Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. IV. LiNi 0.5 Co 0.2 Mn 0.3 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze two lots of fresh LiNi 0.5 Co 0.2 Mn 0.3 O 2 powder and one of the two lot of LiNi0.5Co0.2Mn0.3O2 powder recalcined in air at 750 °C obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.83401 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor sulfur contamination. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surfaces for the first lot, the first lot recalcined, and the second lot of LiNi0.3Co0.1Mn0.2O1.2, LiNi 0.4 Co 0.1 Mn 0.3 O 1.5 , and LiNi 0.4 Co 0.1 Mn 0.2 O 1.3 , respectively

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. V. LiNi 0.4 Co 0.3 0.3 O 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiNi 0.4 Co 0.3 Mn 0.3 O 2 powder obtained from TODA America. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiN i0.4 Co 0.2 Mn 0.3 O 1.6 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VI. LiNi 0.4 Co 0.2 Mn 0.4 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.4 Co 0.2 Mn 0.4 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.5 Co 0.2 Mn 0.5 O 1.9 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VII. LiNi 0.33 Co 0.33 Mn 0.33 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.33 Co 0.33 Mn 0.33 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.4 Co 0.1 Mn 0.7 O 2.0 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VIII. Li 1.2 Ni 0.15 Co 0.1 Mn 0.55 O 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated Li 1.2 Ni 0.15 Co 0.1 Mn 0.55 O 2 powder obtained from TODA America. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.83 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of Li 1.2 Ni 0.4 Co 0.2 Mn 0.9 O 2.8 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. IX. LiCoO 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiCoO 2 powder obtained from BTR New Energy Materials, Inc. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Co 2p, O 1s, C 1s, Co 3s, Co 3p, and Li 1s are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor tin contamination. Making use of the O 1s, Co 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiCo 0.9 O 1.7 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. X. Li 4 Ti 5 O 12

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated Li 4 Ti 5 O 12 powders obtained from Ishihara Sangyo Kaisha, Ltd. and Samsung Fine Chemicals Company, Ltd. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with O 1s, Ti 2p, C 1s, Ti 3s, Li 1s, and Ti 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor potassium signal. Making use of the O 1s, Li 1s, and Ti 3p lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surfaces from Ishihara Sangyo Kaisha, Ltd. and Samsung Fine Chemicals Company, Ltd. of Li 4 Ti 4.7 O 14.1 and Li 4 Ti 4.3 O 13.2 , respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-210-01: Are Clinically Relevant Dosimetric Endpoints Significantly Better with Gating of Lung SBRT Vs. ITV-Based Treatment?: Results of a Large Cohort Investigation Analyzing Predictive Dosimetric Indicators as a Function of Tumor Volume and Motion Amplitude

Purpose: To quantitatively compare patient internal target volume (ITV)-based plans with retrospectively generated gated plans to evaluate potential dosimetric improvements in lung toxicity from gated radiotherapy. Methods: Evaluation was conducted for 150 stereotactic body radiation therapy (SBRT) treatment plans for 128 early-stage (T1–T3, <5cm) NSCLC patients. PTV margins were: ITV+5 mm (ITV-plan) and GTV+5 mm (Gated-plan). ITV-based and gated treatment plans were compared on the same free-breathing CT. ITV-based plan constraints were used to re-optimize and recalculate new gated plans. Plans were generated for 3 fractionation regimens: 3×18Gy, 4×12Gy (original), and 5×10Gy. Physical dose was converted to equivalent dose in 2Gy fractions (EQD2), which was used to determine mean lung dose (MLD) and percent volume of lung receiving ≥20Gy (V20). MLD and V20 differences between gating and ITV-based plans were analyzed as a function of both three-dimensional (3D) motion and tumor volume. The low dose region, V5, was also evaluated. Results: MLD and V20 differences between gated and ITV-based plans were larger for lower (1.48±1.32Gy and 1.44±1.29%) than for upper lobe tumors (0.89±0.74Gy and 0.92±0.71%) due to smaller tumor motion (2.9±3.4mm) compared to lower lobe tumors (8.1±6.1mm). Average differences of <1–2% were noted in V5 between ITV and gated plans. Dosimetric differences between gating and ITV-based methods increased with increasing tumor motion and decreasing tumor volume. Overall, average MLD (8.04±3.92Gy) and V20 (8.29±4.33%) values for ITV-based plans were already well below clinical guidelines, even for the 3×18Gy dose scheme, for which largest differences were noted relative to gated plans. Similar results were obtained for 5×10Gy and 4×12Gy regimens. Conclusion: Clinically relevant improvement in pulmonary toxicity, based on predictors of radiation pneumonitis (MLD and V20) was not generally observed, though improvement for tumors with 3D motion >15 mm, mainly concentrated in peripheral lower lobe tumors, may be considered clinically relevant. Work supported in part by a grant from Varian Medical systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-E-T-746: The Use of Radiochromic Film Analyzed with Three Channel Dosimetry as a Secondary Patient-Specific QA Tool for Small SBRT Fields

Introduction: As diagnostic techniques become more sensitive and targeting methods grow in accuracy, target volumes continue to shrink and SBRT becomes more prevalent. Due to this fact, patient-specific QA must also enhance resolution and accuracy in order to verify dose delivery in these volumes. It has been suggested that when measuring small fields at least two separate detectors be used to verify delivered dose. Therefore, we have instituted a secondary patient QA verification for small (<3cm) SBRT fields using Gafchromic EBT2 film. Methods: Films were cross-calibrated using a Farmer chamber in plastic water at reference conditions as defined by TG-51. Films were scanned, and an RGB calibration curve was created according to best practices published by Ashland, Inc. Four SBRT cases were evaluated both with the Scandidos Delta4 and with EBT2 films sandwiched in plastic water. Raw values obtained from the film were converted to dose using an in-house algorithm employing all three color channels to increase accuracy and dosimetric range. Gamma and dose profile comparisons to Eclipse dose calculations were obtained using RIT and compared to values obtained with the Delta4. Results: Film gamma pass rates at 2% and 2mm were similar to those obtained with the Delta4. However, dose difference histograms showed better absolute dose agreement, with the average mean film dose agreeing with calculation to 0.3% and the Delta4 only agreeing to 3.1% across the cases. Additionally, films provided more resolution than the Delta4 and thus their dose profiles better succeeded in diagnosing dose calculation inaccuracies. Conclusion: We believe that the implementation of secondary patient QA using EBT2 film analyzed with all three color channels is an invaluable tool for evaluation of small SBRT fields. Furthermore, we have shown that this method can sometimes provide a more detailed and faithful reproduction of plan dose than the Delta4.

60 APPLIED LIFE SCIENCES↗

SU-D-204-06: Integration of Machine Learning and Bioinformatics Methods to Analyze Genome-Wide Association Study Data for Rectal Bleeding and Erectile Dysfunction Following Radiotherapy in Prostate Cancer

Purpose: We investigated whether integration of machine learning and bioinformatics techniques on genome-wide association study (GWAS) data can improve the performance of predictive models in predicting the risk of developing radiation-induced late rectal bleeding and erectile dysfunction in prostate cancer patients. Methods: We analyzed a GWAS dataset generated from 385 prostate cancer patients treated with radiotherapy. Using genotype information from these patients, we designed a machine learning-based predictive model of late radiation-induced toxicities: rectal bleeding and erectile dysfunction. The model building process was performed using 2/3 of samples (training) and the predictive model was tested with 1/3 of samples (validation). To identify important single nucleotide polymorphisms (SNPs), we computed the SNP importance score, resulting from our random forest regression model. We performed gene ontology (GO) enrichment analysis for nearby genes of the important SNPs. Results: After univariate analysis on the training dataset, we filtered out many SNPs with p>0.001, resulting in 749 and 367 SNPs that were used in the model building process for rectal bleeding and erectile dysfunction, respectively. On the validation dataset, our random forest regression model achieved the area under the curve (AUC)=0.70 and 0.62 for rectal bleeding and erectile dysfunction, respectively. We performed GO enrichment analysis for the top 25%, 50%, 75%, and 100% SNPs out of the select SNPs in the univariate analysis. When we used the top 50% SNPs, more plausible biological processes were obtained for both toxicities. An additional test with the top 50% SNPs improved predictive power with AUC=0.71 and 0.65 for rectal bleeding and erectile dysfunction. A better performance was achieved with AUC=0.67 when age and androgen deprivation therapy were added to the model for erectile dysfunction. Conclusion: Our approach that combines machine learning and bioinformatics techniques enabled designing better models and identifying more plausible biological processes associated with the outcomes.

60 APPLIED LIFE SCIENCES↗

SU-F-T-465: Two Years of Radiotherapy Treatments Analyzed Through MLC Log Files

Purpose: To present treatment statistics of a Varian Novalis Tx using more than 90,000 Varian Dynalog files collected over the past 2 years. Methods: Varian Dynalog files are recorded for every patient treated on our Varian Novalis Tx. The files are collected and analyzed daily to check interfraction agreement of treatment deliveries. This is accomplished by creating fluence maps from the data contained in the Dynalog files. From the Dynalog files we have also compiled statistics for treatment delivery times, MLC errors, gantry errors and collimator errors. Results: The mean treatment time for VMAT patients was 153 ± 86 seconds while the mean treatment time for step & shoot was 256 ± 149 seconds. Patient’s treatment times showed a variation of 0.4% over there treatment course for VMAT and 0.5% for step & shoot. The average field sizes were 40 cm2 and 26 cm2 for VMAT and step & shoot respectively. VMAT beams contained and average overall leaf travel of 34.17 meters and step & shoot beams averaged less than half of that at 15.93 meters. When comparing planned and delivered fluence maps generated using the Dynalog files VMAT plans showed an average gamma passing percentage of 99.85 ± 0.47. Step & shoot plans showed an average gamma passing percentage of 97.04 ± 0.04. 5.3% of beams contained an MLC error greater than 1 mm and 2.4% had an error greater than 2mm. The mean gantry speed for VMAT plans was 1.01 degrees/s with a maximum of 6.5 degrees/s. Conclusion: Varian Dynalog files are useful for monitoring machine performance treatment parameters. The Dynalog files have shown that the performance of the Novalis Tx is consistent over the course of a patients treatment with only slight variations in patient treatment times and a low rate of MLC errors.

60 APPLIED LIFE SCIENCES↗

Development of the DIFFRACALC program for analyzing the phase composition of alloys

The DiffraCalc software package is developed for automatic indexing of electron diffraction patterns. The program can operate with the existing base of X-ray diffraction data, containing information about the crystal structures of more than 100 thousands of materials. This information has been extracted from open sources. A compatibility with standard crystallographic files is implemented. In the indexing mode, the program automatically analyzes an experimental diffraction pattern, implementing a search for an appropriate phase from the list compiled by a user proceeding from the crystallographic database. The indexing mode algorithm is constructed using the method of pair reflections. In the simulation mode, the program calculates the electron diffraction pattern for a specified material, which is an additional way to verify the indexing results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the components of the tensor analyzing power in the reaction γd → ppπ{sup −} at high proton momenta

Results obtained by measuring three components of the tensor analyzing power in the reaction of π{sup −} -meson photoproduction on a deuteron at final-proton momenta between 300 and 700 MeV/c are presented. The measurements in question were performed at the VEPP-3 storage ring by using its internal deuterium-gas target featuring a tensor polarization with the aid of detection of two protons in coincidence. The experimental results obtained in this way are compared with their counterparts calculated theoretically.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complete set of deuteron analyzing powers for dp elastic scattering at intermediate energies

With the aim of clarifying roles of the 3NFs in nuclei experimental programs with polarized deuterons beams at intermediate energies are in progress at RIKEN RI Beam Factory. As the first step, we have measured a complete set of deuteron analyzing powers (iT{sub 11}, T{sub 20}, T{sub 21}, T{sub 22}) in deuteron-proton elastic scattering at 250 and 294 MeV/nucleon. The obtained data are compared with the Faddeev calculations based on the modern nucleon-nucleon forces together with the Tucson-Melbourne’99, and UrbanaIX three nucleon forces.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of the charge transport mechanism in p-n junctions by analyzing temperature dependences of forward current-voltage characteristics

A method is suggested for determining the charge transport mechanism in p-n junctions by analyzing the temperature dependence of forward current-voltage characteristics at a low injection level. The method has been experimentally tested with Si:Au diodes, green GaP LEDs, and blue AlGaN/InGaN/GaN LEDS with a quantum well.

36 MATERIALS SCIENCE↗

A Method for Analyzing the Domain Structure in Magnetic Powder Microparticles

A method for analyzing the domain structure in magnetic powder microparticles based on the Mössbauer effect is proposed. This method has been experimentally verified for gadolinium ferrite-garnet (Gd{sub 3}Fe{sub 5}O{sub 12}) powder particles 40 ± 5 μm in diameter in the vicinity of the magnetic compensation point T{sub cm} = 286 K. It is shown that ferrite particles are single-domain near T{sub cm} and pass to the multidomain state while moving away from T{sub cm}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Survey of Methods for Analyzing and Improving GPU Energy Efficiency

Recent years have witnessed a phenomenal growth in the computational capabilities and applications of GPUs. However, this trend has also led to dramatic increase in their power consumption. This paper surveys research works on analyzing and improving energy efficiency of GPUs. It also provides a classification of these techniques on the basis of their main research idea. Further, it attempts to synthesize research works which compare energy efficiency of GPUs with other computing systems, e.g. FPGAs and CPUs. The aim of this survey is to provide researchers with knowledge of state-of-the-art in GPU power management and motivate them to architect highly energy-efficient GPUs of tomorrow.

architecture techniques↗

Securing Your ICS Software with the AttackSurface Host Analyzer (AHA)

Implementing a secure development lifecycle (SDL) presents increasing challenges to software developers as they must ensure software correctly integrates both underlying operating system security features while also managing dependencies on third-party libraries or executables. There are a growing number of security functions that require a close integration between the OS security features and software builds to ensure strong protection. Furthermore, as software platforms grow in complexity, they present many opportunities for misconfigurations and inadequate defenses. This challenge is especially prevalent for industrial control systems (ICS), which oten depend on both legacy sotware platforms, or out of date operating systems. This paper presents the AttackSurface Host Analyzer (AHA) tool, which is used to assess the security of a software platform through its integration with a host operating system. The tool collects data from the various platforms running on an OS, evaluates an array of security properties, and then introduces metrics and visualizations to provide feedback on the system's attack surface based on the external interconnections and the completeness of the available security protections. The paper then explores the attack surface of a variety of industry-standard ICS platforms to provide insight into the current degree of protection enabled by them.

24 POWER TRANSMISSION AND DISTRIBUTION↗