Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Neutron counting exercises

The neutron counting experiments are divided into three sessions: the first is on determining detector parameters, the second on detector calibration and verification, and the third on verification of impure materials. All of the techniques that we will look at require isotopics to calculate the total plutonium mass of the system. These will be provided for these three exercises.

Geist, William H.↗

Determination of the standard deviation on multiplication based on count distributions

The multiplication M of a multiplying object can be determined by analyzing the arrival times of thermal neutrons in detectors such as helium tubes. A source emitting neutrons randomly will lead to neutron inter arrival times obeying Poisson process statistics. By observing how the inter arrival times of detected counts differ from Poisson statistics, one can assess properties of the neutron source such as the source intensity and multiplication.The results of this study show that analyzing the data stream using non-overlapping time gates is an improvement over the current analysis using overlapping time gates. The new method enables us to compute the standard deviation on the multiplication parameter M accurately. Also, this standard deviation on M decreases as the largest time gate is about 10 times the characteristic time constant λ -1 of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial Multiplication Model as an alternative to the Point Model in Neutron Multiplicity Counting

The point model is commonly used in neutron multiplicity counting to relate the correlated neutron detection rates (singles, doubles, triples) to item properties (mass, (α,n) reaction rate and neutron multiplication). The point model assumes that the probability that a neutron will induce fission is a constant across the physical extent of the item. However, in reality, neutrons near the center of an item have a greater probability of inducing fission then items near the edges. As a result, the neutron multiplication has a spatial distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New-Generation Thermal Neutron Detectors and Electronics for High-Count-Rate Applications

Neutron measurements are important in many nonproliferation and treaty verification applications. Helium-3 proportional counters and analog electronics are the backbone of neutron detection systems. Helium-3 tubes with a 1-in. diameter have been used with classical electronics for over three decades because of the almost ideal behavior of the 3 He tube as a neutron detector. However, some demanding applications of 3 He tubes (high gamma dose rate, high count rate) and the use of non-ideal detectors (such as 10 B-lined proportional counters) mean that the limitations of these conventional systems are being reached. For example, neutron multiplicity deadtime corrections can be large, and some applications have had trouble with multiple pulsing. Also, instrumentation designs for spent fuel applications often rely on large amounts of lead shielding to reduce the gamma dose at the detector location, making them heavy and expensive. This major challenge for a short dead time and operation in high gamma fields is difficult to address by simply changing the gas admixture and tweaking the shaper time constants. Those small gains are adequate for measurements of some lower-burn-up, low-enrichment-uranium spent fuel assemblies, but not for mixed oxide (MOX) fuel or advanced fast reactor fuel, where the neutron source term is greater.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distinguishing Pu Metal from Pu Oxide and Determining α-ratio using Fast Neutron Counting

We describe a new method for determining the ratio of the rate of (α, n) source neutrons to the rate of spontaneous fission neutrons, the so called α-ratio. This method is made possible by fast neutron counting with liquid scintillator detectors, which can determine the shape of the fast neutron spectrum. The method utilizes the spectral difference between fission spectrum neutrons from Pu metal and the spectrum of (α, n) neutrons from PuO 2 . Our method is a generalization of the Cifarelli-Hage method for determining k eff for fissile assemblies, and also simultaneously determines k eff along with the α-ratio.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A new method of passive counting of nuclear missile warheads -a white paper for the Defense Threat Reduction Agency

Cosmic ray muon imaging has been studied for the past several years as a possible technique for nuclear warhead inspection and verification as part of the New Strategic Arms Reduction Treaty between the United States and the Russian Federation. The Los Alamos team has studied two different muon imaging methods for this application, using detectors on two sides and one side of the object of interest. In this report we present results obtained on single sided imaging of configurations aimed at demonstrating the potential of this technique for counting nuclear warheads in place with detectors above the closed hatch of a ballistic missile submarine.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Implementation and Initial Testing of Advanced Processing and Analysis Algorithms for Correlated Neutron Counting

In order to improve the accuracy and capabilities of neutron multiplicity counting, additional quantifiable information is needed in order to address the assumptions that are present in the point model. Extracting and utilizing higher order moments (Quads and Pents) from the neutron pulse train represents the most direct way of extracting additional information from the measurement data to allow for an improved determination of the physical properties of the item of interest. The extraction of higher order moments from a neutron pulse train required the development of advanced dead time correction algorithms which could correct for dead time effects in all of the measurement moments in a self-consistent manner. In addition, advanced analysis algorithms have been developed to address specific assumptions that are made within the current analysis model, namely that all neutrons are created at a single point within the item of interest, and that all neutrons that are produced within an item are created with the same energy distribution. This report will discuss the current status of implementation and initial testing of the advanced dead time correction and analysis algorithms that have been developed in an attempt to utilize higher order moments to improve the capabilities of correlated neutron measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2014-2016 Avian Point Count and Migration Surveys at Site 300 for the Lawrence Livermore National Laboratory

The primary goals of the surveys were to: 1) collect minutes of bird activity within Site 300, 2) consider relative abundance of the different bird species occurring within the Site, 3) collect behavioral information, and 4) provide compelling evidence to determine the status of the Site as a migration corridor or migration stopover site. To this end, two survey types were conducted: avian point counts were conducted on a monthly basis from February 2014 through January 2016 and migration surveys were conducted over two three-month periods from September 2014 through November 2014, and September 2015 through November 2015. These two surveys types provided the opportunity to observe avian species in a variety of conditions across a two year period. Whenever possible or relevant, the observations of either survey were used to inform and complement the observations of the other survey in pursuit of the above goals. Both survey types are described below.

54 ENVIRONMENTAL SCIENCES↗

FY16 ISCP Nuclear Counting Facility Hardware Expansion Summary

Hardware expansion and detector calibrations were the focus of FY 16 ISCP efforts in the Nuclear Counting Facility. Work focused on four main objectives: 1) Installation, calibration, and validation of 4 additional HPGe gamma spectrometry systems; including two Low Energy Photon Spectrometers (LEPS). 2) Re-Calibration and validation of 3 previously installed gamma-ray detectors, 3) Integration of the new systems into the NCF IT infrastructure, and 4) QA/QC and maintenance of current detector systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Throughput Method of Extracting and Counting Strontium-90 in Urine

A method has been developed for the rapid extraction of Sr-90 from the urine of individuals exposed to radiation in a terrorist attack. The method employs two chromatographic ion-exchange materials: Diphonix resin and Sr resin, both of which are commercially available. The Diphonix resin reduces the alkali ion concentrations below 10 mM, and the Sr resin concentrates and decontaminates strontium-90. Experimental and calculational data are given for a variety of test conditions. On the basis of these results, a flowsheet has been developed for the rapid concentration and extraction of Sr-90 from human urine samples for subsequent beta-counting.

61 RADIATION PROTECTION AND DOSIMETRY↗

RCT: Module 2.03, Counting Errors and Statistics, Course 8768

Radiological sample analysis involves the observation of a random process that may or may not occur and an estimation of the amount of radioactive material present based on that observation. Across the country, radiological control personnel are using the activity measurements to make decisions that may affect the health and safety of workers at those facilities and their surrounding environments. This course will present an overview of measurement processes, a statistical evaluation of both measurements and equipment performance, and some actions to take to minimize the sources of error in count room operations. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and by providing in the field skills.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-State Neutron Multiplicity Counting System Using Commercial Off-the-Shelf Semiconductor Detectors

This work iterates on the first demonstration of a solid-state neutron multiplicity counting system developed at Lawrence Livermore National Laboratory by using commercial off-the-shelf detectors. The system was demonstrated to determine the mass of a californium-252 neutron source within 20% error requiring only one-hour measurement time with 20 cm 2 of active detector area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report on Task USA A 0931 (A.252) Implementation of Fast, Front-End Electronics for Improved Low-Dead Time Neutron Counting

The International Atomic Energy Agency's (IAEA) Department of Safeguards is working on the elaboration and implementation of advanced Non-Destructive Assay (NDA) methods, generally known as neutron noise analysis, for the verification of critical and sub-critical cores containing substantial quantities of direct use nuclear material. These verification methods rely on interpreting time properties of the neutron multiplication process, which are to be extracted from measured neutron pulse trains. The interpretations are highly dependent on the quality of the measured data, which is directly related to the capability of an employed neutron detector to resolve very close detection events originating from neutron bursts produced in a highly multiplying medium. Therefore, the application of detectors with minimum dead-time, pile-up, and other distortion effects is required. This report describes the work under Task USA A 0931 (A.252 Implementation of fast, front-end electronics for improved low-dead time neutron counting).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing Minimum Detectable Activity of Whole-Body Counting System in the Presence of Interfering Factors

The recently updated technical standard for the Department of Energy Laboratory Accreditation Program (DOELAP) may soon require accredited laboratories to empirically verify the estimated minimum detectable activity (MDA) for the nuclides of interest measured by in-vivo detection systems. The Radiation Protection Sample Diagnostics (RPSD) program is the SNL on-site DOELAP accredited laboratory that provides in-vivo measurements of ingested gamma-emitting nuclides (or to prove the lack of significant ingested gamma-emitting nuclides) for the internal dosimetry program administered by Radiation Protection Dosimetry Program (RPDP). Currently, the main nuclides of concern for RPDP include cesium-137 and cobalt-60 as specified in the Statement of Work between the two programs. Historically, MDAs for the RPSD whole-body counting system (WBC) were calculated annually as a-priori values by averaging the critical levels (LC) of any twelve subjects with undetected Co-60 and Cs-137 and assuming MDA is twice the decision level. The purpose of this technical basis document is to evaluate the method and process that validates the a-priori MDA of the RPSD WBC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron Multiplicity Counting Diagnosis of Uranium Assemblies Interrogated by Cf-252 [Poster]

Researchers concluded: First neutron multiplicity counting of tens of kilograms of 235 U with organic scintillators; leakage multiplication estimates to be improved by incorporating detector cross-talk; provides data comparison for “Multiplicity Theory Beyond the Point Model;" promotes continued use of organic scintillators for NCERC and elsewhere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modification of a Silicon Photomultiplier for Reduced High Temperature Dark Count Rate

In this work we present a novel method for improving the high-temperature performance of silicon photomultipliers (SiPMs) via focused ion beam (FIB) modification of individual microcells. The literature suggests that most of the dark count rate (DCR) in a SiPM is contributed by a small percentage (<5%) of microcells. By using a FIB to electrically deactivate this relatively small number of microcells, we believe we can greatly reduce the overall DCR of the SiPM at the expense of a small reduction in overall photodetection efficiency, thereby improving its high temperature performance. In this report we describe our methods for characterizing the SiPM to determine which individual microcells contribute the most to the DCR, preparing the SiPM for FIB, and modifying the SiPM using the FIB to deactivate the identified microcells.

42 ENGINEERING↗