Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Linear and Order Statistics Combiners for Pattern Classification

Several researchers have experimentally shown that substantial improvements can be obtained in difficult pattern recognition problems by combining or integrating the outputs of multiple classifiers. This chapter provides an analytical framework to quantify the improvements in classification results due to combining. The results apply to both linear combiners and order statistics combiners. We first show that to a first order approximation, the error rate obtained over and above the Bayes error rate, is directly proportional to the variance of the actual decision boundaries around the Bayes optimum boundary. Combining classifiers in output space reduces this variance, and hence reduces the 'added' error. If N unbiased classifiers are combined by simple averaging. the added error rate can be reduced by a factor of N if the individual errors in approximating the decision boundaries are uncorrelated. Expressions are then derived for linear combiners which are biased or correlated, and the effect of output correlations on ensemble performance is quantified. For order statistics based non-linear combiners, we derive expressions that indicate how much the median, the maximum and in general the i-th order statistic can improve classifier performance. The analysis presented here facilitates the understanding of the relationships among error rates, classifier boundary distributions, and combining in output space. Experimental results on several public domain data sets are provided to illustrate the benefits of combining and to support the analytical results.

Tumer, Kagan↗

Accuracy of the spin sum rule in XMCD for the transition-metal L edges from manganese to copper

The effective spin sum rule is widely used in the quantitative analysis of x-ray magnetic circular dichroism spectra. Here, this important, though imperfect, sum rule is reviewed with a detailed analysis of the various sources for errors and deviations. The simulations confirm that the final state effects of the core level spin-orbit coupling and the core-valence exchange interactions (multiplet effects) are linearly related with the effective spin sum-rule error. Within the charge transfer multiplet approach, we have analyzed these effects, in combination with the interactions affecting the magnetic ground state, including the crystal field strength, the charge transfer effects, the exchange (magnetic) field, and the 3d spin-orbit coupling. We find that for the late transition-metal systems, the error in the effective spin moment is between 5% and 10%, implying that for covalent and/or metallic systems the effective spin sum rule is precise to within 5-10 %. The error for 3d{sup 5} systems is {approx}30% and for 3d{sup 4} systems, the error is very large, implying that, without further information, the derived effective spin sum-rule values for 3d{sup 4} systems have no meaning.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Round-off errors in cutting plane algorithms based on the revised simplex procedure

This report statistically analyzes computational round-off errors associated with the cutting plane approach to solving linear integer programming problems. Cutting plane methods require that the inverse of a sequence of matrices be computed. The problem basically reduces to one of minimizing round-off errors in the sequence of inverses. Two procedures for minimizing this problem are presented, and their influence on error accumulation is statistically analyzed. One procedure employs a very small tolerance factor to round computed values to zero. The other procedure is a numerical analysis technique for reinverting or improving the approximate inverse of a matrix. The results indicated that round-off accumulation can be effectively minimized by employing a tolerance factor which reflects the number of significant digits carried for each calculation and by applying the reinversion procedure once to each computed inverse. If 18 significant digits plus an exponent are carried for each variable during computations, then a tolerance value of 0.1 x 10 to the minus 12th power is reasonable.

Moore, J. E.↗

Summary and Annotated Bibliography of Measurement Error Corrections with Potential Application in Future Quesst Mission Community Noise Studies

This document is motivated by likely needs of the Quesst mission community response tests, which will culminate in data collection and estimation of dose-response regression relationships for consideration by domestic and international aviation regulators. Furthermore, basic research questions evaluating interactions between rates of community annoyance, dose levels, and indicators of the presence of rattle, vibration, and startle hinge on hypothesis testing in the context of regression models. For a variety of reasons, noise doses may be known only imprecisely and may not reflect the actual level experienced by responding subjects. These differences between true dose and estimated dose, be they systematic or random, constitute covariate measurement error. Available statistics literature speaks to the impacts of measurement error on regression models, both in terms of bias in estimated coefficients and predicted values, and in terms of the loss of statistical power for hypothesis testing. Given the particulars of a categorical annoyance response variable and a continuous noise dose predictor variable subject to measurement error during testing, the emphasis of this report is on findings and methods pertinent to generalized linear (and mixed) models likely to be employed during the Quesst mission community tests. We reach the following conclusions: 1. Of four reviewed methods, structural Bayesian measurement error models and simulation extrapolation (SIMEX) may be the most readily applicable to Quesst mission community noise study objectives. 2. If warranted, a linear measurement model can help model systematic sources of measurement error that the classical measurement error does not. 3. For its ready implementation and small additional input requirements, simulation extrapolation may be ideally suited for addressing secondary research questions involving interactions between annoyance, noise dose, and other factors through hypothesis testing. 4. For their flexibility and ability to propagate uncertainty, structural Bayesian hierarchical models have great appeal for mission purposes; some care may be needed in developing appropriate probability models describing actual noise exposure during testing. An annotated bibliography logs additional papers and resources that may be of value to analysts in other projects and disciplines.

Dose-Response Model↗

Nonlinear Detector Response of Aqua MODIS Land Imaging Bands

The detectors in Aqua MODIS reflective solar bands (RSB) are calibrated assuming a linear relationship between the observed top-of-atmosphere radiance and the instrument output response. Any non-linear behavior in the system response can contribute to errors in NASA’s Level 1B MODIS reflectance and radiance products, which are used in a wide variety of Earth science applications. While most RSB detectors continue to have very linear behavior even after more than 18 years of operation, we present evidence that the detectors in Aqua MODIS bands 1 (645 nm) and 2 (858 nm) have deviations from gain linearity that change over the mission by up to 3%. We show a clear divergence between gain measurements made with the on-board solar diffuser (SD) at two different radiance levels, achieved by collecting data both with and without an attenuation screen. Radiance trends from lunar calibrations and typical desert and ocean scenes are also compared. We present a simple method to characterize the response non-linearity using a quadratic function by combining the results of the two sets of SD calibrations. Applying this quadratic calibration algorithm to the desert and lunar data results in improved agreement in their long-term radiance trends. A clear understanding of the magnitude of the gain non-linearity could be useful to help improve the quality of numerous MODIS science products, including the land imaging applications that rely heavily on these bands.

MODIS↗

SU-E-T-90: Accuracy of Calibration of Lithium-6 and -7 Enriched LiF TLDs for Neutron Measurements in High Energy Radiotherapy

Purpose: To determine the potential error involved in the interpretation of neutron measurements from medical linear accelerators (linacs) using TLD-600H and TLD-700H if standard AmBe and {sup 252}Cf neutron sources are used for calibration without proper inclusion of neutron energy spectrum information. Methods: The Kerma due to neutrons can be calculated from the energy released by various nuclear interactions (elastic and inelastic scatter, (n,α), (n,p), (n,d), (n,t), (n,2n), etc.). The response of each TLD can be considered the sum of the neutron and gamma components; each proportional to the Kerma. Using the difference between the measured TLD responses and the ratio of the calculated Kerma for each material, the neutron component of the response can be calculated. The Monte Carlo code MCNP6 has been used to calculate the neutron energy spectra resulting from photonuclear interactions in a Varian 21EX linac. TLDs have been exposed to the mixed (γ-n) field produced by a linac and AmBe and {sup 252}Cf standard neutron sources. Results: For dosimetry of neutrons from AmBe or {sup 252}Cf sources, assuming TLD-700H insensitivity to neutrons will Result in 10% or 20% overestimation of neutron doses respectively.For dosimetry of neutrons produced in a Varian 21EX, applying a calibration factor derived from a standard AmBe or {sup 252}Cf source will Result in an overestimation of neutron fluence, by as much as a factor of 47.The assumption of TLD-700H insensitivity to neutrons produced by linacs leads to a negligible error due to the extremely high Kerma ratio (600H/700H) of 3000 for the assumed neutron spectrum. Conclusion: Lithium-enriched TLDs calibrated with AmBe and/or {sup 252}Cf neutron sources are not accurate for use under the neutron energy spectrum produced by a medical linear accelerator.

60 APPLIED LIFE SCIENCES↗

Error Analysis of the Shuttle Orbital Maneuvering System P-V-T Propellant Gaging Module. Mission Planning, Mission Analysis and Software Formulation

An investigation of the shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module has revealed that the gaging errors due to the combined effects of random instrumentation measurement errors, propellant loading uncertainties, and simplifying assumptions in the software are non-linear over the range of the usable propellant quantity gage (0-100%), with the largest error being at the zero point. When the OMS propellant tanks in the orbiter vehicle pods are filled to contain 100% of the maximum usable propellant, the gaging error at the zero point was determined to be 9.5% for the fuel and 9.5% for the oxidizer. When the OMS propellant tanks initially contain 50% of the maximum usable propellant, the largest gaging error is still 9.5% for the fuel and 9.5% for the oxidizer.

Duhon, D. D.↗

Multi-Window Controllers for Autonomous Space Systems

Multi-window controllers select between elementary linear controllers using nonlinear windows based on the amplitude and frequency content of the feedback error. The controllers are relatively simple to implement and perform much better than linear controllers. The commanders for such controllers only order the destination point and are freed from generating the command time-profiles. The robotic missions rely heavily on the tasks of acquisition and tracking. For autonomous and optimal control of the spacecraft, the control bandwidth must be larger while the feedback can (and, therefore, must) be reduced.. Combining linear compensators via multi-window nonlinear summer guarantees minimum phase character of the combined transfer function. It is shown that the solution may require using several parallel branches and windows. Several examples of multi-window nonlinear controller applications are presented.

Lurie, B, J.↗

MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling

Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269–1274, 2016; Arch Dis Child 81.2:172–173, 1999) atlas. The evaluation of BAA can be a tedious and time-consuming process for the radiologist. As such, several computer-assisted detection/diagnosis (CAD) methods have been proposed for automation of BAA. Classical CAD tools have traditionally relied on hard-coded algorithmic features for BAA which suffer from a variety of drawbacks. Recently, the advent and proliferation of convolutional neural networks (CNNs) has shown promise in a variety of medical imaging applications. There have been at least two published applications of using deep learning for evaluation of bone age (Med Image Anal 36:41–51, 2017; JDI 1–5, 2017). However, current implementations are limited by a combination of both architecture design and relatively small datasets. The purpose of this study is to demonstrate the benefits of a customized neural network algorithm carefully calibrated to the evaluation of bone age utilizing a relatively large institutional dataset. In doing so, this study will aim to show that advanced architectures can be successfully trained from scratch in the medical imaging domain and can generate results that outperform any existing proposed algorithm. The training data consisted of 10,289 images of different skeletal age examinations, 8909 from the hospital Picture Archiving and Communication System at our institution and 1383 from the public Digital Hand Atlas Database. The data was separated into four cohorts, one each for male and female children above the age of 8, and one each for male and female children below the age of 10. The testing set consisted of 20 radiographs of each 1-year-age cohort from 0 to 1 years to 14–15+ years, half male and half female. The testing set included left-hand radiographs done for bone age assessment, trauma evaluation without significant findings, and skeletal surveys. A 14 hidden layer-customized neural network was designed for this study. The network included several state of the art techniques including residual-style connections, inception layers, and spatial transformer layers. Data augmentation was applied to the network inputs to prevent overfitting. A linear regression output was utilized. Mean square error was used as the network loss function and mean absolute error (MAE) was utilized as the primary performance metric. MAE accuracies on the validation and test sets for young females were 0.654 and 0.561 respectively. For older females, validation and test accuracies were 0.662 and 0.497 respectively. For young males, validation and test accuracies were 0.649 and 0.585 respectively. Finally, for older males, validation and test set accuracies were 0.581 and 0.501 respectively. The female cohorts were trained for 900 epochs each and the male cohorts were trained for 600 epochs. An eightfold cross-validation set was employed for hyperparameter tuning. Test error was obtained after training on a full data set with the selected hyperparameters. Using our proposed customized neural network architecture on our large available data, we achieved an aggregate validation and test set mean absolute errors of 0.637 and 0.536 respectively. To date, this is the best published performance on utilizing deep learning for bone age assessment. Our results support our initial hypothesis that customized, purpose-built neural networks provide improved performance over networks derived from pre-trained imaging data sets. We build on that initial work by showing that the addition of state-of-the-art techniques such as residual connections and inception architecture further improves prediction accuracy. This is important because the current assumption for use of residual and/or inception architectures is that a large pre-trained network is required for successful implementation given the relatively small datasets in medical imaging. Instead we show that a small, customized architecture incorporating advanced CNN strategies can indeed be trained from scratch, yielding significant improvements in algorithm accuracy. It should be noted that for all four cohorts, testing error outperformed validation error. One reason for this is that our ground truth for our test set was obtained by averaging two pediatric radiologist reads compared to our training data for which only a single read was used. This suggests that despite relatively noisy training data, the algorithm could successfully model the variation between observers and generate estimates that are close to the expected ground truth.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectral reflectance reconstruction with the locally weighted linear model

Spectral reflectance reconstruction by the local linear model has many advantages such as simple model structure, fast calculation speed and less chance to be over-fitting. However, local linear model often suffers from the outliers and prone to be under-fitting. In this paper, we propose a locally weighted linear model for spectral reflectance reconstruction. It improves the contribution of the local neighbors with higher similarity to the test point, which can reduce the influence of noisy points and redundant points. Experimental results show that the locally weighted linear model can effectively reduce the reconstruction error.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constant-Momentum Acceleration Time-of-Flight Mass Spectrometry with Energy Focusing

Fundamental aspects of constant--momentum acceleration time-­of-­flight mass spectrometry (CMA-TOFMS) are explored as a means to improve mass resolution. By accelerating all ions to the same momentum, rather than to the same energy, the effects of the initial ion spatial and energy distributions upon the total ion flight time are decoupled. This decoupling permits the initial spatial distribution of ions in the acceleration region to be optimized independently and energy focus, including ion turn-around-time error, to be accomplished with a linear-field reflectron. Constant-momentum acceleration also linearly disperses ions across time according to mass-to-change (m/z) ratio, instead of the quadratic relationship between flight time and m/z found in conventional TOFMS. Here, CMA-TOFMS is shown to achieve simultaneous spatial and energy focusing over a selected portion of the mass spectrum. An orthogonal-acceleration time-of-flight outfitted with a reduced-pressure dc glow discharge (GD) ionization source is used to demonstrate CMA-TOFMS with atomic ions. The influence of experimental parameters such as the amplitude and width of the time-dependent CMA pulse on mass resolution is investigated, and a useful CMA-TOFMS focusing window of 2 to 18 Da is found for GD-CMA-TOFMS.

Dennis, Elise A.↗

Deployment of neural-network-based neutron microscopic cross sections in the Griffin reactor physics application

The capability to utilize neural networks to predict macroscopic and microscopic cross section parametric spaces has been developed for the Griffin reactor physics application. The LibTorch interface enables Griffin's MOOSE-based materials to interact with LibTorch-trained models, allowing for the evaluation of complex macroscopic or microscopic cross section spaces, which are then used to evaluate the neutronic properties of the Griffin finite element model. This study benchmarks traditional ISOXML-formatted tabulation libraries against neural network-based models for 279 nuclides on 20,160 grid points for zero-dimensional and two-dimensional reactor models. Benchmark metrics include the fundamental mode eigenvalue, fission and absorption rates, and various temperature coefficients of reactivity (isothermal, fuel, and moderator). From the perspective of storage space, the complete set of LibTorch models uses 11 MB on disk, compared to the 10 GB for the ISOXML multigroup library that covers the same grid space. For the two-dimensional performance case considered in Griffin, the Torch model uses 97% less RAM than the reference ISOXML dataset while runtime increases by a factor of 3 when using the LibTorch model compared to the ISOXML dataset with multi-linear interpolation. The LibTorch model consistently yields errors within 0.01% for most analyzed quantities except for the temperature coefficients of reactivity where the maximum discrepancies are up to 0.3 $\frac{pcm}{K}$. Due to the neural network attempting to best predict quantities with no regard for a positive or negative bias for any given quantity, predictions may experience random fluctuations, resulting in both positive and negative errors. Future work will entail both depletion and coupled transient analysis to determine the predictive capabilities of Griffin with neural network-based cross sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Revisiting a minimally destructive analytic approach for determining electrochemical kinetic parameters: Measuring aluminum corrosion across a wide pH range based on the Butler-Volmer equation

Here, this study revisits the three-point sampling of the simplified Butler-Volmer equation to address the limitations of strong potentiodynamic polarization, which can introduce irreversible damage and uncertainty in corrosion analysis. The method extracts electrochemical kinetic parameters while minimizing polarization effects, evaluates noise sensitivity relative to overpotential, and accounts for errors from signal noise, OCP drift, ohmic resistance, and mass-transfer constraints. Verified against the Tafel extrapolation method for aluminum corrosion across a wide pH range, this low-polarization approach enables accurate evaluations with specific error estimates, offering a robust alternative to linear polarization resistance methods that assume constant Tafel slopes.

36 MATERIALS SCIENCE↗

Physics-Informed CoKriging: A Gaussian-Process-Regression-Based Multifidelity Method for Data-Model Convergence

In this work, we propose a new Gaussian process regression (GPR)-based multifidelity method: physics-informed CoKriging (CoPhIK). In CoKriging-based multifidelity methods, the quantities of interest are modeled as linear combinations of multiple parameterized stationary Gaussian processes (GPs), and the hyperparameters of these GPs are estimated from data via optimization. In CoPhIK, we construct a GP representing low-fidelity data using physics-informed Kriging (PhIK), and model the discrepancy between low- and highfidelity data using a parameterized GP with hyperparameters identified via optimization. Our approach reduces the cost of optimization for inferring hyperparameters by incorporating partial physical knowledge. We prove that the physical constraints in the form of deterministic linear operators are satisfied up to an error bound. Furthermore, we combine CoPhIK with a greedy active learning algorithm for guiding the selection of additional observation locations. The eciency and accuracy of CoPhIK are demonstrated for reconstructing the partially observed modified Branin function, reconstructing the sparsely observed state of a steady state heat transport problem, and learning a conservative tracer distribution from sparse tracer concentration measurements.

Yang, Xiu↗

Baryon acoustic oscillations from the complete SDSS-III Lyα-quasar cross-correlation function at z = 2.4

We present a measurement of baryon acoustic oscillations (BAO) in the cross-correlation of quasars with the Lyα-forest flux-transmission at a mean redshift z = 2.40. The measurement uses the complete SDSS-III data sample: 168,889 forests and 234,367 quasars from the SDSS Data Release DR12. In addition to the statistical improvement on our previous study using DR11, we have implemented numerous improvements at the analysis level allowing a more accurate measurement of this cross-correlation. We also developed the first simulations of the cross-correlation allowing us to test different aspects of our data analysis and to search for potential systematic errors in the determination of the BAO peak position. We measure the two ratios D H (z = 2.40)=r d = 9.01 ± 0.36 and D M (z = 2.40)=r d = 35.7 ±1.7, where the errors include marginalization over the non-linear velocity of quasars and the metal - quasar cross-correlation contribution, among other effects. These results are within 1.8σ of the prediction of the flat-ΛCDM model describing the observed CMB anisotropies.We combine this study with the Lyα-forest auto-correlation function (Bautista et al. 2017), yielding D H (z = 2.40)=r d = 8.94 ± 0.22 and D M (z = 2.40)=r d = 36.6 ± 1.2, within 2.3σ of the same flat-ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Conceptual design of extended magnetic probe set to improve 3D field detection in NSTX-U

Adding toroidal arrays of magnetic probes at the top and bottom of NSTX-U would improve both the detection of the multimodal plasma response to applied magnetic perturbations and the identification of the poloidal structure of unstable plasma modes, as well as contribute to the validation of MHD models, improve the understanding of the plasma response to external fields, and improve the error field correction. In this paper, the linear MHD code MARS-F/K has been used to identify poloidal locations that would improve the capability to measure stationary or near-stationary 3D fields that may result from the plasma response to external sources of non-axisymmetric fields. The study highlighted 6 poloidal positions where new arrays of both poloidal and radial magnetic field sensors would improve the poloidal resolution. Here, the proposed set of new arrays combined with the present ones is shown to be capable of measuring the poloidal structure of perturbations with n ≤ 6 and of detecting the multimodal plasma response. Assessment of the trade-off in the poloidal length of the probes leads to an ideal length between 10 cm and 30 cm. A method to configure the probes of a toroidal array based on the singular value decomposition condition number is proposed, and an ideal solution and a low-cost one are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Learning electric vehicle driver range anxiety with an initial state of charge-oriented gradient boosting approach

This manuscript focuses on the modeling of electric vehicle (EV) driver’s range anxiety, a fear that a vehicle does not have sufficient range, or state of charge (SOC) of the battery pack, to reach its destination and would strand its occupants. Despite numerous research studies on the modeling of charging behaviors, modeling efforts to understand at what battery percentages do EV drivers charge their vehicles, and what are the associated contributing factors, are rather limited. To this end, an ensemble learning model based on gradient boosting is developed. The model sequentially fits new predictors to new residuals of the previous prediction and, then, minimizes the loss when adding the latest prediction. A total of 18 features are defined and extracted from the multisource data, which cover information on driver, vehicles, stations, traffic conditions, as well as spatial-temporal context information of the charging events. The analyzed dataset includes 4.5-year’s charging event log data from 3,096 users and 468 public charging stations in Kansas City Missouri, and the macroscopic travel demand model maintained by the metropolitan planning organization. Here, the result shows the proposed model achieved a satisfactory result with a R square value of 0.54 and root mean square error of 0.14, both better than multiple linear regression model and random forest model. To reduce range anxiety, it is suggested that the priorities of deploying new charging facilities should be given to the areas with higher daily traffic prediction, with more conservative EV users or that are further from residential areas.

33 ADVANCED PROPULSION SYSTEMS↗

Tradeoff between energy and error in the discrimination of quantum-optical devices

We address the problem of energy-error tradeoff in the discrimination between two linear passive quantum optical devices with a single use. We provide an analytical derivation of the optimal strategy for beamsplitters and an iterative algorithm converging to the optimum in the general case. We then compare the optimal strategy with a simpler strategy using coherent input states and homodyne detection. It turns out that the former requires much less energy in order to achieve the same performances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗