–0.92) for Gd-MRI and 0.72 (0.55–0.85) for EOB-MRI. Gd-MRI had greater inter-rater agreement than EOB-MRI for determining the size of residual viable HCC (ICC: 0.96 [0.92–0.98] vs. 0.85 [0.72–0.92]). Conclusion: Gd-MRI may be more accurate and precise than EOB-MRI for the assessment of viable HCC following LRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prenatal planning of placenta previa: diagnostic accuracy of a novel MRI-based prediction model for placenta accreta spectrum (PAS) and clinical outcome

Purpose: To investigate the diagnostic accuracy of MRI for placenta accreta spectrum (PAS) and clinical outcome prediction in women with placenta previa, using a novel MRI-based predictive model. Methods: Thirty-eight placental MRI exams performed on a 1.5T scanner were retrospectively reviewed by two radiologists in consensus. The presence of T2 dark bands, myometrial thinning, abnormal vascularity, uterine bulging, placental heterogeneity, placental protrusion sign, placental recess, and percretism signs was scored using a 5-point scale. Pathology and clinical intrapartum findings were the standard of reference for PAS, while intrapartum/peripartum bleeding and emergency hysterectomy defined the clinical outcome. Receiver-operating characteristic (ROC) analysis and discriminant function analysis were performed to test the predictive power of MRI findings for both PAS and clinical outcome prediction. Results: Abnormal vascularity and percretism signs were the two most predictive MRI features of PAS. The area under the curve (AUC) of the predictive function was 0.833 (cutoff 0.39, 67% sensitivity, 100% specificity, p = 0.001). Percretism signs and myometrial thinning were the two most predictive MRI features of poor outcome. AUC of the predictive function was 0.971 (cutoff − 0.55, 100% sensitivity, 77% specificity, p < 0.001). Conclusion: The diagnostic accuracy of MRI, especially considering the combination of the most predictive MRI findings, is higher when the target of the prediction is the clinical outcome rather than the PAS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative accuracy of qualitative and quantitative 18F-FDG PET/CT analysis in detection of lymph node metastasis from anal cancer

Purpose: To compare the diagnostic performance of qualitative and quantitative 18F-FDG PET/CT in detection of regional and distant lymph node metastasis in patients with anal cancer. Methods: Between 2004 and 2017, 28 patients with anal cancer who had staging PET/CT and pathological assessment of suspicious lymph nodes were included. For qualitative analysis, positive lymph nodes were defined as uptake visually higher than the liver reference uptake. For quantitative study, lymph nodes were contoured to determine maximum standard uptake value (SUV{sub max}) and metabolic tumor volume (MTV). Receiver operating characteristic (ROC) curves were plotted to extract the optimal cut-offs and area under the curve (AUC) of SUV{sub max}, lesion to background (L/B) ratio, short axis diameter (SAD), and MTV of lymph nodes. Histopathologic analysis was a reference standard. Results: A total of 28 lymph nodes (24 inguinal, 2 external iliac, 1 internal iliac, and 1 paraaortic nodes) in 28 patients on PET/CT were included. With the qualitative visual analysis, 19 patients were categorized as positive for nodal metastasis with sensitivity, specificity, and accuracy of 85%, 75%, and 82%. The optimal SUV{sub max} and L/B ratio cut-offs were 2.6 and 1.0 with both sensitivity and specificity of 95% and 75% (AUC of SUV{sub max} = 0.893, AUC of L/B ratio = 0.912). Using the best cut-off of 1.6 cm for SAD and 3.65 cm{sup 3} for MTV, both sensitivity and specificity were 80% and 100% (AUC of SAD = 0.950, AUC of MTV = 0.931). Conclusions: SUV{sub max} optimization may be helpful in enhancing the diagnostic accuracy of 18F-FDG PET/CT in nodal staging patients with anal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision and accuracy of magnetic resonance imaging for lobar classification of benign prostatic hyperplasia

Purpose: To validate the application of a magnetic resonance imaging (MRI)-based lobar classification of benign prostatic hyperplasia (BPH) for use in research and clinical management. Methods: Two radiologists with 5 and 11 years post-fellowship experience were trained in the lobar classification of BPH using an internally developed atlas of prostate anatomy with example MRI images edited by a third senior radiologist designated as the “administrator” of the study. A study population of 140 patients referred to a tertiary academic medical center with known or suspected prostate cancer was selected by the administrator to test the interrater reliability (IRR; precision) of the classification as well as accuracy of the two readers compared to the administrator as the “gold” standard. The intrarater reliability of repeat readings of the administrator was also examined. Percentage of agreement, proportion of agreement, and Cohen’s κ were applied. This was a retrospective IRB-approved study. Results: IRR (precision) between the two interpreting radiologists was 64% agreement, corresponding to unweighted κ of 0.52. Composite proportion of agreement across all BPH types (categories) for interpreting radiologists was 0.67. Observer accuracy was 62% agreement, unweighted κ 0.49, for observer 1 and 67%, unweighted κ 0.58, for observer 2. Intrarater reliability for the administrator was 87% agreement, unweighted κ 0.81 with composite proportion of agreement across all categories of 0.87. Conclusions: MRI lobar classification of BPH is a reproducible and reliable tool for research and clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Genetic Algorithm (GA) Assisted Partial Least Square (PLS) Analysis on Trilinear and Non-trilinear Fluorescence Data Sets to Quantify the Fluorophores in Multifluorophoric Mixtures: Improving Quantification Accuracy of Fluorimetric Estimations of Dilute Aqueous Mixtures

Excitation-emission matrix fluorescence (EEMF) and total synchronous fluorescence spectroscopy (TSFS) are the 2 fluorescence techniques that are commonly used for the analysis of multifluorophoric mixtures. These 2 fluorescence techniques are conceptually different and provide certain advantages over each other. The manual analysis of such highly correlated large volume of EEMF and TSFS towards developing a calibration model is difficult. Partial least square (PLS) analysis can analyze the large volume of EEMF and TSFS data sets by finding important factors that maximize the correlation between the spectral and concentration information for each fluorophore. However, often the application of PLS analysis on entire data sets does not provide a robust calibration model and requires application of suitable pre-processing step. The present work evaluates the application of genetic algorithm (GA) analysis prior to PLS analysis on EEMF and TSFS data sets towards improving the precision and accuracy of the calibration model. The GA algorithm essentially combines the advantages provided by stochastic methods with those provided by deterministic approaches and can find the set of EEMF and TSFS variables that perfectly correlate well with the concentration of each of the fluorophores present in the multifluorophoric mixtures. The utility of the GA assisted PLS analysis is successfully validated using (i) EEMF data sets acquired for dilute aqueous mixture of four biomolecules and (ii) TSFS data sets acquired for dilute aqueous mixtures of four carcinogenic polycyclic aromatic hydrocarbons (PAHs) mixtures. In the present work, it is shown that by using the GA it is possible to significantly improve the accuracy and precision of the PLS calibration model developed for both EEMF and TSFS data set. Hence, GA must be considered as a useful pre-processing technique while developing an EEMF and TSFS calibration model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing scalability and accuracy of quantum poisson solver

The Poisson equation has many applications across the broad areas of science and engineering. Most quantum algorithms for the Poisson solver presented so far either suffer from lack of accuracy and/or are limited to very small sizes of the problem and thus have no practical usage. In this regard, our previous work showed a proof-of-concept demonstration in advancing quantum Poisson solver algorithm and validated preliminary results for a simple case of 3 x 3 problem. In this work, we delve into comprehensive research details, presenting the results on up to 15 x 15 problems that include step-by-step improvements in Poisson equation solutions, scaling performance, and experimental exploration. In particular, we demonstrate the implementation of eigenvalue amplification by a factor of up to 2 8 , achieving a significant improvement in the accuracy of our quantum Poisson solver and comparing that to the exact solution. Additionally, we present success probability results, highlighting the reliability of our quantum Poisson solver. Moreover, we explore the scaling performance of our algorithm against the circuit depth and width, demonstrating how our approach scales with larger problem sizes and thus further solidifies the practicality of easy adaptation of this algorithm in real-world applications. We also discuss a multilevel strategy for how this algorithm might be further improved to explore much larger problems with greater performance. Finally, through our experiments on the IBM quantum hardware, we conclude that though overall results on the existing NISQ hardware are dominated by the error in the CNOT gates, this work opens a path to realizing a multidimensional Poisson solver on near-term quantum hardware.

97 MATHEMATICS AND COMPUTING↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

An assessment of the safety, hemodynamic response, and diagnostic accuracy of commonly used vasodilator stressors in patients with severe aortic stenosis

Background: Increasing numbers of patients are undergoing transcatheter aortic valve replacement, which often involves assessment of coronary artery disease ischemic burden. The safety and diagnostic accuracy of vasodilator stress agents in patients with severe aortic stenosis (AS) undergoing SPECT myocardial perfusion imaging (MPI) has not been established. Methods: Patients with severe AS (valve area <1 cm{sup 2}) on echocardiography who underwent vasodilator stress SPECT MPI at two centers were identified. Patients with aortic valve intervention prior to MPI or who underwent concurrent exercise during stress testing were excluded. AS patients were matched to controls without AS based on age, gender, BMI, ejection fraction, and stress agent. Symptoms, serious adverse events, hemodynamic response, and correlation to invasive angiography were assessed. Results: A total of 95 cases were identified with 45% undergoing regadenoson, 31% dipyridamole, and 24% adenosine stress. A significant change in systolic blood pressure (BP), cases vs controls, was observed with adenosine [−17.9 ± 20.1 vs −2.6 ± 24.9 P = .03)], with a trend toward significance with regadenoson [−16.8 ± 20.3 vs −9.4 ± 17.9 (P = .08)] and dipyridamole [−17.8 ± 20.6 vs -9.0 ± 12.1 (P = .05)]. The change in heart rate was significantly different only for adenosine [5.3 ± 16.8 vs 14.2 ± 10.8 (P = .04)]. Overall, 45% of cases vs 24% of controls (P = .004) had a >20 mmHg decrease in systolic BP. Age, BMI, and resting systolic BP were related to a >20 mmHg decrease in systolic BP on univariate analysis, although only higher resting systolic BP was a predictor on multivariate analysis. In 33 patients who underwent angiography, the sensitivity, specificity, and diagnostic accuracy of vasodilator stress MPI was 77%, 69%, and 73%, respectively. No serious adverse events occurred in the severe AS patients. Conclusion: Severe AS patients are more likely to have a hemodynamically significant decrease in systolic BP with vasodilator stress. There were no serious adverse events in this severe AS cohort with good diagnostic performance of MPI compared to angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the accuracy of common γ-Al 2 O 3 structure models by selected area electron diffraction from high-quality crystalline γ-Al 2 O 3

Single crystal and textured polycrystalline γ-Al 2 O 3 thin films were synthesized by oxidation of NiAl(110) in air at 850 °C for 1 and 2 hours, respectively, and used to evaluate the accuracy of two spinel-based and two nonspinel models by comparison of selected-area electron diffraction (SAED). The lattice interplanar distances derived from the polycrystalline SAED pattern most closely matched the cubic spinel γ-Al 2 O 3 model. The single-crystal SAED spot pattern reflected symmetry consistent with both the cubic spinel and tetragonal nonspinel models, yet, the Al cation distribution better matched the cubic spinel model based on the relative intensities of diffraction spots. Our work indicates that the traditional cubic spinel model is a more accurate model of γ-Al 2 O 3 than the other models considered. Furthermore, the spinel-based monoclinic model is more accurate than the monoclinic nonspinel model. The understanding of the relative accuracy of the different models is key for simulating γ-Al 2 O 3 containing systems and is of general interest for the metal oxide and ceramic communities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A new procedure for implementing the modified inherent strain method with improved accuracy in predicting both residual stress and deformation for laser powder bed fusion

As a metal additive manufacturing (AM) process, laser powder bed fusion (L-PBF) has been widely used to produce parts with complex geometries. The large thermal gradient caused by the fast, intense, and repeated laser scanning induces significant residual deformation and stress to the as-built parts, which increase manufacturing difficulty and geometrical inaccuracy as a result. The modified inherent strain (MIS) method exploiting multiscale process simulations was developed to simulate residual deformation accurately and efficiently. However, the existing procedure of implementing the MIS method is found to give inaccurate residual stress prediction. Here in this work, a new implementation procedure for the MIS method is proposed to improve the simulation accuracy of residual stress without degrading the residual deformation prediction. The new procedure concerns the application of inherent strains to the part-scale layer-by-layer finite element model to obtain residual stress and deformation field. While the existing implementation of the part-scale MIS model involves only mechanical properties at ambient temperature, the new procedure adds one more solution step employing mechanical properties at an elevated temperature determined from the inherent strain extraction step. Both numerical and experimental studies are conducted to validate the proposed new implementation procedure. It shows that by using the new procedure, the MIS-based simulation can predict both residual stress and deformation of as-built L-PBF metal parts with good accuracy.

36 MATERIALS SCIENCE↗

Improving the accuracy of energy baseline models for commercial buildings with occupancy data

More than 80% of energy is consumed during operation phase of a building's life cycle, so energy efficiency retrofit for existing buildings is considered a promising way to reduce energy use in buildings. The investment strategies of retrofit depend on the ability to quantify energy savings by “measurement and verification” (M&V), which compares actual energy consumption to how much energy would have been used without retrofit (called the “baseline” of energy use). Although numerous models exist for predicting baseline of energy use, a critical limitation is that occupancy has not been included as a variable. However, occupancy rate is essential for energy consumption and was emphasized by previous studies. This study develops a new baseline model which is built upon the Lawrence Berkeley National Laboratory (LBNL) model but includes the use of building occupancy data. The study also proposes metrics to quantify the accuracy of prediction and the impacts of variables. However, the results show that including occupancy data does not significantly improve the accuracy of the baseline model, especially for HVAC load. The reasons are discussed further. In addition, sensitivity analysis is conducted to show the influence of parameters in baseline models. To conclude, the results from this study can help us understand the influence of occupancy on energy use, improve energy baseline prediction by including the occupancy factor, reduce risks of M&V and facilitate investment strategies of energy efficiency retrofit.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancing predictive understanding and accuracy in geological carbon dioxide storage monitoring: Simulation and history matching of tracer transport dynamics

Co-injection of conservative tracers with carbon dioxide (CO 2 ) is a viable tool for monitoring subsurface processes during geological CO 2 storage (GCS). This research investigates the simulation and history-matching of a gas tracer (sulfur hexafluoride, SF 6 ) during CO 2 flooding, employing a core flooding result in Berea sandstone. Four extensively used saturation functions are assessed for their efficacy in history matching of CO 2 /SF 6 injection at the core scale. The history-matching process incorporates particle swarm optimization (PSO) to fine-tune constitutive relationships parameters. Next, employing transport models at the aquifer scale, we interrogate the impact on tracer transport and mixing of saturation function uncertainties, arising from the non-uniqueness of constitutive relationships parameters and saturation function types. To assess the effects of geological heterogeneity on behavior of tracer breakthrough curves (BTCs), we employ two normalized parameters assessing the degree of mixing and SF 6 breakthrough time. The aquifer-scale investigation encompasses both homogeneous and heterogeneous systems with and without capillary heterogeneity effects. Our findings underscore the critical importance of addressing saturation function uncertainties, emphasizing the significance of auxiliary experiments and innovative methodologies to enhance predictive accuracy. The findings highlight significant disparities in arrival times, BTC peaks, tails, and mixing levels, even under optimal conditions. Heterogeneity, with or without capillary heterogeneity, plays a crucial role in shaping BTC variations, resulting in accelerated SF 6 breakthrough times and reduced BTC peaks. Evaluation of monitoring points distant from the injector reveals a dampening effect on the SF6 BTC peak, particularly in heterogeneous systems with capillary heterogeneity, where the peak is halved. These insights underscore the challenges associated with tracer monitoring and the necessity for enhanced methodologies to improve predictive accuracy in subsurface processes during GCS.

58 GEOSCIENCES↗

Directional finite difference method for directly solving 3D gyrokinetic field equations with enhanced accuracy

The gyrokinetic (GK) field equation is a three-dimensional (3D) elliptic equation, but it is often simplified to a set of two-dimensional (2D) equations by assuming that the field does not vary along a specific direction. However, this simplification can introduce inevitable 0th-order numerical errors, as nonlinear mode coupling in toroidal geometry can produce undesirable harmonic modes that violate the assumption. In this work, we propose a novel directional finite difference method (FDM) with a local coordinate transformation to better resolve the target field of interest. The directional FDM can accurately solve 3D GK field equations without simplifications, which can overcome the limitations of conventional methods. The accuracy and efficiency of different FDMs are analyzed in great detail for a variety of geometries, from simple 2D Cartesian coordinates to realistic 3D curvilinear coordinates. The 0th-order numerical errors of simplified 2D GK equations were found to be more problematic for low-harmonic modes and low aspect ratio geometries such as spherical tokamaks. On the other hand, the directional 3D FDM can accurately resolve a much wider range of harmonic modes aligned to the direction of interest, including the low-harmonic modes. In conclusion, we demonstrate that the directional 3D FDM is a highly effective algorithm for solving the 3D GK field equations, achieving accuracy improvements of 10 to 100 times or more, particularly for low-harmonic modes in spherical tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accuracy of hourly energy predictions for demand flexibility applications

Decarbonization goals in the United States electricity sector are increasing the levels of renewable energy generation in the electricity supply system, and are driving increased attention to building electrification, which will increase the magnitude and shift the timing of the electricity system peak. These changes are motivating new approaches to coordinate building electricity demand with low-carbon renewable generation, elevating the importance of demand flexibility (DF) in buildings and the need to quantify the temporal impacts of DF. In this paper, we first characterize the hourly predictive accuracy of six commonly used baseline models in an application context of quantifying building-level load shift. Our analysis revealed insights such as hours of the day (afternoons), periods of the week (weekends), and seasons (summer) that were predicted with more accuracy than other time periods. In addition, the analysis showed tendencies toward overprediction or underprediction of load. Secondly, we provide the first published investigation of baseline erosion from repeated dispatch of building load shifting. We observed that as the baseline period is pushed back further from the prediction day, the distribution of errors across baseline model predictions increases, with notable inflection points near the three-week erosion point for two of the three models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Method for Assessing Ground-Truth Accuracy of the 5DCT Technique

Purpose: To develop a technique that assesses the accuracy of the breathing phase-specific volume image generation process by patient-specific breathing motion model using the original free-breathing computed tomographic (CT) scans as ground truths. Methods: Sixteen lung cancer patients underwent a previously published protocol in which 25 free-breathing fast helical CT scans were acquired with a simultaneous breathing surrogate. A patient-specific motion model was constructed based on the tissue displacements determined by a state-of-the-art deformable image registration. The first image was arbitrarily selected as the reference image. The motion model was used, along with the free-breathing phase information of the original 25 image datasets, to generate a set of deformation vector fields that mapped the reference image to the 24 nonreference images. The high-pitch helically acquired original scans served as ground truths because they captured the instantaneous tissue positions during free breathing. Image similarity between the simulated and the original scans was assessed using deformable registration that evaluated the pointwise discordance throughout the lungs. Results: Qualitative comparisons using image overlays showed excellent agreement between the simulated images and the original images. Even large 2-cm diaphragm displacements were very well modeled, as was sliding motion across the lung–chest wall boundary. The mean error across the patient cohort was 1.15 ± 0.37 mm, and the mean 95th percentile error was 2.47 ± 0.78 mm. Conclusion: The proposed ground truth–based technique provided voxel-by-voxel accuracy analysis that could identify organ-specific or tumor-specific motion modeling errors for treatment planning. Despite a large variety of breathing patterns and lung deformations during the free-breathing scanning session, the 5-dimensionl CT technique was able to accurately reproduce the original helical CT scans, suggesting its applicability to a wide range of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of the Frensley inflow boundary condition for Wigner equations in simulating resonant tunneling diodes

In this paper, the accuracy of the Frensley inflow boundary condition of the Wigner equation is analyzed in computing the I-V characteristics of a resonant tunneling diode (RTD). It is found that the Frensley inflow boundary condition for incoming electrons holds only exactly infinite away from the active device region and its accuracy depends on the length of contacts included in the simulation. For this study, the non-equilibrium Green's function (NEGF) with a Dirichlet to Neumann mapping boundary condition is used for comparison. The I-V characteristics of the RTD are found to agree between self-consistent NEGF and Wigner methods at low bias potentials with sufficiently large GaAs contact lengths. Finally, the relation between the negative differential conductance (NDC) of the RTD and the sizes of contact and buffer in the RTD is investigated using both methods.

97 MATHEMATICS AND COMPUTING↗