Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load forecasting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

NREL Evaluates Performance of Hydraulic Hybrid Refuse Vehicles

This highlight describes NREL's evaluation of the in-service performance of 10 next-generation hydraulic hybrid refuse vehicles (HHVs), 8 previous-generation (model year 2013) HHVs, and 8 comparable conventional diesel vehicles operated by Miami-Dade County's Public Works and Waste Management Department in southern Florida. Launched in March 2015, the on-road portion of this 12-month evaluation focuses on collecting and analyzing vehicle performance data - fuel economy, maintenance costs, and drive cycles - from the HHVs and the conventional diesel vehicles. The fuel economy of heavy-duty vehicles, such as refuse trucks, is largely dependent on the load carried and the drive cycles on which they operate. In the right applications, HHVs offer a potential fuel-cost advantage over their conventional counterparts. This advantage is contingent, however, on driving behavior and drive cycles with high kinetic intensity that take advantage of regenerative braking. NREL's evaluation will assess the performance of this technology in commercial operation and help Miami-Dade County determine the ideal routes for maximizing the fuel-saving potential of its HHVs. Based on the field data, NREL will develop a validated vehicle model using the Future Automotive Systems Technology Simulator, also known as FASTSim, to study the impacts of route selection and other vehicle parameters. NREL is also analyzing fueling and maintenance data to support total-cost-of-ownership estimations and forecasts. The study aims to improve understanding of the overall usage and effectiveness of HHVs in refuse operation compared to similar conventional vehicles and to provide unbiased technical information to interested stakeholders.

33 ADVANCED PROPULSION SYSTEMS↗

Why Do Electricity Policy and Competitive Markets Fail to Use Advanced PV Systems to Improve Distribution Power Quality?

The increasing pressure for network operators to meet distribution network power quality standards with increasing peak loads, renewable energy targets, and advances in automated distributed power electronics and communications is forcing policy-makers to understand new means to distribute costs and benefits within electricity markets. Discussions surrounding how distributed generation (DG) exhibits active voltage regulation and power factor/reactive power control and other power quality capabilities are complicated by uncertainties of baseline local distribution network power quality and to whom and how costs and benefits of improved electricity infrastructure will be allocated. DG providing ancillary services that dynamically respond to the network characteristics could lead to major network improvements. With proper market structures renewable energy systems could greatly improve power quality on distribution systems with nearly no additional cost to the grid operators. Renewable DG does have variability challenges, though this issue can be overcome with energy storage, forecasting, and advanced inverter functionality. This paper presents real data from a large-scale grid-connected PV array with large-scale storage and explores effective mitigation measures for PV system variability. We discuss useful inverter technical knowledge for policy-makers to mitigate ongoing inflation of electricity network tariff components by new DG interconnection requirements or electricity markets which value power quality and control.

14 SOLAR ENERGY↗

A BI-LEVEL APPROACH TO FUTURE POWER SYSTEM CO-OPTIMIZATION WITH HIGH PENETRATION OF RENEWABLE ENERGY AND RESPONSIVE DEMAND

Electricity generation accounts for nearly half of the total CO2 emissions in the United States. For this reason, the development and integration of renewable resources will play an essential role in achieving the societal objective of mitigating climate change through reduction of greenhouse gas emissions. In conjunction with the environmental benefits of renewable energy, the most common renewable sources, such as wind and solar, also increase the uncertainties surrounding generation in power systems, which adds significant challenges to the system operation and planning. The uncertainties and forecasting errors surrounding renewable generation are normally addressed through the use of reserves from traditional generators. At greater levels of renewable penetration, sufficient generator reserves may not be available or economically viable. In contrast, the promise of demand-side resources in this arena lies in the spatially widespread availability, rapid response potential, and lower cost of features that already exist in the system. However, the challenge of responsive demand arises from the need to understand, manage, and incentivize a very large number of resources to participate effectively in efficient operation of the complex power system. Since demand response comes from the distribution system, microgrids as the basic building blocks of future distribution systems will be a critical environment for the study of demand response. To support integration of microgrids with flexible loads in future power systems, the operational mode of power systems will need to evolve. Therefore, it is going to be critical to have new and efficient co-optimization methods for coordination of the various power market participants and the scheduling of resources in the power systems of the future. Motivated by the rapid increase in renewable penetration, the need for effective demand response programs, and a changing system structure, this dissertation seeks to define a new strategy that supports co-optimization of various participants in power systems with emphasis on high renewable penetration and demand response. This strategy has three components; 1) an exploration of the capabilities of different types of demand response programs in a microgrid, 2) development and implementation of a bi-level framework for co-optimization of the main grid with high renewable penetration and a microgrid with demand response capabilities, and 3) expansion of the bi-level framework from a microgrid to a general distribution system to explore the advantages of the bi-level co-optimization approach over the traditional optimization approach. Conclusions of this work illustrate that the stochastic rolling horizon approach could effectively manage the operation of a microgrid with various demand response programs. In addition, the bi-level approach is a promising co-optimization framework for the transmission and distribution levels that could increase system renewable penetration and reduce operation costs. Compared to the traditional framework, the bi-level framework yields more equitable cost sharing patterns among the market participants as well as better support for the power system evolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational Efficient Upscaling Methodology for Predicting Thermal Conductivity of Nuclear Waste forms

This study evaluated different upscaling methods to predict thermal conductivity in loaded nuclear waste form, a heterogeneous material system. The efficiency and accuracy of these methods were compared. Thermal conductivity in loaded nuclear waste form is an important property specific to scientific researchers, in waste form Integrated performance and safety code (IPSC). The effective thermal conductivity obtained from microstructure information and local thermal conductivity of different components is critical in predicting the life and performance of waste form during storage. How the heat generated during storage is directly related to thermal conductivity, which in turn determining the mechanical deformation behavior, corrosion resistance and aging performance. Several methods, including the Taylor model, Sachs model, self-consistent model, and statistical upscaling models were developed and implemented. Due to the absence of experimental data, prediction results from finite element method (FEM) were used as reference to determine the accuracy of different upscaling models. Micrographs from different loading of nuclear waste were used in the prediction of thermal conductivity. Prediction results demonstrated that in term of efficiency, boundary models (Taylor and Sachs model) are better than self consistent model, statistical upscaling method and FEM. Balancing the computation resource and accuracy, statistical upscaling is a computational efficient method in predicting effective thermal conductivity for nuclear waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Online Simulations of Global Aerosol Distributions in the NASA GEOS-4 Model and Comparisons to Satellite and Ground-Based Aerosol Optical Depth

We have implemented a module for tropospheric aerosols (GO CART) online in the NASA Goddard Earth Observing System version 4 model and simulated global aerosol distributions for the period 2000-2006. The new online system offers several advantages over the previous offline version, providing a platform for aerosol data assimilation, aerosol-chemistry-climate interaction studies, and short-range chemical weather forecasting and climate prediction. We introduce as well a methodology for sampling model output consistently with satellite aerosol optical thickness (AOT) retrievals to facilitate model-satellite comparison. Our results are similar to the offline GOCART model and to the models participating in the AeroCom intercomparison. The simulated AOT has similar seasonal and regional variability and magnitude to Aerosol Robotic Network (AERONET), Moderate Resolution Imaging Spectroradiometer, and Multiangle Imaging Spectroradiometer observations. The model AOT and Angstrom parameter are consistently low relative to AERONET in biomass-burning-dominated regions, where emissions appear to be underestimated, consistent with the results of the offline GOCART model. In contrast, the model AOT is biased high in sulfate-dominated regions of North America and Europe. Our model-satellite comparison methodology shows that diurnal variability in aerosol loading is unimportant compared to sampling the model where the satellite has cloud-free observations, particularly in sulfate-dominated regions. Simulated sea salt burden and optical thickness are high by a factor of 2-3 relative to other models, and agreement between model and satellite over-ocean AOT is improved by reducing the model sea salt burden by a factor of 2. The best agreement in both AOT magnitude and variability occurs immediately downwind of the Saharan dust plume.

Colarco, Peter↗

Projecting Future Energy Production from Operating Wind Farms in North America. Part III: Variability

Abstract Daily expected wind power production from operating wind farms across North America are used to evaluate capacity factors (CF) computed using simulation output from the Weather Research and Forecasting (WRF) Model and to condition statistical models linking atmospheric conditions to electricity production. In Parts I and II of this work, we focus on making projections of annual energy production and the occurrence of electrical production drought. Here, we extend evaluation of the CF projections for sites in the Northeast, Midwest, southern Great Plains (SGP), and southwest U.S. coast (SWC) using statewide wind-generated electricity supply to the grid. We then quantify changes in the time scales of CF variability and the seasonality. Currently, wind-generated electricity is lowest in summer in each region except SWC, which causes a substantial mismatch with electricity demand. While electricity of residential heating may shift demand, research presented here suggests that summertime CF are likely to decline, potentially exacerbating the offset between seasonal peak power production and current load. The reduction in summertime CF is manifest for all regions except the SGP and appears to be linked to a reduction in synoptic-scale variability. Using fulfillment of 50% and 90% of annual energy production to quantify interannual variability, it is shown that wind power production exhibits higher (earlier fulfillment) or lower (later fulfillment) production for periods of over 10–30 years as a result of the action of internal climate modes. Significance Statement Electrical power system reassessment and redesign may be needed to aid efficient increased use of variable renewables in the generation of electricity. Currently wind-generated electricity in many regions of North America exhibits a minimum in summertime and hence is not well synchronized with electricity demand, which tends to be maximized in summer. Future projections indicate evidence of reductions in wind power during summer that would amplify this offset. However, electrification of heating may lead to increased wintertime demand, which would lead to greater synchronization.

Coburn, Jacob↗

AERoBOND Project Summary

Under NASA’s Convergent Aeronautics Solutions (CAS) project, the Adhesive-Free Bonding of Complex Composites (AERoBOND) project investigated off-stoichiometric epoxy polymers for fast, reliable assembly of epoxy matrix composite structures. The project goal was to demonstrate feasibility of the AERoBOND joining method by demonstrating mechanical properties greater than 80% of conventional co-cured materials while reducing structure weight by 1%. The project consisted of three convergent research areas: material and process development, systems analysis, and material and process modeling. Material and process development was the largest component of AERoBOND with approximately 6 FTE and 1WYE of support to formulate and characterize new resins, prepare carbon fiber prepregs, fabricate laminates, measure mechanical properties, analyze failure results, and select material and process improvements. The systems analysis activity estimated the potential reduction in part count and aircraft weight by comparing models of composite wing boxes with no fasteners (co-cured structure), fasteners in major joints (co-cured stringers), and fasteners in all joints. The materials and process modeling activity included a molecular model of the AERoBOND materials system to predict mechanical properties of resins with offset stoichiometry and a process model to predict the effect of resin formulation and processing conditions on the extent of mixing and degree of cure in a finished joint. As the number of airline passenger trips doubles in the next 20 years (IATA/Tourism Economics Air Passenger Forecasts, April 2019), the increased demand for new commercial aircraft is now the single greatest technical challenge to the airframe manufacturing industry. To meet efficiency requirements, new aircraft must be fabricated primarily from high performance structural composites, but manufacturing processes are inherently slow with the largest bottleneck attributed to assembly and installation of fasteners (NASA/TM–2019-220428). Manufactures of commercial transport aircraft are compelled to install more than 100,000 redundant fasteners into bonded joints to prevent failures due to unpredictable weak bonds. In structural adhesive bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination, which can cause weak bonds. Currently, bond strength assessment is only possible through destructive testing (i.e., breaking the joint). For these reasons, regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to alleviate concerns with bond performance. The AERoBOND process enables reflow of matrix resin during assembly to eliminate the material discontinuity at the interface, thereby eliminating the dependence of mechanical performance on interfacial adhesion. The AERoBOND joint is equivalent to the interlaminar region obtained during a co-cure process, so joint performance depends on the cohesive properties of the matrix resin. Conventional co-cured structures, although too costly and complex for large-scale manufacturing, are trusted by manufacturers and regulators, and are certified for flight with few or no redundant fasteners.Systems analysis performed on a composite wing model at the scale of a single-aisle commercial transport aircraft indicated that >20,000 redundant fasteners per wing could be eliminated by implementing the AERoBOND joining method. A total weight reduction of 15% was predicted in a wing box by eliminating fasteners and thinning components that must no longer support localized fastener loads and accommodate fastener dimensions. Interlaminar shear fracture toughness measured by the end-notched flexure test was greater than 1 kJ/m2 (nearly 140% of the co-cured benchmark property), which is greatly in excess of the project goals for mechanical properties. Testing was planned to measure interlaminar tensile fracture toughness as well as interlaminar tensile and shear strengths using the same AERoBOND configuration, but was delayed due to closure of LaRC facilities during the COVID-19 pandemic. The AERoBOND process model is partially validated and available for experimental use. It allows the user to input AERoBOND process parameters such as material composition, laminate configuration, and cure cycle to predict the final cure state of the AERoBOND joint. A preliminary, multi-scale material model was developed to predict AERoBOND joint mechanical properties (stiffness and strength) based on the cure state of the joint provided by the process model. The timing for transition of this technology within NASA is excellent as NASA initiates new enduring projects to address composites manufacturing rate challenges. AERoBOND technology is well suited to AAVP/AATT objectives for rapid manufacturing of a composite wing. A minimal effort (1 FTE/$15k procurement/0 WYE) is proposed in FY21 to continue a minor mechanical testing effort and maintain a SAA with ASX composites to develop commercial quality prepreg material. An RFI with the composites industry is suggested to quantify the technology gap between the current TRL and the TRL needed for transition to industry. A moderate effort [3-4 FTE/$150k/1 WYE (~$115k)] is proposed in FY22 for the “high rate composites manufacturing” project currently in planning. The partnership with ASX Composites will be expanded to produce material for sub-element/element-scale “panel-off” activities. Industry partnerships with airframe manufacturers is an expected component to explore damage tolerance and environmental stability. Further development of multi-scale modeling tools (process model, meso-scale model, and molecular model) is planned to enhance and deliver tools for rapid manufacturing infusion.

Frank Louis Palmieri↗

Wake steering optimization under uncertainty

Turbines in wind power plants experience significant power losses when wakes from upstream turbines affect the energy production of downstream turbines. A promising plant-level control strategy to reduce these losses is wake steering, where upstream turbines are yawed to direct wakes away from downstream turbines. However, there are significant uncertainties in many aspects of the wake steering problem. For example, infield sensors do not give perfect information, and inflow to the plant is complex and difficult to forecast with available information, even over short time periods. Here, we formulate and solve an optimization under uncertainty (OUU) problem for determining optimal plant-level wake steering strategies in the presence of independent uncertainties in the direction, speed, turbulence intensity, and shear of the incoming wind, as well as in turbine yaw positions. The OUU wake steering strategy is first examined for a two-turbine test case to explore the impacts of different types of inflow uncertainties, and it is then demonstrated for a more realistic 11-turbine wind power plant. Of the sources of uncertainty considered, we find that wake steering strategies are most sensitive to uncertainties in the wind speed and direction. When maximizing expected power production, the OUU strategy also tends to favor smaller yaw angles, which have been shown in previous work to reduce turbine loading. Ultimately, the plant-level wake steering strategy formulated using an OUU approach yields 0.48?% more expected annual energy production for the 11-turbine wind plant than a strategy that neglects uncertainty when considering stochastic inputs. Thus, not only does the present OUU strategy produce more power in realistic conditions, but it also reduces risk by prescribing strategies that call for less extreme yaw angles.

17 WIND ENERGY↗

Implementation of Remaining Useful Lifetime Transformer Models in the Fleet-Wide Prognostic and Health Management Suite

Research and development efforts are required to address aging and reliability concerns of the existing fleet of nuclear power plants. As most plants continue to operate beyond the license life (i.e., towards 60 or 80 years), plant components are more likely to incur age-related degradation mechanisms. To assess and manage the health of aging plant assets across the nuclear industry, the Electric Power Research Institute has developed a web-based Fleet-Wide Prognostic and Health Management (FW-PHM) Suite for diagnosis and prognosis. FW-PHM is a set of web-based diagnostic and prognostic tools and databases, comprised of the Diagnostic Advisor, the Asset Fault Signature Database, the Remaining Useful Life Advisor, and the Remaining Useful Life Database, that serves as an integrated health monitoring architecture. The main focus of this paper is the implementation of prognostic models for generator step-up transformers in the FW-PHM Suite. One prognostic model discussed is based on the functional relationship between degree of polymerization, (the most commonly used metrics to assess the health of the winding insulation in a transformer) and furfural concentration in the insulating oil. The other model is based on thermal-induced degradation of the transformer insulation. By utilizing transformer loading information, established thermal models are used to estimate the hot spot temperature inside the transformer winding. Both models are implemented in the Remaining Useful Life Database of the FW-PHM Suite. The Remaining Useful Life Advisor utilizes the implemented prognostic models to estimate the remaining useful life of the paper winding insulation in the transformer based on actual oil testing and operational data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tracking the weight of Hurricane Harvey’s stormwater using GPS data

On 26 August 2017, Hurricane Harvey struck the Gulf Coast as a category four cyclone depositing ~95 km 3 of water, making it the wettest cyclone in U.S. history. Water left in Harvey’s wake should cause elastic loading and subsidence of Earth’s crust, and uplift as it drains into the ocean and evaporates. To track daily changes of transient water storage, we use Global Positioning System (GPS) measurements, finding a clear migration of subsidence (up to 21 mm) and horizontal motion (up to 4 mm) across the Gulf Coast, followed by gradual uplift over a 5-week period. Inversion of these data shows that a third of Harvey’s total stormwater was captured on land (25.7 ± 3.0 km 3 ), indicating that the rest drained rapidly into the ocean at a rate of 8.2 km 3 /day, with the remaining stored water gradually lost over the following 5 weeks at ~1 km 3 /day, primarily by evapotranspiration. These results indicate that GPS networks can remotely track the spatial extent and daily evolution of terrestrial water storage following transient, extreme precipitation events, with implications for improving operational flood forecasts and understanding the response of drainage systems to large influxes of water.

54 ENVIRONMENTAL SCIENCES↗

Calibration of cloud and aerosol related parameters for solar irradiance forecasts in WRF-solar

Model parameters are a major source of uncertainty in numerical weather prediction. Recently, the Weather Research and Forecasting model with Solar extensions (WRF-Solar) has been upgraded by enhancing the treatment of sub-grid scale cloud and aerosols with augmentations of a sub-grid scale cloud scheme (CLD3) and an upgraded aerosol-aware Thompson-Eidhammer scheme (TE14). However, the value of model parameters associated with these parameterizations are assigned based on limited measurements or theoretical calculations. Calibrating the most sensitive parameters has the potential to improve solar irradiance predictions. Here, we adopted a multiobjective surrogate-based optimization (SBO) framework to calibrate nine parameters used in CLD3 and TE14 that lead to the largest sensitivity in simulated irradiance. The normalized mean-absolute-error (NMAE) of global horizontal irradiance (GHI) and direct normal irradiance (DNI) are minimized by calibrating WRF-Solar over two regions including the Southern Great Plains (SGP) and Central California, in order to focus on parameter calibration under cloudy conditions with different aerosol loading. The results show that generalized linear model (GLM)-based surrogate models approximate physical models well, particularly when the third order and three-way interaction terms are considered. The SBO framework efficiently searches the parameter space for optimal solutions with less computational costs than directly calibrating the physical model. We first calibrate CLD3 parameters over the less-polluted SGP region. Optimized CLD3 parameters alone result in NMAE reduction by 14% for the site-mean and up to 33% for individual cases over the SGP region. With further calibration of TE14 parameters over the Central California during active fire periods, the optimized parameters lead to over 20% reductions of NMAE. Our investigation reveals, however, that optimizing TE14 has a limited impact on irradiance simulations under less-polluted conditions in the SGP.

14 SOLAR ENERGY↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Temperature Humidity and Sea Level Pressure Increments Induced by 1DVAR Analysis of GPS Refractivity

The Global Positioning System (GPS) transmitted signals are affected by the atmosphere. Using the radio occultation technique, where a receiver is placed on a low-Earth-orbiting platform. it is possible to perform soundings. by measuring the bending angles of the rays. The information can be converted into atmospheric refractivity. We have developed a one dimensional variational (1DVAR) analysis that uses GPS/MET 1995 refractivity and 6-hour FVDAS (Finite Volume Data Assimilation System) forecasts as background information to constrain the retrievals. The analysis increments are defined as 1DVAR minus background temperature, humidity and sea level pressure. Before assimilating the 1DVAR profiles into the FVDAS. the increments need to be understood. First, some bias could be induced in the retrievals when confronted with actual biased data: second. bias in the back-round could create undesired bias in the retrievals. Anv bias in the analyses will ultimately change the climatology of the model the retrievals will be assimilated into. We relate the increments to the reduction of the difference between observed minus computed refractivity profiles. We also point out the difference in the mean increments using backgrounds which have assimilated either NESDIS TIROS Operational Vertical Sounder (TOVS) operational retrievals or Data Assimilation Office (DAO) TOVS interactive retrievals. The climatology of the model in terms of refractivity is significantly different and this impacts the GPS 1DVAR increments. This testifies that changing the basic load of assimilated data has an influence on the impact the GPS data may have in a DAS.

Poli, Paul↗

Effectiveness of street trees in reducing air temperature and outdoor heat exposure in Las Vegas

Urban greening and especially tree planting strategies are being widely planned and implemented to mitigate urban overheating and thermal stress in many urban areas. However, the effectiveness of these strategies depends on multiple factors, including urban morphology, environmental conditions, and tree characteristics. This study investigates the effects of street tree planting strategies on air temperature and outdoor heat exposure in Las Vegas by combining an urbanized mesoscale climate model coupled to a multi-layer street tree model (Weather Research and Forecasting-BEP-Tree; Δ x = 900 m) with a microscale pedestrian heat exposure model (Temperatures of Urban Facets for Pedestrian; Δ x = 1 m). A series of simulations are conducted for July and August 2022. Large city-wide increases of a drought tolerant tree species cool air temperature mainly during the nighttime (up to 1.5 °C), with daytime effects being limited due to leaves shedding sensible instead of latent heat as stomata close in response to high vapor pressure deficits. Increased evaporative cooling is achieved with a different tree species (double at night, and reaching 0.4 °C during the day), but water requirements increase threefold. Despite their relatively small effect on air temperature during the day, trees provide significant shade by intercepting solar radiation, reducing mean radiant temperature (up to 16 °C) and enhancing outdoor thermal comfort, a major benefit of street trees in hot arid climates. The nighttime cooling of trees and the daytime reduction of radiant loading show potential to reduce the heat-related health impacts. Our results highlight the need to evaluate the effects of street trees on a case-by-case basis.

54 ENVIRONMENTAL SCIENCES↗

Auroral ovals versus flare ribbons: Optical footprints of explosive magnetic field reconfiguration in Earth’s magnetosphere and the Sun’s corona

Despite drastically different plasma conditions in the two systems, eruptive energy release events in solar active regions and in Earth’s magnetosphere have a lot in common. Both solar active region eruptions and the substorm activity in the nightside magnetosphere are known to be associated with an abrupt large-scale reorganization of the supporting magnetic systems enabling the conversion and dissipation of the stored free magnetic energy. The rate of energy accumulation in either system tends to be by orders of magnitude slower than the energy release rate, leading to the formation of an impulsive loading-unloading cycle involving a relatively long pre-reconnection phase (substorm growth phase, pre-flare stressing of an active region magnetic field), a short and explosive reconnection phase (substorm breakup and expansion, eruptive flares and CMEs), and a prolonged post-reconnection phase (substorm recovery phase and the post-flare active region reconfiguration). In Earth’s magnetosphere, this loading-unloading cycle is diagnosed by monitoring characteristic changes in the particle precipitation pattern in the northern and southern auroral ovals marking the boundary between the open and close magnetic flux. The position, shape, structure, and dynamics of the auroral borealis were shown to communicate critically important information about an upcoming substorm, the location and timing of the initial reconnection onset, and the subsequent return of the magnetosphere to a lower-energy state. On the Sun, a similar role is played by the chromospheric flare ribbons which enable a detailed diagnostics of the overlying reconnecting magnetic field. In this talk, we’ll discuss similarities and differences in using auroral and flare ribbon observations for monitoring eruptive energy release in respectively Earth’s magnetosphere and solar corona. Special emphasis will be placed on the quantitative interpretation of the two types of optical signatures for empirical diagnostics of the underlying reconnection activity and for constraining its theoretical models. We’ll also compare forecasting capabilities of the two types of optical signatures in the context of space weather prediction objectives.

V. M. Uritskiy↗

Mapping of crack tip strains and twinned zone in a hexagonal close packed zirconium alloy.

This paper describes the use of synchrotron X-ray diffraction to map crack tip strain field evolution and initiation of twinning under applied load in a fatigue pre-cracked zirconium alloy. Compact tension specimens were machined in two orientations from a textured rolled plate and loaded along the normal direction and the transverse direction to rolling. Residual strains due to fatigue and the strains introduced at applied K, of approximately 10 and 30 MPa{radical}m were measured for the two specimen orientations. Maps of the region of twinned material were determined. The experimental data is compared to finite element (FE) calculations for the crack tip strain fields and a prediction of the size of the twinned region using a multiscale model based on combining an FE approach with an elastoplastic self-consistent polycrystalline plasticity model.

36 MATERIALS SCIENCE↗

New power politics will determine generation's path

The US power industry's story in 2009 will be all about change, to borrow a now-familiar theme. Though the new administration's policy specifics had not been revealed as this report was prepared, it appears that flat load growth in 2009 will give the new Obama administration a unique opportunity to formulate new energy policy without risking that the lights will go out. New coal projects are now facing increasing difficulties. It looks as though the electricity supply industry will continue to muddle through. It may see an advancement in infrastructure investment, significant new generation or new technology development. It also faces the possibility that policies necessary to achieving those goals will not materialize, for political and economic reasons. 4 figs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗