Search NASA⌕ Search

SEARCH · Search NASA

Results for “High loading rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Fabrication Technologies of the High Gradient Accelerator Structures at 100MV/M Range

A CERN-SLAC-KEK collaboration on high gradient X-band structure research has been established in order to demonstrate the feasibility of the CLIC baseline design for the main linac stably operating at more than 100 MV/m loaded accelerating gradient. Several prototype CLIC structures were successfully fabricated and high power tested. They operated at 105 MV/m with a breakdown rate that meets the CLIC linear collider specifications of < 5 x 10{sup -7}/pulse/m. This paper summarizes the fabrication technologies including the mechanical design, precision machining, chemical cleaning, diffusion bonding as well as vacuum baking and all related assembly technologies. Also, the tolerances control, tuning and RF characterization will be discussed.

43 PARTICLE ACCELERATORS↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Correlation of Tensile Deformation-Induced Strain in HSLA Steel with Residual Stress Distribution

During service, due to the dynamic loading rates encountered, structural components experience varying levels of plastic deformation which leads to changes in the mechanical behavior of materials. The dynamic loading leads to non-homogenous plastic deformation which changes the residual stress distribution. In this study, the magnitude and distribution of residual stress in tensile tested specimens of high-strength low-alloy steel were investigated using x-ray diffraction technique, by varying the deformation rate. Tensile testing was performed at four different strain rates, and residual stress measurement was done along the length of the fractured specimens. Distribution of residual stress was observed all along the length of the specimens which is attributed to the varying levels of plastic deformation. Measured residual stresses are correlated with elastic strain and plastic strain obtained from the tensile tests. Consistent decrease in the magnitude of residual stress with an increase in plastic strain is observed with decreasing strain rate at the necking region. Specimen with lower yield strength experienced higher plastic strains, hence lower elastic residual stresses. The reasons for the observed distribution of residual stress are discussed with XRD peak broadening associated with plastic deformation.

36 MATERIALS SCIENCE↗

The Global Fingerprint of Modern Ice-Mass Loss on 3-D Crustal Motion

Crustal motion generated by rapid ice-mass loss from Earth's glaciers and ice sheets has previously been considered in Global Navigational Satellite System (GNSS) analyses and numerical models across regions of ice retreat. However, the fingerprint of ice-mass loss is not limited to glaciated areas, but is characterized by a global pattern of 3-D crustal deformation. We compute “far-field” vertical and horizontal deformation rates that occurred in response to early 21st century mass flux from the Greenland and Antarctic Ice Sheets, global glaciers and ice caps, and associated ocean loading. We demonstrate that mass changes in the Greenland Ice Sheet and high latitude glacier systems each generated average crustal motion of 0.1–0.4 mm/yr across much of the Northern Hemisphere, with significant year-to-year variability in magnitude and direction. Horizontal motions associated with ice-mass loss exceed vertical rates in many far-field areas, and both should be considered in future analysis of GNSS measurements.

58 GEOSCIENCES↗

Characterizing peak electricity demand for U.S. households: an assessment of end-use loads and demand factors

Understanding household peak electricity demand is critical to evaluate the technical need for electrical infrastructure upgrades. This study characterizes peak loads for existing and new equipment using metered data from a convenience sample of 11,940 U.S. dwellings from four sources, including 911 from two sources with end-use metering. After standardized data cleaning and labeling, we derived descriptive statistics for key metrics, such as maximum demand and demand factors, and developed predictive models relating 60- to 15-min demand for the National Electrical Code (NEC). Mean 15-min maximum demand was 9.7 kW (median 9.0 kW; IQR 7.0–11.5 kW, 95% CI 9.6–9.8 kW), indicating spare capacity in 98% of homes with hypothetical 100 A panels. Maximum demand increased with floor area and number of high-demand loads. Dwelling maximum demand was driven by higher-power, longer-duration heating appliances and vehicle charging, while most user-operated appliances contributed little. Demand factors are used to account for how most devices contribute less than their rated power to maximum demand. Existing load mean demand factors (28%; median 10%; IQR 0–58%; CI 28–29%) were higher than those for new loads (21%; median 7%; IQR 0–35%; CI 20–21%), because new loads changed the timing and magnitude of maximum demand. New high-demand loads had higher than average demand factors (40–60%). Whole dwelling demand factors support the NEC's 40% assumption, but they challenge its conservative 100% treatment of new HVAC. We propose a data-driven 50% demand factor for new equipment, which would align with metered data, improve affordability, and modernize electrical codes.

Appliances↗

Techno-economic and thermodynamic analysis of pre-cooling systems at gaseous hydrogen refueling stations

In this study, we conducted a techno-economic and thermodynamic analysis of precooling units (PCUs) at hydrogen refueling stations and developed a cost-minimizing design algorithm for the PCU observing the SAE J2601 refueling protocol for T40 stations. In so doing, we identified major factors that affect PCU cost and energy use. The hydrogen precooling energy intensity depends strongly on the station utilization rate, but approaches 0.3 kWh e /kg-H 2 at full utilization. In early fuel cell electric vehicle markets where utilization of the refueling capacity is low, the overhead cooling load (to keep the heat exchanger cold at -40°C) results in significantly high PCU energy intensity because only a small amount of hydrogen is being dispensed. We developed a parameterized precooling energy intensity prediction formula as a function of the ambient temperature and station utilization rate. We also found that the Joule-Thomson effect of the flow control device introduces a significant increase in temperature upstream of the PCU’s heat exchanger (HX), which impacts the PCU design capacity. An optimal PCU (per dispenser, at 35°C HX inlet temperature) consists of a 13-kW refrigerator and a HX with 1400 kg of thermal mass (aluminum), which currently costs $70,000 (uninstalled). Finally, the total (installed) capital and operation cost of PCU at a fully utilized hydrogen refueling station adds $0.50/kg-H 2 .

08 HYDROGEN↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders: Preprint

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WASTE LOADING ENHANCEMENTS FOR HANFORD LAW GLASSES VLS-10R1790-1 FINAL REPORT REV 0 12/1/2010

About 50 million gallons of high-level mixed waste is currently stored in underground tanks at The United States Department of Energy's (DOE's) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE's Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in an engineered facility on the Hanford site while the IHLW product will likely be directed to a national deep geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The Office of River Protection is currently examining options to optimize the Low Activity Waste (LAW) Facility and LAW glass waste form. One option under evaluation is to enhance the waste processing rate of the vitrification plant currently under construction. It is likely that the capacity of the LAW vitrification plant can be increased incrementally by implementation of a variety of low-risk, high-probability changes, either separately or in combination. These changes include: (1) Operating at the higher processing rates demonstrated at the LAW pilot melter; (2) Increasing the glass pool surface area within the existing external melter envelope; (3) Increasing the glass waste loading; and (4) Operating the melter at a slightly higher temperature. The Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) and Energy Solutions, Inc. have evaluated several of these potential incremental improvements for ORP in support of its evaluation of WTP LAW facility optimization. Some of these incremental improvements have been tested at VSL including increasing the waste loading, increasing the processing temperature, and increasing the fraction of the sulfur in the feed that is partitioned to the off-gas (in the event that a decision is made to break the present WTP recycle loop). These approaches successfully demonstrated increases in glass production rates and significant increases in sulfate incorporation at the nominal melter operating temperature of 1150 C and at slightly higher than nominal glass processing temperatures. Subsequent tests demonstrated further enhancement of glass formulations for all of the LAW waste envelopes, thereby reducing the amount of glass to be produced by the WTP for the same amount of waste processed. The next phase of testing determined the applicability of these improvements over the expected range of sodium and sulfur concentrations for Hanford LAW. This approach was subsequently applied to an even wider range of LAW wastes types, including those with high potassium concentration. The feasibility of formulating higher waste loading glasses using SnO{sub 2} and V{sub 2}O{sub 5} in place of Fe{sub 2}O{sub 3} and TiO{sub 2} as glass former additives was also evaluated. The present report provides data from investigation of the effects of magnesium content (up to {approx}10 wt%) on LAW glass properties and from work to identify improved high waste loading glass formulations that meets all processing and product quality requirements for two waste compositions. The scope of testing is detailed in the Test Plan for this work. A glass composition previously developed and tested at VSL for LAW from tank AN-105 (LAWA187) was varied by substituting Mg for other glass former additives such as Ca, B and Si in an attempt to formulate a glass with improved properties, such as higher waste loading and greater sulfur tolerance. The results were used to reformulate another glass (ORPLG9) developed for LAW from tank AP-101 that contains high concentrations of alkalis (Na and K). Glass formulation goals for this waste were to increase the sulfur tolerance of the glass as well as to decrease refractory corrosion. Each of the two final glass compositions was evaluated to determine the maximum amount of sulfur that can be incorporated into the glass through melter testing. The results from these tests together with earlier work for ORP were evaluated to develop recommendations for the work scope necessary to modify and update the WTP LAW glass formulation correlation algorithm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lubrication of high-speed, large bore tapered-roller bearings

The performance of 120.65-mm- (4.75-in.-) bore tapered-roller bearings was investigated at shaft speeds up to 15,000 rpm (18,000 DN). Temperature distribution and bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rate, and lubricant inlet temperature. Lubricant was supplied either by jets or by a combination of holes through the cone directly to the cone-rib contact and jets at the roller small-end side. Cone-rib lubrication significantly improved high-speed tapered-roller bearing performance, yielding lower cone-face temperatures and lower power loss and allowing lower lubricant flow rates for a given speed condition. Bearing temperatures increased with increased shaft speed and decreased with increased lubricant flow rate. Bearing power loss increased with increased shaft speed and increased lubricant flow rate.

Parker, R. J.↗

Aerothermal evaluation of a spherically blunted body with a trapezoidal cross section in the Langley 8-foot high-temperature tunnel

A model to be used in the flow studies and curved Thermal Protection System (TPS) evaluations was tested in the Langley 8 Foot High-Temperature Tunnel at a nominal Mach number of 6.8. The purpose of the study was to define the surface pressure and heating rates at high angles of attack (in support of curved metallic TPS studies) and to determine the conditions for which the model would be suitable as a test bed for aerothermal load studies. The present study was conducted at a nominal total temperature of 2400 and 3300 R, dynamic pressures from 2.3 to 10.9 psia, and free-stream Reynolds numbers from 4000,000 to 1,700,000/ft. The measurements consisted primarily of surface pressure and cold-wall (530 R) heating rates. Qualitative comparisons between predictions and data show that for this configuration, aerothermal tests should be limited to angles of attack between 10 and -10 degrees. Outside this range, the effects of free-stream flow nonuniformity appear in the data, as a result of the long length of the model. However, for TPS testing, this is not a concern and tests can be performed at angles of attack ranging from 20 to -20 degrees. Laminar and naturally turbulent boundary layers are available over limited ranges of conditions.

Albertson, Cindy W.↗

Cobalt nanoparticle-encapsulated carbon nanowire arrays: Enabling the fast redox reaction kinetics of lithium-sulfur batteries

The commercial application of lithium-sulfur batteries is still impeded by the unsatisfying cyclability due to the sluggish reaction kinetics and shuttling effect of polysulfide intermediates. We develop a cobalt nanoparticle-encapsulated carbon nanowire arrays on carbon cloth (CC@Co-CNAs) to enable the fast redox reaction kinetics of the lithium sulfur batteries. The nanowire array-decorated carbon cloth as conductive matrix for sulfur active material could provide highly exposed cobalt nanoparticle active sites, owing to the high length-diameter ratio of the prepared CC@Co-CNAs. The binding affinity between the cobalt nanoparticle-incorporated materials and polysulfide intermediates is enhanced by Co-S bonds, which facilitates the redox reaction of active materials and consequently results in a high sulfur utilization for cathode especially with high sulfur loading. The lithium sulfur battery with CC@Co-CNAs as electrode materials delivers a high initial discharge capacity of 1228 mAh g –1 at 0.25 C, and a high initial discharge capacity of 807 mAh g –1 at 1C with a low capacity fading rate of 0.06% per cycle during 300 cycles. Furthermore, a discharge capacity of 958 mAhg –1 at 0.1 C is achieved for the cell even with a corresponding sulfur loading of 6.2 mg cm –2 .

25 ENERGY STORAGE↗

High‐Rate Polymeric Redox in MXene‐Based Superlattice‐Like Heterostructure for Ammonium Ion Storage

Abstract Achieving both high redox activity and rapid ion transport is a critical and pervasive challenge in electrochemical energy storage applications. This challenge is significantly magnified when using large‐sized charge carriers, such as the sustainable ammonium ion (NH 4 + ). A self‐assembled MXene/n‐type conjugated polyelectrolyte (CPE) superlattice‐like heterostructure that enables redox‐active, fast, and reversible ammonium storage is reported. The superlattice‐like structure persists as the CPE:MXene ratio increases, accompanied by a linear increase in the interlayer spacing of MXene flakes and a greater overlap of CPEs. Concurrently, the redox activity per unit of CPE unexpectedly intensifies, a phenomenon that can be explained by the enhanced de‐solvation of ammonium due to the increased volume of 3 Å‐sized pores, as indicated by molecular dynamic simulations. At the maximum CPE mass loading (MXene:CPE ratio = 2:1), the heterostructure demonstrates the strongest polymeric redox activity with a high ammonium storage capacity of 126.1 C g −1 and a superior rate capability at 10 A g −1 . This work unveils an effective strategy for designing tunable superlattice‐like heterostructures to enhance redox activity and achieve rapid charge transfer for ions beyond lithium.

36 MATERIALS SCIENCE↗

Lithium promotion of Pt/m-ZrO 2 catalysts for low temperature water-gas shift

Low temperature water-gas shift (LTS) is an important reaction occurring in a fuel processor for producing and purifying hydrogen. Platinum supported on m-ZrO 2 belongs to a family of catalysts consisting of metal nanoparticles and an active partially reducible oxide, with the catalysis proposed to occur at the boundary between metal particles and the support. In this investigation, increasing the loading of lithium dopant increased the LTS rate up to 0.54 wt % lithium, where conversion was 2.4 times that of the unpromoted catalyst at 260°C. Further increases in lithium loading up to 1.5 wt % decreased the rate, although it remained higher than that of the unpromoted catalyst. Infrared spectroscopy and CO 2 temperature programmed desorption experiments showed three effects with increasing lithium loading: (1) lithium promoter weakened the C–H bond of formate, the proposed rate limiting step of the interfacial surface formate mechanism; (2) high levels of lithium suppressed the platinum site capacity required for hydrogen transfer; and (3) high levels of lithium increased catalyst basicity. Aspects (2) and (3) tended to inhibit desorption of product CO 2 , an acidic molecule the removal of which is metal-catalyzed. XANES and XPS experiments revealed that electron transfer to enrich Pt nanoparticles is unlikely the root cause of C–H bond weakening in formate. However, other electronic effects (e.g., electrostatic effects or molecular rearrangement due to enhanced basicity) were not ruled out.

08 HYDROGEN↗

Effect of annealing treatment on the dry sliding wear behavior of copper

We report the effect of annealing on the wear behavior of commercial grade pure copper (Cu) was evaluated by performing unlubricated pin-on-disc wear tests of as-received and annealed samples under 0.1-10 kgf normal load. It was found that annealing at 800 °C for 24 h led to an increase of grain size of Cu from ~ 6.7 to ~ 15.3 μm and a decrease in hardness. Wear rates of both samples increased while the friction coefficients decreased with increasing normal load. Subsurface microstructure evolution and wear debris were characterized by high resolution electron backscattered diffraction (EBSD) and transmission electron microscopy (TEM) after wear tests. Dynamic recrystallization and abnormal subsurface grain growth were observed in both samples under high load. Finally, the effect of annealing on the microstructure evolution and wear resistance of Cu were discussed.

36 MATERIALS SCIENCE↗

Anisotropic strength behavior of single-crystal TATB

High-rate strength behavior plays an important role in the shock initiation of high explosives, with plastic deformation serving to localize heat into hot spots and as a mechanochemical means to enhance reactivity. Recent simulations predict that detonation-like shocks produce highly reactive nanoscale shear bands in the layered crystalline explosive TATB (1,3,5-triamino-2,4,6-trinitrobenzene), but the thresholds leading to this response are poorly understood. We utilize molecular dynamics to simulate the high-rate compressive stress–strain response of TATB, with a focus on understanding flow behavior. Here, the dependence of strength on pressure and loading axis (crystal orientation) is explored. The deformation mechanisms fall broadly into two categories, with compression along crystal layers activating a buckling/twinning mode and compression normal to the layers producing nanoscale shear bands. Despite the complexity of the underlying mechanisms, the crystal exhibits relatively straightforward stress–strain curves. Most of the crystal orientations studied show rapid strain softening following the onset of yielding, which settles to a steady flow state. Trajectories are analyzed using five metrics for local states and structural order, but most of these metrics yield similar distributions for these deformation mechanisms. On the other hand, a recently proposed measure of intramolecular strain energy is found to most cleanly distinguish between these mechanisms, while also providing a plausible connection with mechanochemically accelerated decomposition kinetics. Localization of intramolecular strain energy is found to depend strongly on crystal orientation and pressure.

36 MATERIALS SCIENCE↗

Cyclic-load crack growth in ASME SA-105 grade II steel in high-pressure hydrogen at ambient temperature

ASME SA-105 Grade II steel, which is used in high-pressure hydrogen compressor systems, is similar to steels used or considered for use in high-pressure hydrogen storage vessels and pipelines. This paper summarizes the results of a program conducted to provide cyclic-load crack growth rate (da/dN) data for a fracture mechanics analysis of a 15,000 psi hydrogen compressor facility which contains pulse quieter and after-cooler separator vessels constructed of the ASME SA-105 Grade II steel. Included in the program were tests performed to assist in establishing operating procedures that could minimize the effect of hydrogen on crack growth rates during operation.

Walter, R. J.↗

Cognitive and affective components of mental workload: Understanding the effects of each on human decision making behavior

Human factors and ergonomics researchers have recognized for some time the increasing importance of understanding the role of the construct of mental workload in flight research. Current models of mental workload suggest that it is a multidimensional and complex construct, but one that has proved difficult to measure. Because of this difficulty, emphasis has usually been placed on using direct reports through subjective measures such as rating scales to assess levels of mental workload. The NASA Task Load Index (NASA/TLX, Hart and Staveland) has been shown to be a highly reliable and sensitive measure of perceived mental workload. But a problem with measures like TLX is that there is still considerable disagreement as to what it is about mental workload that these subjective measures are actually measuring. The empirical use of subjective workload measures has largely been to provide estimates of the cognitive components of the actual mental workload required for a task. However, my research suggests that these measures may, in fact have greater potential in accurately assessing the affective components of workload. That is, for example, TLX may be more likely to assess the positive and negative feelings associated with varying workload levels, which in turn may potentially influence the decision making behavior that directly bears on performance and safety issues. Pilots, for example, are often called upon to complete many complex tasks that are high in mental workload, stress, and frustration, and that have significant dynamic decision making components -- often ones that involve risk as well.

Nygren, Thomas E.↗