At least 685 records · Page 38

Research plan for the development of optical fiber pressure sensors for nuclear applications

Fiber optic pressure sensors are desirable for nuclear applications because they are low mass/small size, immune to electromagnetic interference, high sensitivity, and have multiplexing and multimodal measurement capabilities. Much research and development has been conducted on developing fiber optic based sensors and they are now considered a class of standard instrumentation in many industries. Specifically, for pressure sensing, a wide range of fiber based sensors have been developed for various pressure ranges and environments. This vast body of research will be leveraged for the development of pressure sensors for nuclear applications. Four pressure measurement scenarios were considered which would benefit from a fiber optic based pressure sensor. These scenarios include pressure measurement in the fuel rod plenum, coolant pressure during LOCA testing, advanced coolant (helium, sodium, molten salt) pressure for flow loop operation, and high pressures resulting for direct fuel-coolant interaction. Each scenario has unique pressure, temperature, and material requirements for the sensor. From a survey of commercially available sensors and a literature review; it has been determined that an extrinsic Fabry-Perot interferometer approach is the most appropriate for the various measurement requirements. The experience and knowledge base for Fabry-Perot interferometers can be leveraged since they are the most common fiber optic based pressure sensors available commercially and found in literature. These pressure sensors rely on the interference of light in a gas filled cavity, which minimizes the impact of radiation induced attenuation and compaction on the measurement, compared to intrinsic sensing techniques. The measurement range of these sensors is based on the stiffness of the diaphragm that deflects under pressure. This allows for a suite of fiber based sensors to be developed by interchanging this diaphragm for the requirements of each application. Key material and design considerations have been identified for the development of a Fabry-Perot interferometry pressure measurement for nuclear applications. These include high temperature bonding between the glass fiber optic and metal housing, identifying diaphragm materials & geometry, and minimizing cross sensitivity to temperature or implementing compensation techniques found in literature. Overcoming these challenges will develop a pathway for a fiber optic based pressure sensor for nuclear applications, and additionally can be leveraged for other sensing application based on Fabry-Perot interferometers, such as temperature, strain (creep & deformation), vibration, and index of refraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent results from MAMI

The Mainz Microtron MAMI is an ideal facility to study the hadron structure with the electromagnetic probe. With the new accelerator stage (HDSM), which went into operation in 2007, high-intensity polarized electron and photon beams with energies up to 1.6 GeV are delivered to the experiments. Polarized targets and recoil polarimeters in combination with dedicated detectors are available for precision experiments in hadron physics. In this article, an overview over selected recent results is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multichannel time-of-flight system for observation of energetic ions of multispecies generated from relativistic laser plasma

A multichannel time-of-flight (TOF) system was constructed to observe the ions generated from relativistic laser plasma, where the ions have polychromatic energies and multiple species. The TOF system is composed of a ten-channel scintillation detector array and an electromagnet that generates a magnetic field of 0-1.24 T. The magnet field enables us to analyze protons, deuterons, and full-stripped carbon ions to 50, 25, and 150 MeV, respectively. The system experimentally identified protons of 0.27-1.6 MeV energy and ions of a half specific charge (deuterons of 0.3-0.8 MeV and full-stripped carbons of 1.8-4.8 MeV). The measured TOF values agree well with the calculated values within the designed accuracy; {+-}2.5 ns for protons and {+-}5 ns for the others (d or C{sup 6+}) on each detector channel. Comparison of ion numbers detected by a track detector (CR-39) and the TOF system enabled us to obtain the number of ions detected on each scintillation counter with less than 16% error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave hydrothermal synthesis and photocatalytic activity of AgIn{sub 5}S{sub 8} for the degradation of dye

AgIn{sub 5}S{sub 8} powders were successfully synthesized by a microwave hydrothermal method for the first time. This method is a mild and highly efficient route involves no templates, catalysts, or surfactants. Therefore, it is very promising for the low-cost and large-scale industrial production. The samples were characterized by X-ray diffraction, UV-vis spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy. The photocatalytic activity of AgIn{sub 5}S{sub 8} nanoparticles was investigated through the degradation of methyl orange under visible light irradiation. Compared with TiO{sub 2-x}N{sub x}, AgIn{sub 5}S{sub 8} has exhibited a superior activity under the same condition. A liquid chromatogram-mass spectrometer was used to separate and identify the dye and degradation products generated during the reaction. According to the experiment results, a possible mechanism for the degradation of organic pollutant over AgIn{sub 5}S{sub 8} was proposed. - Graphical abstract: Compared with TiO{sub 2-x}N{sub x}, AgIn{sub 5}S{sub 8} has exhibited a superior activity under the same condition.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cherenkov-type diamond detectors for measurements of fast electrons in the TORE-SUPRA tokamak

The paper presents a schematic design and tests of a system applicable for measurements of fast electron pulses emitted from high-temperature plasma generated inside magnetic confinement fusion machines, and particularly in the TORE-SUPRA facility. The diagnostic system based on the registration of the Cherenkov radiation induced by fast electrons within selected solid radiators is considered, and electron low-energy thresholds for different radiators are given. There are some estimates of high thermal loads, which might be deposited by intense electron beams upon parts of the diagnostic equipment within the TORE-SUPRA device. There are some proposed measures to overcome this difficulty by the selection of appropriate absorption filters and Cherenkov radiators, and particularly by the application of a fast-moving reciprocating probe. The paper describes the measuring system, its tests, as well as some results of the preliminary measurements of fast electrons within TORE-SUPRA facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques for Handling and Removal of Spectral Channels in Fourier Transform Synchrotron-Based Spectra

Channel spectra are a big problem for those attempting to use synchrotron-based Fourier transform spectra for spectral lineshape studies. Due to the layout of the optical system at the CLS far-infrared beamline, the synchrotron beam undergoes unavoidable multiple reflections on the steering mirrors, beam splitter, several sets of windows, and filters. We present a method for eliminating channel spectra and compare the results of our technique with other methods available in the literature.

43 PARTICLE ACCELERATORS↗

Ion imaging in a high-gradient magnetic guide

We study a photoionization method to detect and image a narrow beam of cold atoms traveling along a high-gradient two-wire magnetic guide that is continuously on. Ions are accelerated in a compact acceleration region, directed through a drift region several centimeters in length, and detected using a position-sensitive ion detector. The potentials of several electrodes can be varied to adjust the imaging properties. Using ion trajectory simulations as well as experiments, we study the passage of the ions through the detection system, the magnification of the detection system, and the time-of-flight characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Heat Load Diamond Monochromator Project at ESRF

Due to its outstanding thermal properties, diamond is an attractive alternative to silicon as a monochromator material for high intensity X-ray beams. To date, however, the practical applications have been limited by the small size and relatively poor crystallographic quality of the crystals available. The ESRF Diamond Project Group has studied the perfection of diamonds in collaboration with industry and universities. The group has also designed and tested different stress-free mounting techniques to integrate small diamonds into larger X-ray optical elements. We now propose to develop a water-cooled Bragg-Bragg double crystal monochromator using diamond (111) crystals. It will be installed on the ESRF undulator beamline, ID06, for testing under high heat load. This monochromator will be best suited for the low energy range, typically from {approx}3.4 keV to 15 keV, due to the small size of the diamonds available and the size of the beam footprint. This paper presents stress-free mounting techniques studied using X-ray diffraction imaging, and their thermal-mechanical analysis by finite element modelling, as well as the status of the ID06 monochromator project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron Area X-ray Detectors, Present and Future

X-ray experiments are very frequently detector limited at today's storage ring synchrotron radiation (SR) sources, and will be even more so at future Energy Recovery Linac and X-ray Free Electron Laser sources. Image plate and phosphor-coupled CCD detectors that predominate at present-day sources were outgrowths of technologies initially developed for the medical and astronomical communities, respectively, with resultant limitations for SR. These limitations are enumerated. The growth of commercial silicon foundries and design tools enabling the production of large, customized integrated circuits is beginning to have a profound impact on SR detectors and is ushering in the age of 'designer detectors'. Novel area Pixel Array Detectors (PADs) are starting to appear in which each pixel has dedicated, complex circuitry capable of high speed and, in some cases, significant data processing power for specific applications. PADs now at, or near the horizon will be described. Integrated circuit methods continue to develop at a rapid pace. Implications for future x-ray detectors will be discussed.

43 PARTICLE ACCELERATORS↗

Constraining compactness and magnetic field geometry of X-ray pulsars using pulse profile statistics

We use the statistics of 131 X-ray pulsar light curves in order to constrain the neutron star compactness and the inclination of the magnetic dipole. The X-ray pulse profiles are classified according to the number of pulses seen during one period, dividing them into two classes, single- and double-peaked. The relative fraction of pulsars in these classes is compared with the probabilities predicted by a theoretical model for different types of pencil-beam patterns. Our results show that a statistic of pulse profiles does not constrain compactness of the neutron stars. In contrast to the previous claim, the data do not require the magnetic inclination to be confined in a narrow interval but instead the magnetic dipole can have arbitrary inclinations to the rotational axis. The observed fractions of different types of light curves can be explained by taking into account the X-ray detector sensitivity (i.e. detection threshold for weak pulses), which decreases the fraction of the observed double-peaked light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exclusive Photoproduction of K + Σ* - (n) Off Deuteron

We are using the CEBAF Large Acceptance Spectrometer (CLAS) to study the exclusive photoproduction of K + Σ* - (1385) off the deuteron. It will be the first published total cross section of this reaction channel. We show the preliminary results of the total cross section, while we present all the key steps of achieving it. In order to study the reaction mechanism, we also study and show the angular distribution in the Gottfried-Jackson frame.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the Polarization Observables I{sup s} and I{sup c} for {gamma}{sup {yields}p{yields}}p{pi}{sup +{pi}-} using the CLAS Spectrometer

Model predictions regarding the excited baryon spectrum provided by Constituent Quark Models show good agreement with experimental measurements in the low-energy region less than {approx_equal}1.8 GeV. The mass region above {approx_equal}1.8 GeV, however, contains many resonances which are predicted to exist by these models but have not been experimentally verified. The analysis of a double meson final state using linearly polarized photoproduction data allows access to two polarization observables, I{sup s} and I{sup c}(also known as the beam asymmetry {Sigma} for a single meson final state). It has been shown that measurements of these polarizaton observables can provide insight into this missing resonance problem. This analysis was carried out on data taken from the CLAS-g8b data run period conducted at Jefferson Lab in Newport News, Virginia. The analysis of this data and preliminary measurements of these obsevables will be dicussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Helicity Difference in γ → p → →pπ + π - with the CLAS Spectrometer at Jefferson Laboratory

The study of the properties of baryon resonances can provide us with hints to help us understand the structure of non-perturbative QCD and the effect of a particular resonance on polarization observables. The investigation of double-pion photoproduction data is needed to discover higher-lying states and their properties at and above W [approximate] 1.8 GeV. Therefore, the analysis of the helicity difference in gp γp→pπ + π - will help us in our understanding of QCD.The CLAS g9a (FROST) experiment, as part of the N* spectroscopy program at Jefferson Laboratory, has accumulated photoproduction data using linearly and circularly polarized photons incident on a longitudinally-polarized butanol target in the photon energy range 0.3 to 2.4 GeV. The FROST experiment provides an important step toward a “complete” experiment for the reaction gammaN-->KY.In this contribution, the method to calculate the helicity difference for the reaction γp→pπ + π - will be described and preliminary results will be discussed.

43 PARTICLE ACCELERATORS↗

The Axion Dark-Matter eXperiment (ADMX): Recent Results

The axion is a hypothetical elementary particle whose existence would explain the baffling absence of CP violation in the strong interactions. It's properties in addition make it a good dark-matter candidate. Even though dark-matter axions would make up the overwhelming majority of mass in the universe, they are extraordinarily difficult to detect. We have developed a detector, ADMX, for dark-matter axions that is at heart an exquisitely sensitive detector of electromagnetic radiation. This talk will describe the progress we have made in this experimental search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Current sheath behavior and its velocity enhancement in a low energy Mather-type plasma focus device

The dynamics of the plasma sheath layer and its velocity enhancement have been studied in a low energy (4.9 kJ) Mather-type plasma focus device. Experiments were performed to study the effect of the Lorentz force variation on the current sheath expansion and movement, as well as the existence of traction between all parts of the sheath layer. Two different shape of anodes (cylindrical and step) along with an axial magnetic probe were used to investigate the effects of various experimental conditions, namely different charging voltages and gas pressures. In order to explore the upper limit of the current sheath velocity, a comparison has been made between the experimental data gathered by the probe and the Lee's computational model. The limitations governing the enhancement of the current sheath velocity that can lead to the deterioration of a good focusing phenomenon were also investigated. The increase of the current sheath velocity due to the usage of the step anode on ion generation and hard x-ray emissions have been demonstrated by means of an ion collector and a hard x-ray detector.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modified magnetic field distribution in relativistic magnetron with diffraction output for compact operation

A modified magnetic field distribution in relativistic magnetron with diffraction output (MDO) for compact operation is proposed in this paper. The principle of how the modified magnetic field confines electrons drifting out of the interaction space is analyzed. The results of the particle-in-cell (PIC) simulations of the MDO with the modified magnetic field distribution show that the output power of the MDO is improved, and the long cylindrical waveguide used for collecting the drifting electrons can be omitted. The latter measure allows the horn antenna of the MDO to produce more focused energy with better directivity in the far field than it does with the long cylindrical waveguide. The MDO with the modified magnetic field distribution promises to be the real most compact narrow band high power microwave source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Following Dynamic Processes by X-ray Tomographic Microscopy with Sub-second Temporal Resolution

Several non-destructive imaging techniques offer the possibility to observe rapid phenomena in real time, yet most of these techniques fail when it comes to bulky samples and micrometer precision in three dimensions. Therefore there is clearly a need to develop approaches that address such conditions. We identified the large potential that lies in synchrotron-based x-rays as a probe and developed a direct-space tomographic instrument suitable to provide sub-second temporal resolution with several-micrometers spatial resolution. Selected applications from the field of biology and material science are shown in order to demonstrate the unique capabilities in generating three-dimensional images with very high quality making image segmentation and analysis possible for samples that could, until now, only be studied in two dimensions due to the occurrence of rapid structural changes.