Search NASA⌕ Search

SEARCH · Search NASA

Results for “Effectiveness factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Effect of stromal-cell-derived factor 1 on stem-cell homing and tissue regeneration in ischaemic cardiomyopathy

BACKGROUND: Myocardial regeneration via stem-cell mobilisation at the time of myocardial infarction is known to occur, although the mechanism for stem-cell homing to infarcted tissue subsequently and whether this approach can be used for treatment of ischaemic cardiomyopathy are unknown. We investigated these issues in a Lewis rat model (ligation of the left anterior descending artery) of ischaemic cardiomyopathy. METHODS: We studied the effects of stem-cell mobilisation by use of granulocyte colony-stimulating factor (filgrastim) with or without transplantation of syngeneic cells. Shortening fraction and myocardial strain by tissue doppler imaging were quantified by echocardiography. FINDINGS: Stem-cell mobilisation with filgrastim alone did not lead to engraftment of bone-marrow-derived cells. Stromal-cell-derived factor 1 (SDF-1), required for stem-cell homing to bone marrow, was upregulated immediately after myocardial infarction and downregulated within 7 days. 8 weeks after myocardial infarction, transplantation into the peri-infarct zone of syngeneic cardiac fibroblasts stably transfected to express SDF-1 induced homing of CD117-positive stem cells to injured myocardium after filgrastim administration (control vs SDF-1-expressing cardiac fibroblasts mean 7.2 [SD 3.4] vs 33.2 [6.0] cells/mm2, n=4 per group, p<0.02) resulting in greater left-ventricular mass (1.24 [0.29] vs 1.57 [0.27] g) and better cardiac function (shortening fraction 9.2 [4.9] vs 17.2 [4.2]%, n=8 per group, p<0.05). INTERPRETATION: These findings show that SDF-1 is sufficient to induce therapeutic stem-cell homing to injured myocardium and suggest a strategy for directed stem-cell engraftment into injured tissues. Our findings also indicate that therapeutic strategies focused on stem-cell mobilisation for regeneration of myocardial tissue must be initiated within days of myocardial infarction unless signalling for stem-cell homing is re-established.

NASA Discipline Cardiopulmonary↗

Permeability and Induced Polarization of Mudstones

Electrical measurements can be used to estimate hydraulic properties such as permeability ( k ) in sedimentary rocks. Previous work has focused on sandstones, siltstones, and carbonates, while investigations on mudstones have rarely been reported. In this study, we report on electrical geophysical measurements for 23 mudstone samples using an experimental approach designed to reliably saturate these low permeability mudstones. The modified Hagen-Poiseuille model linking permeability to the formation factor ( F ) and an effective pore radius ( r ) provides an excellent fit to the data set with a near-constant pore radius, indicating that the effective porosity (1/ F ) is the controlling factor on k . In these samples, the surface area normalized to pore volume ( S por ), frequently used in permeability estimation models, varies by 1–2 orders of magnitude and is thus not a reliable proxy of the inverse effective hydraulic radius. The formation factor also exerts the primary control on induced polarization (IP) parameters, whereas Spor shows no relation to the IP parameters. A strong linear relationship is found between IP parameters (imaginary conductivity and normalized chargeability) and surface conductivity, although the proportionality factor is significantly lower than those observed in more permeable rocks and sediments. Apparent relationships between the polarization strength-derived and time constant-derived geophysical length scales and the effective hydraulic radius appear to be driven by variations in the electrochemical parameters (i.e., specific polarizability and diffusion coefficient). Overall, these findings emphasize that predicting hydraulic properties from electrical measurements in fine-grained rocks remains challenging and requires further investigation into the electrochemical properties involved.

58 GEOSCIENCES↗

Effects of Nonaqueous Electrolytes on the Performance of Primary Lithium/Air Batteries

The factors affecting the cell performance of non-aqueous electrolytes in primary Li/air batteries operated in an ambient environment were investigated. Four organic additives or co-solvents were also evaluated in electrolytes for Li/air batteries. It has been found that the polarity of an electrolyte is a critical factor for the performance of Li/air batteries. This factor overweighs the effects from the viscosity, ionic conductivity, and oxygen solubility of the electrolytes. In addition, the volume of electrolyte added to a cell significantly affects the discharge performance of a Li/air battery. The strong Lewis base tris(pentafluorophenyl)borane reduces the discharge capacity of a Li/air battery even though its ability to dissolve a certain amount of lithium oxide was supposed to improve the cell performance of Li/air batteries. Addition of two crown ethers, 12-crown-4 and 15-crown-5, especially the former one, can significantly improve the discharge performance of the Li/air cells with electrolytes containing about 15% by weight of such compounds as co-solvents. However, addition of 18-crown-6 decreases the cell performance. The differences among the three crown ethers were investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The foundations of space biology and medicine. Volume 2: Ecological and physiological bases of space biology and medicine. Part 3: Effect on the organism of dynamic flight factors. Chapter 1: Principles of gravitational biology

The physical principles of gravitation are discussed, such as gravitational and intertial forces, weight and mass, weightlessness, size and scale effects, scale limits of gravitational effects, and gravity as a biogenic factor. The behavior of the accelerative force gravitation, is described. This law proposes and quantifies the mutual gravitational attraction existing between all bodies of matter, the force being proportional to the product of masses, and inversely related to the square of the distance separating them. Gravity orientation, chronic acceleration, and hematology are examined. Systematic responses, such as circulation and renal functions, are also considered, along with animal response to a decreased acceleration field and physiology of hyper- and hypodynamic fields.

Smith, A. H.↗

Structurally Frustrated Remeika Phases: Tolerance Factor and Non-Kramers’ Ion Effects

Quantum materials that are found on the verge of structural, magnetic, and electronic instabilities are deep reservoirs for exotic phenomena. Our criteria to study the reported Ln 5 Ru 6 Sn 18 (Ln = Gd, Tb) are guided by the tolerance factor for Remeika phases─a class of intermetallic compounds with the general formula A 3 M 4 X 13 (where A = rare-earth element, M = transition metal, and X = tetrel), which can be viewed as structural analogues of pseudoperovskites (4 × ABX 3 ), with one of the tetrel atoms occupying the A-site. We have grown single crystals, up to 0.5 cm on the largest facet, of Gd 5 Ru 6 Sn 18 (a = 13.8052(12) Å) and Tb 5 Ru 6 Sn 18 (a = 13.7825(9) Å), which we expect to be on the verge of a formation instability. Bulk magnetic, heat capacity, and electrical transport measurements reveal unusual behavior that originates from the trivalent Gd and Tb ions, with deviations from typical metallic behavior and magnetic ordering that is short-range or disrupted in some other way. Furthermore, to better understand these phenomena, single-crystal neutron diffraction is investigated, which reveals short-range correlations among the partially occupied Tb and Sn sublattices, with 3D-ΔPDF analysis supporting direction-dependent local order. Taken together, these measurements show the utility of using tolerance factors in identifying materials that are likely to exhibit complex phenomena and uncover environments where a formation instability may strongly impact emergent bulk magnetic and electronic phenomena.

36 MATERIALS SCIENCE↗

WE-E-BRB-00: Motion Management for Pencil Beam Scanning Proton Therapy

Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed. Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian.; H. Li, Na.

60 APPLIED LIFE SCIENCES↗

WE-E-BRB-01: Personalized Motion Management Strategies for Pencil Beam Scanning Proton Therapy

Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed. Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian.; H. Li, Na.

60 APPLIED LIFE SCIENCES↗

WE-E-BRB-02: Implementation of Pencil Beam Scanning (PBS) Proton Therapy Treatment for Liver Patient

Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed. Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian.; H. Li, Na.

60 APPLIED LIFE SCIENCES↗

WE-E-BRB-03: Implementation of PBS Proton Therapy Treatment for Free Breathing Lung Cancer Patients

Strategies for treating thoracic and liver tumors using pencil beam scanning proton therapy Thoracic and liver tumors have not been treated with pencil beam scanning (PBS) proton therapy until recently. This is because of concerns about the significant interplay effects between proton spot scanning and patient’s respiratory motion. However, not all tumors have unacceptable magnitude of motion for PBS proton therapy. Therefore it is important to analyze the motion and understand the significance of the interplay effect for each patient. The factors that affect interplay effect and its washout include magnitude of motion, spot size, spot scanning sequence and speed. Selection of beam angle, scanning direction, repainting and fractionation can all reduce the interplay effect. An overview of respiratory motion management in PBS proton therapy including assessment of tumor motion and WET evaluation will be first presented. As thoracic tumors have very different motion patterns from liver tumors, examples would be provided for both anatomic sites. As thoracic tumors are typically located within highly heterogeneous environments, dose calculation accuracy is a concern for both treatment target and surrounding organs such as spinal cord or esophagus. Strategies for mitigating the interplay effect in PBS will be presented and the pros and cons of various motion mitigation strategies will be discussed. Learning Objectives: Motion analysis for individual patients with respect to interplay effect Interplay effect and mitigation strategies for treating thoracic/liver tumors with PBS Treatment planning margins for PBS The impact of proton dose calculation engines over heterogeneous treatment target and surrounding organs I have a current research funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian; L. Lin, I have a current funding from Varian Medical System under the master agreement between University of Pennsylvania and Varian.; H. Li, Na.

60 APPLIED LIFE SCIENCES↗

Improving Durability of Turbine Components Through Trenched Film Cooling and Contoured Endwalls

The experimental and computational studies of the turbine endwall and vane models completed in this research program have provided a comprehensive understanding of turbine cooling with combined film cooling and TBC. To correctly simulate the cooling effects of TBC requires the use of matched Biot number models, a technique developed in our laboratories. This technique allows for the measurement of the overall cooling effectiveness which is a measure of the combined internal and external cooling for a turbine component. The overall cooling effectiveness provides an indication of the actual metal temperature that would occur at engine conditions, and is hence a more powerful performance indicator than the film effectiveness parameter that is commonly used for film cooling studies. Furthermore these studies include the effects of contaminant depositions which are expected to occur when gas turbines are operated with syngas fuels. Results from the endwall studies performed at Penn State University and the vane model studies performed at the University of Texas are the first direct measurements of the combined effects of film cooling and TBC. These results show that TBC has a dominating effect on the overall cooling effectiveness, which enhances the importance of the internal cooling mechanisms, and downplays the importance of the film cooling of the external surface. The TBC was found to increase overall cooling effectiveness by a factor of two to four. When combined with TBC, the primary cooling from film cooling holes was found to be due to the convective cooling within the holes, not from the film effectiveness on the surface of the TBC. Simulations of the deposition of contaminants on the endwall and vane surfaces showed that these depositions caused a large increase in surface roughness and significant degradation of film effectiveness. However, despite these negative factors, the depositions caused only a slight decrease in the overall cooling effectiveness on the endwall, and in some cases a slight increase in overall cooling effectiveness on the vane model. This was attributed to the insulating effects of the depositions which compensated for the negative factors.

Bogard, David G.↗

Criticality concerns of a group actinide co-crystallization separations approach to used nuclear fuel recycling

We report the co-crystallization of hexavalent actinides with uranyl nitrate hexahydrate has been established as a viable approach to achieving group actinide separation in used nuclear fuel recycle while avoiding the difficulties associated with the solvent-extraction process altogether. A preliminary neutronics safety analysis has been performed to alleviate criticality concerns associated with this group hexavalent actinide co-crystallization approach. The basic uranyl nitrate hexahydrate material compositions used are representative of used fuel found at commercial pressurized water reactors all around the U.S. This material is subsequently doped with various percentages of either typical reactor grade plutonium or with the total transuranic vector, replacing the uranium atoms in the crystal lattice structure. Infinite and effective neutron multiplication factors were calculated using the state-of-the-art Monte Carlo neutron transport code MCNP in a variety of plausible material configurations, assuming an acceptable safety limit for criticality to be an effective neutron multiplication factor less than 0.95. The results indicate that the crystal structures form a very subcritical intrinsic geometry even with six water molecules being incorporated into the crystal structure. In conclusion, the results of this research suggest that significant opportunity exists for the safe transfer of the group actinide separation approach from a laboratory to an operational scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single-hole physics in GaAs/AlGaAs double quantum dot system with strong spin–orbit interaction

There is rapidly expanding interest in exploiting the spin of valence-band holes rather than conduction-band electrons for spin qubit semiconductor circuits composed of coupled quantum dots. The hole platform offers stronger spin–orbit interaction (SOI), large difference between in-dot-plane and out-of-dot-plane g-factors, i.e. g-factor anisotropy, and a significantly reduced hyperfine coupling to nuclei in the host material. These attributes collectively can deliver fast all-electric coherent spin manipulation, efficient spin-flip inter-dot tunneling channels, a voltage tunable effective g-factor, a g-factor adjustable to nearly zero in an appropriately oriented external magnetic field, and long spin relaxation and coherence times. In this work, we review our recent work on the physics of heavy holes confined in a planar GaAs/AlGaAs double quantum dot system with strong SOI. For a single-hole, we have performed resonant tunneling magneto-spectroscopy to extract spin-flip and spin-conserving tunneling strengths, implemented spin-flip Landau–Zener–Stückelberg–Majorana (LZSM) interferometry, determined the spin relaxation time T 1 as a function of magnetic field using a fast single-shot latched charge technique, electrically tuned the effective g-factor revealed by electric dipole spin resonance, and found signatures of the hyperfine interaction and dynamic nuclear polarization with holes. For two-holes, we have measured the energy spectrum in the presence of strong SOI (and so not limited by Pauli spin blockade), quantified the heavy-hole (HH) g-factor anisotropy on tilting the magnetic field, described a scheme to employ HHs whose g-factor is tunable to nearly zero for an in-plane magnetic field for a coherent photon-to-spin interface, and observed a well-defined LZSM interference pattern at small magnetic fields on pulsing through the singlet-triplet anti-crossing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of backscattering on nonlinear distortions of the scale factor of a laser gyro with a rectangular bias

We report the results of measurements of nonlinear scale factor corrections, resulting from the backscattering effect in a laser gyro with a rectangular bias. It is shown that taking conservative and dissipative backscattering components into account allows one to obtain analytical relationships that adequately describe the frequency response of a laser gyroscope over the entire working range of angular velocities. Using these relationships to correct the frequency response of a laser gyroscope makes it possible to reduce the value of nonlinear corrections to 1 – 2 ppm. (laser gyroscopes)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Global collocation methods for approximation and the solution of partial differential equations

Polynomial interpolation methods are applied both to the approximation of functions and to the numerical solutions of hyperbolic and elliptic partial differential equations. The derivative matrix for a general sequence of the collocation points is constructed. The approximate derivative is then found by a matrix times vector multiply. The effects of several factors on the performance of these methods including the effect of different collocation points are then explored. The resolution of the schemes for both smooth functions and functions with steep gradients or discontinuities in some derivative are also studied. The accuracy when the gradients occur both near the center of the region and in the vicinity of the boundary is investigated. The importance of the aliasing limit on the resolution of the approximation is investigated in detail. Also examined is the effect of boundary treatment on the stability and accuracy of the scheme.

Solomonoff, A.↗

Effects of codon optimization on coagulation factor IX translation and structure: Implications for protein and gene therapies

Synonymous codons occur with different frequencies in different organisms, a phenomenon termed codon usage bias. Codon optimization, a common term for a variety of approaches used widely by the biopharmaceutical industry, involves synonymous substitutions to increase protein expression. It had long been presumed that synonymous variants, which, by definition, do not alter the primary amino acid sequence, have no effect on protein structure and function. However, a critical mass of reports suggests that synonymous codon variations may impact protein conformation. To investigate the impact of synonymous codons usage on protein expression and function, we designed an optimized coagulation factor IX (FIX) variant and used multiple methods to compare its properties to the wild-type FIX upon expression in HEK293T cells. We found that the two variants differ in their conformation, even when controlling for the difference in expression levels. Using ribosome profiling, we identified robust changes in the translational kinetics of the two variants and were able to identify a region in the gene that may have a role in altering the conformation of the protein. Our data have direct implications for codon optimization strategies, for production of recombinant proteins and gene therapies.

59 BASIC BIOLOGICAL SCIENCES↗

Towards Quantitation of the Effects of Renal Impairment and Probenecid Inhibition on Kidney Uptake and Efflux Transporters, Using Physiologically Based Pharmacokinetic Modelling and Simulations

The kidney is a major drug-eliminating organ. Renal impairment or concomitant use of transporter inhibitors may decrease active secretion and increase exposure to a drug that is a substrate of kidney secretory transporters. However, prediction of the effects of patient factors on kidney transporters remains challenging because of the multiplicity of transporters and the lack of understanding of their abundance and specificity. The objective of this study was to use physiologically based pharmacokinetic (PBPK) modelling to evaluate the effects of patient factors on kidney transporters. Methods Models for three renally cleared drugs (oseltamivir carboxylate, cidofovir and cefuroxime) were developed using a general PBPK platform, with the contributions of net basolateral uptake transport (T up,b ) and apical efflux transport (T eff,a ) being specifically defined. Results and Conclusion We demonstrated the practical use of PBPK models to: (1) define transporter-mediated renal secretion, using plasma and urine data; (2) inform a change in the system-dependent parameter (C10-fold reduction in the functional ‘proximal tubule cells per gram kidney’) in severe renal impairment that is responsible for the decreased secretory transport activities of test drugs; (3) derive an in vivo, plasma unbound inhibition constant of T up,b by probenecid (B1 lM), based on observed drug interaction data; and (4) suggest a plausible mechanism of probenecid preferentially inhibiting T up,b in order to alleviate cidofovir-induced nephrotoxicity.

59 BASIC BIOLOGICAL SCIENCES↗

Wavelength Scaling of Widely-Tunable Terahertz Quantum-Cascade Metasurface Lasers

Terahertz (THz) external-cavity lasers based on quantum-cascade (QC) metasurfaces are emerging as widely-tunable, single-mode sources with the potential to cover the 1--6 THz range in discrete bands with milliwatt-level output power. By operating on an ultra-short cavity with a length on the order of the wavelength, the QC vertical-external-cavity surface-emitting-laser (VECSEL) architecture enables continuous, broadband tuning while producing high quality beam patterns and scalable power output. The methods and challenges for designing the metasurface at different frequencies are discussed. As the QC-VECSEL is scaled below 2 THz, the primary challenges are reduced gain from the QC active region, increased metasurface quality factor and its effect on tunable bandwidth, and larger power consumption due to a correspondingly scaled metasurface area. At frequencies above 4.5 THz, challenges arise from a reduced metasurface quality factor and the excess absorption that occurs from proximity to the Reststrahlen band. The results of four different devices — with center frequencies 1.8 THz, 2.8 THz, 3.5 THz, and 4.5 THz — are reported. Each device demonstrated at least 200 GHz of continuous single-mode tuning, with the largest being 650 GHz around 3.5 THz. The limitations of the tuning range are well modeled by a Fabry-Pérot cavity which accounts for the reflection phase of the metasurface and the effect of the metasurface quality factor on laser threshold. Lastly, the effect of different output couplers on device performance is studied, demonstrating a significant trade-off between the slope efficiency and tuning bandwidth.

47 OTHER INSTRUMENTATION↗