Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of the effects of cell model and subcellular location of gold nanoparticles on nuclear dose enhancement factors using Monte Carlo simulation

Purpose: The authors’ aims were to model how various factors influence radiation dose enhancement by gold nanoparticles (AuNPs) and to propose a new modeling approach to the dose enhancement factor (DEF).Methods: The authors used Monte Carlo N-particle (MCNP 5) computer code to simulate photon and electron transport in cells. The authors modeled human breast cancer cells as a single cell, a monolayer, or a cluster of cells. Different numbers of 5, 30, or 50 nm AuNPs were placed in the extracellular space, on the cell surface, in the cytoplasm, or in the nucleus. Photon sources examined in the simulation included nine monoenergetic x-rays (10–100 keV), an x-ray beam (100 kVp), and {sup 125}I and {sup 103}Pd brachytherapy seeds. Both nuclear and cellular dose enhancement factors (NDEFs, CDEFs) were calculated. The ability of these metrics to predict the experimental DEF based on the clonogenic survival of MDA-MB-361 human breast cancer cells exposed to AuNPs and x-rays were compared.Results: NDEFs show a strong dependence on photon energies with peaks at 15, 30/40, and 90 keV. Cell model and subcellular location of AuNPs influence the peak position and value of NDEF. NDEFs decrease in the order of AuNPs in the nucleus, cytoplasm, cell membrane, and extracellular space. NDEFs also decrease in the order of AuNPs in a cell cluster, monolayer, and single cell if the photon energy is larger than 20 keV. NDEFs depend linearly on the number of AuNPs per cell. Similar trends were observed for CDEFs. NDEFs using the monolayer cell model were more predictive than either single cell or cluster cell models of the DEFs experimentally derived from the clonogenic survival of cells cultured as a monolayer. The amount of AuNPs required to double the prescribed dose in terms of mg Au/g tissue decreases as the size of AuNPs increases, especially when AuNPs are in the nucleus and the cytoplasm. For 40 keV x-rays and a cluster of cells, to double the prescribed x-ray dose (NDEF = 2) using 30 nm AuNPs, would require 5.1 ± 0.2, 9 ± 1, 10 ± 1, 10 ± 1 mg Au/g tissue in the nucleus, in the cytoplasm, on the cell surface, or in the extracellular space, respectively. Using 50 nm AuNPs, the required amount decreases to 3.1 ± 0.3, 8 ± 1, 9 ± 1, 9 ± 1 mg Au/g tissue, respectively.Conclusions: NDEF is a new metric that can predict the radiation enhancement of AuNPs for various experimental conditions. Cell model, the subcellular location and size of AuNPs, and the number of AuNPs per cell, as well as the x-ray photon energy all have effects on NDEFs. Larger AuNPs in the nucleus of cluster cells exposed to x-rays of 15 or 40 keV maximize NDEFs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of the Alfvén Oscillation Location in the TUMAN-3M Tokamak Plasma

The Alfvén oscillations have been studied in ohmically heated deuterium discharges with LH-transition in the TUMAN-3M tokamak in order to clarify their location in a plasma column. The Alfvén oscillation location was determined by comparison of the oscillation frequency measured with magnetic probes and that calculated from local density assuming the typical dispersion relation for Alfvén waves f = (2π){sup −1}k{sub ||}v{sub A}, where v{sub A} is the Alfvén velocity and k{sub ||} is the the parallel wave number in the direction of the magnetic field. It was found that they are localized in central part of plasma column inside r/a < 0.5 region. Candidate sets of mode numbers have been determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data-Driven Protection Software to classify fault locations by protective zone in distribution systems with high PV penetration

The software contains (a) the source codes to generate Point-on-Wave (PoW) transient data for any feeder model in Alternative Transient Program (ATP) format. Codes provide options to change different steady state settings, including the loading condition and PV capacity and transient state setting like faults type, location and initiation time (b) data post-processing source code to converted data from native format to COMTRADE, csv, HDF5 (c) Docker container to train CNN to classify fault locations by protective zone. The container takes dataset and other training parameters (sampling rate, training epochs, batch size etc) as input to train CNN. The container writes back the trained CNN model, training and testing metrics and plots to the local workstation

Ramesh, Meghana↗

Automatic Traffic Queue-End Identification using Location-Based Waze User Reports

Traffic queues, especially queues caused by non-recurrent events such as incidents, are unexpected to high-speed drivers approaching the end of queue (EOQ) and become safety concerns. Though the topic has been extensively studied, the identification of EOQ has been limited by the spatial-temporal resolution of traditional data sources. This study explores the potential of location-based crowdsourced data, specifically Waze user reports. It presents a dynamic clustering algorithm that can group the location-based reports in real time and identify the spatial-temporal extent of congestion as well as the EOQ. The algorithm is a spatial-temporal extension of the density-based spatial clustering of applications with noise (DBSCAN) algorithm for real-time streaming data with an adaptive threshold selection procedure. Here, the proposed method was tested with 34 traffic congestion cases in the Knoxville, Tennessee area of the United States. It is demonstrated that the algorithm can effectively detect spatial-temporal extent of congestion based on Waze report clusters and identify EOQ in real-time. The Waze report-based detection are compared to the detection based on roadside sensor data. The results are promising: The EOQ identification time of Waze is similar to the EOQ detection time of traffic sensor data, with only 1.1 min difference on average. In addition, Waze generates 1.9 EOQ detection points every mile, compared to 1.8 detection points generated by traffic sensor data, suggesting the two data sources are comparable in respect of reporting frequency. The results indicate that Waze is a valuable complementary source for EOQ detection where no traffic sensors are installed.

99 GENERAL AND MISCELLANEOUS↗

Outcome of Primary Desmoid Tumors at All Anatomic Locations Initially Managed with Active Surveillance

Background: The behavior of desmoid tumors is unpredictable and varies from spontaneous remission to symptomatic and radiologic progression. This study aimed to evaluate the radiologic and symptomatic course of the disease in patients initially managed with active surveillance. Methods: Patients with a primary desmoid tumor at any anatomic location diagnosed between 1998 and 2016 were identified in a prospectively maintained database from a single sarcoma reference center in the United Kingdom. Inverse univariate Cox proportional hazard regression analyses were conducted to evaluate the course of the disease and indications for initiating treatment. Results: The study identified 168 patients with a primary desmoid tumor initially managed with active surveillance. The tumors were located in the abdominal wall (n = 61, 36%), an extremity (n = 51, 30%), chest wall (n = 30, 18%), intra-abdominal site (n = 15, 9%), or elsewhere (n = 11, 6%). Of all the patients, 36% experienced radiologic progressive disease, 36% had stable disease, and 27% regressed. The patients younger than 50 years were more likely to progress (p = 0.046), whereas the patients with chest wall or upper-extremity tumors reported significantly more pain (p = 0.01). Eventually, 46% of the patients proceeded to treatment. The median time to start of treatment after initial surveillance was 31 months, whereas the median follow-up time for the patients not receiving any treatment was 40.5 months. The indications for initiation of treatment were pain (32%), progression (31%), or both (13%). Conclusions: Patients with desmoid tumors can be managed with initial active surveillance, although almost half of patients may eventually need treatment. Pain, tumor progression, or both are the most common indications for the initiation of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electric-field enhancement caused by subwavelength-sized particles located on the surface of multilayer dielectric mirrors

A laser pulse impinging on the surface of an optical component can interact with particles, such as contamination debris, to produce a scattered electric field, which, either by itself or combined with the incident laser field, coherently can significantly increase the local field intensity. This effect can be of critical importance as it can reduce the laser-induced–damage threshold of the affected component. In this work, we use a field-propagation code to improve understanding regarding the factors that determine the magnitude and location of the electric-field enhancement for the case of subwavelength-sized particles located on the surface of multilayer dielectric mirrors.

47 OTHER INSTRUMENTATION↗

Seismic Line Location Map Hot Pot Project, Humboldt County, Nevada 2010

Seismic Line Location Map Hot Pot Project, Humboldt County, Nevada 2010. ArcGIS map package containing topographic base map, Township and Range layer, Oski BLM and private leases at time of survey, and locations, with selected shot points, of the five seismic lines.

15 GEOTHERMAL ENERGY↗

Velocity and Turbulence Measurements at Three Locations in the Salish Sea, WA, 2017

This submission contains raw and processed datasets of water velocity and turbulence measurements from 3-day deployments of Deepwater Buoyancy StableMoor buoys carrying acoustic Doppler instrumentation at locations in Rosario Strait, Bellingham Channel, and Tacoma Narrows, WA in 2017. Two StableMoor buoy configurations were used at these sites. The StableMoor500 carried a nose-mounted acoustic doppler velocimeter (ADV) and a down-looking acoustic doppler current profiler (ADCP), and the StableMoor400 carried dual wing-mounted ADVs located on either side of the nose and a down-looking ADCP. Each StableMoor was designed to fly at an altitude of 10 m above the seafloor. The StableMoor500 was deployed in Bellingham Channel at 48.5601 N, 122.7501 W in 86 m of water from July 24, 2017 - July 27, 2017. The down-looking ADCP malfunctioned, and therefore there is no ADCP data at this site. The StableMoor400 was deployed in Rosario Strait mooring at 48.5800 N, 122.6597 W in 52 m of water from July 24, 2017 - July 27, 2017. Both buoys were deployed in Tacoma Narrows at 47.2766 N, 122.5466 W and 47.2769 N, 122.5471 W in 36 m of water from Nov 14, 2017 - Nov 17, 2017. Nortek Vector ADV measurements were recorded continuously at 16 Hz. Data was motion-corrected using the internal measurement unit (IMU) and external ADCP bottom-track data, bin-averaged into 10 minute bins, and then converted to the Principal (streamwise, cross-stream, vertical) coordinate system. Parameters include water velocity, turbulence intensity, turbulent kinetic energy (TKE) components, Reynolds shear stress components, TKE dissipation and production. Teledyne RDI Workhorse 1200 kHz ADCP measurements were recorded continuously at 2 Hz with bottom-track enabled. Water velocity was averaged into 10 minute bins and converted into the Principal coordinate system. One ADV with the highest quality motion-corrected was fully processed from each deployment site: the nose-mounted ADV at Bellingham Channel, the starboard-wing mounted ADV at Rosario Strait, and the port-wing mounted ADV at Tacoma Narrows. Raw data stored in this submission can be read using DOLfYN v1.3.1, available through the MHKiT python package, and was processed using Tsdat v0.7.5. Processed data are stored in netCDF4 format and can be easily viewed using the Linux "ncdump" command or read through the Xarray python package.

16 TIDAL AND WAVE POWER↗

Depth-resolved seasonal porewater chemistry measurements from 3 locations around Meander A of the East River, Colorado.

Depth-resolved pore water samples were recovered from 3 locations around Meander A in the East River near Crested Butte, CO, USA for a suite of physiochemical analyses. Supplemental_Information.csv contains water quality measurements including pH, conductivity, temperature, ORP, TDS, O2 concentration, metal concentrations, carbon chemistry, and isotopic signatures; Coordinates.csv contains information regarding sampling locations; and Analysis_Notes.csv contains information regarding instrumentation and detection limits.

54 ENVIRONMENTAL SCIENCES↗

Pickless event detection and location: The waveform correlation event detection system (WCEDS) revisited

The standard paradigm for seismic event monitoring breaks the event detection problem down into a series of processing stages that can be categorized at the highest level into station-level processing and network-level processing algorithms (e.g., Le Bras and Wuster (2002)). At the station-level, waveforms are typically processed to detect signals and identify phases, which may subsequently be updated based on network processing. At the network-level, phase picks are associated to form events, which are subsequently located. Furthermore, waveforms are typically directly exploited only at the station-level, while network-level operations rely on earth models to associate and locate the events that generated the phase picks.

58 GEOSCIENCES↗

Expansion analyses of strategic petroleum reserve in Bayou Choctaw : revised locations.

This report summarizes a series of three-dimensional simulations for the Bayou Choctaw Strategic Petroleum Reserve. The U.S. Department of Energy plans to leach two new caverns and convert one of the existing caverns within the Bayou Choctaw salt dome to expand its petroleum reserve storage capacity. An existing finite element mesh from previous analyses is modified by changing the locations of two caverns. The structural integrity of the three expansion caverns and the interaction between all the caverns in the dome are investigated. The impacts of the expansion on underground creep closure, surface subsidence, infrastructure, and well integrity are quantified. Two scenarios were used for the duration and timing of workover conditions where wellhead pressures are temporarily reduced to atmospheric pressure. The three expansion caverns are predicted to be structurally stable against tensile failure for both scenarios. Dilatant failure is not expected within the vicinity of the expansion caverns. Damage to surface structures is not predicted and there is not a marked increase in surface strains due to the presence of the three expansion caverns. The wells into the caverns should not undergo yield. The results show that from a structural viewpoint, the locations of the two newly proposed expansion caverns are acceptable, and all three expansion caverns can be safely constructed and operated.

02 PETROLEUM↗

Locating Microearthquakes In The Salton Sea Geothermal Field, California

We report the results of a 6-month microearthquake study of the Salton Sea Geothermal Field, California. This active geothermal field is also seismically active due to the flow of fluids through pre-existing fractures of rocks in the subsurface which can cause faults to slip. Locating these seismic events within the geothermal field enables researchers to determine whether the earthquakes are anthropogenic or tectonic from the nearby Brawley Seismic Zone. We analyzed November 2009 to April 2010 seismic waveform data retrieved from a network of continuously recording seismometers covering an area of 10 km 2 . 2,271 microearthquake hypocenters were processed out of 2,609 total recorded events and their locations suggest the majority could be at approximately the same depth as the fluid injection wells.

58 GEOSCIENCES↗

Addendum to the Survey Report for the Characterization of the Five Tanks Located Near the Old Salvage Yard at the Y-12 National Security Complex, Oak Ridge, Tennessee

The purpose if this addendum is to provide clarifying information related to two issues delaying disposal of Tank 2, located west of the Old Salvage Yard at the Y-12 National Security Complex. The two issues are as follows: 1. The discovery and documentation of apparent elevated results on the external rusty surface of Tank 2; 2. The proper interpretation and use of scan data. Oak Ridge Associated Universities (ORAU) health physics technicians (HPTs), operating under the Oak Ridge Institute for Science and Education contract, performed 100% scans over accessible interior and exterior surfaces of the five tanks located near the Old Salvage Yard, per the stakeholder-approved project-specific plan. Three types of measurements were collected, including gamma radiation measurements using a Ludlum model 44-10 gamma scintillation detector connected to a Ludlum model 2221 ratemeter/scaler; alpha radiation measurements using a Ludlum model 43-68 gas proportional detector connected to a 2221 ratemeter/scaler; and alpha-plus-beta radiation measurements also using a Ludlum model 43-68 connected to a 2221 ratermeter/scaler. The alpha-plus-beta characterization data is the primary subject of this addendum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of the Group 3-4 (HV-S1, HV-S2, IHLW-S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1-1999

This document reports on a series of tests conducted to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 3-4 exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The HV-S1, HV-S2, and IHLW-S1 exhaust stacks were tested together as a group (Test Group 3-4) because they share a geometric attribute: the common factor in their design is that the last significant flow disturbance upstream of the air sampling probe is a jog (i.e., two conjoined bends of equal and opposite curvature resulting in a change in elevation of the duct). Federal regulations require that a sampling probe be located in the exhaust stack according to criteria established by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

Glissmeyer, John A.↗

Assessment of Waste Treatment Plant Lab C3V (LB-S1) Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

This report documents a series of tests used to assess the proposed air sampling location in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Lab C3V (LB-S1) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that an air sampling probe be located in the exhaust stack in accordance with the criteria of American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

Air Sampling Probe↗

Acoustic emission non-destructive testing of structures using source location techniques.

The technology of acoustic emission (AE) testing has been advanced and used at Sandia for the past 40 years. AE has been used on structures including pressure vessels, fire bottles, wind turbines, gas wells, nuclear weapons, and solar collectors. This monograph begins with background topics in acoustics and instrumentation and then focuses on current acoustic emission technology. It covers the overall design and system setups for a test, with a wind turbine blade as the object. Test analysis is discussed with an emphasis on source location. Three test examples are presented, two on experimental wind turbine blades and one on aircraft fire extinguisher bottles. Finally, the code for a FORTRAN source location program is given as an example of a working analysis program. Throughout the document, the stress is on actual testing of real structures, not on laboratory experiments.

Beattie, Alan G.↗

Stratigraphic Profiles for Selected Hanford Site Seismometer Stations and Other Locations

Stratigraphic profiles were constructed for eight selected Hanford Site seismometer stations, five Hanford Site facility reference locations, and seven regional three-component broadband seismometer stations. These profiles provide interpretations of the subsurface layers to support estimation of ground motions from past earthquakes, and the prediction of ground motions from future earthquakes. In most cases these profiles terminated at the top of the Wanapum Basalt, but at selected sites profiles were extended down to the top of the crystalline basement. The composite one-dimensional stratigraphic profiles were based primarily on previous interpretations from nearby boreholes, and in many cases the nearest deep borehole is located kilometers away.

58 GEOSCIENCES↗