Search NASA⌕ Search

SEARCH · Search NASA

Results for “Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

CALSPEC: Wide Field Camera 3 Infrared Grism Spectrophotometry

The collections of spectral energy distributions (SEDs) in the Hubble Space Telescope (HST) CALSPEC database are augmented by 19 infrared (IR) SEDs from Wide Field Camera 3 (WFC3) IR grism spectra. Together, the two IR grisms, G102 and G141, cover the 0.8–1.7 μm range with resolutions of R = 200 and 150, respectively. These new WFC3 SEDs overlap existing CALSPEC Space Telescope Imaging Spectrograph (STIS) standard star flux distributions at 0.8–1 μm with agreement to ≲1%. Some CALSPEC standards already have near-IR camera and multi-object spectrogragh (NICMOS) SEDs; but in their overlap region at 0.8–1.7 μm, the WFC3 data have better wavelength accuracy, better spectral resolution, better repeatability, and, consequently, better flux distributions of ~1% accuracy in our CALSPEC absolute flux SEDs versus ~2% for NICMOS. With the improved SEDs in the WFC3 range, the modeled extrapolations to 32 μm for the James Webb Space Telescope flux standards begin to lose precision longward of the 1.7 μm WFC3 limit, instead of at the 1.0-μm-long wavelength limit for STIS. For example, the extrapolated IR flux longward of 1.7 μm for 1808347 increases by ~1% for the model fit to the data with WFC3, instead of just to the STIS SED alone.

79 ASTRONOMY AND ASTROPHYSICS↗

Point Cloud of Cloud Points PCCP from CACTI Stereo Cameras

The Point Cloud of Cloud Points (PCCP) data set is composed of 3D coordinates describing the position of cloud features and images from which these coordinates are reconstructed. Images are captured in the daytime by two ARM cloud digital cameras (ACDCs) at CACTI S4a and S4b sites, at 20-second intervals. The two cameras are located at 32.1274oS,64.7139oW, and 32.1185oS, 64.7237oW. The 3D positions are detected with respect to the AMF base location at 32.1264oS, 64.7284oW, and 1141 m above sea level. The PCCP data format is the same as explained in PCCP VAP Technical Report.

54 ENVIRONMENTAL SCIENCES↗

The LSST Camera (LSSTCam)

The LSST Camera is the sole instrument for the NSF-DOE Vera C. Rubin Observatory and consists of a 3.2 gigapixel focal plane mosaic with in-vacuum controllers, dedicated guider and wavefront CCDs, a three-element corrector whose largest lens is 1.55m in diameter, six optical interference filters covering a 320-1050nm band pass with an out-of-plane filter exchange mechanism, and camera slow control and data acquisition systems capable of digitizing each image in 2 seconds.

79 ASTRONOMY AND ASTROPHYSICS↗

Gas pressure feeds film into camera at high speed

Blast of gas blows a loop of unexposed film as a wave across a vacuum platen to feed film smoothly into a camera so that 2 successive lengths can be exposed within 50 milliseconds. This technique can be readily applied to multiple aperture cameras as well as to various types of films.

Keigher, P. J.↗

New camera tube improves ultrasonic inspection system

Electron multiplier, incorporated into the camera tube of an ultrasonic imaging system, improves resolution, effectively shields low level circuits, and provides a high level signal input to the television camera. It is effective for inspection of metallic materials for bonds, voids, and homogeneity.

Berger, H.↗

High-speed camera synchronization

Photoelectric sensor enables synchronization of the rotating mirror in a high-speed framing camera with the passage of a very-high-velocity droplet to obtain direct photographic data on droplet breakup. It detects droplet movement across a high intensity light beam and generates a signal triggering the camera.

Rojec, E. A.↗

Modified camera records lens settings on film

Camera is modified by inserting optical imaging system between lens and film. This system requires no electrical power, is low in weight, and adds nothing to external size of the camera.

Thompson, R. E.↗

Test and Evaluation of the Surveyor 3 Television Camera Returned from the Moon by Apollo 12

Results are presented of engineering tests of the Surveyor III television camera, which resided on the moon for 2 and 1/2 years before being brought back to earth by the Apollo XII astronauts. Electric circuits, electrical, mechanical, and optical components and subsystems, the vidicon tube, and a variety of internal materials and surface coatings were examined to determine the effects of lunar exposure. Anomalies and failures uncovered were analyzed. For the most part, the camera parts withstood the extreme environment exceedingly well except where degradation of obsolete parts or suspect components had been anticipated. No significant evidence of cold welding was observed, and the anomalies were largely attributable to causes other than lunar exposure. Very little evidence of micrometeoroid impact was noted. Discoloration of material surfaces -- one of the major effects noted--was found to be due to lunar dust contamination and radiation damage. The extensive test data contained in this report are supplemented by results of tests of other Surveyor parts retrieved by the Apollo XII astronauts, which are contained in a companion report.

Source record↗

Comparison of photogrammetric and astrometric data reduction results for the wild BC-4 camera

The results of astrometric and photogrammetric plate reduction techniques for a short focal length camera are compared. Several astrometric models are tested on entire and limited plate areas to analyze their ability to remove systematic errors from interpolated satellite directions using a rigorous photogrammetric reduction as a standard. Residual plots are employed to graphically illustrate the analysis. Conclusions are made as to what conditions will permit the astrometric reduction to achieve comparable accuracies to those of photogrammetric reduction when applied for short focal length ballistic cameras.

Hornbarger, D. H.↗

A math model for high velocity sensoring with a focal plane shuttered camera.

A new mathematical model is presented which describes the image produced by a focal plane shutter-equipped camera. The model is based upon the well-known collinearity condition equations and incorporates both the translational and rotational motion of the camera during the exposure interval. The first differentials of the model with respect to exposure interval, delta t, yield the general matrix expressions for image velocities which may be simplified to known cases. The exposure interval, delta t, may be replaced under certain circumstances with a function incorporating blind velocity and image position if desired. The model is tested using simulated Lunar Orbiter data and found to be computationally stable as well as providing excellent results, provided that some external information is available on the velocity parameters.

Morgan, P.↗

Automatic focus control for facsimile camera

Focus control performs function of automatically focusing facsimile camera throughout object field being scanned. It does this by determining and adjusting focus of imaging sensor accordingly. Since facsimile camera images a scene by scanning discrete strips, it is possible to have entire three-dimensional scene in perfect focus at point of imaging by use of focus control.

Sinclair, A. R.↗

OTV camera reference handbook Skylab/ASTP

Definition is made of all television camera locations as well as the specific area to be covered by each camera to provide the television coverage of Skylab testing and launches in accordance with operational and engineering requirements.

Source record↗

Multispectral image dissector camera flight test

It was demonstrated that the multispectral image dissector camera is able to provide composite pictures of the earth surface from high altitude overflights. An electronic deflection feature was used to inject the gyro error signal into the camera for correction of aircraft motion.

Johnson, B. L.↗