Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dogs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Engineering Polymer Blends for Impact Damage Mitigation

Structures containing polymers such as DuPont's Surlyn® 8940, demonstrate puncture healing when impacted by a 9 millimeter projectile traveling from speeds near 300 meters per second (1,100 feet per second) to hypervelocity impacts in the micrometeoroid velocity range of 5 kilometers per second (16,000 feet per second). Surlyn® 8940 puncture heals over a temperature range of minus 30 degrees Centigrade to plus 70 degrees Centigrade and shows potential for use in pressurized vessels subject to impact damage. However, such polymers are difficult to process and limited in applicability due to their low thermal stability, poor chemical resistance and overall poor mechanical properties. In this work, several puncture healing engineered melt formulations were developed. Moldings of melt blend formulations were impacted with a 5.56 millimeter projectile with a nominal velocity of 945 meters per second (3,100 feet per second) at about 25 degrees Centigrade, 50 degrees Centigrade and 100 degrees Centigrade, depending upon the specific blend being investigated. Self-healing tendencies were determined using surface vacuum pressure tests and tensile tests after penetration using tensile dog-bone specimens (ASTM D 638-10). For the characterization of tensile properties both pristine and impacted specimens were tested to obtain tensile modulus, yield stress and tensile strength, where possible. Experimental results demonstrate a range of new puncture healing blends which mitigate damage in the ballistic velocity regime.

Gordon, Keith L.↗

Experimental Observations of Damage States in Unnotched and Notched 3D Orthogonal Woven Coupons Loaded in Tension

This paper describes a series of unnotched and notched tensile tests on two 3D orthogonal woven architectures. Dog bone specimens were used for the unnotched tests, and open-hole specimens were used for the notched tests. For each architecture and test type, two specimens were loaded under monotonic displacement control to failure and two specimens were incrementally loaded to failure in five steps. X-ray computed tomography (CT) was used to characterize the woven architecture and defects on each specimen prior to testing. Digital image correlation (DIC) images were obtained from both sides of the specimen throughout the loading and unloading. Acoustic emission (AE) data were also continuously acquired throughout the loading. For the incremental tests, X-ray CT was used to document the damage progression after each load increment. The damage progression was analyzed based on the results from these three techniques. The results for both architectures and test specimens followed a pattern where matrix cracks formed at the surface perpendicular to the tensile load direction. New surface cracks formed continuously throughout the loading and cracks extended in depth and width. In general, fiber failure was not detected until specimen failure.

Wade C Jackson↗

Transfer Function Models and Sensitivity Analysis

In many situations, real or induced flaws such as tight cracks with known morphology cannot be manufactured in part configuration specimens or in real parts. Typically, fatigue cracks are manufactured in simple geometry specimens such as flat plates, dog-bone shaped flat or round specimens. If a nondestructive evaluation (NDE) technique is required to provide a reliably detectable target flaw size denoted as α_(90/95) for induced flaws in real part, then the direct method for qualifying the NDE procedure is to use the appropriate induced flaw specimens and perform probability of detection analysis using these flaws. This can be described as direct POD demonstration testing, which may follow guidelines of MIL-HDBK-1823. This paper considers a case, where induced flaws are not available in part configuration specimens. Therefore, a direct POD demonstration study cannot be undertaken. In such situation, general practice for NDE procedure qualification is to use artificial flaws in simple geometry and part configuration specimens, and induced flaws in the chosen simple geometry specimens. Signal response data is taken on all sets of artificial and induced flaws. NDE procedure testing on induced flaw in simple geometry specimen is called NDE demonstration testing here. A transfer function NDE procedure qualification method for forward case calculates predicted induced flaw size for demonstration using a chosen target flaw size. Another transfer function method for inverse case, calculates the target flaw size using a given demonstration flaw size. The transfer function analysis assumes relationship of artificial flaw signal responses in real parts and simple geometry specimens; and induced flaw responses in simple geometry specimens to induced flaws in real parts. The signal response transfer relationships model should be defined before transfer function models can be devised. Assuming that the signal response transfer relationships model is valid, forward and inverse case transfer function methods have been devised. Because of lack of signal response data from induced flaws in real part, 90/95% POD/confidence (P/C) cannot be demonstrated directly. However, the transfer function method may be assessed using simulation to evaluate whether the resulting target flaw size or demonstration flaw size provides adequate confidence to the assumed signal response transfer relationships model. Therefore, the transfer function approach is a risk assessment approach. Both the signal response transfer relationships model and the transfer function model are important in managing risk in results provided by the transfer function NDE technique qualification or assessment. The signal response transfer relationships model needs to be validated with empirical data and then transfer function model needs to be validated for desired P/C on case-by-case basis.

Nondestructive evaluation↗

Leveraging Automated Fiber Placement Computer Aided Process Planning Framework for Defect Validation and Dynamic Layup Strategies

Process planning represents an essential stage of the Automated Fiber Placement (AFP) workflow. It develops useful and efficient machine processes based upon the working material, composite design, and manufacturing resources. The current state of process planning requires a high degree of interaction from the process planner and could greatly benefit from increased automation. Therefore, a list of key steps and functions are created to identify the more difficult and time-consuming phases of process planning. Additionally, a set of metrics must exist by which to evaluate the effectiveness of the manufactured laminate from the machine code created during the Process Planning stage. Layup strategies, in addition to dog ears, stagger shifts, steering constraints, and starting points, represented the group of functions labeled as process optimization and ranked the highest in terms of priority for automation. The laminates resulting from the selected parameters are evaluated through the occurrences of principal defect metrics such as fiber gaps, overlaps, angle deviation and steering violations. This document presents an automated software solution to the layup strategy and starting point selection phase of process planning. A series of ply scenarios are generated with variations of these ply parameters and evaluated according to a set of metrics entered by the Process Planner. These metrics are generated through use of the Analytical Hierarchy Process (AHP), where relative importance between each of the fiber features are defined. The ply scenarios are selected which reduce the overall fiber feature scores based on the defects the Process Planner wishes to minimize.

HiCAM↗

Transfer function models for using empirical and physics-based simulation signal response data

In many situations, real or induced flaws such as tight cracks with known morphology cannot be manufactured in part geometry specimens or in real parts. Typically, surface fatigue cracks are manufactured in simple geometry specimens such as flat plates, dog-bone shaped flat or cylindrical specimens. If a nondestructive evaluation (NDE)technique is required to provide a reliably detectable flaw size, denoted asa90/95, for induced flaws in a part, then a direct method for qualifying the NDE procedure is to use appropriate induced flaw specimens and perform NDE procedure demonstration on the specimens. Probability of detection (POD)analysis of the empirical data may provide estimation of a90/95. This approach is described as direct POD demonstration testing, which may follow guidelines of MIL-HDBK-1823. This paper considers a case, where embedded tight cracklike induced flaws are to be detected reliably using a signal response based NDE procedure. Here, it is assumed that it is not practical to make surface or embedded induced flaw specimens in part geometry or configuration. Therefore, a direct POD demonstration testing cannot be undertaken. It is also assumed that simulation of signal response is possible for both surface and embedded induced flaws in part geometry specimens using a physics-based model. The proposed approach for NDE procedure qualification uses artificial flaws in simple geometry and part geometry specimens, and induced flaws in the same type of simple geometry specimens. Signal response data is taken on all sets of artificial and induced flaws in simple geometry and part geometry specimens. Moreover, simulated signal response data is generated for surface and embedded flaws. Thus, a case of five signal response versus flaw size datasets is considered. Three of the datasets are empirical and two datasets are physics model-based simulation datasets. A method of devising and using transfer function calculation dataset blocks to estimate the either the reliably detectable flaw size or the demonstration flaw size is provided.

Nondestructive evaluation↗

Multiple piece turbine airfoil

A turbine airfoil, such as a rotor blade or a stator vane, for a gas turbine engine, the airfoil formed as a shell and spar construction with a plurality of dog bone struts each mounted within openings formed within the shell and spar to allow for relative motion between the spar and shell in the airfoil chordwise direction while also forming a seal between adjacent cooling channels. The struts provide the seal as well as prevent bulging of the shell from the spar due to the cooling air pressure.

Kimmel, Keith D↗

Optimization for Single-Spike X-Ray FELs at LCLS with a Low Charge Beam

The Linac Coherent Light Source is an x-ray free-electron laser at the SLAC National Accelerator Laboratory, which is operating at x-ray wavelengths of 20-1.2 Angstrom with peak brightness nearly ten orders of magnitude beyond conventional synchrotron radiation sources. At the low charge operation mode (20 pC), the x-ray pulse length can be <10 fs. In this paper we report our numerical optimization and simulations to produce even shorter x-ray pulses by optimizing the machine and undulator setup at 20 pC charge. In the soft x-ray regime, with combination of slotted-foil or undulator taper, a single spike x-ray pulse is achievable with peak FEL power of a few 10s GW. Linac Coherent Light Source (LCLS), the world's first hard x-ray Free electron laser (FEL), has started operation since 2009. With nominal operation charge of 250 pC, the generated x-ray pulse length is from 70 fs to a few hundred fs. This marks the beginning of a new era of ultrashort x-ray sciences. In addition, a low charge (20pC) operation mode has also been established. Since the collective effects are reduced at the low charge mode, we can increase the compression factor and still achieve a few kA peak current. The expected electron beam and x-ray pulses are less than 10 fs. There are growing interests in even shorter x-ray pulses, such as fs to sub-fs regime. One of the simple solutions is going to even lower charge. As discussed, single-spike x-ray pulses can be generated using 1 pC charge. However, this charge level is out of the present LCLS diagnostic range. 20 pC is a reasonable operation charge at LCLS, based on the present diagnostic system. At 20 pC in the soft x-ray wavelength regime, we have experimentally demonstrated that FEL can work at undercompression or over-compression mode, such as 1 degree off the full-compression; at full-compression, however, there is almost no lasing. In hard x-ray wavelength regime, we observed that there are reasonable photons generated even at full-compression mode, although the photon number is less than that from under-compression or over-compression mode. Since we cannot measure the x-ray pulse length at this time scale, the machine is typically optimized for generating maximum photons, not minimum pulse length. In this paper, we study the methods of producing femtosecond (or single-spike) x-ray pulses at LCLS with 20 pC charge, based on start-to-end simulations. Figure 1 shows a layout of LCLS. The compression in the second bunch compressor (BC2) determines the final e-beam bunch length. However, the laser heater, dog-leg after the main linac (DL2) and collective effects also affect the final bunch length. To adjust BC2 compression, we can either change the L2 phase or BC2 R{sub 56}. In this paper we only tune L2 phase while keep BC2 R{sub 56} fixed. For the start-to-end simulations, we used IMPACT-T and ELEGANT tracking from the photocathode to the entrance of the undulator, after that the FEL radiation was simulated with GENESIS. IMPACT-T tracks about 10{sup 6} particles in the injector part until 135 MeV, including 3D space charge force. The output particles from IMPACT-T are smoothed and increased to 12 x 10{sup 6} to reduce high-frequency numerical noise for subsequent ELEGANT simulations, which include linear and nonlinear transport effects, a 1D transient model of CSR, and longitudinal space charge effects, as well as geometric and resistive wake fields in the accelerator. In GENESIS part, the longitudinal wake field from undulator chamber and longitudinal space field are also included.

43 PARTICLE ACCELERATORS↗

Generation and Analysis of Subpicosecond Double Electron Bunch at the Brookhaven Accelerator Test Facility

Two compressed electron beam bunches from a single 60-MeV bunch have been generated in a reproducible manner during compression in the magnetic chicane - 'dog leg' arrangement at ATF. Measurements indicate they have comparable bunch lengths ({approx}100-200 fs) and are separated in energy by {approx}1.8 MeV with the higher-energy bunch preceding the lower-energy bunch by 0.5-1 ps. Some simulation results for analyzing the double-bunch formation process are also presented.

43 PARTICLE ACCELERATORS↗

TENSILE SPECIMEN DESIGN AND EXPERIMENTAL PROCEDURES FOR CHARACTERIZING POLYMERIC COMPOSITES USING X-RAY BASED MICRO-TOMOGRAPHY

The recent rapid increase in the use of continuous and chopped fiber composites for automotive, aerospace, and naval applications demands an increased understanding of microstructure evolution with stress in order to understand potential failure locations. X-ray imaging with micro-focus source and optics with high resolution shows promise for exploring such technology to study the microstructure. Initial tomography and radiography results will be presented that clearly show individual fibers and its interface with the resin as a function of tensile stress. In this study, we focus on the design of miniature fiber reinforced polymer specimens suitable for examination during tensile loading using a micro-tomography system. Issues related to potential stress concentrations and experimental boundary conditions are examined using finite element analysis. Two gripping designs and specimen geometries are examined analytically and experimentally. Specimens with cylindrical cross-section with specimen ends bonded to a metallic threaded grip were considered for thermoset materials. Grips containing cavities with cylindrical and conical shapes were also examined. Dog-bone shaped, shoulder loaded, square cross-section sample was considered for thermoplastic materials because of difficulties bonding them to a metallic threaded grip.

Failure Mechanisms↗

CHARACTERIZATION OF GLOVEBOX GLOVES FOR THE SAVANNAH RIVER SITE

A task was undertaken to characterize glovebox gloves that are currently used in the facilities at Savannah River Site (SRS) as well as some experimental and advanced compound gloves that have been proposed for use. Gloves from four manufacturers were tested for permeation in hydrogen and air, thermal stability, tensile properties, puncture resistance and dynamic mechanical response. The gloves were compared to each other within the type and also to the butyl rubber glove that is widely used at the SRS. The permeation testing demonstrated that the butyl compounds from three of the vendors behaved similarly and exhibited hydrogen permeabilities of .52‐.84 x10{sup ‐7} cc H{sub 2}*cm / (cm{sup 2}*atm). The Viton glove performed at the lower edge of this bound, while the more advanced composite gloves exhibited permeabilities greater than a factor of two compared to butyl. Thermogravimetric analysis was used to determine the amount of material lost under slightly aggressive conditions. Glove losses are important since they can affect the life of glovebox stripper systems. During testing at 90, 120, and 150°C, the samples lost most of the mass in the initial 60 minutes of thermal exposure and as expected increasing the temperature increased the mass loss and shortened the time to achieve a steady state loss. The ranking from worst to best was Jung butyl‐Hypalon with 12.9 %, Piercan Hypalon with 11.4 %, and Jung butyl‐Viton with 5.2% mass loss all at approximately 140°C. The smallest mass losses were experienced by the Jung Viton and the Piercan polyurethane. Tensile properties were measured using a standard dog bone style test. The butyl rubber exhibited tensile strengths of 11‐15 MPa and elongations or 660‐843%. Gloves made from other compounds exhibited lower tensile strengths (5 MPa Viton) to much higher tensile strengths (49 MPa Urethane) with a comparable range of elongation. The puncture resistance of the gloves was measured in agreement with an ASTM standard. The Butyl gloves exhibited puncture resistance from 183 - 296 lbs/in for samples of 0.020 - 0.038 thick. Finally, the glass transition temperature and the elastic and viscoelastic properties as a function of temperature up to maximum use temperature were determined for each glove material using Dynamic Mechanical Analysis. The glass transition temperatures of the gloves were ‐60°C for butyl, ‐30°C for polyurethane, ‐ 16°C Hypalon, ‐16°C for Viton, and ‐24°C for polyurethane‐Hypalon. The glass transition was too complex for the butyl‐Hypalon and butyl‐Viton composite gloves to be characterized by a single glass transition temperature. All of the glass transition temperatures exceed the vendor projected use temperatures.

42 ENGINEERING↗

FL V1.3

A library of utility classes for computer vision. Contains implementations of various well-known image processing techniques, such as interest point operators and region descriptors. Includes interfaces to various libraries for image and video I/O, as well as an interface to LAPACK/BLAS. FL was developed at the University of Illinois, Urbana-Champaign (UIUC) and released under an open source license. Version 1.2 was a maintenance release provided by SNL under the LGPL license. Version 1.3 is a maintenance release, containing the following changes: - Improved image format handling. Now handles strided and planar memory layouts and a wider range of pixel formats. - Improved image file I/O, including better support for metadata, a wider range of stored pixel types, and a couple of new file formats. - Improvements to DOG and SIFT, and efficiency improvements in low-level convolution. - Improvements to networking, including a generic TCP listener. - Various improvements to numerical processing. The HISTORY file included in the distribution contains a more detailed description of the changes.

Rothganger, Frederick↗

The Escaramujo Project: Instrumentation Courses During a Road Trip Across the Americas

The Escaramujo Project was a series of eight hands-on laboratory courses on High Energy Physics and Astroparticle Instrumentation, in Latinamerican Institutions. The Physicist Federico Izraelevitch traveled on a van with his wife and dogs from Chicago to Buenos Aires teaching the courses. The sessions took place at Institutions in Mexico, Guatemala, Costa Rica, Colombia, Ecuador, Peru and Bolivia at an advanced undergraduate and graduate level. During these workshops, each group built a modern cosmic ray detector based on plastic scintillator and silicon photomultipliers, designed specifically for this project. After the courses, a functional detector remained at each institution to be used by the faculty to facilitate the training of future students and to support and enable local research activities. The five-days workshops covered topics such as elementary particle and cosmic ray Physics, radiation detection and instrumentation, low-level light sensing with solid state devices, front-end analog electronics and object-oriented data analysis (C++ and ROOT). Throughout this initiative, about a hundred of talented and highly motivated young students were reached. With the detector as a common thread, they were able to understand the designing principles and the underlying Physics involved in it, build the device, start it up, characterize it, take data and analyze it, mimicking the stages of a real elementary particle Physics experiment. Besides the aims to awaken vocations in science, technology and engineering, The Escaramujo Project was an effort to strengthen the integration of Latinamerican academic institutions into the international scientific community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

FINITE ELEMENT MODEL MESH REFINEMENT EFFECTS ON QUALIFICATION OF NUCLEAR GRADE GRAPHITE COMPONENTS

The American Society of Mechanical Engineers (ASME) provides the full and simplified design-by-analysis probabilistic assessments for determining acceptance of nuclear grade graphite core components. The assessments can be characterized by three parts: (1) a component stress distribution, often determined by a finite element (FE) model; (2) a Weibull probability density function (pdf) that characterizes the experimental tensile strength distribution; and (3) the post-processor, which combines the FE model and the Weibull strength distribution in accordance with the full and simplified assessments to determine component acceptance. It is known that the level of mesh refinement in FE models can affect the modeled component’s calculated stress distribution. Depending on the component geometry, the stress distribution may converge with sufficient refinement. It was previously unknown whether the acceptance decision resulting from the full and simplified assessments might change even with sufficient mesh refinement. This study explores that question using experimental strength results for a dog-bone geometry for two graphite grades, IG-110 and PCEA. The simplified assessment has two criteria that must be met, the first limits the combined membrane stress by the allowable stress and the second limits the peak equivalent stress by the allowable stress scaled by the ratio of flexural to tensile strength. In the application of the simplified assessment, convergence of the peak equivalent stress required extreme mesh refinement, however, the acceptance decision was not affected. It is hypothesized that more complex geometries with stress concentrations may present mesh refinement effects on the simplified assessment acceptance decision. Mesh refinement did affect the acceptance decision in the full assessment for the applied pressure loadings in this study. This work suggests component stress distribution convergence is not a sufficient criteria for POF convergence in the full assessment and that mesh refinement should continue until the POF has converged, especially where the resulting POF is bordering the SRC acceptable POF limit.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Loading Capabilities of Irradiated 3-D Printed Polymers

Gamma radiation is the emission of a high-energy photon from a radioactive source. The photon then interacts with an atom potentially damaging it. While time has shown that gamma radiation has a little effect on metals, the same cannot be said about plastic. The use of these types of materials in radioactive areas has increased for many reasons ranging from the weight difference between plastics and metals to the costs associated with doing so. For example, a potential use for radiation resistant plastics could be longer lasting, cost effective, and light weight radiation detection devices sent to probe an area that may present unsafe conditions for humans to survey. For these reasons and more, finding a plastic polymer that can withstand radiation for an extended period of time would make a great impact on the nuclear industry. In this experiment, two different polymers will undergo a series of strength tests before and after being exposed to radiation after different amounts of time up to two weeks. There are two sets of plastic polymers that will be used. Each set will consist of an nonirradiated, control subset, and subsets subject to radiation for one day, one week, and two weeks. The radiation source is 1100 Ci cobalt- 60. The specimens are placed on a foam platform such that they will be exposed as evenly as possible. They are then lowered into the radiation chamber where they are surround by cobalt-60 sources and irradiated for the given amount of time. The specimens will be tested for tensile strength and flexural strength according to ASTM standards. For tensile testing, the specimen has a 'dog bone' shape. The specimen is gripped at the wide ends, and pulled away from the center at a constant rate until failure. To test flexural strength, the specimens will be subject to a 3-point bend test. The specimen is held in place by three points, center top side and both ends bottom side. Load is applied at a constant rate on the center of the specimen until failure. The calculations to be considered for comparison after performing these tests include the tensile strength and stress, elongation, flexural stress and strain, and elasticity. Once these tests are completed, testing specimens that have been 3D printed with different print orientations will be considered and tested. The results from both experiments will help create strong, radiation resistant products in a expeditious manner that could really push the current limitations and expand the use of radiation resistant material.

36 MATERIALS SCIENCE↗

Intern Poster

Digital Image Correlation (DIC) is an optical technique that combines image registration and tracking methods for accurate two-dimensional and three-dimensional changes in images. DIC software can be used to track the contour, deformation, and strain of a sample. In the Advanced Test Reactor (ATR) at INL (Idaho National Laboratory) there exists a small working window of samples that can become irradiated. Hundreds of graphite disks called piggybacks have undergone this irradiation as part of the Advanced Reactor Technologies (ART) program. After irradiation, it is desirable to understand the change in tensile strength as a function of dose. Due to the limited space in the ATR, typical dog bone tensile tests reduce the number of graphite samples from hundreds to tens. However, there does exist an ASTM standard, D8289, which uses disc compression of graphite to estimate the tensile strength of the specimen with the Brazilian Disk test fixture. While only used as an estimate, which is typically off by a third, it is the purpose of this study to identify how to amend D8289 to remove the word "estimate" with the help of DIC.

36 MATERIALS SCIENCE↗

2025 Intern Poster - Abbigail Short

The OSCC Coupling Shaft Handling Fixture, known as the "Puppy Dog Tool," was originally designed by hand in 1976. The initial design was difficult to read and replicate, lacking 3D modeling for simulations and testing. To modernize the tool, the original drawings were reviewed and recreated in Autodesk Inventor with increased spacing for clarity. Key improvements included adding a hook, modifying the top plate and main body connection, and introducing a guiding wall for the clamp. These changes enhanced durability and usability, preventing bending and facilitating easier assembly. The updated design preserved the tool's functionality while making it more robust and user-friendly for high-precision operations.

99 - GENERAL AND MISCELLANEOUS↗

Impact Testing of Stainless Steel Material at Cold Temperatures

Stainless steels are used for the construction of numerous spent nuclear fuel or radioactive material containers that may be subjected to high strains and moderate strain rates during accidental drop events. Mechanical characteristics of these base materials and their welds under dynamic loads in the strain rate range of concern are not well documented. However, a previous paper [1] reported on impact testing and analysis results performed at the Idaho National Laboratory using 304/304L and 316/316L stainless steel base material specimens at room and elevated temperatures. The goal of the work presented herein is to add recently completed impact tensile testing results at -20 degrees F conditions for dual-marked 304/304L and 316/316L stainless steel material specimens (hereafter referred to as 304L and 316L, respectively). Recently completed welded material impact testing at -20 degrees F, room, 300 degrees F, and 600 degrees F is also reported. Utilizing a drop-weight impact test machine and 1/4-inch to 1/2-inch thick dog-bone shaped test specimens, the impact tests achieved strain rates in the 4 to 40 per second range, depending upon the material temperature. Elevated true stress-strain curves for these materials reflecting varying strain rates and temperatures are presented herein.

42 ENGINEERING↗