CdZnTe Detector Using for Characterization MR Water Cleanup System before Dismantling - 17005
The Kurchatov Institute's MR research reactor water cleanup system comprises 20 containers with ion-exchange resin. Each container is 25 cm in diameter and 130 cm high. These containers are placed under the floor with 50 cm concrete protection. Access to container is provided via technological hole with protective covers. A CdZnTe detector was chosen for spectrometric investigation due to high exposure dose level from containers. A collimated spectrometric system on the basis of a semiconductor detector CdZnTe (volume of a crystal of 20 mm{sup 3} or 60 mm{sup 3}) and a multichannel analyzer InSpector 2000 was developed. It was determined that 8 of the 20 containers were filled with the ion- exchange resin in aqueous solution. The main dose forming radionuclide was {sup 137}Cs. Specific activity was from 10{sup 7} Bq/kg to 10{sup 9} Bq/kg in different containers. Measurements were carried out in high radiation fields and the background radiation reached the detector even through the lead shield, which created difficulties in the interpretation of collected data. For verification of the results some samples of ion-exchange resin was taken from containers. The concentration of γ-ray radionuclides was estimated by the Canberra Company spectrometric complex that included a semi-conductor detector made of HP Germanium. Obtained data had good correlation with the data of the CdZnTe collimated spectrometer. Our investigation has shown that remote mechanisms must be used to remove the containers with ion-exchange resin. (authors)