Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Fixed-target serial crystallography at the Structural Biology Center

Serial synchrotron crystallography enables the study of protein structures under physiological temperature and reduced radiation damage by collection of data from thousands of crystals. The Structural Biology Center at Sector 19 of the Advanced Photon Source has implemented a fixed-target approach with a new 3D-printed mesh-holder optimized for sample handling. The holder immobilizes a crystal suspension or droplet emulsion on a nylon mesh, trapping and sealing a near-monolayer of crystals in its mother liquor between two thin Mylar films. Data can be rapidly collected in scan mode and analyzed in near real-time using piezoelectric linear stages assembled in an XYZ arrangement, controlled with a graphical user interface and analyzed using a high-performance computing pipeline. Here, the system was applied to two β-lactamases: a class D serine β-lactamase from Chitinophaga pinensis DSM 2588 and L1 metallo-β-lactamase from Stenotrophomonas maltophilia K279a.

59 BASIC BIOLOGICAL SCIENCES↗

Sample-minimizing co-flow cell for time-resolved pump–probe X-ray solution scattering

A fundamental problem in biological sciences is understanding how macromolecular machines work and how the structural changes of a molecule are connected to its function. Time-resolved techniques are vital in this regard and essential for understanding the structural dynamics of biomolecules. Time-resolved small- and wide-angle X-ray solution scattering has the capability to provide a multitude of information about the kinetics and global structural changes of molecules under their physiological conditions. However, standard protocols for such time-resolved measurements often require significant amounts of sample, which frequently render time-resolved measurements impossible. A cytometry-type sheath co-flow cell, developed at the BioCARS 14-ID beamline at the Advanced Photon Source, USA, allows time-resolved pump–probe X-ray solution scattering measurements to be conducted with sample consumption reduced by more than ten times compared with standard sample cells and protocols. The comparative capabilities of the standard and co-flow experimental setups were demonstrated by studying time-resolved signals in photoactive yellow protein.

36 MATERIALS SCIENCE↗

Mapping nanocrystal orientations via scanning Laue diffraction microscopy for multi-peak Bragg coherent diffraction imaging

The recent commissioning of a movable monochromator at the 34-ID-C endstation of the Advanced Photon Source has vastly simplified the collection of Bragg coherent diffraction imaging (BCDI) data from multiple Bragg peaks of sub-micrometre scale samples. Laue patterns arising from the scattering of a polychromatic beam by arbitrarily oriented nanocrystals permit their crystal orientations to be computed, which are then used for locating and collecting several non-co-linear Bragg reflections. The volumetric six-component strain tensor is then constructed by combining the projected displacement fields that are imaged using each of the measured reflections via iterative phase retrieval algorithms. Complications arise when the sample is heterogeneous in composition and/or when multiple grains of a given lattice structure are simultaneously illuminated by the polychromatic beam. Here, a workflow is established for orienting and mapping nanocrystals on a substrate of a different material using scanning Laue diffraction microscopy. The capabilities of the developed algorithms and procedures with both synthetic and experimental data are demonstrated. The robustness is verified by comparing experimental texture maps obtained with Laue diffraction microscopy at the beamline with maps obtained from electron back-scattering diffraction measurements on the same patch of gold nanocrystals. Such tools provide reliable indexing for both isolated and densely distributed nanocrystals, which are challenging to image in three dimensions with other techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

Cloning, expression, purification, crystallization and preliminary X-ray diffraction analysis of macrophage growth locus A (MglA) protein from Francisella tularensis

Francisella tularensis, a potential bioweapon, causes a rare infectious disease called tularemia in humans and animals. The macrophage growth locus A (MglA) protein from F. tularensis associates with RNA polymerase to positively regulate the expression of multiple virulence factors that are required for its survival and replication within macrophages. The MglA protein was overproduced in Escherichia coli, purified and crystallized. The crystals diffracted to 7.5 {angstrom} resolution at the Advanced Photon Source, Argonne National Laboratory and belonged to the hexagonal space group P6{sub 1} or P6{sub 5}, with unit-cell parameters a = b = 125, c = 54 {angstrom}.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Crystal structure solution and high-temperature thermal expansion in NaZr 2 (PO 4 ) 3 -type materials

The NaZr 2 P 3 O 12 family of materials have shown low and tailorable thermal expansion properties. In this study, SrZr 4 P 6 O 24 (SrO·4ZrO 2 ·3P 2 O 5 ), CaZr 4 P 6 O 24 (CaO·4ZrO 2 ·3P 2 O 5 ), MgZr 4 P 6 O 24 (MgO·4ZrO 2 ·3P 2 O 5 ), NaTi 2 P 3 O 12 [½(Na 2 O·4TiO 2 ·3P 2 O 5 )], NaZr 2 P 3 O 12 [½(Na 2 O·4ZrO 2 ·3P 2 O 5 )], and related solid solutions were synthesized using the organic–inorganic steric entrapment method. The samples were characterized by in-situ high-temperature X-ray diffraction from 25 to 1500°C at the Advanced Photon Source and National Synchrotron Light Source II. The average linear thermal expansion of SrZr 4 P 6 O 24 and CaZr 4 P 6 O 24 was between −1 × 10 −6 per °C and 6 × 10 −6 per °C from 25 to 1500°C. The crystal structures of the high-temperature polymorphs of CaZr 4 P 6 O 24 and SrZr 4 P 6 O 24 with R 3 c symmetry were solved by Fourier difference mapping and Rietveld refinement. This polymorph is present above ∼1250°C. This work measured thermal expansion coefficients to 1500°C for all samples and investigated the differences in thermal expansion mechanisms between polymorphs and between compositions.

36 MATERIALS SCIENCE↗

Increased Throughput and Sensitivity of Synchrotron-Based Characterization for Photovoltaic Materials

Optimizing photovoltaic (PV) devices requires characterization and optimization across several length scales, from centimeters to nanometers. Synchrotron-based micro-X-ray fluorescence spectromicroscopy (μ-XRF) is a valuable link in the PV-related material and device characterization suite. μ-XRF maps of elemental distributions in PV materials have high spatial resolution and excellent sensitivity and can be measured on absorber materials and full devices. Recently, we implemented on-the-fly data collection (flyscan) at Beamline 2-ID-D at the Advanced Photon Source at Argonne National Laboratory, eliminating a 300 ms per-pixel overhead time. This faster scanning enables high-sensitivity (~10 14 atoms/cm 2 ), large-area (10 000s of μm 2 ), high-spatial resolution (<;200 nm scale) maps to be completed within a practical scanning time. We specifically show that when characterizing detrimental trace metal precipitate distributions in multicrystalline silicon wafers for PV, flyscans can increase the productivity of μ-XRF by an order of magnitude. Additionally, flyscan μ-XRF mapping enables relatively large-area correlative microscopy. As an example, we map the transition metal distribution in a 50 μm-diameter laser-fired contact of a silicon solar cell before and after lasing. As a result, while we focus on μ-XRF of mc-Si wafers for PV, our results apply broadly to synchrotron-based mapping of PV absorbers and devices.

14 SOLAR ENERGY↗

Optimizing Floating Guard Ring Designs for FASPAX N-in-P Silicon Sensors

FASPAX (Fermi-Argonne Semiconducting Pixel Array X-ray detector) is being developed as a fast integrating area detector with wide dynamic range for time resolved applications at the upgraded Advanced Photon Source (APS.) A burst mode detector with intended $\mbox{13 $MHz$}$ image rate, FASPAX will also incorporate a novel integration circuit to achieve wide dynamic range, from single photon sensitivity to $10^{\text{5}}$ x-rays/pixel/pulse. To achieve these ambitious goals, a novel silicon sensor design is required. This paper will detail early design of the FASPAX sensor. Results from TCAD optimization studies, and characterization of prototype sensors will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Short-Period Nb 3 Sn Superconducting Planar Undulators

NbTi-based superconducting undulators (SCUs) have been developed and proven to increase the brightness by an order of magnitude at high X-ray energies at the ANL's Advanced Photon Source (APS). Nb 3 Sn has the potential to further enhance the performance of SCUs. A new project, aiming to fabricate a full-length, 3-m-long Nb 3 Sn SCU, compatible with the storage ring, has started at the APS. To develop the technology, three Nb 3 Sn short prototype magnets were fabricated and tested in liquid helium. These prototypes were used to incrementally improve the original design. The final short model magnet reached 100% of the short sample limit. Here, the achieved current level in this magnet is 75% higher than what an NbTi wire can deliver.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Analysis of a Helical Superconducting Undulator Cryostat

A novel cryocooler-cooled helical superconducting undulator (HSCU) was built and installed in the Advanced Photon Source (APS) storage ring and has been in operation since January 2018. The new cryostat for the HSCU is a major improvement of the cryogenic system used for the existing APS planar superconducting undulators. In both systems, superconducting magnets are cooled independently from the beam chamber by liquid helium (LHe) passing through a channel in the magnet/mold assembly. The original planar undulator cryostat consists of three thermal circuits: the outer shield circuit to cool both the warm part of the magnet current leads and the outer shield, the beam chamber cooling circuit to cool the beam chamber and the inner shield, and the magnet cooling circuit to cool the magnets and the LHe tank. On the other hand, the new system consists of only two thermal circuits: the thermal shield circuit to cool the beam chamber, the shield, and the warm part of the magnet leads; and the magnet cooling circuit to cool the LHe tank and the magnet/mold assembly. An finite element analysis-based thermal model of the new HSCU cryostat was developed while the cryogenic performance of the HSCU was measured in a series of standalone tests as well as after installation in the storage ring. This paper presents a thermal analysis of the new HSCU cryostat and, in particular, a comparison of calculated and measured temperatures as well as the excess cooling capacity of the new cryostat in static and dynamic (beam-induced heating) modes.

cryocooler↗

Conceptual Design of a Conduction-Cooled Superconducting Undulator

In superconducting undulators (SCUs) that are currently operating at the Advanced Photon Source, the undulator magnets are indirectly cooled with liquid helium penetrating through channels in the magnet cores. The liquid helium is stored in a tank that is cooled by cryocoolers. However, a cryogen-free version of a superconducting undulator in which the undulator magnets are conduction-cooled is also possible, as has been realized in the SCUs developed at ANKA. We are currently working on a conceptual design of a conduction-cooled planar superconducting undulator. The measured load lines of cryocoolers and the measured thermal conductance of various thermal links are used in the thermal analysis. Also, various materials for the undulator magnet cores are being considered. This paper reports the thermal design of a conduction-cooled planar SCU.

cryocooler↗

Fabrication and Testing of 18-mm-Period, 0.5-m-Long Nb 3 Sn Superconducting Undulator

The Advanced Photon Source at Argonne National Laboratory, in collaboration with FNAL and LBNL, is developing a Nb 3 Sn superconducting undulator with the goal of installing this device on the APS storage ring and providing APS users with the novel radiation source. A series of short, similar to ~ 8-cm-long, 18-mm-period undulator prototype magnets have been designed, fabricated, and tested. The same design was scaled to fabricate a 0.5-m-long undulator prototype. Tests of this prototype showed that the designed peak magnetic field of 1.2 T at 850 A was successfully achieved. It represents at least a 20% improvement in comparison with a NbTi SCU having the same period and magnetic gap. Test results and lessons learned from the design process are reported here.

43 PARTICLE ACCELERATORS↗

A Preliminary Thermal Model of the LHe-based SCAPE Cryostat

The SCAPE (SuperConducting Arbitrarily Polarizing Emitter) undulator is under development at the Advanced Photon Source (APS). This new undulator requires a cryostat that will be designed based on expected heat loads. For instance, the expected heating of the beam chamber by electron beam is estimated to be at a level of 182 W – much higher than in planar SCUs. This and other challenges require careful thermal analysis of the LHe-based SCAPE cryostat. A detailed thermal model of the LHe-based SCAPE cryostat has been created in ANSYS. This paper presents calculated cooling capacity and temperatures of the SCAPE cryostat for the static and dynamic heat loads. Index Terms—SCAPE (SuperConducting Arbitrarily Polarizing Emitter), cryocooler, LHe, thermal isolation, thermal conductance.

Shiroyanagi, Y.↗

Design, Construction, and Testing of 0.5-m, 18-mm Period Nb 3 Sn Superconducting Undulator Magnets

We report design and fabrication of a new Nb 3 Sn-based superconducting undulator (SCU) are underway at the Advanced Photon Source (APS) of Argonne National Laboratory in collaboration with Fermilab and Lawrence Berkeley National Laboratory. To develop a robust and reliable fabrication process, the magnet development consists of several steps. First, magnetic and mechanical simulations were performed to optimize the magnet design; then, the design matured further by fabricating and testing a series of very short prototypes, ~8 cm long with a period length of 18 mm. These short prototype studies were previously reported. Second, the design was scaled to an intermediate length of ~0.5 m. These two steps led to the final design of ~1.1–m-long magnets, which are currently being fabricated. The quench behavior of each 0.5-m-long undulator magnet, as well as undulator assemblies from these magnets, was studied. The first SCU magnet assembly did not meet the design specifications due to the breakdown of the insulation. With an improved design and fabrication process based on lessons learned, the second SCU assembly achieved the design undulator field of 1.2 T. The design was further optimized, and the third set of magnets was fabricated and successfully tested.

43 PARTICLE ACCELERATORS↗

Cryogenic System Preliminary Design for a 0.5m-Long, Conduction-Cooled Nb3Sn Undulator Magnet Prototype

There are several NbTi superconducting undulator (SCU) magnets currently in operation at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The development on Nb3Sn-based superconducting undulator magnets at APS is underway due to the potential to further enhance the performance of the SCUs. Superconducting undulator magnets need to keep temperature gradients minimized in order to retain thermal and operating current margin. We have designed the thermal links for efficient heat conduction using 3D finite element analysis (FEA) simulation in COMSOL Multiphysics software, which was later used for the calculation of the temperature distribution across a 0.5 m long, conduction-cooled, Nb3Sn undulator magnet prototype that includes both conductive heat transfer and radiative heating components. We have modelled the evolution of the thermal properties of the magnet winding as well as other cold parts during cool-down from ambient temperature with the operation of a SHI RDK-415D cryocooler to examine the estimated time that is needed for the cooldown as well as the baseline temperature we could achieve. A key result was that a maximum coil delta T = 0.11 K along the designed thermal links and a temperature range of 3.42 K-3.53 K for the winding were predicted at steady state. A pair of G10 support rods for carrying the magnet as well as a pair of current leads made of metals were also designed and optimized for the testing system, targeting for an operation temperature of 4 K and a coil current of 950 A DC.

Zhang, Danlu↗

Quench Behavior of 18-mm-Period, 1.1-m-Long Nb 3 Sn Undulator Magnets

A novel Nb 3 Sn-based superconducting undulator (SCU) was developed and integrated into the Advanced Photon Source (APS) at Argonne National Laboratory. The SCU achieved user operation within an accelerator environment. Compared to its Nb-Ti counterpart, the Nb 3 Sn SCU operates at substantially higher currents. Thus, a detailed experimental evaluation of the SCU magnets’ performance was necessary under both “wet” and indirectly cooled conditions to ensure its reliability during operation. Here our study indicated that the cooling method has a noticeable influence on the magnet's behavior. Specifically, energy dissipation in the magnets during quenches was observed to be greater under indirect cooling than with “wet” cooling. This investigation provided insights into the safe operational limits. Guided by these insights the more challenging high-current tests were successfully carried out at the end of the user phase. The SCU achieved the design undulator field of 1.17 T at 820 A and 4.2 K, with a magnetic gap of 9.5 mm and a period of 18 mm. Actual performance exceeded the specifications, reaching 850 A.

43 PARTICLE ACCELERATORS↗