Search NASA⌕ Search

SEARCH · Search NASA

Results for “Focal plane array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

The 12x32 Pop-Up Bolometer Array for the SHARC II Camera

SHARC II is a 350 micron facility camera for the Caltech Submillimeter Observatory (CSO) expected to come on-line in 2002. The key component of SHARC II is a 12x32 array of doped silicon 'pop-up' bolometers developed at NASA/Goddard and delivered to Caltech in March 2002. Each pixel is 1 mm x 1 mm, coated with a 400 Omega/square bismuth film, and located lambda/4 above a reflective backshort to maximize radiation absorption. The pixels cover the focal plane with greater than 95% filling factor. Each doped thermistor occupies nearly the full area of the pixel to minimize 1/f noise. We report some results from the first cold measurements of this array. The bolometers were located inside a dark cover, and 4x32 pixels were read simultaneously. In the best 25% of winter nights on Mauna Kea, SHARC II is expected to have an NEFD at 350 microns of 1 Jy s(sup 1/2) or better.

Dowell, C. Darren↗

Infrared Astronomical Satellite

The objective of the Infrared Astronomical Satellite is to produce an unbiased all-sky survey in the wavelength region between 8 and 120 microns. Using a 60 cm diameter helium cooled telescope and detector arrays which are essentially zodiacal light background photon noise limited, heretofore unprecedented sensitivity can be achieved. The optical design, the focal plane layout and expected performance of the current design concept are discussed.

Aumann, H. H.↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.

Garmire, G. P.↗

Vision-based planetary rover navigation

NASA and JPL have developed a testbed 'planetary rover' vehicle with sufficient power supplies, sensors, and computational resources for the demonstration of semiautonomous navigation. Attention is presently given to this vehicle's vision-based navigation techniques. The proposed design and its variants allow advantage to be taken of enormous quantities of both spatial and temporal information that are normally wasted, by sampling very fine detail over the full focal plane area to precisely determine those parts of the image that are accurately at the focus range of the pinhole array used. This should generate accurate and reliable real-time range information in a wide variety of natural scenes, with little or no computation.

Wilcox, Brian H.↗

Subsystem Imaging Performance and Modeling of the Infrared Multi-Object Spectrograph

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter). IRMOS is a near-IR (0.8 - 2.5 micron) spectrograph with low to mid resolution (R=lambda/delta, lambda = 300 - 3800). The IRMOS spectrograph produces simultaneous spectra of - 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial MEMS multi-mirror array device (MMA). The IRMOS optical design consists of two imaging systems, or "stages." The focal reducer, stage one, images the focal plane of the telescope onto the MMA. The spectrograph, stage two, images the MMA onto the detector. We describe the breadboard alignment method and imaging and scattered light performance for both the focal reducer and spectrograph. This testing provides verification of the optomechanical alignment method, and a measurement of the contribution of scattered light in the system due to mirror small scale surface error. After the stage I and 2 optics are integrated with the instrument, our test results will make it possible to distinguish between scattered light from the mirrors and the MMA. Image testing will be done at four wavelengths in the visible and near-IR. A mercury-argon pencil lamp will provide spectral lines at 546.1 and 1012 nm, and a blackbody radiation source lines at 1600 and 2200 nm. A CCD camera will be used as a detector for the visible wavelengths, and an IR photodiode will be used for the IR wavelengths. We compare our data with a theoretical analysis using a commercial software package. Mirror surface error is modeled by treating each surface as a superposition of various gratings (e.g., diamond turning tool marks, features due to the impurities of Al 6061, and periodic mid-frequency errors due to drift during machining).

Connelly, Joseph A.↗

Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

Achromatic↗

Lead sulfide - Silicon MOSFET infrared focal plane development

A process for directly integrating photoconductive lead sulfide (PbS) infrared detector material with silicon MOS integrated circuits has been developed primarily for application in long (greater than 10,000 detector elements) linear arrays for pushbroom scanning applications. The processing technology is based on the conventional PMOS and CMOS technologies with a variation in the metallization. Results and measurements on a fully integrated eight-element multiplexer are shown.

Barrett, J. R.↗

Further development of an indium antimonide (InSb)Charge-Coupled Infrared Imaging Device (CCIRID), 20-element linear imager

Problems encountered in the development of an indium antimonide charge coupled device for infrared imaging and real time signal processing on the focal plane are summarized. A new generation chip is described which contains, 2, 4, and 20-element imagers, a 4-element TDI array, a monolithic gated charge integrator, and test devices. A system study of a future LANDSAT sensor system configured around an InSb TDi array is considered.

Source record↗

X-ray spectrograph design

An aberration theory is applied to spectrograph design. The initial system considered has a toroidal mirror in front of a concave grating spectrograph, giving spatial resolution perpendicular to the dispersion direction. The accuracy of the theory is shown by comparison of spot diagrams obtained from the aberrations with those produced by raytracing. The major aberrations affecting the vignetting at the intermediate slit and the spatial resolution are identified. A new system, using a holographic grating to give a flat focal plane, is then designed and optimized. It has increased spatial resolution over the wavelength range and is particularly suitable for microchannel array detectors.

Chrisp, M. P.↗

Development of a Transition-Edge Sensor Anti-Coincidence Detector for a Probe Class Mission

The Light Element Mapper (LEM), a probe class mission proposal slated for submission in 2023, combines a large X-ray optic with an extremely large format microcalorimeter array to probe the physics of galaxy formation with a grasp 22x greater than ATHENA and 7x greater than Lynx. The focal plane for LEM requires a larger anti-coincidence detector than the other missions while maintaining or exceeding their high-speed response, presenting a challenge for claiming technical readiness at the time of the announcement of opportunity (AO). We will perform a rapid demonstration in the next year including design, fabrication and integration and test of a high-fidelity transition-edge sensor (TES) based device at a scale suitable for LEM.

James Chervenak↗

Surface relief structures for multiple beam LO generation

Linear and binary holograms for use in heterodyne detection with 10.6 micron imaging arrays are described. The devices match the amplitude and phase of the local oscillator to the received signal and thus maximize the system signal to noise ratio and resolution and minimize heat generation on the focal plane. In both the linear and binary approaches, the holographic surface-relief pattern is coded to generate a set of local oscillator beams when the relief pattern is illuminated by a single planewave. Each beam of this set has the same amplitude shape distribution as, and is collinear with, each single element wavefront illuminating array.

Veldkamp, W. B.↗

Integrating indium antimonide linear arrays at 65K and below

A schematic is presented of a simplified electronic architecture of experimental 128 element infrared imager. Tables are given of sample diode responsivity, 512 element focal plane performance summary, and 128 element FPA mechanical and electrical characteristics. Typical 43 x 43 micron detector IV characteristics at 84 K are given, along with typical 43 x 43 micron Indium Antimonide CV characteristic at 83 K.

Bailey, Gary C.↗

Monolithic short wave infrared (SWIR) detector array

A monolithic self-scanned linear detector array was developed for remote sensing in the 1.1- 2.4-micron spectral region. A high-density IRCCD test chip was fabricated to verify new design approaches required for the detector array. The driving factors in the Schottky barrier IRCCD (Pdsub2Si) process development are the attainment of detector yield, uniformity, adequate quantum efficiency, and lowest possible dark current consistent with radiometric accuracy. A dual-band module was designed that consists of two linear detector arrays. The sensor architecture places the floating diffusion output structure in the middle of the chip, away from the butt edges. A focal plane package was conceptualized and includes a polycrystalline silicon substrate carrying a two-layer, thick-film interconnecting conductor pattern and five epoxy-mounted modules. A polycrystalline silicon cover encloses the modules and bond wires, and serves as a radiation and EMI shield, thermal conductor, and contamination seal.

Source record↗

A new high-speed IR camera system

A multi-organizational team at the Goddard Space Flight Center is developing a new far infrared (FIR) camera system which furthers the state of the art for this type of instrument by the incorporating recent advances in several technological disciplines. All aspects of the camera system are optimized for operation at the high data rates required for astronomical observations in the far infrared. The instrument is built around a Blocked Impurity Band (BIB) detector array which exhibits responsivity over a broad wavelength band and which is capable of operating at 1000 frames/sec, and consists of a focal plane dewar, a compact camera head electronics package, and a Digital Signal Processor (DSP)-based data system residing in a standard 486 personal computer. In this paper we discuss the overall system architecture, the focal plane dewar, and advanced features and design considerations for the electronics. This system, or one derived from it, may prove useful for many commercial and/or industrial infrared imaging or spectroscopic applications, including thermal machine vision for robotic manufacturing, photographic observation of short-duration thermal events such as combustion or chemical reactions, and high-resolution surveillance imaging.

Travis, Jeffrey W.↗

Improved charge injection device and a focal plane interface electronics board for stellar tracking

An improved Charge Injection Device (CID) stellar tracking sensor and an operating sensor in a control/readout electronics board were developed. The sensor consists of a shift register scanned, 256x256 CID array organized for readout of 4x4 subarrays. The 4x4 subarrays can be positioned anywhere within the 256x256 array with a 2 pixel resolution. This allows continuous tracking of a number of stars simultaneously since nine pixels (3x3) centered on any star can always be read out. Organization and operation of this sensor and the improvements in design and semiconductor processing are described. A hermetic package incorporating an internal thermoelectric cooler assembled using low temperature solders was developed. The electronics board, which contains the sensor drivers, amplifiers, sample hold circuits, multiplexer, analog to digital converter, and the sensor temperature control circuits, is also described. Packaged sensors were evaluated for readout efficiency, spectral quantum efficiency, temporal noise, fixed pattern noise, and dark current. Eight sensors along with two tracker electronics boards were completed, evaluated, and delivered.

Michon, G. J.↗

Development of Cryogenic Filter Wheels for the HERSCHEL Photodetector Array Camera & Spectrometer (PACS)

This paper describes the two PACS Filter Wheels that are direct-drive rotational mechanisms operated at a temperature below 5K inside the PACS focal plane unit of the Herschel Satellite. The purpose of the mechanisms is to switch between filters. The rotation axis is pivoted to the support structure via a slightly preloaded pair of ball bearings and driven by a Cryotorquer. Position sensing is realized by a pair of Hall effect sensors. Powerless positioning at the filter positions is achieved by a magnetic ratchet system. The key technologies are the Cryotorquer design and the magnetic ratchet design in the low temperature range. Furthermore, we will report on lessons learned during the development and qualification of the mechanism and the paint.

Koerner, Christian↗

Array-fed reflector antenna design and applications

One phase of the spacecraft antenna research carried out at the Jet Propulsion Laboratory for deep space and near-earth communications is described. Array-fed reflector antenna designs have been elaborated for beam scanning, power amplification, and multiple beam applications. The antenna designs derive from similar optical concepts. Each antenna comprises a relatively small plane-wave array feeding a near-field dual-reflector system. The main reflector and the the subreflector are confocal paraboloids having identical focal length to diameter ratios. The array feed is positioned in such a way that the subreflector is in the near-field (collimated beam) region of the feed. The field distribution of the feed aperture is thereby recreated approximately in the main reflector aperture. The detailed design concepts of the antennas (beam-scanning, high-power, and mutliple-beam) are discussed, and the calculated and measured RF performances of the antennas are presented.

Woo, K.↗

The HYDICE instrument design and its application to planetary instruments

The Hyperspectral Digital Imagery Collection Experiment (HYDICE) instrument represents a significant advance in the state of the art in hyperspectral sensors. It combines a higher signal-to-noise ratio (SNR) and significantly better spatial and spectral resolution and radio metric accuracy than systems flying on aircraft today. The need for 'clean' data, i.e., data free of sampling artifacts and excessive spatial or spectral noise, is a key driver behind the difficult combination of performance requirements laid out for HYDICE. Most of these involve the sensor optics and detector. This paper presents an optimized approach to those requirements, one that comprises push broom scanning, a single, mechanically cooled focal plane, a double-pass prism spectrometer, and an easily fabricated yet wide-field telescope. Central to the approach is a detector array that covers the entire spectrum from 0.4 to 2.5 microns. Among the major benefits conferred by such a design are optical and mechanical simplicity, low polarization sensitivity, and coverage of the entire spectrum without suffering the spectral gaps caused by beam splitters. The overall system minimizes interfaces to the C-141 aircraft on which it will be flown, can be calibrated on the ground and in flight to accuracies better than those required, and is designed for simple, push-button operation. Only unprocessed data are recorded during flight. A ground data processing station provides quick-look, calibration correction, and archiving capabilities, with a throughput better than the requirements. Overall performance of the system is expected to provide the solid database required to evaluate the potential of hyperspectral imagery in a wide variety of applications. HYDICE can be regarded as a test bed for future planetary instruments. The ability to spectrally image a wide field of view over multiple spectral octaves offers obvious advantages and is expected to maximize science return for the required cost and weight.

Basedow, R.↗