Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging System Camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

The Dark Energy Survey Data Processing and Calibration System

The Dark Energy Survey (DES) is a 5000 deg2 grizY survey reaching characteristic photometric depths of 24th magnitude (10 sigma) and enabling accurate photometry and morphology of objects ten times fainter than in SDSS. Preparations for DES have included building a dedicated 3 deg2 CCD camera (DECam), upgrading the existing CTIO Blanco 4m telescope and developing a new high performance computing (HPC) enabled data management system (DESDM). The DESDM system will be used for processing, calibrating and serving the DES data. The total data volumes are high (~2PB), and so considerable effort has gone into designing an automated processing and quality control system. Special purpose image detrending and photometric calibration codes have been developed to meet the data quality requirements, while survey astrometric calibration, coaddition and cataloging rely on new extensions of the AstrOmatic codes which now include tools for PSF modeling, PSF homogenization, PSF corrected model fitting cataloging and joint model fitting across multiple input images. The DESDM system has been deployed on dedicated development clusters and HPC systems in the US and Germany. An extensive program of testing with small rapid turn-around and larger campaign simulated datasets has been carried out. The system has also been tested on large real datasets, including Blanco Cosmology Survey data from the Mosaic2 camera. In Fall 2012 the DESDM system will be used for DECam commissioning, and, thereafter, the system will go into full science operations.

79 ASTRONOMY AND ASTROPHYSICS↗

Extremely High Resolution Single Crystal Diffractometory for Orbital Resolution using High Energy Synchrotron Radiation at SPring-8

The investigation of accurate structure at charge density level will not only understand the function mechanism of physical property but also lead to design new functional materials. We have successfully installed large cylindrical camera at the BL02B1/SPring-8. In conceptual design, the image plate (IP) was selected as the detector, because such IP will not only detect wide range in one shot but also yield reliable data. In commissioning, the performance of this camera demonstrated to be suitable for the direct observation of d-electron system.

43 PARTICLE ACCELERATORS↗

HERSCHEL-RESOLVED OUTER BELTS OF TWO-BELT DEBRIS DISKS AROUND A-TYPE STARS: HD 70313, HD 71722, HD 159492, AND F-TYPE: HD 104860

We present dual-band Herschel/Photodetector Array Camera and Spectrometer imaging for four stars whose spectral energy distributions (SEDs) suggest two-ring disk architectures that mirror that of the asteroid-Kuiper Belt geometry of our own solar system. The Herschel observations at 100 μm spatially resolve the cold/outer-dust component for each star-disk system for the first time, finding evidence of planetesimals at >100 AU, i.e., a larger size than assumed from a simple blackbody fit to the SED. By breaking the degeneracy between the grain properties and the dust's radial location, the resolved images help constrain the dust grain-size distribution for each system. Three of the observed stars are A-type and one solar-type. On the basis of the combined Spitzer/IRS+MIPS (5-70 μm), the Herschel/PACS (100 and 160 μm) dataset, and under the assumption of idealized spherical grains, we find that the cold/outer belts of the three A-type stars are well fit with a mixed ice/rock composition rather than pure rocky grains, while the debris around the solar-type star is consistent with either rock or ice/rock grains. For the solar-type star HD 104860, we find that the minimum grain size is larger than expected from the threshold set by radiative blowout. The A-type stars HD 71722 and HD 159492, on the other hand, require minimum grain sizes that are smaller than blowout for inner- and outer-ring populations. In the absence of spectral features for ice, we find that the behavior of the continuum can help constrain the composition of the grains (of icy nature and not pure rocky material) given the Herschel-resolved locations of the cold/outer-dust belts.

79 ASTRONOMY AND ASTROPHYSICS↗

2-20 ns interframe time 2-frame 6.151 keV x-ray imaging on the recently upgraded Z Accelerator: A progress report

When used for the production of an x-ray imaging backlighter source on Sandia National Laboratories' recently upgraded 26 MA Z Accelerator, the terawatt-class, multikilojoule, 526.57 nm Z-Beamlet laser (ZBL) [P. K. Rambo et al., Appl. Opt. 44, 2421 (2005)], in conjunction with the 6.151 keV (1s{sup 2}-1s2p triplet line of He-like Mn) curved-crystal imager [D. B. Sinars et al., Rev. Sci. Instrum. 75, 3672 (2004); G. R. Bennett et al., Rev. Sci. Instrum. 77, 10E322 (2006)], is capable of providing a high quality x radiograph per Z shot for inertial confinement fusion (ICF), complex hydrodynamics, and other high-energy-density physics experiments. For example, this diagnostic has recently afforded microgram-scale mass perturbation measurements on an imploding ignition-scale 1 mg ICF capsule [G. R. Bennett et al., Phys. Rev. Lett. 99, 205003 (2007)], where the perturbation was initiated by a surrogate deuterium-tritium (DT) fuel fill tube. Using an angle-time multiplexing technique, ZBL now has the capability to provide two spatially and temporally separated foci in the Z chamber, allowing 'two-frame' imaging to be performed, with an interframe time range of 2-20 ns. This multiplexing technique allows the full area of the four-pass amplifiers to be used for the two pulses, rather than split the amplifiers effectively into two rectangular sections, with one leg delayed with respect to the other, which would otherwise double the power imposed onto the various optics thereby halving the damage threshold, for the same irradiance on target. The 6.151 keV two frame technique has recently been used to image imploding wire arrays, using a 7.3 ns interframe time. The diagnostic will soon be converted to operate with p-rather than s-polarized laser light for enhanced laser absorption in the Mn foil, plus other changes (e.g., operation at the possibly brighter 6.181 keV Mn 1s{sup 2}-1s2p singlet line), to increase x-ray yields. Also, a highly sensitive inline multiframe ultrafast (1 ns gate time) digital x-ray camera is being developed [G. R. Bennett et al., Rev. Sci. Instrum. 77, 10E322 (2006)] to extend the system to 'four-frame' and markedly improve the signal-to-noise ratio. [At present, time-integrating Fuji BAS-TR2025 image plate (scanned with a Fuji BAS-5000 device) forms the time-integrated image-plane detector.].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of channel diameter on flow pattern, void fraction and pressure drop of two-phase air-water flow in circular micro-channels

Two-phase air-water flow characteristics are experimentally investigated in horizontal circular micro-channels. Test sections are made of fused silica. The experiments are conducted based on three different inner diameters of 0.53, 0.22 and 0.15 mm with the corresponding lengths of 320, 120 and 104 mm, respectively. The test runs are done at superficial velocities of gas and liquid ranging between 0.37-42.36 and 0.005-3.04 m/s, respectively. The flow visualisation is facilitated by systems mainly including stereozoom microscope and high-speed camera. The flow regime maps developed from the observed flow patterns are presented. The void fractions are determined based on image analysis. New correlation for two-phase frictional multiplier is also proposed for practical applications. (author)

42 ENGINEERING↗

Multishell Au/Ag/SiO 2 nanorods with tunable optical properties as single particle orientation and rotational tracking probes

In this study, three-layer core–shell plasmonic nanorods (Au/Ag/SiO 2 –NRs), consisting of a gold nanorod core, a thin silver shell, and a thin silica layer, were synthesized and used as optical imaging probes under a differential interference contrast microscope for single particle orientation and rotational tracking. The localized surface plasmon resonance modes were enhanced upon the addition of the silver shell, and the anisotropic optical properties of gold nanorods were maintained. The silica coating enables surface functionalization with silane coupling agents and provides enhanced stability and biocompatibility. Taking advantage of the longitudinal LSPR enhancement, the orientation and rotational information of the hybrid nanorods on synthetic lipid bilayers and on live cell membranes were obtained with millisecond temporal resolution using a scientific complementary metal-oxide-semiconductor camera. The results demonstrate that the as-synthesized hybrid nanorods are promising imaging probes with improved sensitivity and good biocompatibility for single plasmonic particle tracking experiments in biological systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EVIDENCE OF PHOTOEVAPORATION AND SPATIAL VARIATION OF GRAIN SIZES IN THE ORION 114-426 PROTOPLANETARY DISK

Deep Hubble Space Telescope broadband images taken with Advanced Camera for Surveys (ACS) and WFPC2 of the giant ({approx}1000 AU diameter) dark silhouette proplyd 114-426 in the Orion Nebula show that this system is tilted, asymmetric, warped, and photoevaporated. The exquisite angular resolution of ACS allows us to map the distribution of dust grains at the northern translucent edge of the disk, dominated by the photoevaporative flow. Using the Mie theory for standard circumstellar disk grains, we find evidence for a spatial gradient in grain size. The typical dust radius {approx_equal} 0.2-0.7 {mu}m (less than what was reported by previous studies) becomes smaller as the distance from the disk center increases, consistent with the expectations for the dynamic of dust entrained in a gaseous photoevaporative wind. Our analysis of the disk morphology and location within the nebula indicates that this system is photoevaporated by the diffuse radiation field of the Orion Nebula, while being shielded from the radiation coming directly from the central Trapezium stars. We estimate the mass-loss rate from the disk surface and the timescale for total disk dissipation, which turns out to be of the order of 10{sup 4} yr. Such a short time, of the order of 1/100 of the cluster age, indicates that this system is seen on the verge of destruction. This is compatible with the exceptional nature of the disk, namely its combination of huge size and low mass. Finally, we briefly discuss the viability of possible mechanisms that may lead to the peculiar morphology of this system: external UV flux, binary star, and past close encounter.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular Breast Imaging Using Emission Tomosynthesis

Purpose: Tour objective is to design a novel SPECT system for molecular breast imaging (MBI) and evaluate its performance. The limited angle SPECT system, or emission tomosynthesis, is designed to achieve 3D images of the breast with high spatial resolution/sensitivity. The system uses a simplified detector motion and is conducive to on-board biopsy and mult-modal imaging with mammography. Methods: The novel feature of the proposed gamma camera is a variable-angle, slant-hole (VASH) collimator, which is well suited for limited angle SPECT of a mildly compressed breast. The collimator holes change slant angle while the camera surface remains flush against the compression paddle. This allows the camera to vary the angular view ({+-}30{degrees}, {+-}45{degrees}) for tomographic imaging while keeping the camera close to the object for high spatial resolution and/or sensitivity. Theoretical analysis and Monte Carlo simulations were performed assuming a point source and isolated breast phantom. Spatial resolution, sensitivity, contrast and SNR were measured. Results were compared to single-view, planar images and conventional SPECT. For both conventional SPECT and VASH, data were reconstructed using iterative algorithms. Finally, a proof-of-concept VASH collimator was constructed for experimental evaluation. Results: Measured spatial resolution/sensitivity with VASH showed good agreement with theory including depth-of-interaction (DOI) effects. The DOI effect diminished the depth resolution by approximately 2 mm. Increasing the slant angle range from {+-}30{degrees} to {+-}45{degrees} resulted in an approximately 1 mm improvement in the depth resolution. In the breast phantom images, VASH showed improved contrast and SNR over conventional SPECT and improved contrast over planar scintimmammography. Reconstructed images from the proof-of-concept VASH collimator demonstrated reasonable depth resolution capabilities using limited angle projection data. Conclusion: We conclude that this limited angle SPECT approach using a VASH collimator can achieve superior 3D image quality for MBI in a design that has attractive characteristics for clinical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Blockchain based Communication Architectures with Applications to Private Security Networks

Existing communication protocols in high consequence security networks are highly centralized. While this naively makes the controls easier to physically secure, external actors require fewer resources to disrupt the system because there are fewer points in the system can be destroyed or interrupted without the entire system failing. We present a solution to this problem using a proof-of-work-based blockchain implementation built on MultiChain. We construct a test-bed network containing two types of data input: visual imagers and microwave sensor information. These data types are ubiquitous in perimeter intrusion detection security systems and allow a realistic representation of a real-world network architecture. The cameras in this system use an object detection algorithm to nd important targets in the scene. The raw data from the camera and the outputs from the detection algorithm are then placed in a transaction on the distributed ledger. Similarly, microwave data is used to detect relevant events and are placed in a transaction. These transactions are then bundled into blocks and broadcast to the rest of the network using the Bitcoin-based MultiChain protocol. We develop five tests to examine the security metrics of our network. We performed the five security metric test using different sized networks from 7 to 39 nodes to determine how the metrics scale with respect to size. We nd that when compared to a centralized architecture our implementation provides a resiliency increase that is expected from a blockchain-based protocol without slowing the system so much that a human operator would notice. Furthermore, our approach is able to detect tampering in real time. Based on these results, we theorize that security networks in general could use a blockchain-based approach in a meaningful way.

97 MATHEMATICS AND COMPUTING↗

The Use of Gamma-Ray Imaging to Improve Portal Monitor Performance

We have constructed a prototype, rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. Our Roadside Tracker uses automated target acquisition and tracking (TAT) software to identify and track vehicles in visible light images. The field of view of the visible camera overlaps with and is calibrated to that of a one-dimensional gamma-ray imager. The TAT code passes information on when vehicles enter and exit the system field of view and when they cross gamma-ray pixel boundaries. Based on this in-formation, the gamma-ray imager "harvests" the gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. In this fashion we are able to generate vehicle-specific radiation signatures and avoid source confusion problems that plague nonimaging approaches to the same problem.

Ziock, Klaus-Peter↗

Standardized and Cost-Effective Benthic Habitat Mapping Tools for Marine and Hydrokinetic Site Environmental Assessments

A variety of techniques have been used for baseline benthic habitat characterization and monitoring at marine and hydrokinetic (MHK) sites. A lack of standardization has led to expensive efforts that can be confusing for regulators and stakeholders evaluating these sites. Benthic habitat maps have traditionally been developed from a suite of geophysical data, including ultibeam echosounder (MBES) bathymetry and backscatter, side scan sonar, imagery from deployed camera systems, and/or sediment sample chemical and biological data. Integral is developing a computer vision (CV) system for automating the measurement of key physical and biological features in sediment profile image (SPI) and seafloor plan view (PV) imagery so that image-derived data can be efficiently integrated with other data sets to create standardized benthic habitat maps at MHK facilities.

16 TIDAL AND WAVE POWER↗

Combining Image and Non-Image Data for Automatic Detection of Retina Disease in a Telemedicine Network

A telemedicine network with retina cameras and automated quality control, physiological feature location, and lesion/anomaly detection is a low-cost way of achieving broad-based screening for diabetic retinopathy (DR) and other eye diseases. In the process of a routine eye-screening examination, other non-image data is often available which may be useful in automated diagnosis of disease. In this work, we report on the results of combining this non-image data with image data, using the protocol and processing steps of a prototype system for automated disease diagnosis of retina examinations from a telemedicine network. The system includes quality assessments, automated physiology detection, and automated lesion detection to create an archive of known cases. Non-image data such as diabetes onset date and hemoglobin A1c (HgA1c) for each patient examination are included as well, and the system is used to create a content-based image retrieval engine capable of automated diagnosis of disease into 'normal' and 'abnormal' categories. The system achieves a sensitivity and specificity of 91.2% and 71.6% using hold-one-out validation testing.

59 BASIC BIOLOGICAL SCIENCES↗

NGEE Arctic Webcam Photographs, Barrow Environmental Observatory, Utqiagvik (Barrow), Alaska, 2012 - 2015

The NGEE-Arctic Webcam (PTZ Camera) captures two views of seasonal transitions from its generally south-facing position on a tower located at the Barrow Environmental Observatory near Utqiagvik (Barrow), Alaska. Images are captured every 30 minutes and available as *.jpeg files. The camera is operated by the U.S. DOE sponsored Next Generation Ecosystem Experiments - Arctic (NGEE-Arctic) project and credit also to Larry Hinzman. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Gamma imaging and mapping advancements

The Savannah River National Lab (SRNL) in partnership with Los Alamos National Lab (LANL) developed an in-situ GrayQb™ radiation mapping device eliminating the need to remove the radiation sensitive phosphor storage plate (PSP) from the device for scanning between exposures. By incorporating a customized version of the LANL patented MiniMax camera-based PSP reader system into the GrayQb™ housing, the exposed PSP can now be read in-situ and digitally transmitted to a remote computer for viewing. The ability to generate radiation contour maps showing source locations and relative radiological levels present in an area has high utility for targeting clean-up efforts, maintaining worker ALARA, determining leak locations and radiological situational awareness. In-situ GrayQb™ reduces the number of required interactions with the device providing deployment cost savings, increasing personnel safety and removing human handling errors during the manual scan process. Additionally, by negating the need for an external scanner, the device becomes more mobile. Other upgrades to the device included identification of a more sensitive imaging medium and incorporation of a dual pinhole rendering the device physically capable of obtaining 3D images. Laboratory tests with Am-241 sources using a mockup of the in-situ GrayQ™, successfully demonstrated the ability to digitally capture radiation source information using the dual pinhole and camera-based PSP reader.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-C-17A-03: Dynamic Visualization and Dosimetry of IMRT and VMAT Treatment Plans by Video-Rate Imaging of Cherenkov Radiation in Pure Water

Purpose: A novel optical dosimetry technique for the QA and verification of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) radiotherapy plans was investigated for the first time by capturing images of the induced Cherenkov radiation in water. Methods: An intensified CCD camera (ICCD) was used to acquire a two-dimensional (2D) projection image of the Cherenkov radiation induced by IMRT and VMAT plans, based on the Task Group 119 C-Shape geometry. Plans were generated using the Varian Eclipse treatment planning system (TPS) and delivered using 6 MV x-rays from a Varian TrueBeam Linear Accelerator (Linac) incident on a water tank. The ICCD acquisition was gated to the Linac, operated for single pulse imaging, and binned to a resolution of 512×512 pixels. The resulting videos were analyzed temporally for regions of interest (ROI) covering the planning target volume (PTV) and organ at risk (OAR) and summed to obtain an overall light distribution, which was compared to the expected dose distribution from the TPS using a gammaindex analysis. Results: The chosen camera settings resulted in data at 23.5 frames per second. Temporal intensity plots of the PTV and OAR ROIs confirmed the preferential delivery of dose to the PTV versus the OAR, and the gamma analysis yielded 95.2% and 95.6% agreement between the light distribution and expected TPS dose distribution based upon a 3% / 3 mm dose difference and distance-to-agreement criterion for the IMRT and VMAT plans respectively. Conclusion: The results from this initial study demonstrate the first documented use of Cherenkov radiation for optical dosimetry of dynamic IMRT and VMAT treatment plans. The proposed modality has several potential advantages over alternative methods including the real-time nature of the acquisition, and upon future refinement may prove to be a robust and novel dosimetry method with both research and clinical applications. NIH R01CA109558 and R21EB017559.

07 ISOTOPE AND RADIATION SOURCES↗

Computer-aided classification of suspicious pigmented lesions using wide-field images

Early identification of melanoma is conducted through whole-body visual examinations to detect suspicious pigmented lesions, a situation that fluctuates in accuracy depending on the experience and time of the examiner. Computer-aided diagnosis tools for skin lesions are typically trained using pre-selected single-lesion images, taken under controlled conditions, which limits their use in wide-field scenes. Here, we propose a computer-aided classifier system with such input conditions to aid in the rapid identification of suspicious pigmented lesions at the primary care level. 133 patients with a multitude of skin lesions were recruited for this study. All lesions were examined by a board-certified dermatologist and classified into “suspicious” and “non-suspicious”. A new clinical database was acquired and created by taking Wide-Field images of all major body parts with a consumer-grade camera under natural illumination condition and with a consistent source of image variability. 3–8 images were acquired per patient on different sites of the body, and a total of 1759 pigmented lesions were extracted. A machine learning classifier was optimized and build into a computer aided classification system to binary classify each lesion using a suspiciousness score. In a testing set, our computer-aided classification system achieved a sensitivity of 100% for suspicious pigmented lesions that were later confirmed by dermoscopy examination (“SPL_A”) and 83.2% for suspicious pigmented lesions that were not confirmed after examination (“SPL_B”). Sensitivity for non-suspicious lesions was 72.1%, and accuracy was 75.9%. With these results we defined a suspiciousness score that is aligned with common macro-screening (naked eye) practices. This work demonstrates that wide-field photography combined with computer-aided classification systems can distinguish suspicious from non-suspicious pigmented lesions, and might be effective to assess the severity of a suspicious pigmented lesions. We believe this approach could be useful to support skin screenings at a population-level.

60 APPLIED LIFE SCIENCES↗

The Bimodal Absorption System Imaging Campaign (BASIC). I. A Dual Population of Low-metallicity Absorbers at z < 1

The bimodal absorption system imaging campaign (BASIC) aims to characterize the galaxy environments of a sample of 36 H I-selected partial Lyman limit systems (pLLSs) and Lyman limit systems (LLSs) in 23 QSO fields at z ≲ 1. These pLLSs/LLSs provide a unique sample of absorbers with unbiased and well-constrained metallicities, allowing us to explore the origins of metal-rich and low-metallicity circumgalactic medium (CGM) at z < 1. Here we present Keck/KCWI and Very Large Telescope/MUSE observations of 11 of these QSO fields (19 pLLSs) that we combine with Hubble Space Telescope/Advanced Camera for Surveys imaging to identify and characterize the absorber-associated galaxies at 0.16 ≲ z ≲ 0.84. We find 23 unique absorber-associated galaxies, with an average of one associated galaxy per absorber. For seven absorbers, all with <10% solar metallicities, we find no associated galaxies with logM * ≳ 9.0 within ρ/R vir and |Δv|/v esc ≤ 1.5 with respect to the absorber. We do not find any strong correlations between the metallicities or H I column densities of the gas and most of the galaxy properties, except for the stellar mass of the galaxies: the low-metallicity ([X/H] ≤ –1.4) systems have a probability of $0.39_{–0.15}^{+0.16}$ for having a host galaxy with logM * ≥ 9.0 within ρ/R vir ≤ 1.5, while the higher metallicity absorbers have a probability of $0.78_{–0.13}^{+0.10}$. This implies metal-enriched pLLSs/LLSs at z < 1 are typically associated with the CGM of galaxies with logM * > 9.0, whereas low-metallicity pLLSs/LLSs are found in more diverse locations, with one population arising in the CGM of galaxies and another more broadly distributed in overdense regions of the universe. Using absorbers not associated with galaxies, we estimate the unweighted geometric mean metallicity of the intergalactic medium to be [X/H] ≲ –2.1 at z < 1, which is lower than previously estimated.

79 ASTRONOMY AND ASTROPHYSICS↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 09: Impact of the distance of reflective markers from linac isocenter on the positional accuracy of an infrared tracking system

Purpose: The HexaPOD™ six degree of freedom couchtop is equipped with an optical tracking system, consisting of a stereoscopic camera and a reference frame (RF) carrying infrared reflective markers. The manufacturer recommends placing the RF within 50 cm from linac isocenter (ISO), which is a serious limitation since the RF does not fit around the shoulders of most brain patients. This study quantifies the impact of extended RF distances from ISO on positional accuracy. Methods: An in-house tool with an estimated resolution of 0.3 mm and 0.1° was used. It is a large cube and a mathematical model of HexaPOD motion to determine the intersection of room lasers with the ruled cube edges. Combinations of translations (±1 and ±3 cm) and rotations (±2.5°) were executed on two HexaPOD couchtops for multiple RF distances from ISO (35 to 77 cm). For each combination, ten laser readings were fed into a least squares algorithm to determine the executed translations and rotations while minimizing operator reading errors. Results: The usable tracking volume is up to an RF distance of 82 cm from ISO. Positional accuracy of the HexaPOD/iGuide system is 0.6 mm and 0.1° (95% confidence). Positional accuracy variations versus RF distance from ISO are statistically insignificant (p = 0.05). Our results generally confirm recent internal estimates by the manufacturer (for future release). Conclusions: RF distances up to 77 cm from ISO are clinically acceptable, provided performing a patient safety study with a verification scan.

60 APPLIED LIFE SCIENCES↗