Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Lignin-derived electrochemical energy materials and systems

Electrochemical energy storage systems such as supercapacitors, rechargeable batteries and fuel cells have been proven the most effective technologies for energy conversion, storage, and management at different scales. Although a large number of electrochemical energy technologies have been developed in the past and they will continue to be optimized in terms of cost, lifetime, and performance, there is a substantial growing demand for advanced electrochemical energy systems. To deploy these advanced systems, the electrode and electrolyte materials with higher performance, longer life, and lower cost, must be developed. Lignin is the second most abundant natural polymer after cellulose, a byproduct from emerging cellulosic biorefineries, and a waste product from pulp and paper industries. Numerous researches have successfully demonstrated that lignin from different sources can be used as precursors or feedstocks for preparing high-performance electrochemical energy materials and components such as electrodes, electrolytes, membrane separators, and additives. Moreover, techno-economic analyses indicate that it is possible to prepare cost-effective carbons from lignin at engineering scales, compared to current carbon products. These facts suggest that scalable conversion of lignin into high-value energy materials will offer a promising pathway to not only promote the utilization and valorization of lignin but also boost the development of the advanced electrochemical energy systems. This review presents state of the arts of renewable energy materials derived from various lignin and their applications in electrochemical energy systems with emphasis on supercapacitors, rechargeable batteries, and fuel cells. Meanwhile, this article also aims to carve out the critical barriers for lignin-derived high-performance materials for energy applications, intending to identify viable approaches for synthesis of sustainable new energy materials.

09 BIOMASS FUELS↗

Nuclear Energy Advanced Modeling and Simulation (NEAMS) waste Integrated Performance and Safety Codes (IPSC) : gap analysis for high fidelity and performance assessment code development.

This report describes a gap analysis performed in the process of developing the Waste Integrated Performance and Safety Codes (IPSC) in support of the U.S. Department of Energy (DOE) Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Campaign. The goal of the Waste IPSC is to develop an integrated suite of computational modeling and simulation capabilities to quantitatively assess the long-term performance of waste forms in the engineered and geologic environments of a radioactive waste storage or disposal system. The Waste IPSC will provide this simulation capability (1) for a range of disposal concepts, waste form types, engineered repository designs, and geologic settings, (2) for a range of time scales and distances, (3) with appropriate consideration of the inherent uncertainties, and (4) in accordance with rigorous verification, validation, and software quality requirements. The gap analyses documented in this report were are performed during an initial gap analysis to identify candidate codes and tools to support the development and integration of the Waste IPSC, and during follow-on activities that delved into more detailed assessments of the various codes that were acquired, studied, and tested. The current Waste IPSC strategy is to acquire and integrate the necessary Waste IPSC capabilities wherever feasible, and develop only those capabilities that cannot be acquired or suitably integrated, verified, or validated. The gap analysis indicates that significant capabilities may already exist in the existing THC codes although there is no single code able to fully account for all physical and chemical processes involved in a waste disposal system. Large gaps exist in modeling chemical processes and their couplings with other processes. The coupling of chemical processes with flow transport and mechanical deformation remains challenging. The data for extreme environments (e.g., for elevated temperature and high ionic strength media) that are needed for repository modeling are severely lacking. In addition, most of existing reactive transport codes were developed for non-radioactive contaminants, and they need to be adapted to account for radionuclide decay and in-growth. The accessibility to the source codes is generally limited. Because the problems of interest for the Waste IPSC are likely to result in relatively large computational models, a compact memory-usage footprint and a fast/robust solution procedure will be needed. A robust massively parallel processing (MPP) capability will also be required to provide reasonable turnaround times on the analyses that will be performed with the code. A performance assessment (PA) calculation for a waste disposal system generally requires a large number (hundreds to thousands) of model simulations to quantify the effect of model parameter uncertainties on the predicted repository performance. A set of codes for a PA calculation must be sufficiently robust and fast in terms of code execution. A PA system as a whole must be able to provide multiple alternative models for a specific set of physical/chemical processes, so that the users can choose various levels of modeling complexity based on their modeling needs. This requires PA codes, preferably, to be highly modularized. Most of the existing codes have difficulties meeting these requirements. Based on the gap analysis results, we have made the following recommendations for the code selection and code development for the NEAMS waste IPSC: (1) build fully coupled high-fidelity THCMBR codes using the existing SIERRA codes (e.g., ARIA and ADAGIO) and platform, (2) use DAKOTA to build an enhanced performance assessment system (EPAS), and build a modular code architecture and key code modules for performance assessments. The key chemical calculation modules will be built by expanding the existing CANTERA capabilities as well as by extracting useful components from other existing codes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of an Integrated Gasification Direct-Fired Supercritical CO2 Power Cycle

This presentation discusses development and performance results of a coal gasification system integrated with a direct-fired supercritical CO2 (sCO2) power cycle. In this plant, coal is first gasified and cleaned in order to avoid introducing sulfur and particulate matter into the sCO2 cycle, with the sCO2 cycle’s oxy-combustor burning the cleaned syngas with oxygen in a recycled sCO2 stream. The plant is inherently amenable to carbon capture and storage (CCS) processes, as it produces a high pressure exhaust stream that is largely comprised of CO2. The baseline direct sCO2 cycle performance is discussed and compared to IGCC and oxy-coal AUSC reference plants with CCS. The sensitivity of the sCO2 cycle’s performance to various operating parameters is also discussed, as well as the effect of various heat integration options on thermal efficiency, operability, and cost.

Shelton, Walter↗

Reversible Crosslinked Polymer Binder for Recyclable Lithium Sulfur Batteries with High Performance

Owing to the negative impact of the extensive utilization of batteries on the environment, sustainability of the cells needs to be included in the systemic research of batteries. In this work, a dissolvable ionic crosslinked polymer (DICP) is exploited as a binder for lithium–sulfur batteries by crosslinking the polyacrylic acid and polyethyleneimine through carboxy-amino ionic interaction. This interaction is pH-controlled, and therefore, the crosslinked binder network can be readily dissociated under basic conditions, providing a facile strategy enabling valuable components recycled through a convenient washing method. The sulfur cathode prepared using the recycled carbon–sulfur composite can deliver comparable capacity as that of fresh electrode. In addition, evidence from cell performance and characterizations, such as in situ X-ray absorption spectroscopy, in situ UV–visible spectroscopy, X-ray photoelectron spectroscopy, and density functional theory calculation, confirms that DICP is a more effective binder than its commercial counterpart on suppressing polysulfide dissolution in the electrolyte. Exploiting reversible crosslinked polymer binder for recyclable Li–S batteries with ameliorated electrochemical performance, this study illuminates sustainable development for large-scale energy storage systems.

36 MATERIALS SCIENCE↗

Performance and Durability of Proton Exchange Membrane Vapor-Fed Unitized Regenerative Fuel Cells

With a growing demand for electricity, clean hydrogen production and usage can be an asset not only to mitigate emissions but for long-term energy storage as well. Hydrogen gas, a high-density energy carrier, can be made through electrolysis in charging mode and generate electricity via a fuel cell in discharging mode in a unitized regenerative fuel cell (URFC). While URFCs reduce cost by combining the charging and discharging modes into a singular device, switching between modes becomes burdensome, and water management is a major challenge. One way to mitigate these issues is to operate the entire system in the vapor phase. Vapor-phase operation simplifies the physics of the system but will introduce losses within the system, primarily ohmic and mass transport during the charging mode. In this study, we explore the performance of a Proton-Exchange-Membrane (PEM)-URFC under vapor-phase conditions and the impact of different PEMs, feed gases, and relative humidity on the performance and durability. By tailoring operating conditions and membrane, the vapor-URFC achieves a roundtrip efficiency of 42% and a lifetime of 50,000 accelerated stress test cycles for fully humidified feeds. Discussion of vapor-URFC for energy storage and extensions to look at various applications shows the promise of this technology.

25 ENERGY STORAGE↗

Foresee: A user-centric home energy management system for energy efficiency and demand response

This paper presents foresee, a user-centric home energy management system that can help optimize how a home operates to concurrently meet users' needs, achieve energy efficiency and commensurate utility cost savings, and reliably deliver grid services based on utility signals. Foresee is built on a multiobjective model predictive control framework, wherein the objectives consist of energy cost, thermal comfort, user convenience, and carbon emission. Foresee learns user preferences on different objectives and acts on their behalf to operate building equipment, such as home appliances, photovoltaic systems, and battery storage. In this work, machine-learning algorithms were used to derive data-driven appliance models and usage patterns to predict the home's future energy consumption. This approach enables highly accurate predictions of comfort needs, energy costs, environmental impacts, and grid service availability. Simulation studies were performed on field data from a residential building stock data set collected in the Pacific Northwest. Results indicated that foresee generated up to 7.6% whole-home energy savings without requiring substantial behavioral changes. When responding to demand response events, foresee was able to provide load forecasts upon receipt of event notifications and delivered the committed demand response services with 10% or fewer errors. Foresee fully utilized the potential of the battery storage and controllable building loads and delivered up to 7.0-kW load reduction and 13.5-kW load increase. As a result, these benefits are provided while maintaining the occupants' thermal comfort or convenience in using their appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IN-SERVICE INSPECTION OF EXTENDED DRY STORAGE OF SPENT NUCLEAR FUEL, PART I: CRAWLER TECHNOLOGY DEVELOPMENT

This paper describes development and demonstration of remote crawling systems to support periodic examinations of interim dry storage system (DSS) canisters for spent nuclear fuel in the USA. Specifically, this work relates to robotic crawler developments for “canister” based DSS systems which form the majority population of DSSs, in the USA, for interim storage of spent nuclear fuel. Consideration of potential degradation of the welded stainless-steel canister in these systems is required for continued usage in the period of extended operation (PEO) beyond their initial licensed or certified terms. Challenges associated with performing the periodic examinations are associated with physical access to the canister surface which is constrained due to narrow annulus spaces between the canister and the overpack, tortuous entry pathways, and high temperatures and radiation doses that can be damaging to materials and electronics. Motivations for performing periodic examinations and developing robotic crawlers for performing those examinations remotely will be presented and several activities to demonstrate robotic crawlers for different DSS systems are summarized.

nondestructive examination (NDE), Dry Cask Storage↗

Failing in place for low-serviceability storage infrastructure using high-parity GPU-based RAID.

In order to provide large quantities of high-reliability disk-based storage, it has become necessary to aggregate disks into fault-tolerant groups based on the RAID methodology. Most RAID levels do provide some fault tolerance, but there are certain classes of applications that require increased levels of fault tolerance within an array. Some of these applications include embedded systems in harsh environments that have a low level of serviceability, or uninhabited data centers servicing cloud computing. When describing RAID reliability, the Mean Time To Data Loss (MTTDL) calculations will often assume that the time to replace a failed disk is relatively low, or even negligible compared to rebuild time. For platforms that are in remote areas collecting and processing data, it may be impossible to access the system to perform system maintenance for long periods. A disk may fail early in a platform's life, but not be replaceable for much longer than typical for RAID arrays. Service periods may be scheduled at intervals on the order of months, or the platform may not be serviced until the end of a mission in progress. Further, this platform may be subject to extreme conditions that can accelerate wear and tear on a disk, requiring even more protection from failures. We have created a high parity RAID implementation that uses a Graphics Processing Unit (GPU) to compute more than two blocks of parity information per stripe, allowing extra parity to eliminate or reduce the requirement for rebuilding data between service periods. While this type of controller is highly effective for RAID 6 systems, an important benefit is the ability to incorporate more parity into a RAID storage system. Such RAID levels, as yet unnamed, can tolerate the failure of three or more disks (depending on configuration) without data loss. While this RAID system certainly has applications in embedded systems running applications in the field, similar benefits can be obtained for servers that are engineered for storage density, with less regard for serviceability or maintainability. A storage brick can be designed to have a MTTDL that extends well beyond the useful lifetime of the hardware used, allowing the disk subsystem to require less service throughout the lifetime of a compute resource. This approach is similar to the Xiotech ISE. Such a design can be deliberately placed remotely (without frequent support) in order to provide colocation, or meet cost goals. For workloads where reliability is key, but conditions are sub-optimal for routine serviceability, a high-parity RAID can provide extra reliability in extraordinary situations. For example, for installations requiring very high Mean Time To Repair, the extra parity can eliminate certain problems with maintaining hot spares, increasing overall reliability. Furthermore, in situations where disk reliability is reduced because of harsh conditions, extra parity can guard against early data loss due to lowered Mean Time To Failure. If used through an iSCSI interface with a streaming workload, it is possible to gain all of these benefits without impacting performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gasification of Coal and Biomass: The Route to Net-Negative-Carbon Power and Hydrogen

One promising process that is a candidate for meeting the goals of the US Department of Energy’s 21st Century Power Plant initiative is to gasify a mixture of coal and biomass to yield a syngas, which can have CO2 removed and then be used to produce hydrogen as well as an off-gas that can be used to flexibly produce power. This concept would overall be carbon net-negative and readily meet the 21st Century Power Plant initiative targets of smaller scale MW generation, high ramp rates and turndown, feedstock flexibility, and high efficiency—at a reasonable cost. Moreover, adding the large-scale production of “ultra-green” hydrogen yields a system tailored for the coming hydrogen economy, providing long-term energy storage and an attractive co-product for sale. The objective of the work being led by the Electric Power Research Institute, Inc. (EPRI), with support by Bechtel Corporation (Bechtel), Gas Technology Institute (GTI), Hamilton Mauer International, Inc. (HMI), Nebraska Public Power District (NPPD), NexantECA, Inc. (Nexant), and Wärtsilä, is to perform a front-end design and engineering (FEED) study on an oxygen-blown gasification system coupled with water-gas shift, pre-combustion CO2 capture, and pressure-swing adsorption working off a coal/biomass mix to yield high-purity hydrogen and a fuel off-gas that can generate power. Several designs are being considered that will be capable of producing 50 MW net from a flexible generator, over 8500 kg/hr of hydrogen, and net-negative CO2 emissions, at an efficiency of 50% net HHV. The plant would be hosted at an NPPD site, where opportunities for enhanced oil recovery and sequestration have been investigated and the need for low-carbon power and hydrogen is imminent. The principal biomass to be used is corn stover—prevalent in Nebraska where the plant will be located—mixed with Powder River Basin (PRB) coal, necessitating a gasifier that can use this feedstock and be flexible to allow other types. Waste plastics will also be reviewed for use. Two oxygen-blown gasifiers have been identified as candidates that have done testing with biomass including corn stover: the GTI gasifier—a high-pressure, fluidized-bed type—and HMI’s, a lower pressure moving-bed type. Both have relative advantages that were investigated in the Phase I design study, with a resultant down select of one system for which the FEED will be performed in Phase II. The technical tasks for the project are: • Design Development: Completion of design activities necessary to provide inputs for the FEED study. Multiple design cases will be assessed with the selection of the optimal one for the FEED. • Investment Case Preparation: Development of the draft investment case for the proposed process with business cases performed for the proposed host site and two other locations. • Host Site Selection: Evaluation of the two potential host sites within NPPD’s portfolio to select the preferred candidate based on technical, economic, and environmental considerations. • Environmental Information Volume (EIV) Development: Completion of the EIV for the host site. • FEED Study: Completion of a FEED study based on the design selected in Phase I. A Greenhouse Gas Life Cycle Analysis will also be performed for the process. • Update Investment Case: Finalization of the investment case based on findings from the FEED. The advantages of the proposed project are significant. Having an engaged U.S. power utility willing to provide a host site that will produce energy from coal plus a deep and experienced team is critical; the process meets all the goals of DOE’s 21st Century Power Plant initiative at an estimated total plant cost of ~$880M and a production cost of hydrogen of ~$2/kg-H2 while producing net-negative carbon power. If developed, this process has real commercial potential in the United States—supported by EPRI’s initial review of the considerable interest from selected U.S. utilities—and elsewhere around the globe. The process has fewer environmental hurdles compared to other concepts, lowering regulatory and protest risks—providing a pathway to preserving the viability of a critical indigenous energy source by transforming its use to match a changing world. This presentation outlines the motivation for the effort, summarizes project plans, work completed to date, results of the Phase I effort and, and detailed work scope for the remainder of the project in the Phase II FEED effort.

01 COAL, LIGNITE, AND PEAT↗

Building an Integrated Ecosystem of Computational and Observational Facilities to Accelerate Scientific Discovery

Future scientific discoveries will rely on flexible ecosystems that incorporate modern scientific instruments, high performance computing resources, parallel distributed data storage, and performant networks across multiple, independent facilities. In addition to connecting physical resources, such an ecosystem presents many challenges in logistics and accessibility, especially in orchestrating computations and experiments that span across leadership computing systems and experimental instruments. Past efforts have typically been application-specific or limited to interfaces for computing resources. This paper proposes a general framework for integrating computation resources and instrument operations, addressing challenges in code development/execution, data staging and collection, software stack, control mechanisms, resource authorization and governance, and hardware integration. We also describe a demonstration use case wherein a Bayesian optimization algorithm running on an edge computing resource guides a scanning probe microscope to autonomously and intelligently characterize a material sample. This science edge ecosystem framework will provide a blueprint for federating multi-institutional, disparate resources and orchestrating scientific workflows across them to enable next-generation discoveries.

Somnath, Suhas↗

Strong and Efficient Consistency with Consistency-aware Durability

We introduce consistency-aware durability or C ad , a new approach to durability in distributed storage that enables strong consistency while delivering high performance. We demonstrate the efficacy of this approach by designing cross-client monotonic reads , a novel and strong consistency property that provides monotonic reads across failures and sessions in leader-based systems; such a property can be particularly beneficial in geo-distributed and edge-computing scenarios. We build O rca , a modified version of ZooKeeper that implements C ad and cross-client monotonic reads. We experimentally show that O rca provides strong consistency while closely matching the performance of weakly consistent ZooKeeper. Compared to strongly consistent ZooKeeper, O rca provides significantly higher throughput (1.8--3.3×) and notably reduces latency, sometimes by an order of magnitude in geo-distributed settings. We also implement C ad in Redis and show that the performance benefits are similar to that of C ad ’s implementation in ZooKeeper.

Computer Science↗

Biological and Environmental Research Network Requirements

The Energy Sciences Network (ESnet) is the primary provider of network connectivity for the U.S. Department of Energy (DOE) Office of Science (SC), the single largest supporter of basic research in the physical sciences in the United States. In support of SC programs, ESnet regularly updates and refreshes its understanding of the networking requirements of the instruments, facilities, scientists, and science programs that it serves. This focus has helped ESnet be a highly successful enabler of scientific discovery for over 25 years. In November 2012, ESnet and the Office of Biological and Environmental Research (BER) of the DOE SC organized a review to characterize the networking requirements of the programs funded by the BER program office. Several key findings resulted from the review. Among them: 1) The scale of data sets available to science collaborations continues to increase exponentially. This has broad impact, both on the network and on the computational and storage systems connected to the network. 2) Many science collaborations require assistance to cope with the systems and network engineering challenges inherent in managing the rapid growth in data scale. 3) Several science domains operate distributed facilities that rely on high-performance networking for success. Key examples illustrated in this report include the Earth System Grid Federation (ESGF) and the Systems Biology Knowledgebase (KBase). This report expands on these points, and addresses others as well. The report contains a findings section as well as the text of the case studies discussed at the review.

09 BIOMASS FUELS↗

County-level assessment of behind-the-meter solar and storage to mitigate long duration power interruptions for residential customers

Customer concerns over electric system resilience could drive early adoption of behind-the-meter solar-plus-storage (BTM PVESS), especially as wildfire, hurricane, and other climate-driven risks to electric grids become more pronounced. However, the resilience benefits of BTM PVESS are poorly understood, especially for residential customers, owing to lack of data and methodological challenges, making it difficult to forecast adoption trends. In this paper, we develop a methodology to model the performance of BTM PVESS in providing backup power across a wide range of customer types, geography / climate conditions, and long duration power interruption scenarios, considering both whole-building backup and backup of specific critical loads. We combine novel, disaggregated end-use load profiles across the continental United States with temporally and geospatially aligned solar generation estimates. We then implement a PVESS dispatch algorithm to calculate the amount of load served during interruptions. We find that PVESS with 10 kWh of storage can meet a limited set of critical loads in most United States counties during any month of the year, though this capability drops to meeting only 86% of critical load, averaged across all counties and months, when heating and cooling are considered critical. Backup performance is lowest in winter months where electric heat is common (southeast and northwest U.S.) and in summer months in places with large cooling loads (southwest and southeast U.S.). Winter backup performance varies by roughly 20% depending on infiltration rates, while summer performance varies by close to 15% depending on the efficiency of the central air-conditioning system. Differences in temperature set-points in Harris County correspond to a 40% range in winter backup performance and a 20% range in summer performance. Economic calculations show that a customer’s resilience value of PVESS must be high to motivate adoption of these systems.

14 SOLAR ENERGY↗

Reversible redox chemistry in azobenzene-based organic molecules for high-capacity and long-life nonaqueous redox flow batteries

Redox flow batteries (RFBs), often categorized as aqueous and nonaqueous systems, represent a type of large-scale energy storage technology for renewable energy resources. Redox-active organic molecules have recently drawn extensive interests in RFBs as promising active materials due to their elemental abundance, structural diversity and high tunability of properties, but employing organic molecules in nonaqueous systems is far limited in terms of useable capacity and cycling stability. Here we introduce a class of azobenzene-based organic compounds with the azo group as redox-active center in the p-conjugated structure as new active materials to realize high-performance nonaqueous RFBs with long cycling life and high capacity. By screening suitable organic solvents with high solubility and conductivity, the azobenzene organic molecule was capable to achieve a stable long cycling with a low capacity decay of 0.014% per cycle and 0.16% per day over 1000 cycles. And the stable cycling of electrolytes under a high concentration of 1 M was also realized, delivering a high reversible capacity of ~46 Ah L -1 . The unique lithium-coupled redox chemistry accompanied with a voltage increase was observed and revealed by experimental characterization and theoretical simulation. With the reversible two-electron redox activity of azo group in p-conjugated structures, azobenzene as an azo-aromatic molecule represents a class of promising redox-active organics for potential grid-scale energy storage systems.

25 ENERGY STORAGE↗

A Virtualized Computing Platform For Fusion Control Systems

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a stadium-sized facility that contains a 192-beam, 1.8-Megajoule, 500-Terawatt, ultraviolet laser system together with a 10-meter diameter target chamber with room for multiple experimental diagnostics. NIF is the world's largest and most energetic laser experimental system, providing a scientific center to study inertial confinement fusion (ICF) and matter at extreme energy densities and pressures. NIF's laser beams are designed to compress fusion targets to conditions required for thermonuclear burn, liberating more energy than required to initiate the fusion reactions. 2,500 servers, 400 network devices and 700 terabytes of networked attached storage provide the foundation for NIF's Integrated Computer Control System (ICCS) and Experimental Data Archive. This talk discusses the rationale & benefits for server virtualization in the context of an operational experimental facility, the requirements discovery process used by the NIF teams to establish evaluation criteria for virtualization alternatives, the processes and procedures defined to enable virtualization of servers in a timeframe that did not delay the execution of experimental campaigns and the lessons the NIF teams learned along the way. The virtualization architecture ultimately selected for ICCS is based on the Open Source Xen computing platform and 802.1Q open networking standards. The specific server and network configurations needed to ensure performance and high availability of the control system infrastructure will be discussed.

42 ENGINEERING↗

Fabrication of ultrathin solid electrolyte membranes of β-Li 3 PS 4 nanoflakes by evaporation-induced self-assembly for all-solid-state batteries

All-solid-state lithium batteries are attractive candidates for next-generation energy storage devices because of their anticipated high energy density and intrinsic safety. Owing to their excellent ionic conductivity and stability with metallic lithium anodes, nanostructured lithium thiophosphate solid electrolytes such as β-Li 3 PS 4 have found use in the fabrication of all-solid lithium batteries for large-scale energy storage systems. However, current methods for preparing air-sensitive solid electrolyte membranes of lithium thiophosphates can only generate thick membranes that compromise the battery's gravimetric/volumetric energy density and thus its rate performance. To overcome this limitation, the solid electrolyte's thickness needs to be effectively decreased to achieve ideal energy density and enhanced rate performance. In this paper, we show that the evaporation-induced self-assembly (EISA) technique produces ultrathin membranes of a lithium thiophosphate solid electrolyte with controllable thicknesses between 8 and 50 μm while maintaining the high ionic conductivity of β-Li 3 PS 4 and stability with metallic lithium anodes up to 5 V. Finally, it is clearly demonstrated that this facile EISA approach allows for the preparation of ultrathin lithium thiophosphate solid electrolyte membranes for all-solid-state batteries.

25 ENERGY STORAGE↗

Influence of Metal Identity on Light-Induced Switchable Adsorption in Azobenzene-Based Metal–Organic Frameworks

Energy-efficient capture and release of small gas molecules, particularly carbon dioxide (CO 2 ) and methane (CH 4 ), are of significant interest in academia and industry. Porous materials such as metal–organic frameworks (MOFs) have been extensively studied, as their ultrahigh porosities and tunability enable significant amounts of gas to be adsorbed while also allowing specific applications to be targeted. However, because of the microporous nature of MOFs, the gas adsorption performance is dominated by high uptake capacity at low pressures, limiting their application. Hence, methods involving stimuli-responsive materials, particularly light-induced switchable adsorption (LISA), offer a unique alternative to thermal methods. Here, we report the mechanism of a well-known LISA system, the azobenzene-based material PCN-250, for CO 2 and CH 4 adsorption. There is a noticeable difference in the LISA effect dependent on the metal cluster involved, with the most significant being PCN-250-Al, where the adsorption can change by 83.1% CH 4 and 56.1% CO 2 at 298 K and 1 bar and inducing volumetric storage changes of 36.2 and 33.9 cm 3 /cm 3 at 298 K between 5 and 85 bar (CH 4 ) and 2 and 9 bar (CO 2 ), respectively. Using UV light in both single-crystal X-ray diffraction and gas adsorption testing, we show that upon photoirradiation, the framework undergoes a “localized heating” phenomenon comparable to an increase of 130 K for PCN-250-Fe and improves the working capacity. Furthermore, this process functions because of the constrained nature of the ligand, preventing the typical trans-to-cis isomerization observed in free azobenzene. In addition, we observed that the degree of localized heating is highly dependent on the metal cluster involved, with the series of isostructural PCN-250 systems showing variable performance based upon the degree of interaction between the ligand and the metal center.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hvac: Removing I/O Bottleneck for Large-Scale Deep Learning Applications

Scientific communities are increasingly adopting deep learning (DL) models in their applications to accelerate scientific discovery processes. However, with rapid growth in the computing capabilities of HPC supercomputers, large-scale DL applications have to spend a significant portion of training time performing I/O to a parallel storage system. Previous research works have investigated optimization techniques such as prefetching and caching. Unfortunately, there exist non-trivial challenges to adopting the existing solutions on HPC supercomputers for large-scale DL training applications, which include non-performance and/or failures at extreme scale, lack of portability and generality in design, complex deployment methodology, and being limited to a specific application or dataset. To address these challenges, we propose High-Velocity AI Cache (HVAC), a distributed read-cache layer that targets and fully exploits the node-local storage or near node-local storage technology. HVAC seamlessly accelerates read I/O by aggregating node-local or near node-local storage, avoiding metadata lookups and file locking while preserving portability in the application code. We deploy and evaluate HVAC on 1,024 nodes (with over 6000 NVIDIA V100 GPUS) of the Summit supercomputer. In particular, we evaluate the scalability, efficiency, accuracy, and load distribution of HVAC compared to GPFS and XFS-on-NVMe. With four different DL applications, we observe an average 25 % performance improvement atop GPFS and 9% drop against XFS-on-NVMe, which scale linearly and are considered the performance upper bound. We envision HVAC as an important caching library for upcoming HPC supercomputers such as Frontier.

Khan, Awais↗