Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A wire calorimeter for the SPIDER beam: Experimental tests and feasibility study

To study and optimize negative ion production and acceleration, in view of the use of neutral beam injectors in the ITER project, the SPIDER test facility (particle energy 100keV; beam current 50A, distributed over 1280 beamlets) is under construction in Padova, with the aim of testing beam characteristics and to verify the source proper operation, by means of several diagnostic systems. An array of tungsten wires, directly exposed to the beam and consequently heated to high temperature, is used in similar experiments at IPP-Garching to study the beam optics, which is one of the most important issues, in a qualitative way. The present contribution gives a description of an experimental investigation of the behavior of tungsten wires under high heat loads in vacuum. Samples of tungsten wires are heated by electrical currents and the emitted light is measured by a camera in the 400-1100nm wavelength range, which is proposed as a calibration tool. Simultaneously, the voltage applied to the wire is measured to study the dependency of emissivity on temperature. The feasibility study of a wire calorimeter for SPIDER is finally proposed; to this purpose, the expected behaviour of tungsten with the two-dimensional beam profile in SPIDER is numerically addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo Simulations Of The Dose Distributions From Carbon Microbeams Used In An Experimental Radiation Therapy Method

Recent upgrades of the MCNPX Monte Carlo code include transport of heavy ions. We employed the new code to simulate the energy and dose distributions produced by carbon beams in rabbit's head in and around a brain tumor. The work was within our experimental technique of interlaced carbon microbeams, which uses two 90 deg. arrays of parallel, thin planes of carbon beams (microbeams) interlacing to produce a solid beam at the target. A similar version of the method was earlier developed with synchrotron-generated x-ray microbeams. We first simulated the Bragg peak in high density polyethylene and other materials, where we could compare the calculated carbon energy deposition to the measured data produced at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). The results showed that new MCNPX code gives a reasonable account of the carbon beam's dose up to {approx}200 MeV/nucleon beam energy. At higher energies, which were not relevant to our project, the model failed to reproduce the Bragg-peak's extent of increasing nuclear breakup tail. In our model calculations we determined the dose distribution along the beam path, including the angular straggling of the microbeams, and used the data for determining the optimal values of beam spacing in the array for producing adequate beam interlacing at the target. We also determined, for the purpose of Bragg-peak spreading at the target, the relative beam intensities of the consecutive exposures with stepwise lower beam energies, and simulated the resulting dose distribution in the spread out Bragg-peak. The details of the simulation methods used and the results obtained are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uniform deposition of size-selected clusters using Lissajous scanning

Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt{sub n} (n = 7, 15, 20) clusters uniformly deposited on the Al{sub 2}O{sub 3}/NiAl(110) surface and demonstrated the importance of uniform deposition.

42 ENGINEERING↗

Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water

Purpose: To test the use of a three-dimensional (3D) optical cone beam computed tomography reconstruction algorithm, for estimation of the imparted 3D dose distribution from megavoltage photon beams in a water tank for quality assurance, by imaging the induced Cherenkov-excited fluorescence (CEF). Methods: An intensified charge-coupled device coupled to a standard nontelecentric camera lens was used to tomographically acquire two-dimensional (2D) projection images of CEF from a complex multileaf collimator (MLC) shaped 6 MV linear accelerator x-ray photon beam operating at a dose rate of 600 MU/min. The resulting projections were used to reconstruct the 3D CEF light distribution, a potential surrogate of imparted dose, using a Feldkamp–Davis–Kress cone beam back reconstruction algorithm. Finally, the reconstructed light distributions were compared to the expected dose values from one-dimensional diode scans, 2D film measurements, and the 3D distribution generated from the clinical Varian ECLIPSE treatment planning system using a gamma index analysis. A Monte Carlo derived correction was applied to the Cherenkov reconstructions to account for beam hardening artifacts. Results: 3D light volumes were successfully reconstructed over a 400 × 400 × 350 mm{sup 3} volume at a resolution of 1 mm. The Cherenkov reconstructions showed agreement with all comparative methods and were also able to recover both inter- and intra-MLC leaf leakage. Based upon a 3%/3 mm criterion, the experimental Cherenkov light measurements showed an 83%–99% pass fraction depending on the chosen threshold dose. Conclusions: The results from this study demonstrate the use of optical cone beam computed tomography using CEF for the profiling of the imparted dose distribution from large area megavoltage photon beams in water.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-262: Development of An In-House Forward Planning System for Conformal Arc Therapy

Purpose: Conformal radiotherapy with forward planning has many practical advantages (e.g., more uniform target dose) and has been used routinely for stereotactic body radiation therapy (SBRT) and other conventional treatment. This study investigates a forward-planning approach for conformal arc therapy and a dedicated treatment planning system (TPS) for a newly designed cobalt 60 machine with a ring type gantry and a multileaf collimator (MLC). Methods: Conformal arcs were modeled with continuous delivery of treatment fields conformal to the target cross-section. Treatment plans were further optimized by weighting or offsetting beams based on the target-critical structure relationship. CT and structure data of seven previous SBRT patients treated at our center were used for plan evaluation. An in-house forward planning tool was developed to aid the forward planning process. A graphical user interface (GUI) was designed with interactive and automatic adjustment between beam gantry angle and the beam weight. Dose distributions were calculated using our in-house Monte Carlo based TPS. Dose contributions from individual beam angles were summed together with different weight factors, which were continuously optimized until the pre-set dose conformity goal was met. Results: We were able to achieve target coverage and critical structure sparing to meet the required clinical criteria in all studied cases. It should be mentioned that those cases were selected having critical structures not proximal to the target. However, this was usually the case in the majority of SBRT cases especially those involving lung targets. The developed GUI tool was very useful in the forward treatment planning process. Conclusion: Conformal arcs can be used successfully on the new Cobalt 60 modality for the treatment of a sizeable fraction of cancer patients, which can be efficiently planned with our simple forward planning approach.

60 APPLIED LIFE SCIENCES↗

Halo formation and self-pinching of an electron beam undergoing the Weibel instability

The collisionless Maxwellization of the energy distribution of an electron beam undergoing Weibel filamentation instability in a dense background plasma is demonstrated. While binary collisions between discrete charged particles are usually responsible for establishing the Maxwell-Boltzmann distribution (MBD) of non-equilibrium plasmas, we demonstrate that the same effect is achieved through collective collisions between multiple beam filaments. The final state of the filaments' merger is a single pinched beam surrounded by a wide halo. An analytic model for the equilibrated beam is developed and used to estimate spatial profiles of the pinched beam and its halo, the temperature, and the magnetic field. Results of analytical theory agree well with those of particle-in-cell simulations. Deviations from the MBD are explained by incomplete Maxwellization of the electrons with high and low transverse energies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A chopper system for shortening the duration of pulsed supersonic beams seeded with NO or Br{sub 2} down to 13 μs

A chopper wheel construct is used to shorten the duration of a molecular beam to 13 μs. Molecular beams seeded with NO or with Br{sub 2} and an initial pulse width of ≥200 μs were passed through a spinning chopper wheel, which was driven by a brushless DC in vacuo motor at a range of speeds, from 3000 rpm to 80 000 rpm. The resulting duration of the molecular-beam pulses measured at the laser detection volume ranged from 80 μs to 13 μs and was the same for both NO and Br{sub 2}. The duration is consistent with a simple analytical model, and the minimum pulse width measured is limited by the spreading of the beam between the chopper and the detection point as a consequence of the longitudinal velocity distribution of the beam. The setup adopted here effectively eliminates buildup of background gas without the use of a differential pumping stage, and a clean narrow pulse is obtained with low rotational temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of electron beam parameters on coherent electron cooling

Coherent electron cooling (CeC) promises to revolutionize the cooling of high energy hadron beams. The intricate dynamics of the CeC depends both on the local density and energy distribution of the beam. The variations of the local density (beam current) are inevitable in any realistic beam. Hence, in this paper we propose a novel method of beam conditioning. The conditioning provides compensation of effect from such variation by a correlated energy modulation. We use our analytical FEL model for an electron bunch with Gaussian line charge density and cosine-type energy variation along bunch. We analyze the phase variation between the electron density modulation at the exit of the FEL-amplifier and the ions inducing it in the modulator as a function of the peak current and the electron beam energy. Based on this analysis, electron bunch parameters for optimal CeC cooling are found numerically.

43 PARTICLE ACCELERATORS↗

Effects of nuclear orientation on the mass distribution of fission fragments in the reaction of {sup 36}S+{sup 238}U

Fragment mass distributions for fission after full momentum transfer were measured for the reaction {sup 36}S+{sup 238}U at bombarding energies around the Coulomb barrier. The data revealed a transition from symmetry to asymmetry mass distributions when the beam energies were decreased from above-barrier to sub-barrier values. The main components of the asymmetric mass distribution are at A{sub H}{approx_equal}200 and A{sub L}{approx_equal}74. The asymmetric fission is attributed to quasifission of the reacting system at polar collisions, whereas the symmetric fission originates from the compound nucleus produced in equatorial collisions. The results suggest a strong influence of orientation effects of the deformed target nuclei on fusion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Astigmatic electron beam propagation

An astigmatic electron beam with an ellipticity ratio of approximately 2:1 was examined using the Enhanced Modified Faraday Cup (EMFC) diagnostic to measure its properties and show how the power density distribution varies near the beam waist. Results show that the beam has two power density peaks, one on either side of the beam crossover point, resulting from different focal distances of the major and minor axes of the elliptical beam shape. Quantification of the beam properties was used to establish a depth-of-field where the beam diameter and peak power densities are relatively constant. For the 1 kW beam studied here, the depth-of-field measured approximately ±5 mm from the beam crossover point, illustrating how electron beam diagnostics can be used to identify process control limits for repeatable and reliable welds under non-ideal electron beam power density distribution conditions.

36 MATERIALS SCIENCE↗

Alignment of the straw tracking detectors for the Fermilab Muon $g − 2$ experiment and systematic studies for a muon electric dipole moment measurement

The Fermilab Muon $g-2$ experiment is currently preparing for its fourth data-taking period (Run-4). The experiment-wide effort on the analysis of Run-1 data is nearing completion, with the announcement of the first result expected in the coming months. The final goal of the experiment is to determine the muon magnetic anomaly to a precision of 140 ppb. This level of precision will provide indirect evidence of new physics, if the central value agrees with the previously-measured value of the magnetic anomaly. Essential in reducing the systematic uncertainty, through measurements of the muon beam profile, are the in-vacuum straw tracking detectors. A crucial prerequisite in obtaining accurate distributions of the beam profile is the internal alignment of the tracking detectors, which is described in this thesis. As a result of this position calibration, the tracking efficiency has increased by 3%, while the track quality increased by 4%. This thesis also discusses an additional measurement that will be made using the tracking detectors: a search for an electric dipole moment (EDM) of the muon, through the direct detection of an oscillation in the average vertical angle of the electron from the muon decay. An observation of a muon EDM would be evidencemore » of new physics and would provide a new source of CP violation in the charged lepton sector. Essential in measuring the EDM are accurate and precise estimations of potential non-zero radial and longitudinal magnetic fields, which were estimated using the Run-1 data. In addition, a preliminary analysis using the Run-1 data was undertaken to estimate the available precision for the magnetic anomaly measurement using the tracking detectors.« less

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-E-BRE-08: GPU-Monte Carlo Based Fast IMRT Plan Optimization

Purpose: Intensity-modulated radiation treatment (IMRT) plan optimization needs pre-calculated beamlet dose distribution. Pencil-beam or superposition/convolution type algorithms are typically used because of high computation speed. However, inaccurate beamlet dose distributions, particularly in cases with high levels of inhomogeneity, may mislead optimization, hindering the resulting plan quality. It is desire to use Monte Carlo (MC) methods for beamlet dose calculations. Yet, the long computational time from repeated dose calculations for a number of beamlets prevents this application. It is our objective to integrate a GPU-based MC dose engine in lung IMRT optimization using a novel two-steps workflow. Methods: A GPU-based MC code gDPM is used. Each particle is tagged with an index of a beamlet where the source particle is from. Deposit dose are stored separately for beamlets based on the index. Due to limited GPU memory size, a pyramid space is allocated for each beamlet, and dose outside the space is neglected. A two-steps optimization workflow is proposed for fast MC-based optimization. At first step, rough beamlet dose calculations is conducted with only a small number of particles per beamlet. Plan optimization is followed to get an approximated fluence map. In the second step, more accurate beamlet doses are calculated, where sampled number of particles for a beamlet is proportional to the intensity determined previously. A second-round optimization is conducted, yielding the final Result. Results: For a lung case with 5317 beamlets, 10{sup 5} particles per beamlet in the first round, and 10{sup 8} particles per beam in the second round are enough to get a good plan quality. The total simulation time is 96.4 sec. Conclusion: A fast GPU-based MC dose calculation method along with a novel two-step optimization workflow are developed. The high efficiency allows the use of MC for IMRT optimizations.

60 APPLIED LIFE SCIENCES↗

Rapidity distributions of Z = 1 isotopes and the nuclear symmetry energy from Sn+Sn collisions with radioactive beams at 270 MeV/nucleon

The rapidity distributions of hydrogen isotopes emitted from central collisions of neutron-rich 132 Sn+ 124 Sn and neutron-deficient 108 Sn+ 112 Sn systems at 270 MeV/nucleon were investigated at RIKEN-RIBF. The data are compared with antisymmetrized molecular dynamics (AMD) calculations and the rapidity distributions can be reproduced after adjusting the in-medium nucleon-nucleon cross sections. The double ratios between the two reaction systems taken for the relative yields of deuteron to proton (d/p) and triton to proton (t/p) are further examined in the midrapidity domain, where the adjustments in the AMD calculations do not affect much on them. The d/p and t/p double ratios at midrapidity agree well with the ratio of the system neutron numbers and its squared value, respectively, and the rapidity dependence of these double ratios is consistent with a picture of partial mixing of colliding nuclei. By comparing with the AMD model which shows a strong symmetry energy dependence of the t/p double ratio, the experimental result in the midrapidity domain favors the calculation with a symmetry-energy slope parameter around L = 46 MeV rather than L = 108 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental probability density distributions for optical and infrared cross-beam units

A series of cross beam experiments for measuring meteorological parameters was conducted. Both optical and infrared sensors were tested for comparison. The test configuration and experiment identification are provided. A data report is presented for an approximate analysis of the probability density distributions of the signals from both the optical and the infared units. Two runs representing each of the two types of cross-beam units were selected for analysis. Probability density functions are also presented for the instantaneous product of the signals for each of the runs.

Huff, L. L.↗

Adiabatic warm-fluid equilibrium theory of thermal charged-particle beams in alternating-gradient focusing fields

An adiabatic warm-fluid equilibrium theory for a thermal charged-particle beam in an alternating-gradient focusing field is presented. Warm-fluid equilibrium equations are solved in the paraxial approximation. The theory predicts that the four-dimensional rms thermal emittance of the beam is conserved, but the two-dimensional rms thermal emittances are not constant. The rms beam envelope equations and the self-consistent Poisson equation, governing the beam density and potential distributions, are derived. Although the presented rms beam envelope equations have the same form as the previously known rms beam envelope equations, the evolution of the rms emittances in the present theory is given by analytical expressions. The density does not have the simplest elliptical symmetry, but the constant-density contours are ellipses, and the aspect ratio of the elliptical constant-density contours decreases as the density decreases along the transverse displacement from the beam axis. For high-intensity beams, the beam density profile is flat in the center of the beam and falls off rapidly within a few Debye lengths, and the rate at which the density falls is approximately isotropic in the transverse directions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for more accurate transmittance measurements of low-angle scattering samples using an integrating sphere with an entry port beam diffuser

For most integrating sphere measurements, the difference in light distribution between a specular reference beam and a diffused sample beam can result in significant errors. The problem becomes especially pronounced in integrating spheres that include a port for reflectance or diffuse transmittance measurements. The port is included in many standard spectrophotometers to facilitate a multipurpose instrument, however, absorption around the port edge can result in a detected signal that is too low. The absorption effect is especially apparent for low-angle scattering samples, because a significant portion of the light is scattered directly onto that edge. In this paper, a method for more accurate transmittance measurements of low-angle light-scattering samples is presented. The method uses a standard integrating sphere spectrophotometer, and the problem with increased absorption around the port edge is addressed by introducing a diffuser between the sample and the integrating sphere during both reference and sample scan. This reduces the discrepancy between the two scans and spreads the scattered light over a greater portion of the sphere wall. The problem with multiple reflections between the sample and diffuser is successfully addressed using a correction factor. The method is tested for two patterned glass samples with low-angle scattering and in both cases the transmittance accuracy is significantly improved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗