Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Impedance-Based Stability Analysis in Grid Interconnection Impact Study Owing to the Increased Adoption of Converter-Interfaced Generators

This study investigates the emerging harmonic stability concerns to be addressed by grid planners in generation interconnection studies, owing to the increased adoption of renewable energy resources connected to the grid via power electronic converters. The wideband and high-frequency electromagnetic transient (EMT) characteristics of these converter-interfaced generators (CIGs) and their interaction with the grid impedance are not accurately captured in the typical dynamic studies conducted by grid planners. This paper thus identifies the desired components to be studied and subsequently develops a practical process for integrating a new CIG into a grid with the existing CIGs. The steps of this process are as follows: the impedance equation of a CIG using its control dynamics and an interface filter to the grid, for example, an LCL filter (inductor-capacitor-inductor type), is developed; an equivalent impedance model including the existing CIGs nearby and the grid observed from the point of common coupling are derived; the system stability for credible operating scenarios is assessed. Detailed EMT simulations validate the accuracy of the impedance models and stability assessment for various connection scenarios. Here, by complementing the conventional EMT simulation studies, the proposed analytical approach enables grid planners to identify critical design parameters for seamlessly integrating a new CIG and ensuring the reliability of the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Frequency Recovery in Power Grids Using High-Performance Computing

Maintaining electric power system stability is paramount, especially in extreme contingencies involving unexpected outages of multiple generators or transmission lines that are typical during severe weather events. Such outages often lead to large supply-demand mismatches followed by subsequent system frequency deviations from their nominal value. The extent of frequency deviations is an important metric of system resilience, and its timely mitigation is a central goal of power system operation and control. This paper develops a novel nonlinear model predictive control (NMPC) method to minimize frequency deviations when the grid is affected by an unforeseen loss of multiple components. Our method is based on a novel multi-period alternating current optimal power flow (ACOPF) formulation that accurately models both nonlinear electric power flow physics and the primary and secondary frequency response of generator control mechanisms. We develop a distributed parallel Julia package for solving the large-scale nonlinear optimization problems that result from our NMPC method and thereby address realistic test instances on existing high-performance computing architectures. Our method demonstrates superior performance in terms of frequency recovery over existing industry practices, where generator levels are set based on the solution of single-period classical ACOPF models.

nonlinear model predictive control↗

Voltage-Load Sensitivity Matrix Based Demand Response for Voltage Control in High Solar Penetration Distribution Feeders

This paper presents a voltage-load sensitivity matrix (VLSM) based voltage control method to deploy demand response resources for controlling voltage in high solar penetration distribution feeders. The IEEE 123-bus system in OpenDSS is used for testing the performance of the preliminary VLSM-based voltage control approach. A load disaggregation process is applied to disaggregate the total load profile at the feeder head to each load nodes along the feeder so that loads are modeled at residential house level. Measured solar generation profiles are used in the simulation to model the impact of solar power on distribution feeder voltage profiles. Different case studies involving various PV penetration levels and installation locations have been performed. Simulation results show that the VLSM algorithm performance meets the voltage control requirements and is an effective voltage control strategy.

distribution system modeling↗

Data-driven cyber attack detection and mitigation for decentralized wide-area protection and control in smart grids

Modern power systems have already evolved into complicated cyber physical systems (CPS), often referred to as smart grids, due to the continuous expansion of the electrical infrastructure, the augmentation of the number of heterogeneous system components and players, and the consequential application of a diversity of information and telecommunication technologies to facilitate the Wide Area Monitoring, Protection and Control (WAMPAC) of the day-to-day power system operation. Because of the reliance on cyber technologies, WAMPAC, among other critical functions, is prone to various malicious cyber attacks. Successful cyber attacks, especially those sabotage the operation of Bulk Electric System (BES), can cause great financial losses and social panics. Application of conventional IT security solutions is indispensable, but it often turns out to be insufficient to mitigate sophisticated attacks that deploy zero-day vulnerabilities or social engineering tactics. To further improve the resilience of the operation of smart grids when facing cyber attacks, it is desirable to make the WAMPAC functions per se capable of detecting various anomalies automatically, carrying out adaptive activity adjustments in time and thus staying unimpaired even under attack. Most of the existing research efforts attempt to achieve this by adding novel functional modules, such as model-based anomaly detectors, to the legacy centralized WAMPAC functions. In contrast, this dissertation investigates the application of data-driven algorithms in cyber attack detection and mitigation within a decentralized architecture aiming at improving the situational awareness and self-adaptiveness of WAMPAC. First part of the research focuses on the decentralization of System Integrity Protection Scheme (SIPS) with Multi-Agent System (MAS), within which the data-driven anomaly detection and optimal adaptive load shedding are further explored. An algorithm named as Support Vector Machine embedded Layered Decision Tree (SVMLDT) is proposed for the anomaly detection, which provides satisfactory detection accuracy as well as decision-making interpretability. The adaptive load shedding is carried out by every agent individually with dynamic programming. The load shedding relies on the load profile propagation among peer agents and the attack adaptiveness is accomplished by maintaining the historical mean of load shedding proportion. Load shedding only takes place after the consensus pertaining to the anomaly detection is achieved among all interconnected agents and it serves the purpose of mitigating certain cyber attacks. The attack resilience of the decentralized SIPS is evaluated using IEEE 39 bus model. It is shown that, unlike the traditional centralized SIPS, the proposed solution is able to carry out the remedial actions under most Denial of Service (DoS) attacks. The second part investigates the clustering based anomalous behavior detection and peer-assisted mitigation for power system generation control. To reduce the dimensionality of the data, three metrics are designed to interpret the behavior conformity of generator within the same balancing area. Semi-supervised K-means clustering and a density sensitive clustering algorithm based on Hierarchical DBSCAN (HDBSCAN) are both applied in clustering in the 3D feature space. Aiming to mitigate the cyber attacks targeting the generation control commands, a peer-assisted strategy is proposed. When the control commands from control center is detected as anomalous, i.e. either missing or the payload of which have been manipulated, the generating unit utilizes the peer data to infer and estimate a new generation adjustment value as replacement. Linear regression is utilized to obtain the relation of control values received by different generating units, Moving Target Defense (MTD) is adopted during the peer selection and 1-dimensional clustering is performed with the inferred control values, which are followed by the final control value estimation. The mitigation strategy proposed requires that generating units can communicate with each other in a peer-to-peer manner. Evaluation results suggest the efficacy of the proposed solution in counteracting data availability and data integrity attacks targeting the generation controls. However, the strategy stays effective only if less than half of the generating units are compromised and it is not able to mitigate cyber attacks targeting the measurements involved in the generation control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ultrahigh Power Factor in Thermoelectric System Nb 0.95 M 0.05 FeSb (M = Hf, Zr, and Ti)

Abstract Conversion efficiency and output power are crucial parameters for thermoelectric power generation that highly rely on figure of merit ZT and power factor (PF), respectively. Therefore, the synergistic optimization of electrical and thermal properties is imperative instead of optimizing just ZT by thermal conductivity reduction or just PF by electron transport enhancement. Here, it is demonstrated that Nb 0.95 Hf 0.05 FeSb has not only ultrahigh PF over ≈100 µW cm −1 K −2 at room temperature but also the highest ZT in a material system Nb 0.95 M 0.05 FeSb (M = Hf, Zr, Ti). It is found that Hf dopant is capable to simultaneously supply carriers for mobility optimization and introduce atomic disorder for reducing lattice thermal conductivity. As a result, Nb 0.95 Hf 0.05 FeSb distinguishes itself from other outstanding NbFeSb‐based materials in both the PF and ZT . Additionally, a large output power density of ≈21.6 W cm −2 is achieved based on a single‐leg device under a temperature difference of ≈560 K, showing the realistic prospect of the ultrahigh PF for power generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Consideration of Decabromodiphenyl Ether Flame Retardant in Thermal and Radiation Aging of Crosslinked Polyethylene Cable Insulation

Decabromodiphenyl ether (decaBDE) has been used as a flame-retardant additive in nuclear-grade electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. On January 6, 2021, the Environmental Protection Agency (EPA) published a final rule to phase out decaBDE. The 2021 rule set a two-year compliance deadline for “processing and distribution in commerce of decaBDE for use in wire and cable insulation in nuclear power generation facilities.” In recognition of industry concerns following a sudden discontinuation of decaBDE-containing Class 1E wire and cable essential for nuclear power operations and the time needed for qualifying the individual components using the alternative insulation technology, an extended compliance deadline was set in the finalized amendments to the 2021 rule as published by the Environmental Appeals Board on November 12, 2024. The 2024 rule set the compliance deadline for processing and distributing decaBDE-containing wire and cable insulation until the end of the service life of these materials. Since decaBDE has long been relied upon as the flame retardant in one of the most common cross-linked polyethylene (XLPE) nuclear cable insulation formulations, RSCC Firewall III insulation, questions have naturally arisen regarding whether changes in cable performance might be expected for XLPE containing a decaBDE alternative, especially for safety-related cables that must perform their safety function in a design basis event such as a loss of coolant accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a Practical Secondary Control for Hardware Microgrids

Practical, vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that operates with all GFM IBRs and synchronous generators. This secondary control does not require the use of additional measurement devices in the MG and utilizes the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus registers, such as packet loss and quantization error, and their detrimental impacts on secondary control actions are investigated. The proposed three-stage modification for any secondary control architecture to mitigate these impacts includes: 1) averaging the data read, 2) situational event-triggering of the controller, and 3) finite iteration of the controlling action. The proposed method is validated using a 3-..phi.., 480 V, 60 Hz, 500 kVA laboratory hardware microgrid with commercial two GFM IBRs and one diesel generator. The experimental results corroborates the fact the proposed modification in the secondary control architecture is advantageous for practical usage under erroneous measurements.

communication systems↗

Noise Robustness and Experimental Demonstration of a Quantum Generative Adversarial Network for Continuous Distributions

Abstract The potential advantage of machine learning in quantum computers is a topic of intense discussion in the literature. Theoretical, numerical, and experimental explorations will most likely be required to understand its power. There have been different algorithms proposed to exploit the probabilistic nature of variational quantum circuits for generative modeling. In this paper, a hybrid architecture for quantum generative adversarial networks (QGANs) is employed and their robustness in the presence of noise is studied. A simple way of adding different types of noise to the quantum generator circuit is devised, and the noisy hybrid QGANs (HQGANs) are simulated numerically to learn continuous probability distributions, and to show that the performance of HQGANs remains unaffected. The effect of different parameters on the training time is also investigated to reduce the computational scaling of the algorithm and simplify its deployment on a quantum computer. The training on Rigetti's Aspen‐4‐2Q‐A quantum processing unit is then performed, and the results from the training are presented. The authors' results pave the way for experimental exploration of different quantum machine learning algorithms on noisy intermediate‐scale quantum devices.

Anand, Abhinav↗

Quantitative Small-Signal Stability Analysis of Grid-Forming Inverters in Large-Scale Power Systems

In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.

grid-following↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The interesting properties of natural gas as well as the growing electric power demand worldwide have led to increasing attention to natural-gas-based distributed generation applications in electric distribution systems. This paper goes over the interdependency between a residential natural gas network and an electric distribution network that are coupled via fuel cells. The modeling of the gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the gas and electric distribution networks, subject to their model constraints. In addition to this, in order to capture the probabilistic nature of the optimization problem under study, the K-means clustering algorithm is applied to the gas and electricity demands to determine hourly load states and their corresponding probabilities. Furthermore, simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution feeder and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Steady-State Thermal-Hydraulic Analysis and Bowing Reactivity Evaluation Methods Based on Neutron and Gamma Transport Calculations

With the advancement of computer technology, the variational nodal transport code VARIANT is now routinely used for sodium-cooled fast reactor (SFR) design analysis. In particular, VARIANT transport calculations are usually performed for whole core neutronics analyses and for fuel cycle analyses with REBUS-3. However, the steady-state thermal hydraulics analysis with the SE2-ANL coed and the assembly bowing reactivity calculation with the structural analysis with the NUBOW-3D code are still performed with the DIF3D finite difference diffusion theory code. Furthermore, the DIF3D diffusion calculation for these applications is performed with only six triangular meshes per hexagonal assembly, and the SE2-ANL code determines the pin power distributions approximately by assuming that the power distribution within an assembly is separable in the radial and axial directions. In order to overcome the limitations and to improve the accuracy of the existing methods, it was proposed to develop the relevant computational methods based on the transport calculations with the VARIANT and PROTEUS-SN codes. The objectives of this study are to develop a new heating calculation method based on the coupled neutron and gamma transport calculations with VARIANT, to implement the new heating calculation method into the SE2-ANL steady-state thermal-hydraulics analysis code with improved numerical algorithms and additional capabilities for automatic flow allocation calculations, and to develop a method to calculate bowing reactivity coefficients based on the VARIANT core solutions and the PROTEUS-SN assembly solutions, which can be used in NUBOW-3D calculations. A new, coupled neutron and gamma heating calculation procedure has been developed based on VARIANT transport calculations. In the new heating calculation procedure, the neutron flux distribution is first determined by solving an eigenvalue transport problem using the VARIANT transport code. Using the calculated neutron flux, the intra-nodal gamma source distributions are calculated to be consistent with the neutron flux distribution with the GAMSOR code. For this, the GAMSOR code has been updated to generate the intra-nodal gamma source distributions in the form of the VARSRC dataset of VARIANT. With this gamma source distribution, the gamma flux distribution is determined by solving a fixed source gamma transport problem using VARIANT again. With the neutron and gamma flux distributions, the heat generation rates are evaluated at individual fuel pins and assembly duct walls, without assuming separable axial and radial profiles for the intra-assembly power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Electric Power Outage Forecasting: Model

Electric distribution networks are the final leg of the network that moves electric power from generating stations to end users. The vast majority of the circuits in these networks are above ground, where they are exposed to direct damage from strong winds, broken tree limbs, toppled trees, and flying debris. These systems are also susceptible to winter storms. The combined stress of the weight of ice (icing), the increased wind resistance of the conductors, and broken tree limbs can damage lines, poles, and support structures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Power Outage Forecasting

Electrical distribution networks are the final leg of the network that moves electric power from generating stations to end users. The vast majority of the circuits in these networks are above-ground and exposed to direct damage from strong winds, broken tree limbs, toppled trees, and flying debris. These systems are also susceptible to ice storms. The combined stress of the weight of ice (icing), the increased wind resistance of the conductors, and broken tree limbs can damage lines, poles, and support structures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

battery↗

Guest Editorial: Special Issue on recent advancements in electric power system planning with high-penetration of renewable energy resources and dynamic loads

The goal of this Special Issue is to present the state-of-the-art methodologies developed for expansion planning of all segments of the modern power systems, characterized by separated businesses, high penetration of renewable resources and new load types, as well as by application of technologically advanced solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗