Search NASA⌕ Search

SEARCH · Search NASA

Results for “Match Machining”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

H-mode pedestal scaling in DIII-D, ASDEX Upgrade, and JET

Multidevice pedestal scaling experiments in the DIII-D, ASDEX Upgrade (AUG), and JET tokamaks are presented in order to test two plasma physics pedestal width models. The first model proposes a scaling of the pedestal width {Delta}/a {proportional_to} {rho}*{sup 1/2} to {rho}* based on the radial extent of the pedestal being set by the point where the linear turbulence growth rate exceeds the ExB velocity. In the multidevice experiment where {rho}* at the pedestal top was varied by a factor of four while other dimensionless parameters where kept fixed, it has been observed that the temperature pedestal width in real space coordinates scales with machine size, and that therefore the gyroradius scaling suggested by the model is not supported by the experiments. The density pedestal width is not invariant with {rho}* which after comparison with a simple neutral fuelling model may be attributed to variations in the neutral fuelling patterns. The second model, EPED1, is based on kinetic ballooning modes setting the limit of the radial extent of the pedestal region and leads to {Delta}{sub {psi} {proportional_to}} {beta}{sub p}{sup 1/2}. All three devices show a scaling of the pedestal width in normalised poloidal flux as {Delta}{sub {psi} {proportional_to}} {beta}{sub p}{sup 1/2}, as described by the kinetic ballooning model; however, on JET and AUG, this could not be distinguished from an interpretation where the pedestal is fixed in real space. Pedestal data from all three devices have been compared with the predictive pedestal model EPED1 and the model produces pedestal height values that match the experimental data well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ambient-temperature liquid jet targets for high-repetition-rate HED discovery science

High-power lasers can generate energetic particle beams and astrophysically relevant pressure and temperature states in the high-energy-density (HED) regime. Recently-commissioned high-repetition-rate (HRR) laser drivers are capable of producing these conditions at rates exceeding 1 Hz. However, experimental output from these systems is often limited by the difficulty of designing targets that match these repetition rates. To overcome this challenge, we have developed tungsten microfluidic nozzles, which produce a continuously replenishing jet that operates at flow speeds of approximately 10 m/s and can sustain shot frequencies up to 1 kHz. The ambient-temperature planar liquid jets produced by these nozzles can have thicknesses ranging from hundreds of nanometers to tens of micrometers. In this work, we illustrate the operational principle of the microfluidic nozzle and describe its implementation in a vacuum environment. Further, we provide evidence of successful laser-driven ion acceleration using this target and discuss the prospect of optimizing the ion acceleration performance through an in situ jet thickness scan. Future applications for the jet throughout HED science include shock compression and studies of strongly heated nonequilibrium plasmas. When fielded in concert with HRR-compatible laser, diagnostic, and active feedback technology, this target will facilitate advanced automated studies in HRR HED science, including machine learning-based optimization and high-dimensional statistical analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine Learning‐Assisted Microearthquake Location Workflow for Monitoring the Newberry Enhanced Geothermal System

Abstract Enhanced geothermal systems (EGS) offer a sustainable energy source but face challenges in accurately locating microearthquakes induced during reservoir stimulation. Locating these microearthquakes provides reliable feedback on the stimulation progress. Current deep learning methods for locating earthquakes require extensive data sets for training, which is problematic as detected microearthquakes are often limited. To address the scarcity of training data, we propose a practical workflow using probabilistic multilayer perceptron (PMLP) which predicts microearthquake locations from cross‐correlation time lags in waveforms. Utilizing a 3D velocity model of Newberry site derived from ambient noise interferometry, we generate numerous synthetic microearthquakes and 3D acoustic waveforms for PMLP training. Accurate synthetic tests prompt us to apply the trained network to the 2012 and 2014 stimulation field waveforms. To enhance the accuracy of source localization, we carefully handpick the P‐arrival times. Predictions on the 2012 stimulation data set show major microseismic activity at depths of 0.5–1.2 km, correlating with a known casing leakage scenario. In the 2014 data set, the majority of predictions concentrate at 2.0–2.9 km depths, consistent with results obtained from conventional physics‐based inversion, and align with the presence of natural fractures from 2.0 to 2.7 km. We validate our findings by comparing the synthetic and field picks, demonstrating a satisfactory match for the first arrivals. By combining the benefits of quick inference speeds and accurate location predictions, we demonstrate the feasibility of using realistic synthetic data set to locate microseismicity for EGS monitoring.

15 GEOTHERMAL ENERGY↗

Informing NLP Learning Tasks by Tracking User Features: An ASRS Use Case using Kaona

There has been growing interest in utilizing natural language processing (NLP) algorithms in Aviation Safety. This interest has extended to leveraging the decades of records publicly available on the Aviation Safety Reporting System (ASRS). While related literature has given more emphasis in lessons learned from the narratives, our prior work has focused on using NLP to support narrative search in the ASRS. Specifically, we evaluated if the use of alternative search mechanisms to keyword search, such as the retrieval of related narratives even without matching keywords could improve narrative discovery. A difficulty in experimenting alternative search mechanisms in any information retrieval task is the lack of ground truth. To address this limitation, we propose Kaona, a lightweight interface which enables the prototyping of alternative search retrieval tasks, by tracking user experience both explicitly (user-specified feedback), or implicitly (user navigation through interface affordances). Differently from distracting requests for feedback during user navigation, Kaona collects explicit feedback from users by mapping them to affordances which support the user workflow, while obtaining ground truth information for learning tasks.

human-computer-interaction↗

Equalization and detection for digital communication over nonlinear bandlimited satellite communication channels

This dissertation evaluates receiver-based methods for mitigating the effects due to nonlinear bandlimited signal distortion present in high data rate satellite channels. The effects of the nonlinear bandlimited distortion is illustrated for digitally modulated signals. A lucid development of the low-pass Volterra discrete time model for a nonlinear communication channel is presented. In addition, finite-state machine models are explicitly developed for a nonlinear bandlimited satellite channel. A nonlinear fixed equalizer based on Volterra series has previously been studied for compensation of noiseless signal distortion due to a nonlinear satellite channel. This dissertation studies adaptive Volterra equalizers on a downlink-limited nonlinear bandlimited satellite channel. We employ as figure of merits performance in the mean-square error and probability of error senses. In addition, a receiver consisting of a fractionally-spaced equalizer (FSE) followed by a Volterra equalizer (FSE-Volterra) is found to give improvement beyond that gained by the Volterra equalizer. Significant probability of error performance improvement is found for multilevel modulation schemes. Also, it is found that probability of error improvement is more significant for modulation schemes, constant amplitude and multilevel, which require higher signal to noise ratios (i.e., higher modulation orders) for reliable operation. The maximum likelihood sequence detection (MLSD) receiver for a nonlinear satellite channel, a bank of matched filters followed by a Viterbi detector, serves as a probability of error lower bound for the Volterra and FSE-Volterra equalizers. However, this receiver has not been evaluated for a specific satellite channel. In this work, an MLSD receiver is evaluated for a specific downlink-limited satellite channel. Because of the bank of matched filters, the MLSD receiver may be high in complexity. Consequently, the probability of error performance of a more practical suboptimal MLSD receiver, requiring only a single receive filter, is evaluated.

Gutierrez, Alberto, Jr.↗

Provenance in Data Interoperability for Multi-Sensor Intercomparison

As our inventory of Earth science data sets grows, the ability to compare, merge and fuse multiple datasets grows in importance. This requires a deeper data interoperability than we have now. Efforts such as Open Geospatial Consortium and OPeNDAP (Open-source Project for a Network Data Access Protocol) have broken down format barriers to interoperability; the next challenge is the semantic aspects of the data. Consider the issues when satellite data are merged, cross-calibrated, validated, inter-compared and fused. We must match up data sets that are related, yet different in significant ways: the phenomenon being measured, measurement technique, location in space-time or quality of the measurements. If subtle distinctions between similar measurements are not clear to the user, results can be meaningless or lead to an incorrect interpretation of the data. Most of these distinctions trace to how the data came to be: sensors, processing and quality assessment. For example, monthly averages of satellite-based aerosol measurements often show significant discrepancies, which might be due to differences in spatio- temporal aggregation, sampling issues, sensor biases, algorithm differences or calibration issues. Provenance information must be captured in a semantic framework that allows data inter-use tools to incorporate it and aid in the intervention of comparison or merged products. Semantic web technology allows us to encode our knowledge of measurement characteristics, phenomena measured, space-time representation, and data quality attributes in a well-structured, machine-readable ontology and rulesets. An analysis tool can use this knowledge to show users the provenance-related distrintions between two variables, advising on options for further data processing and analysis. An additional problem for workflows distributed across heterogeneous systems is retrieval and transport of provenance. Provenance may be either embedded within the data payload, or transmitted from server to client in an out-of-band mechanism. The out of band mechanism is more flexible in the richness of provenance information that can be accomodated, but it relies on a persistent framework and can be difficult for legacy clients to use. We are prototyping the embedded model, incorporating provenance within metadata objects in the data payload. Thus, it always remains with the data. The downside is a limit to the size of provenance metadata that we can include, an issue that will eventually need resolution to encompass the richness of provenance information required for daata intercomparison and merging.

Lynnes, Chris↗

Casimir forces in the time domain: Applications

Our previous article [Phys. Rev. A 80, 012115 (2009)] introduced a method to compute Casimir forces in arbitrary geometries and for arbitrary materials that was based on a finite-difference time-domain (FDTD) scheme. In this article, we focus on the efficient implementation of our method for geometries of practical interest and extend our previous proof-of-concept algorithm in one dimension to problems in two and three dimensions, introducing a number of new optimizations. We consider Casimir pistonlike problems with nonmonotonic and monotonic force dependence on sidewall separation, both for previously solved geometries to validate our method and also for new geometries involving magnetic sidewalls and/or cylindrical pistons. We include realistic dielectric materials to calculate the force between suspended silicon waveguides or on a suspended membrane with periodic grooves, also demonstrating the application of perfectly matched layer (PML) absorbing boundaries and/or periodic boundaries. In addition, we apply this method to a realizable three-dimensional system in which a silica sphere is stably suspended in a fluid above an indented metallic substrate. More generally, the method allows off-the-shelf FDTD software, already supporting a wide variety of materials (including dielectric, magnetic, and even anisotropic materials) and boundary conditions, to be exploited for the Casimir problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-546: Modeling and Validation of the a New Proton Therapy System Using a Monte-Carlo Environment Optimized for Protons

8 particle histories were run. Results: Range measurements of the Monte-Carlo simulations matched the measured data within 1mm. Distal fall-off of the simulated fields matched within <1mm. Lateral penumbra and field size measurements of the standard-sized square and half-beam blocked fields matched within 1mm at all three planes compared. A small difference was seen in the in-air profiles at doses <0%. The suspected cause of the difference was the aperture shape. The measured data utilized a divergent aperture. The Monte-Carlo calculation used a non-divergent aperture. Conclusion: The validation measurements indicate that we were able to accurately model the MEVION s250 Proton therapy system using Monte-Carlo Calculations. This may reduce the commissioning time for future users. Purpose: Monte-Carlo modeling is an important tool for understanding the behavior of therapeutic proton beams in a heterogeneous media such as the patient. To gain confidence that a Monte-Carlo model is accurate in complex geometries and media, it must first be compared with measurement in simple situations. This study documents the validation of our Monte-Carlo Model. Methods: A model of the MEVION s250 Proton therapy system was created in the TOPAS Monte-Carlo environment using machine geometry and field shaping system information provided by the vendor. For each of 24 options, validation of the TOPAS model was performed by comparing the dose scored by TOPAS to the dose measurements obtained during the commissioning of the treatment planning system. The measurements compared consisted of: pristine peak depth-dose profiles, in-air profiles for a standard-sized square field (20cm×20cm or 10cm×10cm depending on the maximum field size for each option) at isocenter and at 20cm upstream and downstream of isocenter, and in-air profiles with a half-beam blocked aperture at isocenter and at 20cm upstream and downstream of isocenter. For all Monte-Carlo simulations,.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NASA Tech Briefs, November 2008

Topics covered include: Digital Phase Meter for a Laser Heterodyne Interferometer; Vision System Measures Motions of Robot and External Objects; Advanced Precipitation Radar Antenna to Measure Rainfall From Space; Wide-Band Radar for Measuring Thickness of Sea Ice; Vertical Isolation for Photodiodes in CMOS Imagers; Wide-Band Microwave Receivers Using Photonic Processing; L-Band Transmit/Receive Module for Phase-Stable Array Antennas; Microwave Power Combiner/Switch Utilizing a Faraday Rotator; Compact Low-Loss Planar Magic-T; Using Pipelined XNOR Logic to Reduce SEU Risks in State Machines; Quasi-Optical Transmission Line for 94-GHz Radar; Next Generation Flight Controller Trainer System; Converting from DDOR SASF to APF; Converting from CVF to AAF; Documenting AUTOGEN and APGEN Model Files; Sequence History Update Tool; Extraction and Analysis of Display Data; MRO DKF Post-Processing Tool; Rig Diagnostic Tools; MRO Sequence Checking Tool; Science Activity Planner for the MER Mission; UAVSAR Flight-Planning System; Templates for Deposition of Microscopic Pointed Structures; Adjustable Membrane Mirrors Incorporating G-Elastomers; Hall-Effect Thruster Utilizing Bismuth as Propellant; High-Temperature Crystal-Growth Cartridge Tubes Made by VPS; Quench Crucibles Reinforced with Metal; Deep-Sea Hydrothermal-Vent Sampler; Mars Rocket Propulsion System; Two-Stage Passive Vibration Isolator; Improved Thermal Design of a Compression Mold; Enhanced Pseudo-Waypoint Guidance for Spacecraft Maneuvers; Altimetry Using GPS-Reflection/Occultation Interferometry; Thermally Driven Josephson Effect; Perturbation Effects on a Supercritical C7H16/N2 Mixing Layer; Gold Nanoparticle Labels Amplify Ellipsometric Signals; Phase Matching of Diverse Modes in a WGM Resonator; WGM Resonators for Terahertz-to-Optical Frequency Conversion; Determining Concentration of Nanoparticles from Ellipsometry; Microwave-to-Optical Conversion in WGM Resonators; Four-Pass Coupler for Laser-Diode-Pumped Solid-State Laser; Low-Resolution Raman-Spectroscopy Combustion Thermometry; Temperature Sensors Based on WGM Optical Resonators; Varying the Divergence of Multiple Parallel Laser Beams; Efficient Algorithm for Rectangular Spiral Search; Algorithm-Based Fault Tolerance Integrated with Replication; Targeting and Localization for Mars Rover Operations; Terrain-Adaptive Navigation Architecture; Self-Adjusting Hash Tables for Embedded Flight Applications; Schema for Spacecraft-Command Dictionary; Combined GMSK Communications and PN Ranging; System-Level Integration of Mass Memory; Network-Attached Solid-State Recorder Architecture; Method of Cross-Linking Aerogels Using a One-Pot Reaction Scheme; An Efficient Reachability Analysis Algorithm.

Source record↗

Performance prediction applying different reduced turbulence models to the SMART tokamak

The SMall Aspect Ratio Tokamak (SMART) is currently being commissioned at the University of Seville and will be able to compare the performance of positive and negative triangularity plasmas at low aspect ratio. Predictive simulations have been performed for different machine scenarios and heating schemes using the TRANSP code. The objectives of these simulations are to predict the parameters expected in positive triangularity plasmas, to guide diagnostic development, and to validate transport models. Several reduced turbulence models have been used to predict electron and ion temperatures for the operational phase 2. All models provide similar results from approximately mid-radius to the separatrix but important discrepancies are found in the core region. These positive triangularity results are compared with experiments from a similar size machine like GLOBUS-M2. The multi-mode model (MMM) shows the best agreement. Simulations with different boundary conditions have been performed and no strong differences have been observed between them. The impact of neutral beam injection (NBI) on the predicted profiles has also been addressed. Rotation reduces turbulence levels so higher temperatures are achieved when included in the simulations. Studying the different contributions to the thermal diffusivities, it is observed that electron temperature gradient (ETG) turbulence dominates at the plasma core while micro-tearing modes (MTM) dominate at the edge in the electron channel. In the ion channel, the neoclassical contribution is dominant at the core and at the very edge while the Weiland component, which includes ion temperature gradient mode (ITG), trapped electron mode (TEM), kinetic ballooning mode (KBM), peeling mode (PM) and collisionless and collision dominated magnetohydrodynamic (MHD) modes governs the mid-radius region. For phase 3, two plasmas with different electron densities have been studied. The case with lower density matches well a specific discharge of GLOBUS-M2. The higher density plasma shows high performance with β N ≈ 3.8.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Poster — Thur Eve — 56: Design of Quality Assurance Methodology for VMAT system on Agility System equipped with CVDR

The aim of this study was to analyze the feasibility of designing comprehensive QA plans using iComCAT for Elekta machines equipped with Agility multileaf collimator and continuously variable dose rate. Test plans with varying MLC speed, gantry speed, and dose rate were created and delivered in a controlled manner. A strip test was designed with three 1 cm MLC positions and delivered using dynamic, StepNShoot and VMAT techniques. Plans were also designed to test error in MLC position with various gantry speeds and various MLC speeds. The delivery fluence was captured using the electronic portal-imaging device. Gantry speed was found to be within tolerance as per the Canadian standards. MLC positioning errors at higher MLC speed with gravity effects does add more than 2 mm discrepancy. More tests need to be performed to evaluate MLC performance using independent measurement systems. The treatment planning system with end-to-end testing necessary for commissioning was also investigated and found to have >95% passing rates within 3%/3mm gamma criteria. Future studies involve performing off-axis gantry starshot pattern and repeating the tests on three matched Elekta linear accelerators.

07 ISOTOPE AND RADIATION SOURCES↗

Results from the Radio Frequency Mass Gauge Technology Demonstration on the Intuitive Machines Nova-C Lunar Lander

A cryogenic propellant mass gauge known as the Radio Frequency Mass Gauge (RFMG) was integrated into the Intuitive Machines (IM) Nova-C lunar lander and provided an estimate of the liquid oxygen and liquid methane mass in the lander propellant tanks throughout the IM-1 mission, including during microgravity coast phases. An RFMG electronics controller was used to measure and record the spectrum of the RF signal reflected from an antenna sensor in each tank over the frequency range 100 to 1,300 MHz. The RF spectrum of each of the tanks is unique and is sensitive to the index of refraction of the propellants and the spatial distribution of the liquid within the tanks. Electromagnetic simulation software was used to simulate the antenna response spectra for a given tank geometry, fluid properties, and liquid–vapor configurations within the tank. Over 10,000 antenna response simulations were completed for each propellant tank prior to the IM-1 mission and represented various volumetric fill levels and fluid configurations. The simulated spectra served as a database against which measured tank spectra were compared. For analysis, a spectral matching algorithm was used to find the best match between measured and simulated spectra, and the gauged mass was calculated from the most highly correlated fluid mass simulations. RFMG measurements were recorded during tank loading on the launch pad and during translunar coast, lunar orbit insertion, low lunar orbit, powered descent to the lunar surface, and postlanding on the Moon. This paper describes the RF and fluid simulations, the RFMG measurements and analysis of spectral data, the RFMG instrument, and the gauged results throughout all phases of the IM-1 mission.

lunar lander↗

Results from the Radio Frequency Mass Gauge Technology Demonstration on the Intuitive Machines Nova-C Lunar Lander

A cryogenic propellant mass gauge known as the Radio Frequency Mass Gauge (RFMG) was integrated into the Intuitive Machines (IM) Nova-C lunar lander and provided an estimate of the liquid oxygen and liquid methane mass in the lander propellant tanks throughout the IM-1 mission, including during microgravity coast phases. An RFMG electronics controller was used to measure and record the spectrum of the RF signal reflected from an antenna sensor in each tank over the frequency range 100 to 1,300 MHz. The RF spectrum of each of the tanks is unique and is sensitive to the index of refraction of the propellants and the spatial distribution of the liquid within the tanks. Electromagnetic simulation software was used to simulate the antenna response spectra for a given tank geometry, fluid properties, and liquid–vapor configurations within the tank. Over 10,000 antenna response simulations were completed for each propellant tank prior to the IM-1 mission and represented various volumetric fill levels and fluid configurations. The simulated spectra served as a database against which measured tank spectra were compared. For analysis, a spectral matching algorithm was used to find the best match between measured and simulated spectra, and the gauged mass was calculated from the most highly correlated fluid mass simulations. RFMG measurements were recorded during tank loading on the launch pad and during translunar coast, lunar orbit insertion, low lunar orbit, powered descent to the lunar surface, and postlanding on the Moon. This paper describes the RF and fluid simulations, the RFMG measurements and analysis of spectral data, the RFMG instrument, and the gauged results throughout all phases of the IM-1 mission.

lunar lander↗

A double bend achromat lattice for the Pohang Light Source to reduce emittance and increase number of insertion devices

The Pohang Light Source (PLS) storage ring is a synchrotron light source with the emittance of 18.9 nm at 2.5 GeV and has delivered vacuum ultraviolet and soft x-rays during the past 15 years. We investigate a lattice design for the 3 GeV ring for an upgrade project that keeps the existing tunnel. We investigate a double bend achromat (DBA) structure that provides the reduction of emittance by a factor of 3 and the increase of the number of straight section by a factor of 2 than the existing PLS lattice. We present several characteristics on the beam dynamics, dynamic aperture, and optics matching in the low-emittance lattice which includes squeezed space between magnets. Present PLS lattice has 12 long straight sections of 6.8 m long and the lattice is modified to provide the additional 12 short straight sections of 3.7 m long by eliminating a bending magnet in the middle of the cell of the present triplet bending achromat lattice. Thus, the new lattice consists of a total of 24 straight sections that consist of 12x6.8 and 12x3.7 m long straight sections, which can provide the spaces for the 4- and 2-m-long insertion devices. We present the design results in detail for a DBA lattice in 281.82 m long circumference. It is shown that the emittance of 6.2 nm in the lattice can be achieved by allowing nonzero dispersions in the straight sections. The lattice provides high brilliance at the photon energy of a few 10 keV that meets the requirements by synchrotron radiation users; however, it may require a strong focusing and become sensitive to machine errors and effects of insertion devices. Thus, we investigated the dynamic aperture in the lattice by a simulation method and achieved an optimal tune under the strength of sextupole magnets of 500 T/m{sup 2} for the low-emittance ring. We also performed the lattice tunings to restore the optics due to the errors in the low-emittance ring. In result, our designed lattice shows a good optimization in terms of emittance, brilliance, and circumference as a light source for a 3 GeV.

43 PARTICLE ACCELERATORS↗

Generalized analytical and numerical modeling of optical second harmonic generation in anisotropic crystals and complex heterostructures using #SHAARP package

Optical second harmonic generation (SHG) is a nonlinear optical effect widely used for nonlinear optical microscopy and laser frequency conversion. The closed-form analytical solution of the nonlinear optical responses is essential for evaluating the optical responses of new materials whose optical properties are unknown a priori. Many approximations have therefore been employed in the existing analytical approaches, such as slowly varying approximation, weak reflection of the nonlinear polarization, transparent medium, high crystallographic symmetry, Kleinman symmetry, easy crystal orientation along a high-symmetry direction, phase matching conditions and negligible interference among nonlinear waves, which may lead to large errors in the reported material properties. To avoid these approximations, here we have developed an open-source package named Second Harmonic Analysis of Anisotropic Rotational Polarimetry (#SHAARP) for single interface (si) and in multilayers (ml) for homogeneous crystals. The reliability and accuracy are established by experimentally benchmarking with both the SHG polarimetry and Maker fringes predicted from the package using standard materials. SHAARP.si and SHAARP.ml are available through GitHub https://github.com/Rui-Zu/SHAARP and https://github.com/bzw133/SHAARP.ml, respectively.

complex systems↗

A micro-scale cutting model for UD CFRP composites with thermo-mechanical coupling

Cutting a unidirectional carbon fiber-reinforced polymer (UD CFRP) structure is the basic unit for CFRP machining, which is a complex thermal-mechanically coupled process. To reveal the deformation mechanism and predict cutting force in UD CFRP micro cutting, a micro-scale fracture model for UD CFRP cutting with thermal-mechanical coupling is demonstrated in this paper, which captures the failure modes for fibers, matrix and the interface based on a micro-level RVE using a relatively simple damage based fracture method. The thermal-mechanical coupling model at the micro scale is developed on the basis of the plastic energy dissipation and frictional heating during cutting. Failure models for the fiber, matrix and interface region are applied depending on the material properties of each of these three phases. Numerical simulations based on the above model with different fiber orientations were performed to predict the deformation and forces of different components in UD CFRP. Cutting experiments with the same fiber orientations as considered in the simulations were carried out to validate the force and deformation results. The predicted force and deformation patterns match well with evidence from our experiments. In general, the cutting force is larger than the thrust force regardless of fiber orientation. The cutting force reaches a maximum as the fiber orientation approaches 90 , but thrust forces do not vary substantially across cases. When the fiber orientation is acute, the deformation of fibers is much smaller than when the cutting angle is obtuse. Surface roughness follows the same trend with cutting angle as fiber deformation.

42 ENGINEERING↗

Methods for estimating X-ray machine output through measurement and simulation

We report ball grid arrays are increasingly being applied in the electronics industry and may require X-ray inspection to ensure the integrity and correct placement of solder pins. However, as the architecture of integrated circuits continues to narrow while simultaneously growing more complex, the risk of electronic failure due to radiation damage increases. While medical X-ray devices have been held to high standards and are repeatedly shown to be well characterized, devices used for electronic inspection are often lacking detailed characterization. This study presents unique methods to solve for important properties in X-ray inspection devices such as source to object distance and energy spectrum. This information can then be applied to Monte Carlo models to achieve better overall dose estimates to electronics, which will lead to superior manufactured products. Since X-ray devices can vary greatly in source characteristics, this work investigates spectral measurement and Monte Carlo representation of three X-ray devices. For a Philips SRO 33 100 medical diagnostic device, the spectral output followed expected trends given by the prediction software SpekCalc and Spektr. For the Dage XD7500NT, direct measurement showed a spectral artifact that through the use of Gafchromic films, was shown to be a contributing effect in the dose output. For the Rad Source RS1800, a high powered irradiation device, direct spectral measurement was not achieved. However, a Monte Carlo model using an assumed spectra was found to match ion chamber measurements to a high degree.

47 OTHER INSTRUMENTATION↗

Large-scale tearing-mode hazard function analysis with standard matched equilibrium reconstructions

The association between features from standard tokamak equilibrium reconstructions and the onset of n = 1 tearing modes (TMs) is analyzed at scale. The TM onset rate is directly modeled with a ‘hazard’ function which gives the expected number of onsets (per unit time spent) in a given equilibrium parameter region. In particular the different statistical modeling performance achieved for magnetics-only reconstructions and motional Stark effect (MSE) enhanced reconstructions is studied. It is observed that a better hazard model for the TM onset rate can be built with the MSE-enhanced equilibria compared to the matched magnetics-only situation. This advantage disappears if internal profile details are withheld from the matched analysis. Plausibility of the hazard function is further demonstrated with visualizations of global trends in the operational space, and time-traces from specific tokamak discharges. As a result, TMs typically degrade tokamak plasma performance and may lead to plasma termination, motivating this statistical study.

equilibrium↗