Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Space Charge Simulations in the Fermilab Recycler for PIP-II

Proton Improvement Plan-II (PIP-II) is Fermilab's plan for providing powerful, high-intensity proton beams to the laboratory's experiments. Upgrades are foreseen for the recycler which will cope with bunches containing fifty percent more beam. Of particular concern is large space charge tune shifts caused by the intensity increase. Simulations performed using Synergia are detailed focusing on the space charge footprint.

43 PARTICLE ACCELERATORS↗

Performance Analysis for the New g-2 Experiment at Fermilab

The new g-2 experiment at Fermilab aims to measure the muon anomalous magnetic moment to a precision of ±0.14 ppm - a fourfold improvement over the 0.54 ppm precision obtained in the g-2 BNL E821experiment. Achieving this goal requires the delivery of highly polarized 3.094 GeV/c muons with a narrow ±0.5% Δp/p acceptance to the g-2 storage ring. In this study, we describe a muon capture and transport scheme that should meet this requirement. First, we present the conceptual design of our proposed scheme wherein we describe its basic features. Then, we detail its performance numerically by simulating the pion production in the (g-2) production target, the muon collection by the downstream beamline optics as well as the beam polarization and spin-momentum correlation up to the storage ring. The sensitivity in performance of our proposed channel against key parameters such as magnet apertures and magnet positioning errors is analyzed

43 PARTICLE ACCELERATORS↗

Optics Corrections with LOCO in the Fermilab Booster

The optics of the Fermilab Booster has been corrected with LOCO (Linear Optics from Closed Orbits). However, the first corrections did not show any improvement in capture efficiency at injection. A detailed analysis of the results showed that the problem lay in the MADX optics file. Both the quadrupole and chromatic strengths were originally set as constants independent of beam energy. However, careful comparison between the measured and calculated tunes and chromatcity show that these strengths are energy dependent. After the MADX model was modified with these new energy dependent strengths, the LOCO corrected lattice has been applied to Booster. The effect of the corrected lattice will be discussed here.

43 PARTICLE ACCELERATORS↗

Study of Fast Instability in Fermilab Recycler

One of the factors which may limit the intensity in the Fermilab Recycler is a fast transverse instability. It develops within a hundred turns and, in certain conditions, may lead to a beam loss. Various peculiar features of the instability: its occurrence only above a certain intensity threshold, and only in horizontal plane, as well as the rate of the instability, suggest that its cause is electron cloud. We studied the phenomena by observing the dynamics of stable and unstable beam. We found that beam motion can be stabilized by a clearing bunch, which confirms the electron cloud nature of the instability. The findings suggest electron cloud trapping in Recycler combined function mag-nets. Bunch-by-bunch measurements of betatron tune show a tune shift towards the end of the bunch train and allow the estimation of the density of electron cloud and the rate of its build-up. The experimental results are in agreement with numerical simulations of electron cloud build-up and its interaction with the beam.

43 PARTICLE ACCELERATORS↗

Investigation of Thermal Acoustic Effects on SRF Cavities within CM1 at Fermilab

Two TESLA-style 8-cavity cryomodules have been operated at Fermilab Accelerator Science and Technology (FAST), formerly the Superconducting Radio Frequency (SRF) Accelerator Test Facility. Operational instabilities were revealed during Radio Frequency (RF) power studies. These observations were complemented by the characterization of thermal acoustic effects on cavity microphonics manifested by apparent noisy boiling of helium involving vapor bubble and liquid vibration. The thermal acoustic measurements also consider pressure and temperature spikes which drive the phenomenon at low and high frequencies.

43 PARTICLE ACCELERATORS↗

Mechanical Stability Study for Integrable Optics Test Accelerator at Fermilab

The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p⁺) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device component support. Two design lengths; (8) 4 m and (2) 2.8 m long girders with identical cross section completely encompass the ring. This study focuses on the 4 m length girder and the development of a working prototype. Hydrostatic Level Sensor (HLS), temperature, metrology and fast motion measurements characterize the anticipated mechanical stability of the IOTA ring.

43 PARTICLE ACCELERATORS↗

End-to-End Beam Simulations for the New Muon G-2 Experiment at Fermilab

The aim of the new muon g-2 experiment at Fermilab is to measure the anomalous magnetic moment of the muon with an unprecedented uncertainty of 140 ppb. A beam of positive muons required for the experiment is created by pion decay. Detailed studies of the beam dynamics and spin polarization of the muons are important to predict systematic uncertainties in the experiment. In this paper, we present the results of beam simulations and spin tracking from the pion production target to the muon storage ring. The end-to-end beam simulations are developed in Bmad and include the processes of particle decay, collimation (with accurate representation of all apertures) and spin tracking.

43 PARTICLE ACCELERATORS↗

Status of the Perpendicular Biased 2nd Harmonic Cavity for the Fermilab Booster

This is a status report on the 2nd harmonic cavity for the Fermilab Booster as part of the Proton Improvement Plan (PIP) for increasing beam transmission efficiency, and thus reducing losses. A set of tuner rings has been procured and is undergoing quality control tests. The Y567 tube for driving the cavity has been successfully tested at both injection and extraction frequencies. A cooling scheme for the tuner and cavity has been developed after a thorough thermal analysis of the system. RF windows have been procured and substantial progress has been made on the mechanical designs of the cavity and the bias solenoid. Finally, the goal is to have a prototype cavity ready for testing by the end of 2017.

42 ENGINEERING↗

Reduction of Coherent Betatron Oscillations Using RF Electric Fields in the Fermilab Muon g-2 Experiment

The Fermilab Muon g-2 experiment aims to measure the muon anomalous magnetic moment with a 140 parts-per-billion precision to investigate the greater than 3 standard deviation difference between the Standard Model prediction and the previous measurement by the BNL Muon g-2 experiment. The coherent betatron oscillation (CBO) beam effects must be corrected for in the decay-positron time spectra fits used in high precision muon storage ring based anomalous magnetic moment measurements. This MC simulation study indicates that the application of radio frequency (RF) electric fields to the muon storage ring beam can reduce the CBO amplitude by up to a factor of 10, as well to increase the symmetry of the beam phase space. This is achieved by correcting the mismatched oscillation phases between the high and low momentum muon populations by modulating the muon beam betatron oscillation frequencies with off-resonance RF fields.

43 PARTICLE ACCELERATORS↗

Lost Muon Studies for the Muon g-2 Experiment at Fermilab

The Fermilab Muon g-2 experiment aims to measure the muon anomalous magnetic moment aμ with an unprecedented precision of 140 parts per billion (ppb), a four-fold improvement over the 540~ppb precision obtained by the BNL Muon g-2 Experiment. This study presents preliminary work on estimating the muon losses by using double coincidences in the calorimeters.

43 PARTICLE ACCELERATORS↗

Commissioning and Operation of FAST Electron Linac at Fermilab

We report results of the beam commissioning and first operation of the 1.3 GHz superconducting RF electron linear accelerator at Fermilab Accelerator Science and Technology (FAST) facility. Construction of the linac was completed and the machine was commissioned with beam in 2017. The maximum total beam energy of about 300 MeV was achieved with the record energy gain of 250 MeV in the ILC-type SRF cryomodule. The pho-toinjector was tuned to produce trains of 200 pC bunches with a frequency of 3 MHz at a repetition rate of 1 Hz. This report describes the aspects of machine commission-ing such as tuning of the SRF cryomodule and beam optics optimization. We also present highlights of an experimental program carried out parasitically during the two-month run, including studies of wake-fields, and advanced beam phase space manipulation.

43 PARTICLE ACCELERATORS↗

Tooling Systems for the Assembly and Integration of the SSR1 Cryomodule for PIP-II Project at Fermilab

In this paper we present the assembly strategy and tooling design for the SSR1 cryomodule from the cavity string to the final module. Several challenging aspects were considered to minimize undesired stresses on critical components, to preserve the alignment of cavities and solenoids during final assembly, and ultimately to meet the technical requirements of the PIP-II project at Fermilab.

43 PARTICLE ACCELERATORS↗

Preparation and Qualification of Jacketed SSR1 Cavities for String Assembly at Fermilab

The qualification of dressed 325 MHz Single Spoke Resonators type 1 (SSR1) to meet technical requirements is an important milestone in the development of the SSR1 cryomodule for the PIP-II Project at Fermilab. This paper reports the procedures and lessons learned in processing and preparing these cavities for horizontal cold testing prior to integration into a cavity string assembly.

43 PARTICLE ACCELERATORS↗

Development of Nb3Sn Coatings for Superconducting RF Cavities at Fermilab

Nb3Sn films are a promising alternative material for su-perconducting RF cavities, with proven high quality factors at medium fields and predictions for increased superheating field as well. In this contribution, we de-scribe the latest results from the Fermilab Nb3Sn SRF program. Early experiments have been focused on single cell 1.3 GHz cavities. We briefly review efforts to bring the parameters used in the coating process into a range where they produce uniform surfaces without regions showing signs of excess tin or thin/uncoated areas. We then present the latest cavity results, after modifications to the coating recipe based on feedback from film appear-ance and RF performance. These results show high Q0 at medium fields and a maximum field of ~18 MV/m.

43 PARTICLE ACCELERATORS↗

Study of Fluctuations in Undulator Radiation in the IOTA Ring at Fermilab

We study turn-by-turn fluctuations in the number of emitted photons in an undulator, installed in the IOTA electron storage ring at Fermilab with an InGaAs PIN photodiode and an integrating circuit. Our study was motivated by the previous experiment *. We propose a theoretical model for the experimental data from * and in our own experiment we attempted to verify the model in an independent and more systematic way. Moreover, these fluctuations are an interesting subject for a study by itself, since they act as a seed for SASE in FELs. We improve the precision of the measurements from * by subtracting the average signal amplitude using a comb filter with a one-turn IOTA delay, and by using a special algorithm for noise subtraction. We obtain a reasonable agreement between our theoretical model and experiment. Along with repeating the experiment from *, which was performed at a constant beam current, we also collect data for fluctuations in undulator light at different beam current values. Lastly, in our experiment we were able to see the transition from Poisson statistics to Super-Poisson statistics for undulator light, whereas in * only the latter statistics was observed.

43 PARTICLE ACCELERATORS↗

FLUKA-MARS15 simulations to optimize the Fermilab PIP-II movable beam absorber

PIP-II is the Fermilab's flagship project to provide powerful, high-intensity proton beams to the laboratory's experiments. The heart of the PIP-II project is an H- 800 MeV superconducting linear accelerator. In order to commission the beam and operate safely the linac, several constraints were evaluated. The design of a movable 5 kW beam absorber was finalized to allow staged beam commissioning in different linac locations. Prompt and residual radiation levels were calculated, and radiation shields were optimized to keep those values within the acceptable levels in the areas surrounding beam absorber. Monte Carlo calculations with FLUKA and MARS15 codes are presented in the paper to support these studies.

43 PARTICLE ACCELERATORS↗

Fermilab Superconducting Nb₃Sn High Field Magnet R&D Program

Magnets based on the modern Nb₃Sn conductor are the main candidates for future high-energy hadron colliders. Fermilab as part of the U.S. MDP executes an extensive R&D program on these high-field magnets. This program includes basic conductor and material R&D, quench per-formance studies, and building a meter-long high-field demonstrator. This paper summarizes the current status of the program including its recent results.

43 PARTICLE ACCELERATORS↗

Statistical Measurement of Longitudinal Beam Halo in Fermilab Recycler

The formation of non-Gaussian halo in both the transverse and longitudinal dimensions of beam bunches has been notoriously difficult both the model and to measure. We present a technique to measure the longitudinal halo of 2.5 MHz bunches in the Fermilab Recycler, which have been formed for the g-2 anomalous magnetic moment experiment. While out of time beam is not a particular concern to this experiment, it is a key issue for the subsequent Mu2e rare muon decay experiment, which will use the same bunch formation procedure. Our measurement relies on a statistical technique, in which a small fraction of the beam is scattered from the primary collimation foil in the recycler, and then is detected by a charge telescope consisting of quartz Cherenkov radiators and photomultiplier tubes. By integrating over many revolutions, the time profile of longitudinal halo (out-of-time beam) can be measured down to less than a 10⁻⁵ fractional level, relative to in-time beam. These results can then be compared to simulations.

43 PARTICLE ACCELERATORS↗