Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Spatially resolved measurements of electron cyclotron resonance ion source beam profile characteristics

Simulations predict that the concentric rings and the triangular structures in the profiles of strongly focused ion beams that are found in different experiments should be dominated by ion species with the same or at least similar m/q-ratio. To verify these theoretical predictions we have tuned our ECR ion source to deliver a beam consisting of multiple ion species whose particular m/q-depending focusing ranges from weakly focused to overfocused. We then recorded spatially resolved charge-state distributions of the beam profile at characteristic positions in the plane perpendicular to the beam line. The results validate theoretical predictions and are summarized in this paper. To achieve the required beam profile characteristics we moved the extraction along the beam line to achieve stronger focusing than by only changing the extraction voltage. To fit the regions of interest of the beam profile into the transmission area of the sector magnet, we steered the beam by moving the extraction in the plane perpendicular to the beam axis. The results of both investigations, beam focusing and beam steering by using a 3D-movable extraction, are also reported in this paper. A brief overview of the new beam monitor extensively used during these measurements, the Faraday cup array, is also given.

43 PARTICLE ACCELERATORS↗

Isotopic anomaly for carbon ions in an electron cyclotron resonance ion source

In many experiments methods were applied to increase the highly charged ion output from an electron cyclotron resonance ion source; the gas-mixing method is still generally being applied. The dominant role of the masses of the ions in the gas-mixture was apparent. Two basically differing mechanisms could to first order explain most of the observations. A significant mass effect showed up in a mixture of oxygen isotopes, the so-called oxygen anomaly; so far that effect could be explained in zeroth order only. The anomaly was observed later for nitrogen isotopes as well. In the present experiment it is shown that the anomaly also exists for carbon isotopes, where the necessity of feeding the source with carbon-hydrogen compounds brings about an essential different experimental fact.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: An ion source for alkali metal implantation beneath graphene and hexagonal boron nitride monolayers on transition metals

The construction of an alkali-metal ion source is presented. It allows the acceleration of rubidium ions to an energy that enables the penetration through monolayers of graphene and hexagonal boron nitride. Rb atoms are sublimated from an alkali-metal dispenser. The ionization is obtained by surface ionization and desorption from a hot high work function surface. The ion current is easily controlled by the temperature of ionizer. Scanning Tunneling Microscopy measurements confirm ion implantation.

36 MATERIALS SCIENCE↗

Hollow target magnetron-sputter-type solid material ion source

A thin-walled aluminum (Al) hollow electrode has been inserted into an ion source to serve as an electrode for a radio frequency magnetron discharge. The produced plasma stabilized by argon (Ar) gas sputters the Al electrode to form a beam of Al{sup +} and Ar{sup +} ions. The total beam current extracted through a 3 mm diameter extraction hole has been 50 {mu}A, with the Al{sup +} ion beam occupying 30% of the total beam current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated modeling of electron cyclotron resonance ion sources and charge breeders with GEM, MCBC, and IonEx

A numerical toolset to help in understanding physical processes in the electron cyclotron resonance charge breeder (ECRCB) and further to help optimization and design of current and future machines is presented. The toolset consists of three modules (Monte Carlo charge breeding code, generalized electron cyclotron resonance ion source modeling, and ion extraction), each modeling different processes occurring in the ECRCB from beam injection to extraction. The toolset provides qualitative study, such as parameter studies, and scaling of the operation, and physical understanding in the ECRCB. The methodology and a sample integrated modeling are presented.

43 PARTICLE ACCELERATORS↗

Operation of the CAPRICE electron cyclotron resonance ion source applying frequency tuning and double frequency heating

The properties of the electromagnetic waves heating the electrons of the ECR ion sources (ECRIS) plasma affect the features of the extracted ion beams such as the emittance, the shape, and the current, in particular for higher charge states. The electron heating methods such as the frequency tuning effect and the double frequency heating are widely used for enhancing the performances of ECRIS or even for the routine operation during the beam production. In order to better investigate these effects the CAPRICE ECRIS has been operated using these techniques. The ion beam properties for highly charged ions have been measured with beam diagnostic tools. The reason of the observed variations of this performance can be related to the different electromagnetic field patterns, which are changing inside the plasma chamber when the frequency is varying.

43 PARTICLE ACCELERATORS↗

Interaction of plasmas in laser ion source with double laser system

Multiple laser shots could be used to elongate an ion beam pulse width or to intensify beam current from laser ion sources. In order to confirm the feasibility of the multiple shot scheme, we investigated the properties of plasmas produced by double laser shots. We found that when the interval of the laser shots is shorter than 10 μs, the ion current profile had a prominent peak, which is not observed in single laser experiments. The height of this peak was up to five times larger than that of single laser experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of a magnetic filter for negative ion sources. II. E Multiplication-Sign B drift through the filter in a real geometry

The physics of a magnetic filter under conditions similar to those of the negative ion source for the ITER neutral beam injector is analyzed with the help of a two-dimensional particle-in-cell Monte Carlo Collisions model. A detailed analysis of the different terms of the electron momentum equations shows how diamagnetic and drift currents can be dominant in different regions of the filter. Electron transport through the filter is due to an E Multiplication-Sign B drift current on one side of the chamber induced by the presence of the chamber walls perpendicular to the electron diamagnetic current. The filter design of the ITER negative ion source, which does not allow a closed electron diamagnetic current, induces an asymmetry of the plasma that is analyzed with the particle model. It is shown that electron transport through the filter in this geometry is very different from the transport in an ideal, one-dimensional magnetic filter often considered in the literature and described in detail in the companion paper [Boeuf et al., Phys. Plasmas 19, 113509 (2012)].

43 PARTICLE ACCELERATORS↗

The preliminary tests of the superconducting electron cyclotron resonance ion source DECRIS-SC2

A new compact version of the ''liquid He-free'' superconducting ECR ion source, to be used as an injector of highly charged heavy ions for the MC-400 cyclotron, is designed and built at the Flerov Laboratory of Nuclear Reactions in collaboration with the Laboratory of High Energy Physics of JINR. The axial magnetic field of the source is created by the superconducting magnet and the NdFeB hexapole is used for the radial plasma confinement. The microwave frequency of 14 GHz is used for ECR plasma heating. During the first tests, the source shows a good enough performance for the production of medium charge state ions. In this paper, we will present the design parameters and the preliminary results with gaseous ions.

43 PARTICLE ACCELERATORS↗

Measurement of Electron Density near Plasma Grid of Large-scaled Negative Ion Source by Means of Millimeter-Wave Interferometer

A millimeter-wave interferometer with the frequency of 39 GHz ({lambda} 7.7 mm) was newly installed to a large-scaled negative ion source. The measurable line-integrated electron density (n{sub e}l) is from 2x10{sup 16} to 7x10{sup 18} m{sup -2}, where n{sub e} and l represent an electron density and the plasma length along the millimeter-wave path, respectively. Our interest in this study is behavior of negative ions and reduction of electron density in the beam extraction region near the plasma grid. The first results show the possibility of the electron density measurement by the millimeter-wave interferometer in this region. The line-averaged electron density increases proportional to the arc power under the condition without cesium seeding. The significant decrease of the electron density and significant increase of the negative ion density were observed just after the cesium seeding. The electron density measured with the interferometer agrees well with that observed with a Langmuir probe. The very high negative ion ratio of n{sub H-}/(n{sub e}+n{sub H-}) = 0.85 was achieved within 400 min. after the cesium seeding.

43 PARTICLE ACCELERATORS↗

Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma

A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

43 PARTICLE ACCELERATORS↗

H- Ion Source Development for the FNAL 750keV Injector Upgrade

The new FNAL 750keV injector upgrade for the replacement of the 40 year old Fermi National Laboratory (FNAL) Cockcroft-Walton accelerators with a new ion source and 200MHz Radio Frequency Quadrupole (RFQ), Low Energy Beam Transport (LEBT) and Medium Energy Beam Transport (MEBT) [1], has been built and is now being tested prior to installation during the 2012 shutdown. The new H-' ion source is a round aperture magnetron which was developed at Brookhaven National Lab (BNL) by Jim Alessi[2]. Operational experience from BNL has shown that this type of source is more reliable with a longer lifetime (on the order of 6 to 9 months) due to better power efficiency. With a similar duty factor to BNL, we expect to have a comparable lifetime between source changes. The new source design reliably produces 90mA of H-' beam current at 15Hz rep-rate, 250mus pulse width, and a duty factor of 0.38%A The measured emittances at the end of the LEBT are horizontally H = 0.21I mm- mrad and vertically V = 0.17I mm- mrad. With 35kV extraction the power efficiency is 60mA/kW. The source design, along with data from a test stand and the LEBT, will be presented in this paper.

43 PARTICLE ACCELERATORS↗

Enhanced surface production in H{sup -} ion sources by introducing a negatively biased secondary electrode

A transformer coupled plasma negative hydrogen ion source with an external rf antenna has been developed at SNU, which is capable of continuous operation with long lifetime. A positively biased plasma electrode (PE) has been successfully used for the optimization of H{sup -} extraction. With molybdenum-coated stainless steel PE, the enhancement of H{sup -} production at the electrode surface was observed at the bias voltage lower than the plasma potential. However, the low bias voltage is unfavorable to H{sup -} beam extraction since the negative ions are repelled. A second electrode is inserted in front of the PE to enhance H{sup -} production at the electrode surface without impeding beam extraction. By biasing the secondary electrode (SE) more negatively, H{sup -} production is clearly enhanced although the SE itself reduces H{sup -} beam currents because of suppressed electron transport in front of the PE. In this configuration enhancement of surface productions is most pronounced in tantalum electrode among various electrode materials.

43 PARTICLE ACCELERATORS↗

Non-ideal operating conditions of the ion source prototype for the ITER neutral beam injector due to thermal deformation of the support structure

The beam formation and acceleration of the ITER neutral beam injector will be studied in the full-scale ion source, Source for Production of Ions of Deuterium Extracted from a RF plasma (SPIDER). It will be able to sustain 40 A deuterium ion beam during 1-h pulses. The operating conditions of its multi-aperture electrodes will diverge from ideality, as a consequence of inhomogeneous heating and thermally induced deformations in the support structure of the extraction and acceleration grids, which operate at different temperatures. Meeting the requirements on the aperture alignment and distance between the grids with such a large number of apertures (1280) and the huge support structures constitute a challenge. Examination of the structure thermal deformation in transient and steady conditions has been carried out, evaluating their effect on the beam performance: the paper describes the analyses and the solutions proposed to mitigate detrimental effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A liquid-helium-free superconducting coil system forming a flat minimum-magnetic-field distribution of an electron cyclotron resonance ion source

A flat distribution of the minimum magnetic field (flat-B{sub min}) of an electron cyclotron resonance ion source (ECRIS) is expected to perform better in highly charged ion production than classical B{sub min}. To form a flat-B{sub min} structure with a liquid helium-free superconducting device, a coil system of seven coils with four current leads has been designed. The lead number was reduced by connecting the plural coils in series to maintain the flat-B{sub min} structure even when the coil currents are changed for adjustment. This coil system can be operated with a helium-free cryostat, since the estimation of heat from the leads to the coils is nearly equivalent to the existing superconducting ECRIS of a similar type.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a new superconducting electron cyclotron resonance ion source for operations up to 18 GHz at LBNL

A new superconducting Electron Cyclotron Resonance Ion Source (ECRIS) is under development at LBNL to harness the winding techniques of a closed-loop sextupole coil for the next generation ECRIS and to enhance the capability of the 88-in. cyclotron facility. The proposed ECRIS will use a superconducting closed-loop sextupole coil to produce the radial field and a substantial portion of the axial field. The field strengths of the injection, central and extraction regions are adjusted by a three solenoids outside the closed-loop sextupole coil. In addition to maintaining the typical ECRIS magnetic field configuration, this new source will also be able to produce a dustpan-like minimum-B field to explore possible ECRIS performance enhancement. The dustpan-like minimum-B field configuration has about the same strengths for the maximum axial field at the injection region and the maximum radial pole fields at the plasma chamber walls but it can be substantially lower at the extraction region. The dustpan-like minimum-B will have a field maximum B{sub max} ≥ 2.6 T for operations up to 18 GHz with a ratio of B{sub max}/B{sub res} ≥ 4 and higher ratios for lower frequencies. The field maxima of this new source can reach over 3 T both at the injection and the plasma chamber walls which could also support operation at 28 GHz. The source will be built of cryogen-free with the magnets directly cooled by cryo-coolers to simplify the cryostat structure. The source design features will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Influence of discharge gap on the discharge stability in a short vacuum arc ion source

The influence of the discharge gap between cathode and anode on the discharge stability in a short vacuum arc (SVA) ion source is presented in this paper. Planar cathode and cylindrical hollow anode made of titanium are investigated. There is a great need in present accelerator injection research for SVA source to produce the small deviation of the ion current beam. Current research shows that increasing the short discharge gap can reduce the level of ion current deviation and ion charge deviation from 29% and 31% to 15% and 17%, respectively. A microplasma plume generation mechanism in SVA and scanning electron microscopic results can be used to explain this interesting phenomenon.

43 PARTICLE ACCELERATORS↗

Study of ion beam extraction and transport from an electron cyclotron resonance ion source

We have started an experimental and theoretical program to better understand the extraction and transport of intense multiply charged ion beams from an electron cyclotron resonance ion source (ECRIS). In this paper we present the first results of this program concerning a simple, monocomponent He{sup +} beam extracted from an ECRIS. We have calculated the ion trajectories starting from the ECRIS plasma electrode up to the image plane of the analyzing magnet taking into account space-charge effects and fringe fields. The initial phase-space distribution of the He{sup +} beam at the extraction aperture has been calculated with a particle-in-cell code. To check the simulations we have measured beam profiles with a viewing screen both before and after the analyzing magnet. In addition also measurements with a pepperpot emittance meter located behind the analyzing magnet have been performed. We find good agreement between these measurements and simulations showing that (i) there is a significant compensation of the space charge and that (ii) our analyzing magnet causes a severe increase in effective beam emittance.

43 PARTICLE ACCELERATORS↗