Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Permeable Reactive Biobarriers for In Situ Cr(VI) Reduction: Bench Scale Tests Using Cellulomonas sp. Strain ES6

Chromate (Cr(VI)) reduction studies were performed in bench scale flow columns using the fermentative subsurface isolate Cellulomonas sp. strain ES6. In these tests, columns packed with either quartz sand or hydrous ferric oxide (HFO)-coated quartz sand, were inoculated with strain ES6 and fed nutrients to stimulate growth before nutrient-free Cr(VI) solutions were injected. Results show that in columns containing quartz sand, a continuous inflow of 2 mg/L Cr(VI) was reduced to below detection limits in the effluent for durations of up to 5.7 residence times after nutrient injection was discontinued proving the ability of strain ES6 to reduce chromate in the absence of an external electron donor. In the HFO-containing columns, Cr(VI) reduction was significantly prolonged and effluent Cr(VI) concentrations remained below detectable levels for periods of up to 66 residence times after nutrient injection was discontinued. Fe was detected in the effluent of the HFO-containing columns throughout the period of Cr(VI) removal indicating that the insoluble Fe(III) bearing solids were being continuously reduced to form soluble Fe(II) resulting in prolonged abiotic Cr(VI) reduction. Thus, growth of Cellulomonas within the soil columns resulted in formation of permeable reactive barriers that could reduce Cr(VI) and Fe(III) for extended periods even in the absence of external electron donors. Other bioremediation systems employing Fe(II)-mediated reactions require a continuous presence of external nutrients to regenerate Fe(II). After depletion of nutrients, contaminant removal within these systems occurs by reaction with surface-associated Fe(II) that can rapidly become inaccessible due to formation of crystalline Fe-minerals or other precipitates. The ability of fermentative organisms like Cellulomonas to reduce metals without continuous nutrient supply in the subsurface offers a viable and economical alternative technology for in situ remediation of Cr(VI)-contaminated groundwater through formation of permeable reactive biobarriers (PRBB).

54 ENVIRONMENTAL SCIENCES↗

Green and Cost Effective Synthesis of Fluorescent Carbon Quantum Dots for Dopamine Detection

Carbon quantum dots (CQDs) due to its high fluorescent output is evolving as novel sensing material and is considered as future building blocks for nano sensing devices. Hence, in this investigation we report microwave assisted preparation and multi sensing application of CQDs. The microwave derived CQDs are characterized by Dynamic Light Scattering (DLS) experiment and Fourier Infrared spectra (FTIR) to investigate the size distribution and chemical purity respectively. Fluorescent emission spectra recorded at varying pH shows varying fluorescence emission intensities. Further, emission spectra recorded at different temperatures shows that fluorescence emission of CQDs greatly depends on temperature. Therefore, we demonstrate the pH and temperature sensing characteristics of CQDs by fluorescence quenching behaviour. In addition, the interaction and sensing behaviour of CQDs for dopamine is also presented in this work with a detection limit of 0.2 mM. The steady state and time-resolved methods have been employed in fluorescence quenching methods for sensing dopamine through CQDs at room temperature. The bimolecular quenching rate constants for different concentration have been measured. The interaction between CQDs and dopamine indicates fluorescence quenching method is an elegant process for detecting dopamine through CQDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A BODIPY Based Fluorescent Probe for the Rapid Detection of Hypochlorite

A new boron-dipyrromethene (BODIPY) fluorescent dye aimed at sensitively detecting hypochlorite anion (ClO{sup −}) has been designed, synthesized and characterized. The probe is comprised of a BODIPY fluorophore unit and a ClO{sup −} specific reactive group of amidoxime. The addition of hypochlorite results in a red-shift of absorption and emission spectra of the probe accompanied by a decrease of intensity and spectra changes (A{sub 500} and 1/I{sub 512}) of the probe can achieve a good linearity to the concentration of ClO{sup −}. The fluorescence probe can react to ClO{sup −} rapidly (within 60 s) in a wide pH range (4–10) with high sensitivity (detection limit of 6.81 μM) and selectivity. The reaction mechanism has been proposed and confirmed by MS analysis, ClO{sup −} anion oxidizes amidoxime moiety to hydroxyl group and hydroxyl group is further oxidized to formyl group in the formation of a corresponding aldehyde compound. In addition, the probe has also been successfully applied to detect ClO{sup −} in tap water and river water samples by spiking a known amount of standard ClO{sup −}.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Subaru/ XMM-Newton Deep Survey (SXDS). V. Optically Faint Variable Object Survey

We present our survey for optically faint variable objects using multiepoch (8-10 epochs over 2-4 years) i'-band imaging data obtained with Subaru Suprime-Cam over 0.918 deg 2 in the Subaru/ XMM-Newton Deep Field (SXDF). We found 1040 optically variable objects by image subtraction for all the combinations of images at different epochs. This is the first statistical sample of variable objects at depths achieved with 8-10 m class telescopes or the Hubble Space Telescope. The detection limit for variable components is i' vari &sim; 25.5 mag. These variable objects were classified into variable stars, supernovae (SNe), and active galactic nuclei (AGNs), based on the optical morphologies, magnitudes, colors, and optical-mid-infrared colors of the host objects, spatial offsets of variable components from the host objects, and light curves. Detection completeness was examined by simulating light curves for periodic and irregular variability. We detected optical variability for 36% ± 2% (51% ± 3% for a bright sample with i' < 24.4 mag) of X-ray sources in the field. Number densities of variable objects as functions of time intervals Δ t and variable component magnitudes i' vari are obtained. Number densities of variable stars, SNe, and AGNs are 120, 489, and 579 objects deg -2 , respectively. Bimodal distributions of variable stars in the color-magnitude diagrams indicate that the variable star sample consists of bright (V &sim; 22 mag) blue variable stars of the halo population and faint (V &sim; 23.5 mag) red variable stars of the disk population. Lastly, there are a few candidates of RR Lyrae providing a possible number density of &sim;10 -2 kpc -3 at a distance of >150 kpc from the Galactic center.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopic search for optical emission lines from dark matter decay

We search for narrow-line optical emission from dark matter decay by stacking dark-sky spectra from the Dark Energy Spectroscopic Instrument (DESI) at the redshift of nearby galaxies from DESI’s Bright Galaxy and Luminous Red Galaxy samples. Our search uses regions separated by 5 to 20 arcsec from the centers of the galaxies, corresponding to an impact parameter of approximately 50 kpc. No unidentified spectral line shows up in the search, and we place a line flux limit of 10 −19 ergs/s/cm 2 /arcsec 2 on emissions in the wavelength range of 2000–9000⁢ Å. This places the tightest constraints yet on the two-photon decay of dark matter in the mass range of 5 to 12 eV, with a particle lifetime exceeding 3 × 10 25 s. Furthermore, this detection limit also implies that the line surface brightness contributed from all dark matter along the line of sight is at least 2 orders of magnitude lower than the measured extragalactic background light (EBL), ruling out the possibility that narrow optical-line emission from dark matter decay is a major source of the EBL.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an X-ray surface analyzer for planetary exploration

An ultraminiature X-ray fluorescence spectrometer was developed which can obtain data on element composition not provided by present spacecraft instrumentation. The apparatus employs two radioisotope sources (Fe-55 and Cd-109) which irradiate adjacent areas on a soil sample. Fluorescent X-rays emitted by the sample are detected by four thin-window proportional counters. Using pulse-height discrimination, the energy spectra are determined. Virtually all elements above sodium in the periodic table are detected if present at sufficient levels. Minimum detection limits range from 30 ppm to several percent, depending upon the element and the matrix. For most elements, they are below 0.5 percent. Accuracies likewise depend upon the matrix, but are generally better than plus or minus 0.5 percent for all elements of atomic number greater than 14. Elements below sodium are also detected, but as a single group.

Clark, B. C.↗

A very deep IRAS survey at l(II) = 97 deg, b(II) = +30 deg

A deep far-infrared survey is presented using over 1000 scans made of a 4 to 6 sq. deg. field at the north ecliptic pole by the IRAS. Point sources from this survey are up to 100 times fainter than the IRAS point source catalog at 12 and 25 micrometers, and up to 10 times fainter at 60 and 100 micrometers. The 12 and 25 micrometer maps are instrumental noise-limited, and the 60 and 100 micrometer maps are confusion noise-limited. The majority of the 12 micrometer point sources are stars within the Milky Way. The 25 micrometer sources are composed almost equally of stars and galaxies. About 80% of the 60 micrometer sources correspond to galaxies on Palomar Observatory Sky Survey (POSS) enlargements. The remaining 20% are probably galaxies below the POSS detection limit. The differential source counts are presented and compared with what is predicted by the Bahcall and Soneira Standard Galaxy Model using the B-V-12 micrometer colors of stars without circumstellar dust shells given by Waters, Cote and Aumann. The 60 micrometer source counts are inconsistent with those predicted for a uniformly distributed, nonevolving universe. The implications are briefly discussed.

Hacking, Perry↗

Characterisation of graphite using boron as a marker element

Graphite has many industrial applications. Two of the most important applications are as electrodes in industries and as moderator in nuclear industry. Determination of the Boron Equivalent of the impurity elements in graphite is the most important parameter for certifying the grade of graphite electrode [1]. The use of a suitable method with low limits of determination of boron is therefore necessary. A method has been standardised in Analytical Chemistry Division, BARC for determining trace amounts of boron in graphite electrodes. It involves controlled dissolution of graphite sample powder and measurement of boron by Inductively Coupled Plasma Mass Spectrometer (ICP-MS) using matrix matched standards. The method detection limit is 1 {mu}g g{sup -1}. The method Relative Standard Deviation was 5%. The method was verified by spike recovery experiments. Recoveries were found to be within 100{+-}2% in the concentration range of 1 to 100 {mu}g g{sup -1}. The developed method has been adopted for the compositional characterization of several graphite electrode samples.

36 MATERIALS SCIENCE↗

Most sub-arcsecond companions of Kepler exoplanet candidate host stars are gravitationally bound

Using the known detection limits for high-resolution imaging observations and the statistical properties of true binary and line-of-sight companions, we estimate the binary fraction of Kepler exoplanet host stars. Our speckle imaging programs at the WIYN 3.5 m and Gemini North 8.1 m telescopes have observed over 600 Kepler objects of interest and detected 49 stellar companions within ∼1 arcsec. Assuming binary stars follow a log-normal period distribution for an effective temperature range of 3000-10,000 K, then the model predicts that the vast majority of detected sub-arcsecond companions are long period (P > 50 yr), gravitationally bound companions. In comparing the model predictions to the number of real detections in both observational programs, we conclude that the overall binary fraction of host stars is similar to the 40%-50% rate observed for field stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Some final conclusions and supporting experiments related to the search for organic compounds on the surface of Mars

The Viking molecular analysis experiment has demonstrated the absence (within the detection limits which range from levels of parts per million to below parts per billion) of organic substances in the Martian surface soil at the two Viking landing sites. Laboratory experiments with sterile and nonsterile antarctic samples further demonstrate the capability and reliability of the instrument. The circumstances under which organic components could have escaped detection, such as inaccessibility or extreme thermal stability of organic polymers, are discussed but are found to be unlikely. The inability of the instrument to detect free oxygen evolved from soil samples is pointed out.

Biemann, K.↗

A search at the millijansky level for milli-arcsecond cores in a complete sample of radio galaxies

A complete sample of 26 extended radio galaxies was observed at 2.29 GHz with the Mark III VLBI system. The fringe spacing was about 3 milli-arcsec, and the detection limit was about 2 millijanskys. Half of the galaxies were found to possess milli-arcsec radio cores. In all but three sources, the nuclear flux density was less than 0.04 of the total flux density. Galaxies with high optical luminosity (less than -21.2) were more likely than less luminous galaxies to contain a detectable milliparcsec radio core (69 percent vs. 20 percent). For objects with arcsec cores, 80 percent were found to have a milli-arcsec core, even though the milli-arcsec object did not always contribute the greater part of the arcsec flux density.

Wehrle, A. E.↗

Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform

In this work, a poly(dimethylsiloxane) (PDMS) microchip-based immuno-sensing platform with integrated pneumatic micro valves is described. The microchip was fabricated with multiple layer soft lithography technology. By controlling the activation status of corresponding valves, reagent flows in the microchannel network can be well manipulated so that immuno-reactions only take place at designated reaction zones (DRZs). Four DRZs are included in the prototype microchip. Since these DRZs are all isolated from each other by micro valves, cross contamination is prevented. Using the inner surface of the all-PDMS microchannel as immunoassay substrate, on-chip sandwich format solid phase immunoassay was performed to demonstrate the feasibility of this immuno-sensing platform. Mouse IgG and fluorescein isothiocyanate (FITC) were used as the model analyte and the signal reporter respectively. Only 10 ul sample is needed for the assay and low detection limit of 5 ng/ml (≈33 pM) was achieved though low-cost polyclonal antibodies were used in our experiment for feasibility study only. The encouraging results from mouse IgG immunoassay proved the feasibility of our microchip design. With slight modification of the assay protocol, the same chip design can be used for multi-target detection and can provide a simple, cost-effective and integrated microchip solution for multiplex immunoassay applications.

60 APPLIED LIFE SCIENCES↗

Resonance Raman and surface- and tip-enhanced Raman spectroscopy methods to study solid catalysts and heterogeneous catalytic reactions.

Resonance Raman (RR) spectroscopy has several advantages over the normal Raman spectroscopy (RS) widely used for in situ characterization of solid catalysts and catalytic reactions. Compared with RS, RR can provide much higher sensitivity and selectivity in detecting catalytically-significant surface metal oxides. RR can potentially give useful information on the nature of excited states relevant to photocatalysis and on the anharmonic potential of the ground state. In this critical review a detailed discussion is presented on several types of RR experimental systems, three distinct sources of so-called Raman (fluorescence) background, detection limits for RR compared to other techniques (EXAFS, PM-IRAS, SFG), and three well-known methods to assign UV-vis absorption bands and a band-specific unified method that is derived mainly from RR results. In addition, the virtues and challenges of surface-enhanced Raman spectroscopy (SERS) are discussed for detecting molecular adsorbates at catalytically relevant interfaces. Tip-enhanced Raman spectroscopy (TERS), which is a combination of SERS and near-field scanning probe microscopy and has the capability of probing molecular adsorbates at specific catalytic sites with an enormous surface sensitivity and nanometre spatial resolution, is also reviewed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative chemical assay of nanogram-level particulate matter using aerosol mass spectrometry: characterization of particles collected from uncrewed atmospheric measurement platforms

Abstract. Aerosol generation techniques have expanded the utility of aerosol mass spectrometry (AMS) for offline chemical analysis of airborne particles and droplets. However, standard aerosolization techniques require relatively large liquid volumes (e.g., several milliliters) and high sample masses that limit their utility. Here we report the development and characterization of a micronebulization AMS (MN-AMS) technique that requires as low as 10 µL of sample and can provide the quantification of the nanogram level of organic and inorganic substances via the usage of an isotopically labeled internal standard (34SO42-). Using standard solutions, the detection limits for this technique were determined at 0.19, 0.75, and 2.2 ng for sulfate, nitrate, and organics, respectively. The analytical recoveries for these species are 104 %, 87 %, and 94 %, respectively. This MN-AMS technique was applied successfully to analyze filter and impactor samples collected using miniature particulate matter (PM) samplers deployable on uncrewed atmospheric measurement platforms, such as uncrewed aerial systems (UASs) and tethered balloon systems (TBSs). Chemical composition of PM samples collected from a UAS field campaign conducted at the Department of Energy's (DOE) Southern Great Plains (SGP) observatory was characterized. The offline MN-AMS data compared well with the in situ PM composition measured by a co-located aerosol chemical speciation monitor (ACSM). In addition, the MN-AMS and ion chromatography (IC) agreed well for measurements of sulfate and nitrate concentrations in the PM extracts. This study demonstrates the utility of combining MN-AMS with uncrewed measurement platforms to provide quantitative measurements of ambient PM composition.

54 ENVIRONMENTAL SCIENCES↗

Sensitive Immunoassays of Nitrated Fibrinogen in Human Biofluids

Three new sandwich immunoassays for detection of nitrated biomarker have been established with potential applications in biomedical studies and clinical practice. In this study, nitrated human fibrinogen, a potential oxidative stress biomarker for several pathologies, was chosen as the target. To improve the sensitivity and overcome the interference caused by the complexity of human biofluids, we developed three sandwich strategies using various combinations of primary antibody and secondary antibody. All three strategies demonstrated high sensitivity and selectivity towards nitrated forms of fibrinogen in buffer, but their performances were dramatically reduced when tested with human plasma and serum samples. Systematically optimizations were carried out to investigate the effects of numerous factors, including sampling, coating, blocking, and immunoreactions. Our final optimization results indicate that two of these strategies retain sufficient sensitivity and selectivity for use as assays in human physiological samples. Specifically, detection limits reached the pM level and the linear response ranges were up to nM level with a correlation coefficient > 0.99. To our best knowledge, this is the first example of using an electrochemical immunoassay for a nitrated biomarker in a physiological fluid. This novel approach provides a rapid, sensitive, selective, cost efficient and robust bioassay for detection of oxidative stress in pathology and for clinical applications. Moreover, the sandwich strategies developed in this paper can be readily used to establish effective methods targeting other nitration biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Direct-Push Vadose Zone Sediments from the 241-B and 241-BX Tank Farms

Geochemical tests provide evidence for the transit of a plume of caustic waste solution through the sediment column at the Hanford 241-B and -BX Tank Farms. Direct-push samples recovered from boreholes surrounding Tanks 241-B-110 and 241-BX-102 and related waste transfer lines and diversion boxes included sediments typical of those previously recovered from other localities on the Hanford Site. The Hanford formation sediments are dominantly quartzo-feldspathic sands strewn with lithic fragments, displaying a range of particle size distributions and sorting characteristics. Some moderately well-sorted, fine-grained lithologies are interpreted as lenticular bodies irregularly dispersed in coarser-grained, more poorly sorted sediments. Tier I tests conducted on the vadose zone sediments revealed an inverse correlation between moisture content and sediment size fraction (i.e., there is greater moisture content in finer-grained sediments). The Tier I tests also showed that the pore water solutions were likely sodium-rich, moderately saline, and possessed higher pH values than background (untainted) sediments. These data are characteristic of sediments that have encountered sodium-rich, saline, caustic waste solution, as documented in other reports at other suspect contamination sites around Hanford. Analyses of solutions from 1:1 water extracts reveal relatively balanced cation and anion concentrations, indicating that most of the geochemical species have been accounted for. The water extract data for affected sediments also indicate unusually high concentrations of aluminum, iron, and phosphorus. The relatively high concentrations of aluminum and iron may be the result of dissolution of secondary amorphous phases that precipitated after a reactive plume partially dissolved aluminum- and iron-bearing phases as it migrated through the sediment column. On the other hand, the presence of elevated concentrations of phosphorous may be the tell-tale signature of wastes derived from the bismuth phosphate separation process. Elements typically mobile in the geosphere, such as technetium-99, are present at either low concentrations or are below the analytical detection limit. However, we expect that the mobile elements would be present mainly along a narrow plume front, and if this front had passed deeper into the sediment profile than depths sampled, the retention of these elements would be minor. On the other hand for the direct push sediments from around BX Tank Farm, uranium-238 was detected in nearly all sediment specimens (by acid extract experiments) at concentrations above the natural crustal average (0.763 pCi/g), and we also detected the presence of several anthropogenic radioisotopes, such as cobalt-60, cesium-137, europium-154, and europium-155 (by gamma energy analysis). These data are direct confirmation of contamination of the sediments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stellar photometry in the inner bulge of M31 using the Hubble Space Telescope wide field camera

We present photometry of two fields in the M31 bulge imaged with the Hubble Space Telescope (HST) Wide-Field Camara (WFC). The nuclear field (r less than 40 arcsecs = 150 pc) giant branch extends to I = 19.5, M(sub I) = -5 (Cousins system), a full 0.9 mag brighter than the giant-branch tips of metal-poor Galactic globular clusters and M31 halo fields. This is also approximately = 1.5 mag brighter than the giant branches of metal-rich Galactic globular clusters, but is no brighter than Mould's (1986) M31 bulge field 1 kpc from the nucleus. The data also suggest that the brighter stars may be preferentially concentrated to the center. The 648 luminous stars detected in 2 x 10(exp 9) solar luminosity is approximately = 25% that expected from a hypothetical population of evolved asymptotic giant branch (AGB) stars with lifetimes approximately = 10(exp 5) yr, with the cautionary note that we are near the detection limit. The number of bright stars is also consistent with the progeny of blue stragglers, if one uses a lifetime for the thermal-pulsing AGB of 2 x 10(exp 6) yr. We strongly caution that incompleteness becomes severe below I = 19.9 mag and that future surveys are likely to find numbers of bright stars too large to accomodate the blue straggler progeny hypothesis. We have imaged an additional field 2 arcmin = 500 pc south of the nucleus. The brightest stars in this field are also I = 19.5, but bright stars appear less numerous than in the nuclear field. If the population resembles that of the Galactic bulge, then M(sub bol) = -4.5 is a lower limit to the giant-branch tip luminosity; infrared studies should reveal stars 0.5 mag or more brighter. Either high-metallicity or (more likely) age approximately = 10 Gyr may be responsible for the presence of these luminous AGB stars. These observations confirm that previous ground-based infrared studies (e.g., Rich & Mould 1991) very likely detect an extended giant branch and not spurious luminous stars caused by crowding or disk contamination. However, published integrated colors for the M31 bulge/nucleus are extremely red, making it difficult to accomodate a young or intermediate-age population.

Rich, R. M.↗