Search NASA⌕ Search

SEARCH · Search NASA

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

The Role of Radiation Therapy in Patients With Relapsed or Refractory Hodgkin Lymphoma: Guidelines From the International Lymphoma Radiation Oncology Group

Relapsed and refractory Hodgkin lymphoma (HL) challenges clinicians to devise treatment strategies that are effective and safe. This problem is particularly prominent in an era when de-escalation trials are designed to minimize therapeutic toxicities in both early- and advanced-stage disease. Radiation therapy is the single most effective treatment modality for HL, and its integration into salvage regimens, or its independent use in select patients, must be understood to maximize our success in treating these patients. The complexity of treating relapsed or refractory HL derives from the spectrum of primary treatment approaches currently in use that creates heterogeneity in both treatment exposure and the potential toxicities of salvage therapy. Patients can have relapsed or refractory disease after limited or aggressive primary therapy (with or without radiation therapy), at early or delayed time points, with limited or extensive disease volumes, and with varying degrees of residual morbidity from primary therapy. Their response to salvage systemic therapy can be partial or complete, and the use of consolidative stem cell transplantation is variably applied. New biologics and immunotherapeutic approaches have broadened but also complicated salvage treatment approaches. Through all of this, radiation therapy remains an integral component of treatment for many patients, but it must be used effectively and judiciously. The purpose of this review is to describe the different treatment scenarios and provide guidance for radiation dose, volume, and timing in patients with relapsed or refractory HL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Executive Summary of the American Radium Society Appropriate Use Criteria for Operable Esophageal and Gastroesophageal Junction Adenocarcinoma: Systematic Review and Guidelines

Limited guidance exists regarding the relative effectiveness of treatment options for nonmetastatic, operable patients with adenocarcinoma of the esophagus or gastroesophageal junction (GEJ). In this systematic review, the American Radium Society (ARS) gastrointestinal expert panel convened to develop Appropriate Use Criteria (AUC) evaluating how neoadjuvant and/or adjuvant treatment regimens compared with each other, surgery alone, or definitive chemoradiation in terms of response to therapy, quality of life, and oncologic outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NRG Oncology/RTOG Consensus Guidelines for Delineation of Clinical Target Volume for Intensity Modulated Pelvic Radiation Therapy in Postoperative Treatment of Endometrial and Cervical Cancer: An Update

Accurate target definition is critical for the appropriate application of radiation therapy. In 2008, the Radiation Therapy Oncology Group (RTOG) published an international collaborative atlas to define the clinical target volume (CTV) for intensity modulated pelvic radiation therapy in the postoperative treatment of endometrial and cervical cancer. The current project is an updated consensus of CTV definitions, with removal of all references to bony landmarks and inclusion of the para-aortic and inferior obturator nodal regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiosurgery for Postoperative Metastatic Surgical Cavities: A Critical Review and International Stereotactic Radiosurgery Society (ISRS) Practice Guidelines

The purpose of this critical review is to summarize the literature specific to single-fraction stereotactic radiosurgery (SRS) and multiple-fraction stereotactic radiation therapy (SRT) for postoperative brain metastases resection cavities and to present practice recommendations on behalf of the ISRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validating Modern NRG Oncology Pelvic Nodal and Groupe Francophone de Radiothérapie Urologique Prostate Bed Contouring Guidelines for Post-Prostatectomy Salvage Radiation: A Secondary Analysis of the LOCATE Trial

We used the patterns of recurrence on {sup 18}F-fluciclovine positron emission tomography (PET)–computed tomography (CT) in patients enrolled in the LOCATE trial after prostatectomy to evaluate how well the most recent NRG Oncology and Groupe Francophone de Radiothérapie Urologique (GFRU) contouring recommendations encompassed all sites of recurrence in the prostate fossa and pelvic nodes in comparison to former Radiation Therapy Oncology Group (RTOG) recommendations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of modified dynamic conformal arc (MDCA) technique on liver stereotactic body radiation therapy (SBRT) planning following RTOG 0438 guideline

Liver stereotactic body radiation therapy (SBRT) is a feasible treatment method for the nonoperable, patient with early-stage liver cancer. Treatment planning for the SBRT is very important and has to consider the simulation accuracy, planning time, treatment efficiency effects etc. The modified dynamic conformal arc (MDCA) technique is a 3-dimensional conformal arc planning method, which has been proposed for liver SBRT planning at our center. In this study, we compared the MDCA technique with the RapidArc technique in terms of planning target volume (PTV) coverage and sparing of organs at risk (OARs). The results show that the MDCA technique has comparable plan quality to RapidArc considering PTV coverage, hot spots, heterogeneity index, and effective liver volume. For the 5 PTVs studied among 4 patients, the MDCA plan, when compared with the RapidArc plan, showed 9% more hot spots, more heterogeneity effect, more sparing of OARs, and lower liver effective volume. The monitor unit (MU) number for the MDCA plan is much lower than for the RapidArc plans. The MDCA plan has the advantages of less planning time, no-collision treatment, and a lower MU number.

61 RADIATION PROTECTION AND DOSIMETRY↗

Unlocking multiphysics design guidelines on Si/C composite nanostructures for high-energy-density and robust lithium-ion battery anode

In general, current material fabrication guidance for novel designs of Si/C composite particle materials focuses on electrochemical behavior and redox reactions at the nano/micro level. However, such guidance cannot provide detailed information for predicting mechanical deformations of the composite particles, especially when the mechanical field coupled with electrochemical and thermal fields. Here, we establish an electro-chemo-mechanical model and implement it to quantitatively analyze the multiphysics behavior of five representative Si/C composite nanostructures. Modeling and computation discover that yolk-shell and dual-shell structures are more robust in terms of particle fractures. When considering electrochemical performance, the yolk-shell structure is the best among the compared five Si/C composites. Finally, we map design guidance to further illustrate quantitative structure-property relationships. This study provides novel insights on Si/C composite nanostructure anode material design and additional powerful design tools for next-generation high-energy-density lithium-ion batteries.

25 ENERGY STORAGE↗

Guidelines for Phase Change Material Selection Based on a Holistic System Model

Concentrating solar power (CSP) has potential to increase the amount of renewable energy on electric grids and reduce global carbon emissions, in particular because of its capability to incorporate inexpensive thermal energy storage. To realize this potential, development of latent heat storage with phase change materials (PCMs) is attractive because of its high energy density and low material cost. Research in this area has identified many promising materials, and has developed effective storage system designs that could be used to deploy PCMs. However, the field has lacked a rigorous methodology to select the optimal material for a particular CSP system. To address this need, here we present a holistic model that evaluates all important influences of PCM properties on the performance and cost of an entire CSP plant. We apply this model to over 100 of the most widely considered candidate materials, including both salts and metals. We quantify the relative value of each PCM property, and identify leading materials for application in CSP systems. This method and our results may aid future efforts to develop latent heat storage by providing a more informed view of how material selection impacts an entire CSP system.

14 SOLAR ENERGY↗

Guidelines for Synthesis and Processing of Two-Dimensional [2D] Titanium Carbide (Ti 3 C 2 T x MXene)

Two-dimensional (2D) transition metal carbides, carbonitrides, and nitrides (MXenes) were discovered in 2011. Since the original discovery, more than 20 different compositions have been synthesized by the selective etching of MAX phase and other precursors and many more theoretically predicted. They offer a variety of different properties, making the family promising candidates in a wide range of applications, such as energy storage, electromagnetic interference shielding, water purification, electrocatalysis, and medicine. These solution-processable materials have the potential to be highly scalable, deposited by spin, spray, or dip coating, painted or printed, or fabricated in a variety of ways. Due to this promise, the amount of research on MXenes has been increasing, and methods of synthesis and processing are expanding quickly. The fast evolution of the material can also be noticed in the wide range of synthesis and processing protocols that determine the yield of delamination, as well as the quality of the 2D flakes produced. Furthermore we describe the experimental methods and best practices we use to synthesize the most studied MXene, titanium carbide (Ti 3 C 2 T x ), using different etchants and delamination methods. We also explain effects of synthesis parameters on the size and quality of Ti 3 C 2 T x and suggest the optimal processes for the desired application.

36 MATERIALS SCIENCE↗