Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-F-I-15: Evaluation of a New MR-Compatible Respiratory Motion Device at 3T

Purpose: Recent advances in MRI-guided radiotherapy has inspired the development of MRI-compatible motion devices that simulate patient periodic motion in the scanner, particularly respiratory motion. Most commercial devices rely on non MR-safe ferromagnetic stepper motors which are not practical for regular QA testing. This work evaluates the motion performance of a new fully MRI compatible respiratory motion device at 3T. Methods: The QUASAR™ MRI-compatible respiratory motion phantom has been recently developed by Modus QA Inc., London, ON, Canada. The prototype is constructed from diamagnetic materials with linear motion generated using MRI-compatible piezoelectric motors that can be safely inserted in the scanner bore. The tumor was represented by a fillable sphere and is attached to the linear motion generator. The spherical tumor-representative and its surroundings were filled with different concentrations of MnCl2 to produce realistic relaxation times. The motion was generated along the longitudinal (H/F) axis of the bore using sinusoidal reference waveform (amplitude = 15 mm, frequency 0.25 Hz). Imaging was then performed on 3T Philips Achieva using a 32-channel cardiac coil. Fast 2D spoiled gradient-echo was used with a spatial resolution of 1.8 × 1.8 mm{sup 2} and slice thickness of 4 mm. The motion waveform was then measured on the resultant image series by tracking the centroid of the sphere through the time series. This image-derived measured motion was compared to the software-generated reference waveform. Results: No visible distortions from the device were observed on the images. Excellent agreement between the measured and the reference waveforms were obtained. Negligible motion was observed in the lateral (R/L) direction. Conclusion: Our investigation demonstrates that this piezo-electric motor design is effective at simulating periodic motion and is a potential candidate for MRI-radiotherapy respiratory motion simulation. Future work should focus on evaluating non-sinusoidal waveforms, fast 3D pulse sequences, and perform dosimetric QA.

60 APPLIED LIFE SCIENCES↗

Design of AlGaN-Zn(Si,Ge)N2 quantum wells for high-efficiency ultraviolet light emitters

The effect of inserting a nm-scale layer of Zn(Si,Ge)N2 into an AlGaN quantum well structure designed for light emission in the wavelength range from 255 to 305 nm is investigated here. The enhanced confinement of the hole within the quantum well results in an enhancement of the overlap of the hole and electron wave functions, resulting in an enhancement of the radiative recombination rate. In this theoretical calculation, for emission at a 270 nm wavelength, the enhancement in the wavefunction overlap can reach a factor of 7 when compared to an AlGaN quantum well device specifically engineered for optimal emission at the identical wavelength. Increases of almost an order of magnitude in both the peak spontaneous emission intensity and the radiative recombination rate are predicted. The peak emission wavelength can be tuned from 255 to 305 nm by adjusting the width and/or the composition of the inserted layer. The proposed structures provide a route to higher efficiency ultraviolet practical light emitting diodes and lasers.

Physics↗

Electroactive ZnO: Mechanisms, Conductivity, and Advances in Zn Alkaline Battery Cycling

Zinc oxide is of great interest for advanced energy devices because of its low cost, wide direct bandgap, non-toxicity, and facile electrochemistry. In zinc alkaline batteries, ZnO plays a critical role in electrode passivation, a process that hinders commercialization and remains poorly understood. Here, novel observations of an electroactive type of ZnO formed in Zn-metal alkaline electrodes are disclosed. The electrical conductivity of battery-formed ZnO is measured and found to vary by factors of up to 10 4 , which provides a first-principles-based understanding of Zn passivation in industrial alkaline batteries. Simultaneous with this conductivity change, protons are inserted into the crystal structure and electrons are inserted into the conduction band in quantities up to ≈10 20 cm –3 and ≈1 mAh gZnO –1 . Electron insertion causes blue electrochromic coloration with efficiencies and rates competitive with leading electrochromic materials. The electroactivity of ZnO is evidently enabled by rapid crystal growth, which forms defects that complex with inserted cations, charge-balanced by the increase of conduction band electrons. Furthermore, this property distinguishes electroactive ZnO from inactive classical ZnO. Knowledge of this phenomenon is applied to improve cycling performance of industrial-design electrodes at 50% zinc utilization and the authors propose other uses for ZnO such as electrochromic devices.

36 MATERIALS SCIENCE↗

Manned NEO Mission EVA Challenges

The President has proposed to land astronauts on an asteroid by 2025. However, Manned NEO (Near Earth Objects) Missions will present a host of new and exciting problems that will need to be better defined and solved before such a mission is launched. Here I will focus on the challenges for conducting asteroidal EVAs. Specfically, crew locomotion, sampling, drilling, documentation, and instrument deployment issues arising from the micro gravity environments associated with NEOs. Therefore, novel methods and techniques will need to be developed and tested in order to achieve specific mission science objectives. Walking or driving on the surface will not be a realistic option due to the small sizes (10 s to 100 s of meters in diameter) and hence extremely low gravity of the present day known candidate NEOs. EVAs will have to be carried out with crew members either using a self propelled device (akin to the MMU and SAFER units used on Shuttle/ISS) and or tethers. When using tethers a grid system could be deployed which is anchored to the asteroid. These anchor points could be inserted by firing penetrators into the surface from the spacecraft while it is still at a safe standoff distance. These penetrators would pull double duty by being laden with scientific instrumentation to probe the subsurface. Dust and debris generated by sample collection and locomotion in a microgravity environment could also pose some problems that will require forethought.

Source record↗

Total Percutaneous Aortic Repair: Midterm Outcomes

The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 {+-} 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 {+-} 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of ultrasound elevation beamwidth artifacts for prostate brachytherapy needle insertion

Purpose: Ultrasound elevation beamwidth leads to image artifacts and uncertainties in localizing objects (such as a surgical needle) in ultrasound images. The authors examined the clinical significance of errors caused by elevation beamwidth artifacts and imaging parameters in needle insertion procedures. Methods: Beveled prostate brachytherapy needles were inserted through all holes of a grid template under real-time transrectal ultrasound (TRUS) guidance. The needle tip position as indicated by the TRUS image was compared to their observed physical location. A new device was developed to measure the ultrasound elevation beamwidth. Results: Imaging parameters of the TRUS scanner have direct impact on the localization error ranging from 0.5 up to 4 mm. The smallest localization error was observed laterally close to the center of the grid template and axially within the beam's focal zone. Largest localization error occurs laterally around both sides of the grid template and axially within the beam's far field. The authors also found that the localization errors vary with both lateral and elevation offsets. Conclusions: The authors found properly adjusting the TRUS imaging settings to lower the ultrasound gain and power effectively minimized the appearance of elevation beamwidth artifacts and in turn reduced the localization errors of the needle tip.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tool removes brazed fittings

Device, which removes fittings from thin-walled tubing, will not accidentally bond to fitting, nor will it cause tube wall to melt. Key feature is the use of expendable split-ring heat sink insert. Technique is applicable to fitting stubs of all sizes and wall thicknesses.

Hurley, W. J.↗

SQUID-Detected MRI in the Limit of Zero Static Field

This thesis describes an implementation of the so-called"zero-field MRI" (ZFMRI) pulse sequence, which allows for imaging in an arbitrarily low B 0 field. The ZFMRI sequence created an effective unidirectional gradient field by using a train of pi pulses to average out the concomitant gradient components during encoding. The signals were acquired using a low-transition temperature dc Superconducting QUantum Interference Device (low-Tc dc SQUID) coupled to a first-order axial gradiometer. The experiments were carried out in a liquid helium dewar which was magnetically shielded with a single-layer mu-metal can around the outside and a superconducting Pb can contained within the helium space. We increased the filling factor of the custom-made, double-walled Pyrex insert by placing the liquid alcohol sample, at a temperature of approximately -50 degrees C, at the center of one loop of the superconducting gradiometer, which was immersed in the helium bath.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tuning Photovoltaic Performance of Perovskite Nickelates Heterostructures by Changing the A-Site Rare-Earth Element

Perovskite rare-earth nickelates (RNiO3) have attracted much attention because of their exotic physical properties and rich potential applications. Here, we report systematic tuning of the electronic structures of RNiO3 (R=Nd, Sm, Gd, and Lu) by isovalent A-site substitution. By integrating RNiO3 thin films with Nb-doped SrTiO3 (NSTO), p-n heterojunction photovoltaic cells have been prepared and their performance has been investigated. The open-circuit voltage increases monotonically with decreasing A-site cation radius of RNiO3. This change results in a downward shift of the Fermi level and induces the increase in the built-in potential at the RNiO3/NSTO heterojunction, with LuNiO3/NSTO showing the largest open-circuit voltage. At the same time, the short-circuit current initially increases upon changing the A-site element from Nd to Sm. However, the larger bandgaps of GdNiO3 and LuNiO3 reduces light absorption which in turn induces a decrease in the short-circuit current. A power conversion efficiency of 1.13% has been achieved by inserting an ultrathin insulating SrTiO3 layer at the SmNiO3/NSTO interface. Our study illustrates how changing the A-site cation is an effective strategy for tuning photovoltaic performance and increasing the applicability of nickelates in optoelectric devices.

Nickelates, Oxygen vacancy, photovoltaics, p-n het↗

A novel approach to interface high-Q Fabry–Pérot resonators with photonic circuits

The unique benefits of Fabry–Pérot resonators as frequency-stable reference cavities and as an efficient interface between atoms and photons make them an indispensable resource for emerging photonic technologies. To bring these performance benefits to next-generation communications, computation, and time-keeping systems, it will be necessary to develop strategies to integrate compact Fabry–Pérot resonators with photonic integrated circuits. In this paper, we demonstrate a novel reflection cancellation circuit that utilizes a numerically optimized multi-port polarization-splitting grating coupler to efficiently interface high-finesse Fabry–Pérot resonators with a silicon photonic circuit. This circuit interface produces a spatial separation of the incident and reflected waves, as required for on-chip Pound–Drever–Hall frequency locking, while also suppressing unwanted back reflections from the Fabry–Pérot resonator. Using inverse design principles, we design and fabricate a polarization-splitting grating coupler that achieves 55% coupling efficiency. This design realizes an insertion loss of 5.8 dB for the circuit interface and more than 9 dB of back reflection suppression, and we demonstrate the versatility of this system by using it to interface several reflective off-chip devices.

Optics↗

Leveraging continuous material averaging for inverse electromagnetic design

Inverse electromagnetic design has emerged as a way of efficiently designing active and passive electromagnetic devices. This maturing strategy involves optimizing the shape or topology of a device in order to improve a figure of merit-a process which typically requires that we compute the gradient of a figure of merit which describes device performance, potentially with respect to many design variables. In this paper, we introduce a new strategy based on smoothing abrupt material interfaces which enables us to efficiently compute these gradients with high accuracy irrespective of the resolution of the underlying simulation. This has advantages over previous approaches to shape and topology optimization in nanophotonics which are either prone to gradient errors or place important constraints on the shape of the device. As a demonstration of this new strategy, we optimize a non-adiabatic waveguide taper between a narrow and wide waveguide. Finally, this optimization leads to a non-intuitive design with a very low insertion loss of only 0.041 dB at 1550 nm.

36 MATERIALS SCIENCE↗

2D material platform for overcoming the amplitude–phase tradeoff in ring resonators

Compact and high-speed electro-optic phase modulators play a vital role in various large-scale applications including optical computing, quantum and neural networks, and optical communication links. Conventional electro-refractive phase modulators such as silicon (Si), III-V and graphene on Si suffer from a fundamental tradeoff between device length and optical loss that limits their scaling capabilities. High-finesse ring resonators have been traditionally used as compact intensity modulators, but their use for phase modulation has been limited due to the high insertion loss associated with the phase shift. Here, we show that high-finesse resonators can achieve a strong phase shift with low insertion loss by simultaneous modulation of the real and imaginary parts of the refractive index, to the same extent, i.e., Δ n Δ k ∼1. To implement this strategy, we demonstrate an active hybrid platform that combines a low-loss SiN ring resonator with 2D materials such as graphene and transition metal dichalcogenide [tungsten disulphide (WSe 2 )], which induces a strong change in the imaginary and real parts of the index. Our platform consisting of a 25 µm long Gr-Al 2 O 3 -WSe 2 capacitor embedded on a SiN ring of 50 µm radius (∼8% ring coverage) achieves a continuous phase shift of (0.46±0.05) π radians with an insertion loss (IL) of 3.18±0.20 dB and a transmission modulation (Δ T Ring ) of 1.72±0.15dB at a probe wavelength ( λ p ) of 1646.18 nm. We find that our Gr-Al 2 O 3 -WSe 2 capacitor exhibits a phase modulation efficiency ( V π 2 ⋅ L ) of 0.530±0.016V⋅cm and can support an electro-optic bandwidth of 14.9±0.1GHz. We further show that our platform can achieve a phase shift of π radians with an IL of 5 dB and a minimum Δ T of 0.046 dB. We demonstrate the broadband nature of the binary phase response, by measuring a phase shift of (1.00±0.10) π radians, with an IL of 5.20±0.31dB and a minimal Δ T Ring of 0.015±0.006dB for resonances spanning from 1564 to 1650 nm. This SiN–2D hybrid platform provides the design for compact and high-speed reconfigurable circuits with graphene and transition metal dichalcogenide (TMD) monolayers that can enable large-scale photonic systems.

Datta, Ipshita (ORCID:0000000318842882)↗

Damping of thermal acoustic oscillations in hydrogen systems

Acoustic waves initiated by a large temperature gradient along a tube are defined as thermal acoustic oscillations (TAOs). These oscillations have been damped by introducing such sound absorbing techniques as acoustic filters, resonators, etc.. These devices serve as an acoustic sink that is used to absorb or dissipate the acoustic energy thereby eliminating or damping such oscillations. Several empirical damping techniques, such as attaching a resonator as a side branch or inserting a wire in the tube, have been developed in the past and have provided reasonable success. However, the effect of connecting tube radius, length, and resonator volume on the damping of thermal acoustic oscillations has not been evaluated quantitatively. Further, these methods have not been effective when the oscillating tube radius was relatively large. Detailed theoretical analyses of these techniques including a newly developed method for damping oscillations in a tube of relatively large radius are provided in this presentation.

Gu, Youfan↗

Determination of lifetime and surface recombination velocity of p-n junction solar cells and diodes by observing transients

The unified view of transient methods for the determination of recombination lifetime tau and back surface recombination velocity S presented here for silicon solar cells and diodes attempts to define limitations of existing methods and to evolve improvements. The presence of sizable junction capacitance for silicon devices under forward voltage invalidates the use of conventional open-circuit voltage decay (OCVD) and reverse recovery. This led Green (1983) to his method of compensated open-circuit voltage decay, in which the addition of an external resistor shunting the solar cell partially corrects for the presence of the junction capacitance. Setting this resistance to zero produces an electrical short-circuit current-decay method, which has the advantage of enabling determination of both tau and S. In an alternate approach, one may insert the functional dependence of the junction capacitance on forward voltage. This new method, denoted by the acronym OCVDCAP, enables the determination of tau with apparently greater accuracy than that obtained by previous methods utilizing voltage transients. But OCVDCAP has in common with the previous methods that it determines tau only and has practical utility only for determining tau of long-base devices. This means that it is useful only for thick base regions. In principle, however, it has an advantage over short-circuit current decay: it requires only pressure contacts, not ohmic contacts, and therefore may be used to determine tau after key processing steps in manufacturing.

Lindholm, Fredrik A.↗

Results from a new flowing liquid Li limiter with TZM substrate during high confinement plasmas in the EAST device

A third generation flowing liquid lithium (FLiLi) limiter with a substrate made of TZM, an alloy with >99% Mo, was fabricated by conventional manufacturing techniques. TZM has a high corrosion resistance, a high sputtering threshold, and a good wettability to Li, as compared to stainless steel (SS), which had been used as an FLiLi substrate surface in 2014 and 2016. The third generation FLiLi was inserted into the edge in EAST H-mode plasmas in an upper single-null configuration with an ion grad-B drift toward the upper divertor with a limiter temperature of 330–380 °C and an auxiliary heating power of about 2–8 MW. Analysis has shown that by using TZM FLiLi, fuel particle recycling continuously decreased and near-complete edge localized mode elimination was achieved in H-mode plasmas with RF-only heating. The main impurities during the initial FLiLi discharges were Mo, Fe, and W resulting from strong plasma interaction at the Mo plate side, the SS collector, and the upper W divertor. Plasma stored energy increased by about 10 kJ in subsequent FLiLi discharges due to decreased impurity radiation. Engineering analysis shows a uniform lithium flow with an ~80% Li coverage ratio on the limiter surface, similar to the second FLiLi, even though only one of two J × B pumps was functioning. Despite technical difficulties, the FLiLi gen.3 improved the overall plasma performance, providing support for flowing liquid Li plasma facing component applications in present and future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral gap of shear Alfven waves in a periodic array of magnetic mirrors

A multiple magnetic mirror array is formed at the Large Plasma Device (LAPD) [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)] to study axial periodicity-influenced Alfven spectra. Shear Alfven waves (SAW) are launched by antennas inserted in the LAPD plasma and diagnosed by B-dot probes at many axial locations. Alfven wave spectral gaps and continua are formed similar to wave propagation in other periodic media due to the Bragg effect. The measured width of the propagation gap increases with the modulation amplitude as predicted by the solutions to Mathieu's equation. A two-dimensional finite-difference code modeling SAW in a mirror array configuration shows similar spectral features. Machine end-reflection conditions and damping mechanisms including electron-ion Coulomb collision and electron Landau damping are important for simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary design report, Large Space Telescope OTA/SI Phase B study: High speed area photometer

A photometer is examined which combines several features from separate instruments into a single package. The design presented has both point and area photometry capability with provision for inserting filters to provide spectral discrimination. The electronics provide for photon counting mode for the point detectors and both photon counting and analog modes for the area detector. The area detector also serves as a target locating device for the point detectors. Topics discussed include: (1) electronic equipment requirements, (2) optical properties, (3) structural housing for the instrument, (4) motors and other mechanical components, (5) ground support equipment, and (6) environment control for the instrument. Engineering drawings and block diagrams are shown.

Source record↗

SU-F-T-668: Irradiating Mouse Brain with a Clinical Linear Accelerator

Purpose: To design and construct a “mouse jig” device that would allow for irradiation of the mouse brain with a clinical Varian 6 MeV Linear Accelerator. This device must serve as a head immobilizer, gaseous anesthesia delivery, and radiation bolus concurrently. Methods: The mouse jig was machined out of nylon given that it is inexpensive, easy to machine, and has similar electron density to water. A cylindrical opening with diameter of 16 mm and 40 mm depth was drilled into a nylon block sized 56×56×50 mm (width, length, depth). Additional slots were included in the block for ear bars and a tooth bar to serve as a three-point immobilization device as well as for anesthesia delivery and scavenging. For ease of access when loading the mouse into the holder, there is a removable piece at the top of the block that is 15 mm in depth. This serves a dual purpose, as with the proper extra shielding, the mouse jig could be used with lower linear energy transfer photons with this piece removed. A baseplate was then constructed with five square slots where the mouse jig can securely be inserted plus additional slots that would allow the baseplate to be mounted on a standard lock bar in the treatment couch. This maximizes the reproducibility of placement between imaging and treatment and between treatment sessions. Results: CT imaging and radiation treatment planning was performed that showed acceptable coverage and uniformity of radiation dose in the mouse brain while sparing the throat and eyes. Conclusion: We have designed and manufactured a device that fulfills our criteria allowing us to selectively irradiate the mouse brain with a clinical linear accelerator. This setup will be used for generating mouse models of radiation-induced brain injury.

60 APPLIED LIFE SCIENCES↗