Search NASA⌕ Search

SEARCH · Search NASA

Results for “Algorithm Development and Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Precision Environmental Radiation Monitoring System

A new precision low-level environmental radiation monitoring system has been developed and tested at Jefferson Lab. This system provides environmental radiation measurements with accuracy and stability of the order of 1 nGy/h in an hour, roughly corresponding to approximately 1% of the natural cosmic background at the sea level. Advanced electronic front-end has been designed and produced for use with the industry-standard High Pressure Ionization Chamber detector hardware. A new highly sensitive readout electronic circuit was designed to measure charge from the virtually suspended ionization chamber ion collecting electrode. New signal processing technique and dedicated data acquisition were tested together with the new readout. The designed system enabled data collection in a remote Linux-operated computer workstation, which was connected to the detectors using a standard telephone cable line. The data acquisition system algorithm is built around the continuously running 24-bit resolution 192 kHz data sampling analog to digital convertor. The major features of the design include: extremely low leakage current in the input circuit, true charge integrating mode operation, and relatively fast response to the intermediate radiation change. These features allow operating of the device as an environmental radiation monitor, at the perimeters of the radiation-generating installations in densely populated areas, like in other monitoring and security applications requiring high precision and long-term stability. Initial system evaluation results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Moving Voxel Image Reconstruction (MVIR) Method in the Fixed Site Detection System (FSDS) Prototype

We have developed a dynamic image reconstruction method called MVIR (Moving Voxel Image Reconstruction) for lane detection in multilane portal monitor systems. MVIR was evaluated for use in the Fixed Site Detection System, a prototype three-lane portal monitor system for EZ-pass toll plazas. As a baseline, we compared MVIR with a static image reconstruction method in analyzing the same real and simulated data sets. Performance was judged by the distributions of image intensities for source and no-source vehicles over many trials as a function of source strength. We found that MVIR produced significantly better results in all cases. The performance difference was greatest at low count rates, where source/no-source distributions were well separated with the MVIR method, allowing reliable source vehicle identification with a low probability of false positive identifications. Static reconstruction of the same data produced overlapping distributions that made source vehicle identification unreliable. The performance of the static method was acceptable at high count rates. Both algorithms reliably identified two strong sources passing through at nearly the same time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the Impact of Radiation on Cameras and Robotic Perception - 19242

Robotic systems are increasingly used for inspection, maintenance, and disaster assistance for nuclear power plants. These robots utilize increasingly high levels of autonomy to operate in environments that are unsafe for humans to operate the robot in or require more precise control over the robot than a human can offer. In these cases, the robot must include perception and computation components to autonomously sense and navigate through the environment to fulfill its mission. This difficult task is complicated by radiation interfering with sensors' operation. The impact of this interference is largely unexplored, as existing works on radiation interference on sensors focus on estimating the incident radiation, rather than how it impacts a robotic system using the sensor. In this work, we seek to quantify and describe the impact of radiation on cameras, and how the radiation affects robotic performance. In this paper we study cameras that are suitable for small, lightweight unmanned aerial vehicles (UAVs) that are increasingly deployed to fly in confined areas in emergencies, where the surrounding environment is unsafe for workers to operate. These small UAVs lack the payload capacity to carry significant radiation shielding, so any onboard sensors will be affected by radiation. In the case of cameras, this radiation appears as noise in the camera imagery. This noise will interfere with the UAV's operation, by obscuring obstacles and interfering with localization and optical flow algorithms that detect detailed features in the environment. To date, there is a lack of information on how the radiation noise in the camera image impacts the overall robot system performance Existing work focuses on estimating the amount of incident radiation by measuring the corruption in the images. However, these works suffer several shortcomings for robotic systems. First, a robot must be able to successfully navigate its environment during a successful mission, and merely quantifying the amount of radiation noise in an image does not adequately explain how it may interfere with higher level navigation and perception tasks. Second, radiation estimation procedures rely on focusing the camera on a known and static background. This is unsuitable for robotic exploration tasks, where the robot frequently moves around an unknown environment that may be dynamically changing. Our work contains two contributions that address these shortcomings. First, we conduct a detailed analysis of the noise radiation causes in cameras by exposing cameras that are commonly used on UAVs [e.g., small form factor complementary metal-oxide-semiconductor (CMOS) cameras] to varying levels of radiation that may be present in emergency scenarios. From this exposure, we quantify not only how much noise is present, but quantify its appearance. By quantifying the appearance and amount of noise in a camera image, researchers can design mitigation strategies for the corruption, so that their robotic systems can operate in these challenging environments. Second, we demonstrate how to leverage this experimental data in robotic simulations. Using data from the first set of experiments allows us to test and verify the robots in simulation. Using simulators allows us to verify the robots will perform as expected during critical times without needing expensive test equipment or damaging valuable robot prototypes. Other researchers using robots for exploration of irradiated environments will benefit from our research by incorporating similar noise models in their research. 1 Southwest Research Institute{sup R} is a registered trademark of Southwest Research Institute in the United States and/or other countries. This will increase the reliability of robotic systems prior to deployment in emergency situations, which will in turn increase their effectiveness and speed the development of robots that would otherwise need expensive and time-consuming test procedures to validate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An algorithm to estimate the object support in truncated images

Purpose: Truncation artifacts in CT occur if the object to be imaged extends past the scanner field of view (SFOV). These artifacts impede diagnosis and could possibly introduce errors in dose plans for radiation therapy. Several approaches exist for correcting truncation artifacts, but existing correction algorithms do not accurately recover the skin line (or support) of the patient, which is important in some dose planning methods. The purpose of this paper was to develop an iterative algorithm that recovers the support of the object. Methods: The authors assume that the truncated portion of the image is made up of soft tissue of uniform CT number and attempt to find a shape consistent with the measured data. Each known measurement in the sinogram is interpreted as an estimate of missing mass along a line. An initial estimate of the object support is generated by thresholding a reconstruction made using a previous truncation artifact correction algorithm (e.g., water cylinder extrapolation). This object support is iteratively deformed to reduce the inconsistency with the measured data. The missing data are estimated using this object support to complete the dataset. The method was tested on simulated and experimentally truncated CT data. Results: The proposed algorithm produces a better defined skin line than water cylinder extrapolation. On the experimental data, the RMS error of the skin line is reduced by about 60%. For moderately truncated images, some soft tissue contrast is retained near the SFOV. As the extent of truncation increases, the soft tissue contrast outside the SFOV becomes unusable although the skin line remains clearly defined, and in reformatted images it varies smoothly from slice to slice as expected. Conclusions: The support recovery algorithm provides a more accurate estimate of the patient outline than thresholded, basic water cylinder extrapolation, and may be preferred in some radiation therapy applications.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-04: Ultrafast Cone-Beam CT Scatter Correction with GPU-Based Monte Carlo Simulation

Purpose: Scatter artifacts severely degrade image quality of cone-beam CT (CBCT). We present an ultrafast scatter correction framework by using GPU-based Monte Carlo (MC) simulation and prior patient CT image, aiming at automatically finish the whole process including both scatter correction and reconstructions within 30 seconds. Methods: The method consists of six steps: 1) FDK reconstruction using raw projection data; 2) Rigid Registration of planning CT to the FDK results; 3) MC scatter calculation at sparse view angles using the planning CT; 4) Interpolation of the calculated scatter signals to other angles; 5) Removal of scatter from the raw projections; 6) FDK reconstruction using the scatter-corrected projections. In addition to using GPU to accelerate MC photon simulations, we also use a small number of photons and a down-sampled CT image in simulation to further reduce computation time. A novel denoising algorithm is used to eliminate MC scatter noise caused by low photon numbers. The method is validated on head-and-neck cases with simulated and clinical data. Results: We have studied impacts of photo histories, volume down sampling factors on the accuracy of scatter estimation. The Fourier analysis was conducted to show that scatter images calculated at 31 angles are sufficient to restore those at all angles with <0.1% error. For the simulated case with a resolution of 512×512×100, we simulated 10M photons per angle. The total computation time is 23.77 seconds on a Nvidia GTX Titan GPU. The scatter-induced shading/cupping artifacts are substantially reduced, and the average HU error of a region-of-interest is reduced from 75.9 to 19.0 HU. Similar results were found for a real patient case. Conclusion: A practical ultrafast MC-based CBCT scatter correction scheme is developed. The whole process of scatter correction and reconstruction is accomplished within 30 seconds. This study is supported in part by NIH (1R01CA154747-01), The Core Technology Research in Strategic Emerging Industry, Guangdong, China (2011A081402003)

60 APPLIED LIFE SCIENCES↗

WE-G-18A-03: Cone Artifacts Correction in Iterative Cone Beam CT Reconstruction

Purpose: For iterative reconstruction (IR) in cone-beam CT (CBCT) imaging, data truncation along the superior-inferior (SI) direction causes severe cone artifacts in the reconstructed CBCT volume images. Not only does it reduce the effective SI coverage of the reconstructed volume, it also hinders the IR algorithm convergence. This is particular a problem for regularization based IR, where smoothing type regularization operations tend to propagate the artifacts to a large area. It is our purpose to develop a practical cone artifacts correction solution. Methods: We found it is the missing data residing in the truncated cone area that leads to inconsistency between the calculated forward projections and measured projections. We overcome this problem by using FDK type reconstruction to estimate the missing data and design weighting factors to compensate the inconsistency caused by the missing data. We validate the proposed methods in our multi-GPU low-dose CBCT reconstruction system on multiple patients' datasets. Results: Compared to the FDK reconstruction with full datasets, while IR is able to reconstruct CBCT images using a subset of projection data, the severe cone artifacts degrade overall image quality. For head-neck case under a full-fan mode, 13 out of 80 slices are contaminated. It is even more severe in pelvis case under half-fan mode, where 36 out of 80 slices are affected, leading to inferior soft-tissue delineation. By applying the proposed method, the cone artifacts are effectively corrected, with a mean intensity difference decreased from ∼497 HU to ∼39HU for those contaminated slices. Conclusion: A practical and effective solution for cone artifacts correction is proposed and validated in CBCT IR algorithm. This study is supported in part by NIH (1R01CA154747-01)

60 APPLIED LIFE SCIENCES↗

Knowledge based ranking algorithm for comparative assessment of post-closure care needs of closed landfills

Post-closure care (PCC) activities at landfills include cap maintenance; water quality monitoring; maintenance and monitoring of the gas collection/control system, leachate collection system, groundwater monitoring wells, and surface water management system; and general site maintenance. The objective of this study was to develop an integrated data and knowledge based decision making tool for preliminary estimation of PCC needs at closed landfills. To develop the decision making tool, 11 categories of parameters were identified as critical areas which could affect future PCC needs. Each category was further analyzed by detailed questions which could be answered with limited data and knowledge about the site, its history, location, and site specific characteristics. Depending on the existing knowledge base, a score was assigned to each question (on a scale 1-10, as 1 being the best and 10 being the worst). Each category was also assigned a weight based on its relative importance on the site conditions and PCC needs. The overall landfill score was obtained from the total weighted sum attained. Based on the overall score, landfill conditions could be categorized as critical, acceptable, or good. Critical condition indicates that the landfill may be a threat to the human health and the environment and necessary steps should be taken. Acceptable condition indicates that the landfill is currently stable and the monitoring should be continued. Good condition indicates that the landfill is stable and the monitoring activities can be reduced in the future. The knowledge base algorithm was applied to two case study landfills for preliminary assessment of PCC performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model

Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow. From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing Long-term Monitoring of Radiation Air Dose Rates - 19169

Radiation air dose rates near the Fukushima Daiichi Nuclear Power Plant (NPP) have been steadily decreasing over the past seven years since the accident in March 2011. After seven years, the radiation monitoring program is expected to transition from short-term emergency responses to long-term monitoring. The objectives of long-term monitoring are often different from early emergency responses, since extensive data accumulation has led to an understanding of contaminant distributions and mobility. The main long-term monitoring objectives are (1) to confirm system stability and the continuing reduction of contaminant and hazard levels, (2) to provide assurance for the public, (3) to accumulate the basic datasets for scientific knowledge and future preparation, and (4) to detect changes or anomalies in contaminant mobility (if they occur), or any unexpected processes or events. In this work, we have developed a methodology for optimizing the sampling locations of radiation air dose-rate monitoring. Three steps are taken in order to determine sampling locations in a systematic manner: (1) prioritizing the critical locations, such as schools or regulatory requirement locations, (2) diversifying locations across the key environmental controls that are known to influence contaminant mobility and distributions, and (3) capturing the heterogeneity of radiation air dose rates across the domain. In the second step, we use a Gaussian mixture model to identify the representative locations in multiple environmental variables, such as elevation and land-cover types. In the third step, we use a Gaussian process model to capture and estimate the heterogeneity of air dose rates across the domain. We use the integrated dose-rate map from the Bayesian geostatistical method as the reference map and distribute the sampling in such a way as to capture the heterogeneity of the reference map. Although we assume hypothetical sets of measurement locations to evaluate the performance of the methodology and algorithms, we have demonstrated this approach using real, spatially extensive datasets, including the integrated air-dose-rate map of 2016. Our results have shown that this approach allows us to add sampling locations in a systematic manner. Increasing the number of sampling locations can better capture the heterogeneity of dose rates, although the estimation error does not decrease further after a certain number of samples. We have also found that when there are restrictions such as pre-existing monitoring locations or the ones along roads, the spatial estimation becomes poor even with the same number of monitoring locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unsupervised data mining in nanoscale x-ray spectro-microscopic study of NdFeB magnet

Novel developments in X-ray based spectro-microscopic characterization techniques have increased the rate of acquisition of spatially resolved spectroscopic data by several orders of magnitude over what was possible a few years ago. This accelerated data acquisition, with high spatial resolution at nanoscale and sensitivity to subtle differences in chemistry and atomic structure, provides a unique opportunity to investigate hierarchically complex and structurally heterogeneous systems found in functional devices and materials systems. However, handling and analyzing the large volume data generated poses significant challenges. Here we apply an unsupervised data-mining algorithm known as DBSCAN to study a rare-earth element based permanent magnet material, Nd 2 Fe 14 B. We are able to reduce a large spectro-microscopic dataset of over 300,000 spectra to 3, preserving much of the underlying information. Scientists can easily and quickly analyze in detail three characteristic spectra. Our approach can rapidly provide a concise representation of a large and complex dataset to materials scientists and chemists. For instance, it shows that the surface of common Nd 2 Fe 14 B magnet is chemically and structurally very different from the bulk, suggesting a possible surface alteration effect possibly due to the corrosion, which could affect the material’s overall properties.

36 MATERIALS SCIENCE↗

RadTrac : A system for detecting, localizing, and tracking radioactive sources in real time.

Within the homeland security and emergency response communities, there is a need for a low-profile system to detect and locate radioactive sources. RadTrac has been developed at Argonne National Laboratory as an integrated system for the detection, localization, identification, and tracking of radioactive sources in real time. The system is based on a network of radiation detectors and advanced signal-processing algorithms. Features include video surveillance, automated tracking, easy setup, and logging of all data and images. This paper describes the advanced algorithms that were developed and implemented for source detection, localization, and tracking in real time. In the physio-spatial integration approach to source localization, counts from multiple detectors are processed according to the underlying physics linking these counts to obtain the probability that a source is present at any point in space. This information is depicted in a probability density function map. This type of depiction allows the results to be presented in a simple, easy-to-understand manner. It also allows for many different complicated factors to be accounted for in a single image as each factor is computed as a probability density in space. These factors include spatial limitations, variable shielding, directional detectors, moving detectors, and different detector sizes and orientations. The utility and versatility of this approach is described in further detail. Advanced signal-processing algorithms have also been incorporated to improve real-time tracking and to increase signal-to-noise ratios including temporal linking and energy binning. Measurements aimed at demonstrating the sensitivity improvements through the use of advanced signal-processing techniques were performed and are presented. Results of tracking weak sources (<100 {micro}Ci {sup 137}Cs) using four fixed-position detectors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components (Final Technical Report)

Metal Additive Manufacturing (AM) is a promising method for cost-efficient fabrication of complex shape structures for applications in harsh environment, such as in a nuclear reactor. However, internal defects (pores) occur in high-strength AM alloys, which are manufactured with Laser Powder Bed Fusion (LPBF) AM method. Pulsed Infrared Thermography (PIT) is an efficient nondestructive evaluation (NDE) method to examine actual structures, because this method offers one-sided non-contact measurements, and fast processing of large sample areas. However, imaging of material defects, particularly defects with sizes at microscopic level, is challenging. In this report, we benchmark the performance of several Unsupervised Learning (UL) algorithms designed to enhance imaging of microscopic defects in metals with PIT. UL aims to learn the latent principal patterns (dictionaries) in PIT data to detect defects with minimal human supervision. Performance of Independent Component Analysis (ICA), Sparse Coding (SC), Principal Component Analysis (PCA) and Exploratory Factor Analysis (EFA) was compared using F-score, UL model training time and defects reconstruction time. We obtained the average F-score of 0.75, and a highest F-score of 0.89 for the EFA algorithm. Overall, EFA outperforms other UL algorithms considered in this study. In another approach, we investigate Thermal Tomography (TT), which is a computational method for reconstruction of depth profile of internal material defects from PIT nondestructive evaluation (NDE). TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of subsurface internals defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. Performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shape imported from scanning electron microscopy (SEM) images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on TT images of elliptical defects is capable of classifying shape and orientation of irregular defects. Training the CNN on irregular defect shapes instead of on elliptical shapes would make the resulting classifications more descriptive of actual defect shapes. However, this requires a much higher volume of SEM images of material defects, which are difficult to obtain because of random occurrence of defects in LPBF. To address this challenge, we developed a generative adversarial network (GAN) to augment the existing dataset of SEM defect images. The GAN model is demonstrated to create novel yet realistic defect shapes that can be used as input for simulated PTT images to train CNN. We also investigate several approaches based on Gaussian Random Circle and Bezier Curves for constructing parametric models of irregular-shape defects.

36 MATERIALS SCIENCE↗

Prostate brachytherapy postimplant dosimetry: Automatic plan reconstruction of stranded implants

Purpose: Plan reconstruction for permanent implant prostate brachytherapy is the process of determining the correspondence between planned and implanted seeds in postimplant analysis. Plan reconstruction informs many areas of brachytherapy quality assurance, including the verification of seed segmentation, misplacement and migration assessment, implant simulations, and the dosimetry of mixed-activity or mixed-species implants. Methods: An algorithm has been developed for stranded implants which uses the interseed spacing constraints imposed by the suture to improve the accuracy of reconstruction. Seventy randomly selected clinical cases with a mean of 23.6 (range 18-30) needles and mean density of 2.0 (range 1.6-2.6) 2.0 (range 1.6-2.6) seeds/cm{sup 3} were automatically reconstructed and the accuracy compared to manual reconstructions performed using a custom 3D graphical interface. Results: Using the automatic algorithm, the mean accuracy of the assignment relative to manual reconstruction was found to be 97.7{+-}0.5%. Fifty-two of the 70 cases (74%) were error-free; of seeds in the remaining cases, 96.7{+-}0.3% were found to be attributed to the correct strand and 97.0{+-}0.3% were correctly connected to their neighbors. Any necessary manual correction using the interface is usually straightforward. For the clinical data set tested, neither the number of seeds or needles, average density, nor the presence of clusters was found to have an effect on reconstruction accuracy using this method. Conclusions: Routine plan reconstruction of stranded implants can be performed with a high degree of accuracy to support postimplant dosimetry and quality analyses.

60 APPLIED LIFE SCIENCES↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗

Analysis of the scintillation mechanism in a pressurized {sup 4}He fast neutron detector using pulse shape fitting

An empirical investigation of the scintillation mechanism in a pressurized {sup 4}He gas fast neutron detector was conducted using pulse shape fitting. Scintillation signals from neutron interactions were measured and averaged to produce a single generic neutron pulse shape from both a {sup 252}Cf spontaneous fission source and a (d,d) neutron generator. An expression for light output over time was then developed by treating the decay of helium excited states in the same manner as the decay of radioactive isotopes. This pulse shape expression was fitted to the measured neutron pulse shape using a least-squares optimization algorithm, allowing an empirical analysis of the mechanism of scintillation inside the {sup 4}He detector. A further understanding of this mechanism in the {sup 4}He detector will advance the use of this system as a neutron spectrometer. For {sup 252}Cf neutrons, the triplet and singlet time constants were found to be 970 ns and 686 ns, respectively. For neutrons from the (d,d) generator, the time constants were found to be 884 ns and 636 ns. Differences were noted in the magnitude of these parameters compared to previously published data, however the general relationships were noted to be the same and checked with expected trends from theory. Of the excited helium states produced from a {sup 252}Cf neutron interaction, 76% were found to be born as triplet states, similar to the result from the neutron generator of 71%. The two sources yielded similar pulse shapes despite having very different neutron energy spectra, validating the robustness of the fits across various neutron energies.

36 MATERIALS SCIENCE↗

Study of Heavy Flavor Mesons and Flavor-Tagged Jets with the CMS Detector

The goal of this research program is to implement heavy flavor meson triggers in heavy-ion collisions for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, including algorithm design, timing studies, offline validation, and online performance monitoring. The physics analyses which can be achieved by data from these new triggers is to address one of the most important questions in the field: parton flavor dependence of jet-quenching for the understanding of the transport properties of the Quark-Gluon Plasma. This program will allow CMS to collect the highest statistics heavy flavor meson and jet data ever recorded in heavy-ion colliders. The program includes two objectives: (1) Build and maintain the heavy flavor meson and jet triggers for heavy-ion collisions and deploy the trigger algorithms for 2015-2018 PbPb and pPb run at the LHC; (2) Perform heavy flavor meson and jet physics analyses, which can be used to study the parton flavor dependence of jet quenching, to extract the elastic energy loss coefficient of the QGP, and to test whether massive quarks also participate in collective expansion dynamics in heavy-ion collisions. With the heavy flavor physics trigger developed in this project, a competitive heavy flavor physics program in heavy-ion collisions has been established in CMS. This program allows studies of the fully reconstructed and flavor identified charm, beauty, and exotic hadrons that cover the widest transverse momentum range. The novel measurements supported by the award provide new constraints on the size of the flavor dependence of parton energy loss, the value of the in-medium charm quark diffusion coefficient, the mechanism of charm and beauty quark hadronization, and provide new insights to the nature of the X(3872) hadron.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct Feed High-Level Waste APPS Model Glass Testing (DFHLW APPS) Matrix, Phase 2

This report summarizes the data collected during the batching and melting of a second matrix of Direct Feed High-Level Waste (DFHLW) glasses generated using the preliminary enhanced waste glass models (EWG2.5) and the Britton and Anderson (2024) preliminary DFHLW feed vector. The purpose of these glasses is two-fold: 1. Validate EWG2.5 glass calculations being used in the Aspen Process Performance Simulation (APPS) model. 2. Evaluate and ultimately improve the glass property models and formulation methods used for design of DFHLW glasses as part of an iterative process of data collection and model refinement. Some of the 16 APPS2 glasses tested did not satisfy all target property constraints due to the limited data on DFHLW glass supporting the EWG2.5 models. • One glass, APPS2-10, formed nepheline on canister centerline cooling (CCC) heat-treatment and failed the product consistency test (PCT) response limits. This glass also had high B and Cr release rates for the toxicity characteristic leaching procedure (TCLP). All other glasses were found to satisfy the PCT and TCLP constraints for both quenched and CCC samples. • One glass, APPS2-08, had higher than acceptable viscosity due to magnetite crystallization. • One glass, APPS2-09, formed greater than 2 vol% crystals at 950 °C. As the glass design criterion was that the temperature at 2 vol% crystal (T 2% ) be less than 950 °C, only one glass failed the criteria. However, this criterion is being reevaluated. Four additional glasses formed crystal fractions between 1 and 2 vol% at 950 °C (APPS2-03, -08, -12, and -14). • Four glasses – APPS2-01, -02, -04, and -16 – failed the Monofrax K-3 refractory neck corrosion (k neck ) design limit of 0.04 in. at 1208 °C for 6 d. This is another criterion being reevaluated. Four additional glasses (APPS2-05, -06, -11, and -13) exhibited 0.025 = k neck = 0.04 in. • All 16 glasses passed the sulfur solubility and TCLP constraints. The measured property values were compared to predicted values using EWG2.5 and a selection of other existing models. A few models (e.g., electrical conductivity, TCLP) were found to be adequate for designing DFHLW glasses in the near future, while others require refits or offsets. It is recommended that new property models be developed for EWG3.0, as a large amount of DFHLW glass property data (> 14 × existing data) is expected to be collected in the compositional spaces where no data was previously available. To enable near-term calculations and formulations for designing DFHLW glasses and processing rate estimations, a formulation algorithm with minor modifications will be developed, EWG2.6.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY25 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and image analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and cracks in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), or, in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or more of: height, color, and 16-bit grayscale values as functions of position in a plane projection) to detect signs of surface corrosion and cracking after being trained on similar data with the features to be detected. Although the initial scope included screening for broader indicators of corrosion, e.g., pitting, the identification of potential cracks was prioritized for the past several years at the request of program leadership.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗