Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW - AIRFOILS - CASCADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Development of inter-grid-cell lateral unsaturated and saturated flow model in the E3SM Land Model (v2.0)

Abstract. The lateral transport of water in the subsurface is important in modulating terrestrial water energy distribution. Although a few land surface models have recently included lateral saturated flow within and across grid cells, it is not a default configuration in the Climate Model Intercomparison Project version 6 experiments. In this work, we developed the lateral subsurface flow model within both unsaturated and saturated zones in the Energy Exascale Earth System Model (E3SM) Land Model version 2 (ELMv2.0). The new model, called ELMlat, was benchmarked against PFLOTRAN, a 3D subsurface flow and transport model, for three idealized hillslopes that included a convergent hillslope, divergent hillslope, and tilted V-shaped hillslope with variably saturated initial conditions. ELMlat showed comparable performance against PFLOTRAN in terms of capturing the dynamics of soil moisture and groundwater table for the three benchmark hillslope problems. Specifically, the mean absolute errors (MAEs) of the soil moisture in the top 10 layers between ELMlat and PFLOTRAN were within 1 %±3 %, and the MAEs of water table depth were within ±0.2 m. Next, ELMlat was applied to the Little Washita experimental watershed to assess its prediction of groundwater table, soil moisture, and soil temperature. The spatial pattern of simulated groundwater table depth agreed well with the global groundwater table benchmark dataset generated from a global model calibrated with long-term observations. The effects of lateral groundwater flow on the energy flux partitioning were more prominent in lowland areas with shallower groundwater tables, where the difference in simulated annual surface soil temperature could reach 0.3–0.4 ∘C between ELMv2.0 and ELMlat. Incorporating lateral subsurface flow in ELM improves the representation of the subsurface hydrology, which will provide a good basis for future large-scale applications.

58 GEOSCIENCES↗

Understanding the relative importance of vertical and horizontal flow in ice-wedge polygons

Abstract. Ice-wedge polygons are common Arctic landforms. The future of these landforms in a warming climate depends on the bidirectional feedback between the rate of ice-wedge degradation and changes in hydrological characteristics. This work aims to better understand the relative roles of vertical and horizontal water fluxes in the subsurface of polygonal landscapes, providing new insights and data to test and calibrate hydrological models. Field-scale investigations were conducted at an intensively instrumented location on the Barrow Environmental Observatory (BEO) near Utqiaġvik, AK, USA. Using a conservative tracer, we examined controls of microtopography and the frost table on subsurface flow and transport within a low-centered and a high-centered polygon. Bromide tracer was applied at both polygons in July 2015 and transport was monitored through two thaw seasons. Sampler arrays placed in polygon centers, rims, and troughs were used to monitor tracer concentrations. In both polygons, the tracer first infiltrated vertically until encountering the frost table and was then transported horizontally. Horizontal flow occurred in more locations and at higher velocities in the low-centered polygon than in the high-centered polygon. Preferential flow, influenced by frost table topography, was significant between polygon centers and troughs. Estimates of horizontal hydraulic conductivity were within the range of previous estimates of vertical conductivity, highlighting the importance of horizontal flow in these systems. This work forms a basis for understanding complexity of flow in polygonal landscapes.

54 ENVIRONMENTAL SCIENCES↗

Particle Flow Distribution in a Fluidized-Particles Multitube Solar Receiver

A fluidized-particles two-tube solar receiver was tested at ambient temperature at PROMES Laboratory to investigate the influence of an inhomogeneous solar flux density on the particle mass flow rate between the tubes. The principle of this 3rd generation solar receiver is to fluidize the particles in a container, called dispenser, in which the tubes’ bottom are immersed. The fluidized particles are flowing upward the tubes by applying an overpressure in the dispenser. Air velocities are changed inside the tubes, thanks to air mass flow controllers, to represent temperature heterogeneity between the tubes. Air velocities from 0.05 up to 0.52 m/s were tested, both in homogeneous and heterogeneous conditions. In the heterogeneous ones, the differences in air velocity between the tubes aim to mimic a difference in temperature from 20 to 100 % with homogeneous air flow rates injected. The following conclusions were drawn. First, the particle mass flux in the tubes are the same with homogeneous air velocities, each one following a calibration map previously obtained. Second, different air velocities lead to different particle mass flux. Third, the rise of the total particle mass flux diminishes the pressure in the dispenser. Four, this diminution of pressure leads to a decrease of the particle mass flow rate of the tube with the lower air velocity. This influence can lead in some cases to the stop of the fluidized bed circulation in the affected tube.

Sahuquet, Guillaume (ORCID:0000000302752890)↗

Modeling and simulations of hydrodynamic shocks in a plasma flowing across randomized ICF scale laser beams

High-energy laser beams interacting with flowing plasmas can produce a plasma response that leads to deflection of the beam, beam bending. Such beams have usually a speckle structure generated by optical smoothing techniques that reduce the spatial and temporal coherence in the laser field pattern. The cumulative plasma response from laser speckles slows down the velocity of the incoming flow by momentum conservation. For slightly super-sonic flow the cumulative plasma response to the ponderomotive force exerted by the beam speckle ensemble is the strongest, such that slowing down the flow to subsonic velocities leads eventually to the generation of a shock around the cross section of the beam. This scenario has been predicted theoretically and is confirmed here by our hydrodynamic simulations in two dimensions with speckled beams and in one dimension with a reduced model. The conditions of shock generation are given in terms of the ponderomotive pressure, speckle size and the flow velocity. The nonlinear properties of the shocks are analyzed using Rankine–Hugoniot relations. According to linear theory, temporally smoothed laser beams exhibit a higher threshold for shock generation. Numerical simulations with beams that are smoothed by spectral dispersion compare well with the linear theory results, diverging from those produced by beams with only a random phase plates in the nonlinear regime. The conditions necessary for shock generation and their effects on the laser plasma coupling in inertial confinement fusion (ICF) experiments are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrolytes for iron flow battery

A method of operating an iron redox flow battery system may comprise fluidly coupling a plating electrode of an iron redox flow battery cell to a plating electrolyte; fluidly coupling a redox electrode of the iron redox flow battery cell to a redox electrolyte; fluidly coupling a ductile plating additive to one or both of the plating electrolyte and the redox electrolyte; and increasing an amount of the ductile plating additive to the plating electrolyte in response to an increase in the plating stress at the plating electrode. In this way, ductile Fe can be plated on the negative electrode, and the performance, reliability and efficiency of the iron redox flow battery can be maintained. In addition, iron can be more rapidly produced and plated at the plating electrode, thereby achieving a higher charging rate for all iron flow batteries.

25 ENERGY STORAGE↗

Credit based flow control mechanism for use in multiple link width interconnect systems

Flow control credit management is provided when converting traffic from a first parallel link width on a first link to a second parallel link width on a second link A current value is calculated for a variable flow control credit exchange rate (R) associated with the first and second links. A first flow control credit indicator is received on the second link, and a credit amount calculated based on the first flow control credit indicator and R. A second flow control credit indicator for the credit amount is then transmitted on the first link.

42 ENGINEERING↗

Simultaneous real-time measurement of composition, flow, attenuation, density, and pipe-wallthickness in multiphase fluids

Apparatus (10) and methods for making simultaneous measurements of composition (water-cut), fluid flow, and sound attenuation in a multiphase fluid flowing (15) through a pipe (12) in real-time, using the same apparatus (10) are described. Additionally, the apparatus (10) provides real-time pipe wall thickness monitoring for observing pipe corrosion or internal deposition. Knowledge of wall thickness is necessary to correct for water-cut (oil-water composition) automatically by adjusting the liquid path length internal to the pipe (spool). The use of short duration frequency chirp excitation signals (24) enables the apparatus to provide information that can be used to extract multiple levels of information from the same measurement in multiphase fluids including the presence of a significant quantity of gas (˜60% gas volume fraction) in different flow regimes. Besides measuring steady flow, this device is useful for measurements during fast changing flows, such as for a rod-pumped well. Measurements up to about 1000 times a second can reliably be made.

Sinha, Dipen N.↗

Scalable In Situ Computation of Lagrangian Representations via Local Flow Maps

In situ computation of Lagrangian flow maps to enable post hoc time-varying vector field analysis has recently become an active area of research. However, the current literature is largely limited to theoretical settings and lacks a solution to address scalability of the technique in distributed memory. To improve scalability, we propose and evaluate the benefits and limitations of a simple, yet novel, performance optimization. Our proposed optimization is a communication-free model resulting in local Lagrangian flow maps, requiring no message passing or synchronization between processes, intrinsically improving scalability, and thereby reducing overall execution time and alleviating the encumbrance placed on simulation codes from communication overheads. To evaluate our approach, we computed Lagrangian flow maps for four time-varying simulation vector fields and investigated how execution time and reconstruction accuracy are impacted by the number of GPUs per compute node, the total number of compute nodes, particles per rank, and storage intervals. Our study consisted of experiments computing Lagrangian flow maps with up to 67M particle trajectories over 500 cycles and used as many as 2048 GPUs across 512 compute nodes. In all, our study contributes an evaluation of a communication-free model as well as a scalability study of computing distributed Lagrangian flow maps at scale using in situ infrastructure on a modern supercomputer.

Sane, Sudhanshu↗

Flow cell sample generator

A sample generator system includes a fluid source and a flow cell. The sample generator system includes a sampling system in communication with the flow cell to eject a fluid sample through an orifice in the flow cell. The sample generator system includes a gas pressure at the orifice in the flow cell greater than or equal to a fluid pressure at the orifice in the flow cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In operando, non-invasive state-of-charge monitoring for redox flow batteries

This document describes techniques and systems for in operando, non-invasive SOC monitoring of redox flow batteries. The described techniques and systems allow for accurate, inexpensive, portable, and real-time methods to measure the SOC of redox flow batteries. System operators can monitor the SOC by measuring an acoustic attenuation coefficient of the electrolyte in the redox flow battery. The acoustic attenuation coefficient is measured using an ultrasonic transducer attached to a probing cell, which is connected to an electrolyte flow of a redox flow battery. The acoustic attenuation coefficient provides an accurate, real-time SOC measurement that is generally insensitive to varying operational temperatures of the electrolyte solution.

25 ENERGY STORAGE↗

Thermal-hydraulic and Fuel Performance Scoping Studies of a Flowing Water Capsule in TREAT

The restart of the Transient Reactor Test (TREAT) facility has provided a much needed capability for integral transient testing of nuclear fuel. This testing is necessary to qualify new fuel concepts such as those developed under the Accident Tolerant Fuel (ATF) program, increasing the burnup limit of light water reactor (LWR) fuels, or a variety of other programs under the Advanced Fuels Campaign (AFC). The ATF campaign has been the main driver behind the development and implementation of a variety of capsules for TREAT experiments. The Separate-Effect Test Holder (SETH) was a dry capsule that enabled testing of ATF concepts under reactivity-initiated accident (RIA) heating conditions. Following SETH, the Static Environment Rodlet Transient Test Apparatus (SERTTA) was developed to enable RIA testing in a static water environment. In efforts to support the need for future Loss-of-Coolant Accident (LOCA) tests, the Transient Water Irradiation System for TREAT (TWIST) capsule has been developed that allows for water to drain from around the fuel rod and lower the pressure to simulate LOCA conditions. All these capsules that have been developed for LWR fuel testing all lack the capability for forced convective cooling which in some applications may limit their ability to test under prototypic conditions. A design and modeling effort has been started to modify the TWIST capsule by adding a flow tube and impeller that can create flowing coolant conditions for the fuel rod. RELAP5-3D and BISON models are being used to study the differences between RIA, LOCA, Anticipated Operational Occurrences (AOO), LWR power cycling, and other transient scenarios under flowing conditions capable in the flowing capsule and the current stagnant water capsules (SERTTA and TWIST). The scoping study will provide guidance on the needed capabilities for the flowing capsule and the limitations of the currently developed capsule for LWR testing in TREAT.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alkaline manganese redox flow battery with inhibitor

A redox flow battery includes a redox flow cell and a supply and storage system external of the redox flow cell. The supply and storage system includes first and second electrolytes for circulation through the redox flow cell. The first electrolyte is a liquid electrolyte having electrochemically active manganese species with multiple, reversible oxidation states in the redox flow cell. The electrochemically active manganese species may undergo reactions that cause precipitation of manganese oxide solids. The first electrolyte includes an inhibitor that limits the self-discharge reactions. The inhibitor includes an oxoanion compound.

Davenport, Timothy↗

Methods and systems for rebalancing electrolytes for a redox flow battery system

A rebalancing reactor for a redox flow battery system may include a first side through which hydrogen gas is flowed, a second side through which electrolyte from the redox flow battery system is flowed, and a porous layer separating and fluidly coupled to the first side and the second side, wherein, the hydrogen gas and the electrolyte are fluidly contacted at a surface of the porous layer, and a pressure drop across the second side is less than a pressure drop across the porous layer. In this way, rebalancing of electrolyte charges in a redox flow battery system may be performed with increased efficiency and cost effectiveness as compared to conventional rebalancing reactors.

Evans, Craig E.↗

Flow assisted anti-fouling geometries for compact heat exchangers

A header for a heat exchanger and method for cleaning a heat exchanger in a loop without disconnecting loop components is provided. The header is in flow communication with the heat exchanger for distributing fluid through a plurality of adjacent channels. The header is connected between a main heat exchanger inlet nozzle and a channel flow distributor. A filter element is disposed within the header between the nozzle and channel flow distributor. Under normal operation, the filter element removes particulates and fouling material from the main flow stream before it enters the heat exchanger channels. During the cleaning process, fluid is injected on or through the filter element to remove particulates and fouling material through at least one outlet port. The header arrangement allows the filter element to be ‘cleaned in place’ without draining the system and disconnecting the heat exchanger or other components from the flow loop.

Carlson, Matthew David↗

Localized Flow Modification to Increase Power Capture of a Small-Scale Floating Undershot Waterwheel

The goal of the work described in this thesis is to design a flow augmentation device to increase the power capture and efficiency of a small-scale floating Under-Shot Water Wheel (USWW) currently being developed by Florida Atlantic University research funded by the U.S Department of Energy. The flow concentrator subsystem is intended to maximize the kinetic energy extracted by the marine hydrokinetic (MHK) energy collection device through modification of the local flow field across the capture plane. The primary objective is to increase the velocity and/or rate of mass inflow through the turbine through inserting a streamlined body in the region of interest. By utilizing the resulting flow field to increase hydraulic forcing on the waterwheel blades, the torque and/or RPM of the USWW can be increased. Based on experimental testing in the FAU wave tank at 1:5 prototype scale (280 mm wheel diameter) the flow concentrator was shown to produce an increase in device power coefficient of 17-55% measured over a velocity range of 0.16-0.45 m/s.

Hess, Sullivan↗

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗

Print-and-Plate Architected Electrodes for Electrochemical Transformations Under Flow

Flow cell electrodes are typically composed of porous carbon materials, such as papers, felts, and cloths. However, their random architecture hinders the fundamental characterization of electrode structure-performance relationships during in situ operation of porous electrochemical flow systems. This work describes a “print-and-plate” method that combines direct ink writing of micro-periodic lattices with a two-step metal plating process that converts them into highly conductive (sheet resistance 40 mΩ sq -1 ) electrodes. Their operando performance is assessed in an anthraquinone disulfonic acid half-cell using widefield electrochemical fluorescence microscopy, where output current and fluorescence intensity are in excellent agreement. The pressure drop associated with flow through three electrode designs is determined via simulations from which the most efficient design is identified and manufactured via print-and-plate. Confocal fluorescence microscopy is then used to create a 3D map of the state of charge (SOC) inside this print-and-plate electrode. The experimental state of the charge map is in good agreement with computational predictions. The rapid design, simulation, and fabrication of print-and-plate electrodes enable fundamental investigations of how architected porosity affects electrochemical performance under flow.

3D-printing↗

Uncertainty quantification of bank vegetation impacts on the flood flow field in the American River, California, using large‐eddy simulations

Bank vegetation plays a key role in both hydrodynamics and morphodynamics of natural rivers; however, these effects are often unaccounted for in the computational flow dynamics of natural waterways. Recent studies using the large‐eddy simulation (LES), however, have attempted to gain insights into the impacts of bank vegetation on the mean flow field of the natural rivers using a vegetation model, which applies a sink term to the momentum equations of motion. This approach accounts for the effects of the vegetation and provides a practical approach to account for the complex patches of bank vegetation in large‐scale rivers. To implement the vegetation model, a drag coefficient reflecting the overall resistance of vegetal structures to the flow is needed, but due to the lack of calibrated data and range of size, density and type of vegetation, this parameter can be a significant source of uncertainty in the model results. Here, in this study, we use uncertainty quantification (UQ) to investigate the hydrodynamics and bed shear results when a bank vegetation is incorporated in an LES model. To this end, we used the polynomial chaos expansion and Monte Carlo sampling techniques to determine the uncertainties associated with the drag coefficient in the vegetation model and from uncertainties in the bed roughness and inflow discharge. The UQ analysis provided spatially varying confidence levels for the spanwise and vertical distribution of velocity magnitude and for the bed shear stress distributions. In addition, Sobol indices were computed to indicate the relative influence that each parameter had on the overall uncertainty. In general, it was found that uncertainty in flow discharge was the dominant source of uncertainty; however, the drag coefficient in the vegetation model and the bed roughness parameter also made significant contribution to the uncertainty near the banks and bed, respectively.

54 ENVIRONMENTAL SCIENCES↗