Zero Boil-Off Tank (ZBOT) Experiment

The Zero-Boil-Off Tank (ZBOT) experiment has been developed as a small scale ISS experiment aimed at delineating important fluid flow, heat and mass transport, and phase change phenomena that affect cryogenic storage tank pressurization and pressure control in microgravity. The experiments use a simulant transparent low boiling point fluid (PnP) in a sealed transparent Dewar to study and quantify: (a) fluid flow and thermal stratification during pressurization; (b) mixing, thermal destratification, depressurization, and jet-ullage penetration during pressure control by jet mixing. The experiment will provide valuable microgravity empirical two-phase data associated with the above-mentioned physical phenomena through highly accurate local wall and fluid temperature and pressure measurements, full-field phase-distribution and flow visualization. Moreover, the experiments are performed under tightly controlled and definable heat transfer boundary conditions to provide reliable high-fidelity data and precise input as required for validation verification of state-of-the-art two-phase CFD models developed as part of this research and by other groups in the international scientific and cryogenic fluid management communities.

ISS↗

High-stress triaxial direct-shear fracturing of Utica shale and in situ X-ray microtomography with permeability measurement

The challenge of characterizing subsurface fluid flow has motivated extensive laboratory studies, yet fluid flow through rock specimens in which fractures are created and maintained at high-stress conditions remains underinvestigated at this time. The studies of this type that do exist do not include in situ fracture geometry measurements acquired at stressed conditions, which would be beneficial for interpreting the flow behavior. Therefore, this study investigates the apparent permeability induced by direct-shear fracture stimulation through Utica shale (a shale gas resource and potential caprock material) at high triaxial stress confinement and for the first time relates these values to simultaneously acquired in situ X-ray radiography and microtomography images. Change in fracture geometry and apparent permeability was also investigated at additional reduced stress states. Finite element and combined finite-discrete element modeling were used to evaluate the in situ observed fracturing process. Results from this study indicate that the increase in apparent permeability through fractures created at high-stress (22.2 MPa) was minimal relative to the intact rock (less than 1 order of magnitude increase), while fractures created at low stress (3.4 MPa) were significantly more permeable (2 to 4 orders of magnitude increase). Here, this study demonstrates the benefit of in situ X-ray observation coupled with apparent permeability measurement to analyze fracture creation in the subsurface. Our results show that the permeability induced by fractures through shale at high stress can be minor and therefore favorable in application to CO 2 sequestration caprock integrity but unfavorable for hydrocarbon recovery from unconventional reservoirs.

58 GEOSCIENCES↗

Counter-Top Thermoacoustic Refrigerator- An Experimental Investigation

Thermoacoustic phenomenon is a new alternative refrigeration technology. Though design and fabrication is complex for getting the desired effect, it is environmentally friendly and successful system showed that it is relatively easy to run compared to the traditional vapor compression refrigeration system. Currently, theories supporting the thermoacoustic refrigeration systems are yet to be comprehensive to make them commercially viable. Theoretical, experimental, and numerical studies are being done to address the thermodynamics-acoustics interactions. In this study, experimental investigations were completed to test the feasibility of the practical use of a thermoacoustic refrigerator in its counter-top form for future specific application. The system was designed and fabricated based on linear acoustic theory. Acoustic power was given by a loud speaker and thermoacoustic effects were measured in terms of the cooling effects produced at resonanance. Investigations showed that discrepancies between designed and working resonance frequency exist. Thermoacoutic cooling improved at a certain frequency, achieved when the working frequency was varied away from the design frequency. A cooling effect of 4.8 K below the ambient temperature of 23.3 deg. C was obtained from the counter-top thermoacoustic system. This system uses no refrigerants and no compressor to generate the cooling effect, a potential to be further investigated for a practical system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Viscous pour point of microquantities of fluid lubricants

A method is described involving the measurement of the viscous desolidification (pour) point of wax-free lubricant fluids. This method is especially useful for pour point testing of experimental quantities, since only six to sixteen drops of the oil are required for a single determination (automatically performed in duplicate) with nearly full recovery of the sample. The technique consists of: (1) rapidly freezing a small, predetermined amount of the oil on the side of a small test tube to form a frozen drop of given dimensions; (2) immersing duplicates of the charged and stoppered tubes into a cold bath; and (3) measuring the temperature when the drop front has moved a predetermined distance as the bath warms up.

Gardos, M. N.↗

Cardiovascular Deconditioning and Venous Air Embolism in Simulated Microgravity in the Rat

Astronauts conducting extravehicular activities undergo decompression to a lower ambient pressure, potentially resulting in gas bubble formation within the tissues and venous circulation. Additionally, exposure to microgravity produces fluid shifts within the body leading to cardiovascular deconditioning. A lower incidence of decompression illness in actual spaceflight compared with that in ground-based altitude chamber flights suggests that there is a possible interaction between microgravity exposure and decompression illness. The purpose of this study was to evaluate the cardiovascular and pulmonary effects of simulated hypobaric decompression stress using a tail suspension (head-down tilt) model of microgravity to produce the fluid shifts associated with weightlessness in conscious, chronically instrumented rats. Venous bubble formation resulting from altitude decompression illness was simulated by a 3-h intravenous air infusion. Cardiovascular deconditioning was simulated by 96 h of head-down tilt. Heart rate, mean arterial blood pressure, central venous pressure, left ventricular wall thickening and cardiac output were continuously recorded. Lung studies were performed to evaluate edema formation and compliance measurement. Blood and pleural fluid were examined for changes in white cell counts and protein concentration. Our data demonstrated that in tail-suspended rats subjected to venous air infusions, there was a reduction in pulmonary edema formation and less of a decrease in cardiac output than occurred following venous air infusion alone. Mean arterial blood pressure and myocardial wall thickening fractions were unchanged with either tail-suspension or venous air infusion. Heart rate decreased in both conditions while systemic vascular resistance increased. These differences may be due in part to a change or redistribution of pulmonary blood flow or to a diminished cellular response to the microvascular insult of the venous air embolization.

Robinson, R. R.↗

Numerical Analysis of Film Cooling at High Blowing Ratio

Computational Fluid Dynamics is used in the analysis of a film cooling jet in crossflow. Predictions of film effectiveness are compared with experimental results for a circular jet at blowing ratios ranging from 0.5 to 2.0. Film effectiveness is a surface quantity which alone is insufficient in understanding the source and finding a remedy for shortcomings of the numerical model. Therefore, in addition, comparisons are made to flow field measurements of temperature along the jet centerline. These comparisons show that the CFD model is accurately predicting the extent and trajectory of the film cooling jet; however, there is a lack of agreement in the near-wall region downstream of the film hole. The effects of main stream turbulence conditions, boundary layer thickness, turbulence modeling, and numerical artificial dissipation are evaluated and found to have an insufficient impact in the wake region of separated films (i.e. cannot account for the discrepancy between measured and predicted centerline fluid temperatures). Analyses of low and moderate blowing ratio cases are carried out and results are in good agreement with data.

El-Gabry, Lamyaa↗

Error analysis for reducing noisy wide-gap concentric cylinder rheometric data for nonlinear fluids - Theory and applications

This work discusses the propagation of errors for the recovery of the shear rate from wide-gap concentric cylinder viscometric measurements of non-Newtonian fluids. A least-square regression of stress on angular velocity data to a system of arbitrary functions is used to propagate the errors for the series solution to the viscometric flow developed by Krieger and Elrod (1953) and Pawlowski (1953) ('power-law' approximation) and for the first term of the series developed by Krieger (1968). A numerical experiment shows that, for measurements affected by significant errors, the first term of the Krieger-Elrod-Pawlowski series ('infinite radius' approximation) and the power-law approximation may recover the shear rate with equal accuracy as the full Krieger-Elrod-Pawlowski solution. An experiment on a clay slurry indicates that the clay has a larger yield stress at rest than during shearing, and that, for the range of shear rates investigated, a four-parameter constitutive equation approximates reasonably well its rheology. The error analysis presented is useful for studying the rheology of fluids such as particle suspensions, slurries, foams, and magma.

Borgia, Andrea↗

Automated High-Pressure Titration System with In Situ Infrared Spectroscopic Detection

A fully automated titration system with infrared detection was developed for investigating interfacial chemistry at high pressures. The apparatus consists of a high-pressure fluid generation and delivery system coupled to a high-pressure cell with infrared optics. A manifold of electronically actuated valves is used to direct pressurized fluids into the cell. Precise reagent additions to the pressurized cell are made with calibrated tubing loops that are filled with reagent and placed in-line with the cell and a syringe pump. The cell’s infrared optics facilitate both transmission and attenuated total reflection (ATR) measurements to monitor bulk-fluid composition and solid-surface phenomena such as adsorption, desorption, complexation, dissolution, and precipitation. Switching between the two measurement modes is accomplished with moveable mirrors that direct radiation from a Fourier transform infrared spectrometer into the cell along transmission or ATR light paths. The versatility of the high-pressure IR titration system is demonstrated with three case studies. First, we titrated water into supercritical CO2 (scCO2) to generate an infrared calibration curve and determine the solubility of water in CO2 at 50 °C and 90 bar. Next, we characterized the partitioning of water between a montmorillonite clay and scCO2 at 50 °C and 90 bar. Transmission-mode spectra were used to quantify changes in the clay’s sorbed water concentration as a function of scCO2 hydration, and ATR measurements provided insights into competitive residency of water and CO2 on the clay surface and in the interlayer. Finally, we demonstrated how time-dependent studies can be conducted with the system by monitoring the carbonation reaction of forsterite (Mg2SiO4) in water-bearing scCO2 at 50 °C and 90 bar. Immediately after water dissolved in the scCO2, a thin film of adsorbed water formed on the mineral surface, and the film thickness increased with time as the forsterite began to dissolve. However, after approximately 2.5 hours, the trend reversed, and a carbonate precipitate began to form on the forsterite surface, exposing dramatic chemical changes in the thin-water film. Collectively, these applications illustrate how the high-pressure IR titration system can provide molecular-level information about the interactions between variably wet scCO2 and minerals relevant to underground storage of CO2 (geologic carbon sequestration). The apparatus could also be utilized to study high-pressure interfacial chemistry in other areas such as catalysis, polymerization, food processing, and oil and gas recovery.

Environmental Molecular Sciences Laboratory↗

Optical measurements and tests performed in a low-gravity environment

Shadowgraph and schlieren techniques have been used on board the NASA KC-135 low-gravity simulation aircraft to measure gravity-related fluid flow occurring in various experimental configurations. These configurations included cooled and solidified ammonium chloride and water, electrodeposited cobalt in CoSO4 solution, and immiscible and crystal melt solutions. Hardware tests have also been performed for such critical optical system components as lasers and spatial filters to determine their performance and operation under low-gravity conditions. These test results will be used in the design of the various future Shuttle experiments which will utilize advanced optical measurement techniques. The design and configuration of the optical systems used to make these measurements and tests are presented, and the performance and operation of these systems and their components under low-gravity conditions are discussed. Some preliminary results are included.

Owen, R. B.↗

Calibration, Data Acquisition, and Post Analysis of Turbulent Fluid Flow in a Calibration Jet Using Hot-wire Anemometry

The Turbine Branch concentrates on the following areas: Computational Fluid Dynamics (CFD), and implementing experimental procedures to obtain physical modeling data. Hot-wire Anemometry is a valuable tool for obtaining physical modeling data. Hot-wire Anemometry is likely to remain the principal research tool for most turbulent air/gas flow studies. The Hot-wire anemometer consists of a fine wire heated by electric current. When placed in a fluid stream, the hot-wire loses heat to the fluid by forced convection. In forced convection, energy transfer is due to molecular motion imposed by an extraneous force moving fluid parcels. When the hot-wire is in "equilibrium", the rate of heat input to the wire is equal to the rate of heat loss at the wire ends. The equality between heat input and heat loss is the basis for King s equation, which relates the electrical parameters of the hot-wire to the flow parameters of the fluid. Hot-wire anemometry is based on convective heat transfer from a heated wire element placed in a fluid flow. Any change in the fluid flow condition that affects the heat transfer from the heated element will be detected virtually instantaneously by a constant-temperature Hot-wire anemometry system. The system implemented for this research is the IFA 300. The system is a fully-integrated, thermal anemometer-based system that measures mean and fluctuating velocity components in air, water, and other fluids. It also measures turbulence and makes localized temperature measurements. A constant-temperature anemometer is a bridge and amplifier circuit that controls a tiny wire at constant temperature. As a fluid flow passes over the heated sensor, the amplifier senses the bridge off-balance and adjusts the voltage to the top of the bridge, keeping the bridge in balance. The voltage on top of the bridge can then be related to the velocity of the flow. The bridge voltage is sensitive to temperature as well as velocity and so the built-in thermocouple circuit can be attached to a thermocouple that can measure the fluid temperature. Additional information is included in the original extended abstract.

Moreno, Michelle↗

Utah FORGE Friction-Permeability-Seismicity Laboratory Experiments with Non-Linear Acoustics

Laboratory experimental data on saw-cut interface of Westerly Granite and Utah Forge granitoid rocks. Experiments include velocity-stepping and fluid pressure stepping experiments. Mechanical data from 3 ISCO pumps connected to a Temco pressure vessel measure axial, confining and fault: fluid pressure (kPa), fluid flow rate (mL/min) and volume remaining in pump (mL). Non-linear acoustic data acquired via Verasonics systems connected to PZTs inside the pressure vessel give the timeshift, amplitude and RMS amplitude of the passing P-wave.

15 GEOTHERMAL ENERGY↗

Technology Transfer at Edgar Mine: Phase 1; October 2016

The objective of this project is to study the flow of fluid through the fractures and to characterize the efficiency of heat extraction (heat transfer) from the test rock mass in the Edgar Mine, managed by Colorado School of Mines in Idaho Springs, CO. The experiment consists of drilling into the wall of the mine and fracturing the rock, characterizing the size and nature of the fracture network, circulating fluid through the network, and measuring the efficiency of heat extraction from the 'reservoir' by monitoring the temperature of the 'produced' fluid with time. This is a multi-year project performed as a collaboration between the National Renewable Energy Laboratory, Colorado School of Mines and Sandia National Laboratories and carried out in phases. This report summarizes Phase 1: Selection and characterization of the location for the experiment, and outlines the steps for Phase 2: Circulation Experiments.

15 GEOTHERMAL ENERGY↗

Sandia Particle Holography Processor v. 1.0

HoloSand is a suite of MATLAB® functions for measurement of particle properties from digital holograms. Functions to read and display digital holograms are included along with scripts to extract three-dimensional particle positions, sizes, and velocities. This software is a research tool used to process experimental data. A user of this software would first record digital holograms of a particle field and then use this software to measure the three-dimensional particle information encoded in the hologram. Applications range from basic laboratory fluids research to applied particle measurements. The software has no known military applications. The software solves the diffraction integral equation to numerically refocus digital holograms and then applies the hybrid and cross-correlation methods described in the references to extract three-dimensional particle information. User input is required to read-in the hologram and select optimum settings for image segmentation.

Guildenbecher, Daniel↗

High-fidelity Experiments of Turbulent Buoyant Jets from Simultaneous Particle Image Velocimetry and Laser Induced Fluorescence

Accurate models of turbulent buoyant flows are essential for the design of nuclear reactors thermal hydraulics and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We performed experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous Particle Image Velocimetry and Laser Induced Fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The Refractive Index Matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy driven flows (e.g., natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as basis for the development of a new one that captures turbulent mixing.

42 ENGINEERING↗

Acute effects of head-down tilt and hypoxia on modulators of fluid homeostasis

In an effort to understand the interaction between acute postural fluid shifts and hypoxia on hormonal regulation of fluid homeostasis, the authors measured the responses to head-down tilt with and without acute exposure to normobaric hypoxia. Plasma atrial natriuretic peptide (ANP), cyclic guanosine monophosphate (cGMP), cyclic adenosine monophosphate (cAMP), plasma aldosterone (ALD), and plasma renin activity (PRA) were measured in six healthy male volunteers who were exposed to a head-down tilt protocol during normoxia and hypoxia. The tilt protocol consisted of a 17 degrees head-up phase (30 minutes), a 28 degrees head-down phase (1 hour), and a 17 degrees head-up recovery period (2 hours, with the last hour normoxic in both experiments). Altitude equivalent to 14,828 ft was simulated by having the subjects breathe an inspired gas mixture with 13.9% oxygen. The results indicate that the postural fluid redistribution associated with a 60-minute head-down tilt induces the release of ANP and cGMP during both hypoxia and normoxia. Hypoxia increased cGMP, cAMP, ALD, and PRA throughout the protocol and significantly potentiated the increase in cGMP during head-down tilt. Hypoxia had no overall effect on the release of ANP, but appeared to attenuate the increase with head-down tilt. This study describes the acute effects of hypoxia on the endocrine response during fluid redistribution and suggests that the magnitude, but not the direction, of these changes with posture is affected by hypoxia.

Posture↗

CFD Verification and Validation of Wire-Wrapped Pin Assemblies

TerraPower is participating in a cooperative project among industry, the national lab system, and academia to perform Verification and Validation (V and V) of Computational Fluid Dynamics (CFD) methods for predicting the flow and heat transfer within liquid-metal-cooled nuclear fuel assemblies with wire-wrapped fuel pins. This project, consisting of both experimental and numerical components, uses surrogate fluids and electrically heated fuel pins to substitute for the liquid metal coolant and the nuclear heat source. The experiments include both unheated assemblies to measure the flow velocities with Laser Doppler Velocimetry (LDV) and Particle Image Velocimetry (PIV), as well as heated assemblies to measure the temperatures of the fluid and the simulated fuel pins with thermocouples. Both sets of experiments also measure the pressure at multiple locations in the system. The numerical component of this work involves high-fidelity Large-Eddy Simulation (LES) modeling and industry-standard Reynolds-Averaged Navier-Stokes (RANS) modeling of the experiments. Furthermore, the experiments and simulations will be conducted on two duct geometries: the first is a non-deformed hexagonal duct that has flat internal duct faces that represents a beginning of life geometry. The other is a deformed duct where the internal hexagonal flow area enlarges then decreases along the axial height to represent the changes that occur to the duct geometry from pressure and irradiation effects in the core. This paper describes the methods and results of the industrial, RANS-based CFD code verification, solution verification, and solution validation. The V and V simulations are being performed for the following experiment test geometries: - Isothermal non-deformed bundle; - Heated non-deformed bundle; - Isothermal deformed bundle; - Heated deformed bundle. These flows have been computed at first with the pre-test design specifications, without the aid of any experimental results. Later, post-test calculations will be performed incorporating the actual test conditions and input from some of the experimental results. These RANS simulations of helically wire-wrapped fuel assemblies employ meshes of bare pins without the wire-wrap in the bundle. The effect of wire-wrap on the flow is accounted for by introducing a momentum source into the governing fluid equations. The momentum source is only applied to cells corresponding to the location of the wire-wrap, and its components in each cell are based on the local flow field. This methodology simplifies the geometry and mesh generation and reduces the cell count, while still capturing the effects of the wire-wrap. The momentum source approach is used for all of the assembly simulations performed in this study. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermophysical Properties of Pore-confined Supercritical CO2 by Vibrating Tube Densimetry

Properties of fluids confined in pore systems are needed for modeling fluid flow, fluid-rock interactions, and changes in reservoir porosity. The properties of CO2-rich fluids are particularly relevant to geothermal heat mining using carbon dioxide instead of water. While manometric, volumetric, and gravimetric techniques have been used successfully to investigate adsorption of low-density subcritical vapors, the results have not been satisfactory at higher, liquid-like densities of supercritical fluids. Even if the requirements for high experimental accuracy in the neighborhood of the critical region were met, these methods are fundamentally unable to deliver the total adsorption capacity, since the properties (e.g. density) of the adsorbed phase are in general not known. In this work we utilize vibrating tube densimetry for the first time to measure the total amount of fluid contained within a mesoporous solid. The method is first demonstrated using propane at subcritical and supercritical temperatures between 35 C and 97 C confined in silica aerogel (density 0.2 g cm-3, porosity 90%) that was synthesized inside Hastelloy U-tubes. Sorption and desorption of carbon dioxide on the same solid was measured at 35 C at pressures to 120 bar (density to 0.767 g cm-3). The results show total adsorption increasing monotonically with increasing pressure, unlike excess adsorption isotherms which show a maximum close to the critical density.

36 MATERIALS SCIENCE↗

Elliptic flow fluctuations in heavy ion collisions and the perfect fluid hypothesis

We analyze the recently measured v{sub 2} fluctuation in the context of establishing the degree of fluidity of the matter produced in heavy ion collisions. We argue that flow observables within systems with a non-negligible mean free path should acquire a 'dynamical' fluctuation, due to the random nature of each collision between the system's degrees of freedom. Because of this, v{sub 2} fluctuations can be used to estimate the Knudsen number of the system produced at the Relativistic Heavy Ion Collider (RHIC). To illustrate this quantitatively, we apply the UrQMD model, with scaled cross sections, to show that collisions at RHIC have a Knudsen number at least one order of magnitude below the expected value for an interacting hadron gas. Furthermore, we argue that the Knudsen number is also bound from below by the v{sub 2} fluctuation data, because too small a Knudsen number would break the observed scaling of v{sub 2} fluctuations due to the onset of turbulent flow. We propose, therefore that v{sub 2} fluctuation measurements, together with an understanding of the turbulent regime for relativistic hydrodynamics, will provide an upper as well as a lower limit for the Knudsen number. We also argue that an energy scan of v{sub 2} fluctuations could shed light on the onset of the fluid regime.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗