Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A hardware demonstration of distributed control for a flexible offset-feed antenna

A fully instrumented hardware model of a flexible offset-feed antenna has been constructed for laboratory tests. Three rate gyros, four angular position laser sensors, and a set of ten distributed accelerometers are used to rconstruct the antenna state. Three control moment gyros are used to simultaneously orient the antenna, and to maintain a stable line of sight. A description is presented of the distributed antenna control system and experimental results.

Schaechter, D. B.↗

Portable Video/Digital Retinal Funduscope

Lightweight, inexpensive electronic and photographic instrument developed for detection, monitoring, and objective quantification of ocular/systemic disease or physiological alterations of retina, blood vessels, or other structures in anterior and posterior chambers of eye. Operated with little training. Functions with human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in hospital, laboratory, field, or other environment. Produces video images viewed directly and/or digitized for simultaneous or subsequent analysis. Also equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images of skin, nose, ear, throat, or mouth to detect lesions or diseases.

Taylor, Gerald R.↗

What we Hope to Learn about Global Mineral Dust Aerosols from EOS Multi-Angle Imaging SpectroRadiometer (MISR)

On global scales, just a few broad atmospheric aerosol compositional groups are commonly observed. Of these, "mineral dust" is the only group which both contains non-spherical particles, and typically has size distributions with enough large particles for particle shape to affect its visible-light-scattering properties. The MISR instrument is scheduled for launch into a 10:30 AM sun-synchronous, polar orbit aboard the EOS Terra satellite in 1999. MISR will measure the upwelling visible radiance from Earth in 4 spectral bands centered at 446, 558, 672, and 866 nm, at each of 9 emission angles spread out in the forward and aft directions along the flight path at +/-70.5 deg, +/-60.0 deg, +/-45.6 deg, +/-26.1deg, and nadir. Over a period of 7 minutes, as the spacecraft flies along, a 360 km wide swath of Earth will successively be viewed by each of the cameras, allowing MISR to sample a very large range of scattering angles; in mid latitudes, the instrument will observe scattering angles between about 60 deg and 160 deg. Global coverage will be acquired about once in 9 days at the equator; the nominal mission lifetime is 6 years. The distinction in single scattering phase function between natural distributions of spherical and randomly oriented, non-spherical particles, with a broad range of aspect ratios, shows up strongly for scattering angles ranging from about 90 deg to near 180 deg. For non-spherical particle distributions, single scattering phase functions tend to be much flatter in this region than for spherical particles. Since MISR samples the relevant range of scattering angles very well, we expect to be able to make critical distinctions between natural distributions of spherical and randomly oriented, non-spherical particles with MISR data. We anticipate that the new multiangle, multispectral data from MISR will also contain other information about particle properties, a major step beyond current spacecraft remote sensing retrievals, which obtain aerosol optical depth based on entirely assumed particle microphysical properties. According to simulations over cloud-free, calm ocean, for pure particles with natural ranges of optical depth, particle size, and indices of refraction, MISR should retrieve column optical depth for all but the darkest particles, to an uncertainty of at most 0.05 or 20%, whichever is larger, even if the particle properties are poorly known. For one common particle type, soot, constraints on the optical depth over dark ocean are very poor. The simulated measurements also should allow us to separate two to four compositional groups based on indices of refraction, and to identify three to four distinct size groups between 0.1 and 2.0 microns characteristic radius at most latitudes. The technique is most sensitive to particle microphysical properties in the "accumulation mode" sizes. where particle scattering undergoes the transition from Rayleigh to large-particle regimes for the MISR wavelengths. Based on these results, we expect to distinguish air masses containing different aerosol types, routinely and globally, with multiangle remote sensing data. Such data complements in situ and field data, which can provide details about aerosol size and composition locally that are needed to assess the radiative effects of aerosols quantitatively. Both field data and correlations in space and time with likely source and sink regions will also be helpful in developing a global picture of mineral dust aerosol budgets. Further work on the expected sensitivity of MISR to natural mixtures of pure particles, including climatologically likely mineral dust components, is currently underway.

Kahn, Ralph↗

Bar Code Events in the Juno-UVS Data: Signature ~10 MeV Electron Microbursts at Jupiter

One of the most intriguing discoveries of Juno is the quasi-systematic detection of upgoing electrons above the auroral regions. Here we discuss a by-product of the most energetic component of this population: a contamination resembling bar codes in the Juno-UVS images. This pattern is likely caused by bursts of ∼10 MeV electrons penetrating the instrument. These events are mostly detected when Juno’s magnetic footprint is located poleward of the main emission relative to the magnetic pole. The signal is not periodic, but the bursts are typically 0.1–1 s apart. They are essentially detected when Juno-UVS is oriented toward Jupiter, indicating that the signal is due to upgoing electrons. The event detections occur between 1 and 7 Jovian radii above the 1-bar level, suggesting that the electron acceleration takes place close to Jupiter and is thus both strong and brief.

Microbursts↗

A prototype quantitative film scanner for radiochromic film dosimetry

We have developed a high resolution, quantitative, two-dimensional optical film scanner for use with a commercial high sensitivity radiochromic film (RCF) for measuring single fraction external-beam radiotherapy dose distributions. The film scanner was designed to eliminate artifacts commonly observed in RCF dosimetry. The scanner employed a stationary light source and detector with a moving antireflective glass film platen attached to a high precision computerized X-Y translation stage. An ultrabright red light emitting diode (LED) with a peak output at 633 nm and full width at half maximum (FWHM) of 16 nm was selected as the scanner light source to match the RCF absorption peak. A dual detector system was created using two silicon photodiode detectors to simultaneously measure incident and transmitted light. The LED light output was focused to a submillimeter (FWHM 0.67 mm) spot size, which was determined from a scanning knife-edge technique for measuring Gaussian optical beams. Data acquisition was performed with a 16-bit A/D card in conjunction with commercial software. The linearity of the measured densities on the scanner was tested using a calibrated neutral-density step filter. Sensitometric curves and three IMRT field scans were acquired with a spatial resolution of 1 mm for both radiographic film and RCF. The results were compared with measurements taken with a commercial diode array under identical delivery conditions. The RCF was rotated by 90 deg. and rescanned to study orientation effects. Comparison between the RCF and the diode array measurements using percent dose difference and distance-to-agreement criteria produced average passing rates of 99.0% using 3%/3 mm criteria and 96.7% using 2%/2 mm criteria. The same comparison between the radiographic film and diode array measurements resulted in average passing rates 96.6% and 91.6% for the above two criteria, respectively. No measurable light-scatter or interference scanner artifacts were observed. The RCF rotated by 90 deg. showed no measurable orientation effect. A scan of a 15x15 cm{sup 2} area with 1 mm resolution required 22 min to acquire. The LED densitometer provides an accurate film dosimetry system with 1 mm or better resolution. The scanner eliminates the orientation dependence of RCF dosimetry that was previously reported with commercial flatbed scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral narrowing and broadening of Cr:ZnS/Se laser oscillation due to mode competition and spatial hole burning in the gain element

In this paper, we demonstrate the laser characterization of Cr:ZnS/Se polycrystalline gain media in non-selective unpolarized, linearly polarized, and twisted mode cavities. Lasers were based on post-growth diffusion-doped, commercially available antireflective-coated Cr:ZnSe and Cr:ZnS polycrystals with a length of 9 mm. The spectral output of lasers based on these gain elements in non-selective unpolarized and linearly polarized cavities was measured to be broadened to ∼20-50 nm due to the spatial hole burning (SHB) effect. SHB alleviation in the same crystals was realized in the “twisted mode” cavity, with linewidth narrowing to ∼80-90 pm. Both broadened and narrow-line oscillations were captured by adjusting the orientation of intracavity waveplates with respect to facilitated polarization.

47 OTHER INSTRUMENTATION↗

Ion-/proton-conducting apparatus and method

A c-axis-oriented HAP thin film synthesized by seeded growth on a palladium hydrogen membrane substrate. An exemplary synthetic process includes electrochemical seeding on the substrate, and secondary and tertiary hydrothermal treatments under conditions that favor growth along c-axes and a-axes in sequence. By adjusting corresponding synthetic conditions, an HAP this film can be grown to a controllable thickness with a dense coverage on the underlying substrate. The thin films have relatively high proton conductivity under hydrogen atmosphere and high temperature conditions. The c-axis oriented films may be integrated into fuel cells for application in the intermediate temperature range of 200-600.degree. C. The electrochemical-hydrothermal deposition technique may be applied to create other oriented crystal materials having optimized properties, useful for separations and catalysis as well as electronic and electrochemical applications, electrochemical membrane reactors, and in chemical sensors.

47 OTHER INSTRUMENTATION↗

High-Temperature Neutron Diffraction Study of Vanadium and Vanadium–Niobium Null-Matrix Alloy for Spectrum Normalization

This study systematically evaluates a vanadium–niobium (V 94.1 Nb 5.9 ) null-matrix alloy as a reference material for neutron spectrum normalization and compares its performance with that of pure vanadium under identical experimental conditions. Neutron diffraction experiments are conducted on the VULCAN Engineering Materials Diffractometer at the Spallation Neutron Source, Oak Ridge National Laboratory, over a temperature range from room temperature to 1200 °C under vacuum. Pure vanadium exhibited distinct Bragg peaks across all temperatures, with its diffraction behavior influenced by both sample orientation and temperature. As the temperature increased, the diffraction peaks shifted to larger d-spacings and decreased in intensity, while spectral deviation near d ≈ 2.8 Å exceeded 10% at 1200 °C. In contrast, the V–Nb alloy produced a nearly featureless spectrum over the full d-spacing range, confirming near-complete cancellation of coherent scattering over the wide temperature range. Its spectra were insensitive to sample orientation, temperature, and microstructural evolution, with spectral deviation around d ≈ 2.8 Å exceeded 5% at 1200 °C. In conclusion, these results demonstrate that the V–Nb null-matrix alloy provides a thermally stable, efficient, and reliable normalization standard for time-of-flight diffractometers or other instrument where it is needed, enabling reduced data acquisition time and improved data quality in high-temperature neutron diffraction experiments.

Alloys↗

Wavefront error simulator for evaluating optical testing instrumentation

A wavefront error simulator has been designed and fabricated to evaluate experimentally test instrumentation for the Large Space Telescope (LST) program. The principal operating part of the simulator is an aberration generator that introduces low-order aberrations of several waves magnitude with an incremented adjustment capability of lambda/100. Each aberration type can be introduced independently with any desired spatial orientation.

Golden, L. J.↗

Future lunar gravity measurements

Future missions to the moon should include a detailed high-resolution global gravity survey from a low (15-30 km) polar orbiting spacecraft. The use of gravity gradiometer instruments on board the spacecraft will give higher-resolution data at lower total mission cost than the present Doppler tracking technique. Simulations show that although a three axis gradiometer system is preferred, and can even be used to estimate spacecraft attitude and altitude variation, a properly oriented single rotating gravity gradiometer can be used to resolve closely spaced mascons in both the along-track and cross-track directions.

Forward, R. L.↗

The relationship between low-temperature toughness and secondary crack in low-carbon bainitic weld metals

Highlights: • The crack propagation plane was identified with the decreasing possibility of {110}/{100}, {112} and {123}. • Crack path deviates at some middle-angle misorientation boundaries with high strain concentration. • The most effective barrier to arrest crack in Ni0 and Ni2 is the boundaries of inter-Bain in a CPP packet, while in Ni4 the boundaries of inter-CPP and intra-Bain packets impede crack propagation. - Abstract: This paper aims to reveal the relationship among low-temperature toughness, microstructure and secondary crack from both microstructural and crystallographic perspectives. Instrumented Charpy tests were carried out in the upper platform, transition temperature range, as well as at lower temperatures. Quantitative fractographic analysis, microstructural characterization and secondary crack observation were conducted on half of the impact specimen. Crystallographic features were identified in the secondary crack proximity, e.g. variant selection, orientation relationship, cleavage plane of the corresponding crack matrix. Some results in literature are confirmed. Nickel addition is beneficial to hindering crack propagation as a result of microstructure improvement. The most effective barrier for crack propagation is high-angle misorientation boundaries between Bain packets and the boundaries of ferrite matrix with the microstructure of granular bainite. Additionally, high-angle misorientation boundaries between closed-packed plane packets arrest cracks in the mixed microstructure of fine lath bainite and intricate acicular ferrite. Most preferred crack propagation planes are {110} and {100} in our low carbon bainitic weld metals, with the decreasing possibility of {112} and {123}.

36 MATERIALS SCIENCE↗

The MESA polarimetry chain and the status of its double scattering polarimeter

We plan to have two independent polarimetry systems at MESA based on totally different physical processes. A first one tries to minimize the systematic uncertainties in double polarized Mo/ller scattering, which is to be achieved by stored hydrogen atoms in an atomic trap (Hydro-Mo/ller-Polarimeter). The other one relies on the equality of polarizing and analyzing power which allows to measure the effective analyzing power of a polarimeter with very high accuracy. Since the status of Hydro-Mo/ller is presented in a separate paper we concentrate on the double scattering polarimeter in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DISCOVERY OF CANDIDATE H{sub 2}O DISK MASERS IN ACTIVE GALACTIC NUCLEI AND ESTIMATIONS OF CENTRIPETAL ACCELERATIONS

Based on spectroscopic signatures, about one-third of known H{sub 2}O maser sources in active galactic nuclei (AGNs) are believed to arise in highly inclined accretion disks around central engines. These 'disk maser candidates' are of interest primarily because angular structure and rotation curves can be resolved with interferometers, enabling dynamical study. We identify five new disk maser candidates in studies with the Green Bank Telescope, bringing the total number published to 30. We discovered two (NGC 1320, NGC 17) in a survey of 40 inclined active galaxies (v {sub sys} < 20, 000 km s{sup -1}). The remaining three disk maser candidates were identified in monitoring of known sources: NGC 449, NGC 2979, and NGC 3735. We also confirm a previously marginal case in UGC 4203. For the disk maser candidates reported here, inferred rotation speeds are 130-500 km s{sup -1}. Monitoring of three more rapidly rotating candidate disks (CG 211, NGC 6264, VV 340A) has enabled measurement of likely orbital centripetal acceleration, and estimation of central masses ((2-7) x10{sup 7} M {sub sun}) and mean disk radii (0.2-0.4 pc). Accelerations may ultimately permit estimation of distances when combined with interferometer data. This is notable because the three AGNs are relatively distant (10,000 km s{sup -1} <v {sub sys} < 15, 000 km s{sup -1}), and fractional error in a derived Hubble constant, due to peculiar motion of the galaxies, would be small. As signposts of highly inclined geometries at galactocentric radii of approx0.1-1 pc, disk masers also provide robust orientation references that allow analysis of (mis)alignment between AGNs and surrounding galactic stellar disks, even without extensive interferometric mapping. We find no preference among published disk maser candidates to lie in high-inclination galaxies. This provides independent support for conclusions that in late-type galaxies, central engine accretion disks and galactic plane orientations are not correlated.

79 ASTRONOMY AND ASTROPHYSICS↗

The ultraviolet spectrum of a dayside aurora - 530-1500 A

Observations by rocket-borne spectrometers of the high-latitude dayside aurora above Cape Perry, N.W.T. are reported. UV spectra of optical emissions produced by ambient precipitating particles are obtained in the 530-1500 A region, over a range of spectrometer line-of-sight orientations, from 100 km to the rocket apogee of 452 km. The spectrum below 1500 A is dominated by transitions from neutral and singly ionized atomic oxygen. N I, N II, and N2 emissions, which are prominent in day airglow and nighttime auroral spectra measured by the same instrumentation, are very weak, indicating energy from the dayside auroral particles is transferred to the atmosphere above most of the N2. Relative line strengths of O I and O II transitions in the high-latitude dayside aurora differ in comparison with either airglow or nighttime auroral observations.

Gentieu, E. P.↗

Conical Mirrors For Quasi-Retroreflection

Single and multiple-nested conical mirrors assembled and positioned to provide several distinct orders of retroreflection. Design and orientation of "cones" determines positions of, and solid angles subtended by discrete orders of retroreflection. Accommodates larger range of incident angles than corner-cube reflectors. Also provides greater spectral coverage than conventional lens-and mirror retroreflectors. Potential applications include interferometry, metrology, lasers, position and motion sensors, instrument test and calibration, and expanded capability of highway markers and signs.

Dekany, Richard G.↗

Composite material shear property measurement using the Iosipescu specimen

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. Finite element analysis and moire interferometry are used to assess the uniformity of the shear stress field in the test section of unidirectional and cross-ply graphite-epoxy composites. The nonuniformity of the strain field and the sensitivity of some fiber orientations to the specimen/fixture contact mechanics are discussed. The shear responses obtained for unidirectional and cross-ply graphite-epoxy composites are discussed and problems associated with anomalous behavior are addressed. An experimental determination of the shear response of a range of material systems using strain gage instrumentation and moire interferometry is performed.

Ho, Henjen↗