Search NASA⌕ Search

SEARCH · Search NASA

Results for “Basic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

TU-A-18A-01: Basic Principles of PET/CT, Calibration Methods and Contrast Recovery Across Multiple Cameras

This continuing education session will discuss the physical principles of PET/CT imaging and characterization of contrast recovery using accreditation phantoms. A detailed overview will be given on the physical principles of PET including positron decay physics, 2D and 3D data acquisition, time-of-flight, scatter correction, CT attenuation correction, and image reconstruction. Instrument quality control and calibration procedures will be discussed. Technical challenges, common image artifacts and strategies to mitigate these issues will also be discussed. Data will be presented on acquisition techniques and reconstruction parameters affecting contrast recovery. The discussion will emphasize the minimization of reconstruction differences in quantification metrics such as SUV and contrast recovery coefficients for the NEMA and ACR clinical trial phantoms. Data from new and older generation scanners will be shown including comparison of contrast recovery measurements to their analytical solutions. The goal of this session is to update attendees on the quality control and calibration of PET/CT scanners, on methods to establish a common calibration for PET/CT scanners to control for instrument variance across multiple sites. Learning Objectives: Review the physical principles of PET/CT, quality control and calibration Gain further understanding on how to apply techniques for improving quantitative agreement across multiple cameras Describe the differences between measured and expected contrast recovery for the NEMA and ACR PET phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dedicated breast computed tomography: Basic aspects

X-ray mammography of the compressed breast is well recognized as the “gold standard” for early detection of breast cancer, but its performance is not ideal. One limitation of screening mammography is tissue superposition, particularly for dense breasts. Since 2001, several research groups in the USA and in the European Union have developed computed tomography (CT) systems with digital detector technology dedicated to x-ray imaging of the uncompressed breast (breast CT or BCT) for breast cancer screening and diagnosis. This CT technology—tracing back to initial studies in the 1970s—allows some of the limitations of mammography to be overcome, keeping the levels of radiation dose to the radiosensitive breast glandular tissue similar to that of two-view mammography for the same breast size and composition. This paper presents an evaluation of the research efforts carried out in the invention, development, and improvement of BCT with dedicated scanners with state-of-the-art technology, including initial steps toward commercialization, after more than a decade of R and D in the laboratory and/or in the clinic. The intended focus here is on the technological/engineering aspects of BCT and on outlining advantages and limitations as reported in the related literature. Prospects for future research in this field are discussed.

60 APPLIED LIFE SCIENCES↗

MO-DE-209-00: DBT Physics Basic to Advanced

Digital Breast Tomosynthesis (DBT) is rapidly replacing mammography as the standard of care in breast cancer screening and diagnosis. DBT is a form of computed tomography, in which a limited set of projection images are acquired over a small angular range and reconstructed into tomographic data. The angular range varies from 15° to 50° and the number of projections varies between 9 and 25 projections, as determined by the equipment manufacturer. It is equally valid to treat DBT as the digital analog of classical tomography – that is, linear tomography. In fact, the name “tomosynthesis” stands for “synthetic tomography.” DBT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DBT systems is a hybrid between computed tomography and classical tomographic methods. In this lecture, we will explore the continuum from radiography to computed tomography to illustrate the characteristics of DBT. This lecture will consist of four presentations that will provide a complete overview of DBT, including a review of the fundamentals of DBT acquisition, a discussion of DBT reconstruction methods, an overview of dosimetry for DBT systems, and summary of the underlying image theory of DBT thereby relating image quality and dose. Learning Objectives: To understand the fundamental principles behind tomosynthesis image acquisition. To understand the fundamentals of tomosynthesis image reconstruction. To learn the determinants of image quality and dose in DBT, including measurement techniques. To learn the image theory underlying tomosynthesis, and the relationship between dose and image quality. ADM is a consultant to, and holds stock in, Real Time Tomography, LLC. ADM receives research support from Hologic Inc., Analogic Inc., and Barco NV.; ADM is a member of the Scientific Advisory Board for Gamma Medica Inc.; A. Maidment, Research Support, Hologic, Inc.; Research Support, Barco, Inc.; Scientific Advisory Board, Gamma Medica, Inc.; Scientific Advisory Board, Real-Time Tomography, LLC.; Shareholder, Real-Time Tomography, LLC; J. Mainprize, Our lab has a research agreement with GE Healthcare on various topics in digital mammography and digital tomosynthesis; W. Zhao, Research grant from Siemens Health Care.

60 APPLIED LIFE SCIENCES↗

WE-D-BRB-01: Basic Physics of Proton Therapy

The goal of this session is to review the physics of proton therapy, treatment planning techniques, and the use of volumetric imaging in proton therapy. The course material covers the physics of proton interaction with matter and physical characteristics of clinical proton beams. It will provide information on proton delivery systems and beam delivery techniques for double scattering (DS), uniform scanning (US), and pencil beam scanning (PBS). The session covers the treatment planning strategies used in DS, US, and PBS for various anatomical sites, methods to address uncertainties in proton therapy and uncertainty mitigation to generate robust treatment plans. It introduces the audience to the current status of image guided proton therapy and clinical applications of CBCT for proton therapy. It outlines the importance of volumetric imaging in proton therapy. Learning Objectives: Gain knowledge in proton therapy physics, and treatment planning for proton therapy including intensity modulated proton therapy. The current state of volumetric image guidance equipment in proton therapy. Clinical applications of CBCT and its advantage over orthogonal imaging for proton therapy. B. Teo, B.K Teo had received travel funds from IBA in 2015.

60 APPLIED LIFE SCIENCES↗

WE-D-BRB-00: Basics of Proton Therapy

The goal of this session is to review the physics of proton therapy, treatment planning techniques, and the use of volumetric imaging in proton therapy. The course material covers the physics of proton interaction with matter and physical characteristics of clinical proton beams. It will provide information on proton delivery systems and beam delivery techniques for double scattering (DS), uniform scanning (US), and pencil beam scanning (PBS). The session covers the treatment planning strategies used in DS, US, and PBS for various anatomical sites, methods to address uncertainties in proton therapy and uncertainty mitigation to generate robust treatment plans. It introduces the audience to the current status of image guided proton therapy and clinical applications of CBCT for proton therapy. It outlines the importance of volumetric imaging in proton therapy. Learning Objectives: Gain knowledge in proton therapy physics, and treatment planning for proton therapy including intensity modulated proton therapy. The current state of volumetric image guidance equipment in proton therapy. Clinical applications of CBCT and its advantage over orthogonal imaging for proton therapy. B. Teo, B.K Teo had received travel funds from IBA in 2015.

60 APPLIED LIFE SCIENCES↗

Basic results of investigations of scission neutrons in nuclear fission at low excitation energies

To estimate the main characteristics of neutrons emitted shortly before the scission of a fissioning nucleus, various experiments sensitive to the presence of these scission neutrons in thermal-neutron-induced fission of {sup 235}U and spontaneous fission of {sup 252}Cf were performed. The results of the experiments were analyzed within theoretical calculations allowing for various possible neutron-emission mechanisms, including the possibility of the emergence of neutrons from the scission of a nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Basic parameters of the gamma-decay process and properties of the {sup 174}Yb nucleus that manifest themselves in radiative resonance-and thermal-neutron capture

An independent analysis of available data on the intensities of primary gamma rays from the capture of {approx}2-keV neutrons by a {sup 173}Yb nucleus is performed. The distribution of the scatter of these intensities around the average value is approximated in various intervals of energies of primary gamma transitions. An extrapolation of the distributions obtained in this way to zero detection threshold for the intensity of a primary gamma transition makes it possible to estimate, independently of other experimental procedures, the expected number of levels of both parities for spins in the range J = 1-4 and the total possible sum of partial widths with respect to electric and magnetic dipole gamma transitions to levels whose excitation energies extend up to about 4 MeV. The results obtained in this way for the level density and the sum of radiative strength functions confirm the characteristic features of analogous data extracted from the intensities of two-step gamma-ray cascades initiated by radiative thermal-neutron capture by 40 {<=} A {<=} 200 nuclei and also make it possible to assess the sign and magnitude of their systematic uncertainty associated with a very strong dependence of radiative strength functions for cascade gamma transitions on the structure of the excited level, at least for excitation energies below half the neutron binding energy. A comparison with model concepts of the level density reveals that the {sup 174}Yb nucleus is in a superfluid states for the bulk of excited levels, at least below 3.5 to 4 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New model of the cascade gamma decay of neutron resonances for practitioners: Basic concepts and attainable precision

A model-free extraction of level densities and radiative strength functions for cascade dipole gamma transitions that has been performed to date revealed the need for developing a new model of the deexcitation of compound states of nuclei having arbitrary masses and belonging to any type over a broad range of their excitations. Such a model should provide a practical means for determining thresholds for the breaking of nucleon Cooper pairs below the neutron binding energy, the relationship between the level densities for excitations of the quasiparticle and phonon types, and the emission widths for nuclear-reaction products in excited nuclei. From an analysis of data on the intensities of two-step cascades initiated by radiative thermal-neutron capture, it can be seen that the highest precision in describing available experimental spectra is reached upon taking into account the breaking of three to four Cooper pairs of nucleons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of methods for calculating basic features of the nuclear contribution to single event upsets under the effect of protons of moderately high energy

As a continuation and a development of previous studies of our group that were devoted to the investigation of nuclear reactions induced by protons of moderately high energy (between 10 and 400 MeV) in silicon, aluminum, and tungsten atoms, the results obtained by exploring nuclear reactions on atoms of copper, which is among the most important components in materials for contact pads and pathways in modern and future ultralarge-scale integration circuits, especially in three-dimensional topology, are reported in the present article. The nuclear reactions in question lead to the formation of the mass and charge spectra of recoil nuclei ranging fromheavy target nuclei down to helium and hydrogen. The kineticenergy spectra of reaction products are calculated. The results of the calculations based on the procedure developed by our group are compared with the results of calculations and experiments performed by other authors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin polarized {sup 3}He: From basic research to medical applications

Polarization of {sup 3}He gas by means of optical pumping is well known since the early 1960s with first applications in fundamental physics. Some thirty years later it was discovered, that one can use hyperpolarized {sup 3}He as contrast agent for magnetic resonance imaging of the lung. The wide interest in this new method made it necessary to find ways of polarizing {sup 3}He in large quantities with high polarization degrees. A high performance polarizing facility has been developed at the University of Mainz, designed for centralized production of hyperpolarized {sup 3}He gas. We present the Mainz concept as well as some examples of numerous applications of spin polarized {sup 3}He in fundamental research and medical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Subthreshold High-Pressure Discharge Excited by a Microwave Beam: Physical Basics and Applications

A new form of discharge excited by a microwave beam in a high-pressure (up to atmospheric and higher) gas in free space and in a closed chamber is discussed. For the first time, the discharge was implemented by means of a gyrotron with a pulse power of 200 ≤ P ≤ 600 kW, a pulse duration of 0.5 ≤ τ ≤ 20 ms, and a wavelength of λ = 0.4 cm. Under deeply subthreshold conditions in atmospheric-pressure air, a plasma column with a length of L = 50 cm was generated by a microwave beam formed with the help of a quasi-optical transmission line. With the use of the MIG-3 gyrotron complex with the above parameters, generation of a plasma column with a length of several meters is possible in principle. The parameters and structure of the formation of the plasma investigated make it possible to class it as a self-non-self-sustained (SNSS) discharge, discovered and described for the first time at the Prokhorov General Physics Institute, Russian Academy of Sciences. One of the important applications of this type of discharge is plasmachemical cleaning of the urban air environment of hazardous contaminants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potentialities and basic principles of controlling the plastic relaxation of GeSi/Si and Ge/Si films with stepwise variation in the composition

GeSi/Si heterostructures consisting of a plastically relaxed layer that includes various fractions of Ge and which is grown on Si (001) span the values of the lattice parameter from equal to that in silicon to equal to that in germanium. The corresponding substrates are conventionally referred to as artificial. A number of methods exist for growing high-quality GeSi layers with as large as 100% of Ge on Si (001) substrates through an intermediate GeSi layer with a varying composition. However, it is desirable in a number of cases to have ultrathin (<1 {mu}m) GeSi and Ge layers directly on the Si (001) substrate for practical applications. The results of new methods such as the use of a buffer Si layer grown at a comparatively low temperature (300-400 Degree-Sign C) in plastic relaxation of the GeSi/Si(001) heterostructures and also the use of surfactants (antimony and hydrogen) are analyzed. The examples of artificial introduction of centers for origination of misfit dislocations as an alternative to their introduction from the rough surface are considered. It can be concluded that, in order to expand the range of potentialities of growing perfect plastically relaxed GeSi (001) films, it is necessary to (i) make it possible to form in a controlled manner the centers for origination of the misfit dislocations and (ii) retard or completely suppress the transition of the growth mechanism from two-to three-dimensional in order to prevent the formation of additional misfit dislocations from the surface of the stressed film and, correspondingly, additional threading dislocations.

36 MATERIALS SCIENCE↗

Basic Requirements of Spin-Flip Raman Scattering on Excitonic Resonances and Its Modulation through Additional High-Energy Illumination in Semiconductor Heterostructures

We describe the major requirements to experimentally perform and observe resonant spin-flip Raman scattering on excitonic resonances in low-dimensional semiconductors. We characterize in detail the properties of this resonant light scattering technique and evaluate the criteria, which must be fulfilled by the experimental setup and the semiconductor sample studied to be able to observe a spin-flip scattering process. We also demonstrate the influence of additional unpolarized laser illumination with energies, which exceed considerably the band gap energy of the semiconductor nanostructure under study, on the resonantly excited electron spin-flip scattering in InAs-based quantum dot ensembles as well as on the paramagnetic Mn-ion spin-flip in (Zn,Mn)Se/(Zn,Be)Se quantum wells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

BASIC HARTREE-FOCK PROXY APPLICTION

This proxy application simulates the compute load and data-movement of the kernel of the Hartree-Fock method in quantum chemistry. The proxy features a simplified algorithm for computing electron repulsion integrals that is easily offloaded to GPUs.

FLETCHER, GRAHAMD↗