At least 685 records · Page 38

Optical and Laser-based Measurements for NASA’s Artemis Program

NASA and their partners have embarked on a series of space missions to the moon and beyond, collectively known as the Artemis Program. The Artemis I mission occurred in November 2022. This talk briefly summarizes the upcoming Artemis missions and describes laser and optical measurement technique development and application to ground and flight tests related to, or inspired by, the Artemis program. In particular, development and application of three different measurement techniques (planar laser-induced fluorescence [PLIF], femtosecond laser electronic excitation and tagging [FLEET] and photogrammetry) are described. These techniques have been applied to study vehicle launch, lunar landing, and earth entry. Such optical and laser-based instrumentation can provide unique qualitative and quantitative information to inform the underlying physics of space flight while also providing benchmark data for validating ever advancing predictive codes.

Artemis Program↗

Workload: Measurement and Management

Poster: The workload research project has as its task to survey the available literature on: (1) workload measurement techniques; and (2) the effects of workload on operator performance. The first set of findings provides practitioners with a collection of simple-to-use workload measurement techniques along with characterizations of the kinds of tasks each technique has been shown reliably address. This allows design practitioners to select and use the most appropriate techniques for the task(s) at hand. The second set of findings provides practitioners with the guidance they need to design for appropriate kinds and amounts of workload across all tasks for which the operator is responsible. This guidance helps practitioners design systems and procedures that ensure appropriate levels of engagement across all tasks, and avoid designs and procedures that result in operator boredom, complacency, loss of awareness, undue levels of stress, or skill atrophy that can result from workload that distracts operators from the tasks they perform and monitor, workload levels that are too low, too high, or too consistent or predictable. Only those articles that were peer reviewed, long standing and generally accepted in the field, and applicable to a relevant range of conditions in a select domain of interest, in analogous "extreme" environments to those in space were included. In addition, all articles were reviewed and evaluated on uni-dimensional and multi-dimensional considerations. Casner & Gore also examined the notion of thresholds and the conditions that may benefit mostly from the various methodological approaches. Other considerations included whether the tools would be suitable for guiding a requirement-related and design-related question. An initial review of over 225 articles was conducted and entered into an EndNote database. The reference list included a range of conditions in the domain of interest (subjective/objective measures), the seminal works in workload, as well as summary works

Gore, Brian Francis↗

Local Measurement of Tropospheric HO(x)

In March of 1992 a workshop sponsored by NASA and NSF was held at SRI International to assess the current ability to measure atmospheric OH and HO2. The measurement techniques reviewed during the workshop for detection of OH included five laser-induced fluorescence schemes, five laser-based adsorption techniques, and four non-laser methods. Six instruments or instrument concepts for HO2 detection, including chemical amplification, conversion to OH with subsequent OH detection, or direct spectroscopic detection of the HO2 were also discussed. The conclusions from the workshop identify several measurement techniques for OH and HO2 that are ready for field tests. These have the ability to measure the radicals with sufficient sensitivity and accuracy to form meaningful comparison with atmospheric model predictions. The workshop conclusions also include recommendations for informal and formal intercomparison protocols.

Crosley, David R.↗

General technique for measurement of refractive index variations

Time variation of amplitude and phase fluctuations, impressed on waves propagating through a medium which has a randomly varying refractive index, is used to examine isolated regions along the line of propagation. Technique employs only one antenna at each end of the line.

Source record↗

Mars Extant Life: What's Next? Conference Report

On November 5–8, 2019, the ‘‘Mars Extant Life: What’s Next?’’ conference was convened in Carlsbad, New Mexico. The conference gathered a community of actively publishing experts in disciplines related to habitability and astrobiology. Primary conclusions are as follows: A significant subset of conference attendees concluded that there is a realistic possibility that Mars hosts indigenous microbial life. A powerful theme that permeated the conference is that the key to the search for martian extant life lies in identifying and exploring refugia (‘‘oases’’), where conditions are either permanently or episodically significantly more hospitable than average. Based on our existing knowledge of Mars, conference participants highlighted four potential martian refugium (not listed in priority order): Caves, Deep Subsurface, Ices, and Salts. The conference group did not attempt to reach a consensus prioritization of these candidate environments, but instead felt that a defensible prioritization would require a future competitive process. Within the context of these candidate environments, we identified a variety of geological search strategies that could narrow the search space. Additionally, we summarized a number of measurement techniques that could be used to detect evidence of extant life (if present). Again, it was not within the scope of the conference to prioritize these measurement techniques—that is best left for the competitive process. We specifically note that the number and sensitivity of detection methods that could be implemented if samples were returned to Earth greatly exceed the methodologies that could be used at Mars. Finally, important lessons to guide extant life search processes can be derived both from experiments carried out in terrestrial laboratories and analog field sites and from theoretical modeling.

79 ASTRONOMY AND ASTROPHYSICS↗

New methods to detect particle velocity and mass flux in arc-heated ablation/erosion facilities

Arc-heated flow facilities with injected particles are used to simulate the erosive and ablative/erosive environments encountered by spacecraft re-entry through fog, clouds, thermo-nuclear explosions, etc. Two newly developed particle diagnostic techniques used to calibrate these facilities are discussed. One technique measures particle velocity and is based on the detection of thermal radiation and/or chemiluminescence from the hot seed particles in a model ablation/erosion facility. The second technique measures a local particle rate, which is proportional to local particle mass flux, in a dust erosion facility by photodetecting and counting the interruptions of a focused laser beam by individual particles.

Brayton, D. B.↗

Exploratory evaluation of a moving-model technique for measurement of dynamic ground effects

An attempt is presently made to measure the dynamic or time-dependent ground effects that may be encountered by aircraft during approach and landing by means of a ground-based testing technique that employs a model moving horizontally over an upwardly inclined ground plane to simulate the rate of descent. Results have been thus obtained for a 60-deg delta wing and for an F-18 full configuration, with and without thrust reversal, at forward speeds of up to 100 ft/sec. An analysis of the results gathered indicates that ground effects were reduced when the rate of descent was included in the test conditions.

Kemmerly, Guy T.↗

On-line technique for measuring stable oxygen and hydrogen isotopes from microliter quantities of water

Detailed here is a method for extracting and analyzing oxygen and hydrogen isotopes from 10 microL-sized water samples. Based on the traditional CO2-H2O equilibration technique, the oxygen isotope exchange reaction is done exclusively in sealed 6-mm (o.d.) Pyrex tubes at 25 degrees C, with full isotope exchange completed in at least 28 h. Using the same water sample employed in the 18O equilibration, D/H extractions are done in separate sealed 6-mm (o.d.) Pyrex tubes by reaction with Zn at 450 degrees C to form H2(g). Provided that a correction factor is applied to 18O analyses, accuracy and precision for both 18O and D/H are comparable to standard techniques using much larger samples.

NASA Center JSC↗

MAS-CCD: New technique for measuring low-level charge content based on the multiple amplifier architecture

Low-noise detectors are a key technology for the next generation of astronomical instruments aimed at spectroscopy of faint objects and the search for exoplanets. In this context, the multiple-amplifier sensing charge-coupled device (MAS-CCD) emerges as a promising technology for future scientific instruments. A critical parameter affecting the performance of these devices is spurious charge, produced by the clocking of the gates. Its measurement is typically challenging with existing methods. In practice, the optimization of this parameter often relies on empirical procedures that require significant time and careful consideration of the trade-off with full-well capacity. In this work, we present a new technique to estimate spurious charge based on covariance analysis of the output amplifiers of the MAS-CCD, which measures the same charge packet in different amplifiers at different times. The method enables fast and precise measurements of spurious charge under operating conditions where conventional approaches are difficult to apply. We develop the theoretical framework of the method and validate the model through simulations. The results demonstrate the feasibility of this approach and suggest that it could serve as a basis for reliable large-scale characterization of sensor performance.

Gamero, Miqueas E. [Buenos Aires, CONICET; Fermila↗

Engineering solar cells based on correlative X-ray microscopy

In situ and operando measurement techniques combined with nanoscale resolution have proven invaluable in multiple fields of study. We argue that evaluating device performance as well as material behavior by correlative X-ray microscopy with <100 nm resolution can radically change the approach for optimizing absorbers, interfaces and full devices in solar cell research. Here, we thoroughly discuss the measurement technique of X-ray beam induced current and point out fundamental differences between measurements of wafer-based silicon and thin-film solar cells. Based on reports of the last years, we showcase the potential that X-ray microscopy measurements have in combination with in situ and operando approaches throughout the solar cell lifecycle: from the growth of individual layers to the performance under operating conditions and degradation mechanisms. Enabled by new developments in synchrotron beamlines, the combination of high spatial resolution with high brilliance and a safe working distance allows for the insertion of measurement equipment that can pave the way for a new class of experiments. When applied to photovoltaics research, we highlight today’s opportunities and challenges in the field of nanoscale X-ray microscopy, and give an outlook on future developments.

36 MATERIALS SCIENCE↗

Analysis of the density field around a supersonic conical projectile using quantitative schlieren

Quantitative schlieren imaging is a flow measurement technique that is capable of measuring density fields throughout refractive flowfields. The technique was applied here to measure the density field surrounding supersonic conical projectiles in free flight. Shock waves attached to a supersonic conical projectile offer a simple geometry with the well-established Taylor–Maccoll analytical flow solution to which these experimental measurements were compared. The schlieren images recorded a projection of the index of refraction field surrounding the 10° half-angle cones which was converted to density first through an Abel inversion and then the Gladstone–Dale law. Three Abel inversion methods—two-point, three-point, and arbitrary ray axisymmetric projection (ARAP)—were applied to deconvolute the three-dimensional flow within the constrained axisymmetric flow field. The resulting reconstructed density profiles were compared to the Taylor–Maccoll solution, parameterized by cone geometry and Mach number. The experimental density fields demonstrated strong agreement with the theoretical profiles. Experimental consistency was confirmed across various projectile speeds, demonstrating quantitative schlieren’s capability to accurately reconstruct the density of the flow field, even within the resolution constraints imposed by high-speed imaging. In conclusion, an assessment of experimental uncertainties in the density reconstruction was performed.

Abel Inversion↗

Impact of new instrumentation on advanced turbine research

A description is presented of an orderly test program that progresses from the simplest stationary geometry to the more complex, three dimensional, rotating turbine stage. The instrumentation requirements for this evolution of testing are described. The heat transfer instrumentation is emphasized. Recent progress made in devising new measurement techniques has greatly improved the development and confirmation of more accurate analytical methods for the prediction of turbine performance and heat transfer. However, there remain challenging requirements for novel measurement techniques that could advance the future research to be done in rotating blade rows of turbomachines.

Graham, R. W.↗

Robust Technique for Measuring and Simulating Silicon Wafer Quality Characteristics that Enable the Prediction of Solar Cell Electrical Performance of MEMC Silicon Wafer. Cooperative Research and Development Final Report, CRADA Number CRD-11-438

NREL and MEMC Electronic Materials are interested in developing a robust technique for monitoring material quality of mc-Si and mono-Si wafers -- a technique that can provide relevant data to accurately predict the performance of solar cells fabricated on them. Previous work, performed under two TSAs between NREL and MEMC, has established that dislocation clusters are the dominant performance-limiting factor in MEMC mc-Si solar cells. The work under this CRADA will go further in verifying these results on a larger data set, evaluate possibilities of faster method(s) for mapping dislocations in wafers/ingots, understanding dislocation generation during ingot casting, and helping MEMC to have an internal capability for basic characterization that will provide feedback needed for more accurate crystallization simulations. NREL has already developed dislocation mapping technique and developed a basic electronic model (called Network Model) that uses spatial distribution of dislocations to predict the cell performance. In this CRADA work, we will use these techniques to: (i) establish dislocation, grain size, and grain orientation distributions of the entire ingots (through appropriate DOE) and compare these with theoretical models developed by MEMC, (ii) determine concentrations of some relevant impurities in selected wafers, (iii) evaluate potential of using photoluminescence for dislocation mapping and identification of recombination centers, (iv) evaluate use of diode array analysis as a detailed characterization tool, and (v) establish dislocation mapping as a wafer-quality monitoring tool for commercial mc-Si production.

14 SOLAR ENERGY↗

A technique for measuring magnetic fields on solar-type stars

A method is developed and tested by which magnetic-field strengths and area filling-factors of magnetic regions on late-type stars may be inferred from high-resolution, absorption-line profiles that have been broadened by the Zeeman effect. The technique involves fitting such profiles with a triplet of components, the shape of which is derived from profiles of lines of low Zeeman sensitivity. Tests of the systematic and random errors indicate that such magnetic flux measurements have an uncertainty of 20% for stars with field strengths of 2000 gauss if at least 10% of the stellar surface contains magnetic regions.

Marcy, G. W.↗

Multi-hole gasoline direct injection:In-nozzle flow and primary breakup investigated in transparent nozzlesand with X-ray

This contribution describes the flow field inside modern gasoline direct-injection nozzles and sprays. Starting from the internal nozzle flow, results from transparent real-size nozzles are shown, where a significant vapor fraction even for cold fuel conditions is proven. Based on vapor fraction inside the nozzle, evidence for (super-)sonic flow conditions inside the nozzle is shown. The nozzle outlet velocity is determined by means of X-ray structure tracking velocimetry, which is a very powerful measurement technique to gain access to the very dense spray at the nozzle outlet. The X-ray velocities are compared to values that are determined by means of optical—phase Doppler anemometry/laser Doppler anemometry and Schlieren imaging—measurement techniques. By extrapolating the maximum droplet velocities found by laser Doppler anemometry in the more downstream regions of the spray to the nozzle outlet region, very similar velocities to the one derived from the X-ray measurements close to Bernoulli velocity are evaluated for typical gasoline direct-injection engine conditions. A third access to the nozzle outlet velocity is given by the derivation of penetration curves. The combination of vapor fractions and outlet velocities provides a measure for the initial spray momentum.

42 ENGINEERING↗

Implementation of In-Situ Impedance Techniques on a Full Scale Aero-Engine System

Determination of acoustic liner impedance for jet engine applications remains a challenge for the designer. Although suitable models have been developed that take account of source amplitude and the local flow environment experienced by the liner, experimental validation of these models has been difficult. This is primarily due to the inability of researchers to faithfully mimic the environment in jet engine nacelles in the laboratory. An in-situ measurement technique, one that can be implemented in an actual engine, is desirable so an accurate impedance can be determined for future modeling and quality control. This paper documents the implementation of such a local acoustic impedance measurement technique that is used under controlled laboratory conditions as well as on full scale turbine engine liner test article. The objective for these series of in-situ measurements is to substantiate treatment design, provide understanding of flow effects on installed liner performance, and provide modeling input for fan noise propagation computations. A series of acoustic liner evaluation tests are performed that includes normal incidence tube, grazing incidence tube, and finally testing on a full scale engine on a static test stand. Lab tests were intended to provide insight and guidance for accurately measuring the impedance of the liner housed in the inlet of a Honeywell Tech7000 turbofan. Results have shown that one can acquire very reasonable liner impedance data for a full scale engine under realistic test conditions. Furthermore, higher fidelity results can be obtained by using a three-microphone coherence technique that can enhance signal-to-noise ratio at high engine power settings. This research has also confirmed the limitations of this particular type of in-situ measurement. This is most evident in the installation of instrumentation and its effect on what is being measured.

Gaeta, R. J.↗

GUINEVERE experiment: Kinetic analysis of some reactivity measurement methods by deterministic and Monte Carlo codes

The GUINEVERE experiment (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) is an experimental program in support of the ADS technology presently carried out at SCK-CEN in Mol (Belgium). In the experiment a modified lay-out of the original thermal VENUS critical facility is coupled to an accelerator, built by the French body CNRS in Grenoble, working in both continuous and pulsed mode and delivering 14 MeV neutrons by bombardment of deuterons on a tritium-target. The modified lay-out of the facility consists of a fast subcritical core made of 30% U-235 enriched metallic Uranium in a lead matrix. Several off-line and on-line reactivity measurement techniques will be investigated during the experimental campaign. This report is focused on the simulation by deterministic (ERANOS French code) and Monte Carlo (MCNPX US code) calculations of three reactivity measurement techniques, Slope ({alpha}-fitting), Area-ratio and Source-jerk, applied to a GUINEVERE subcritical configuration (namely SC1). The inferred reactivity, in dollar units, by the Area-ratio method shows an overall agreement between the two deterministic and Monte Carlo computational approaches, whereas the MCNPX Source-jerk results are affected by large uncertainties and allow only partial conclusions about the comparison. Finally, no particular spatial dependence of the results is observed in the case of the GUINEVERE SC1 subcritical configuration. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wire Crimp Connectors Verification using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp connections is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp connector and wire is shown to correlate with the results of a destructive pull test, which previously has been used to assess crimp wire junction quality. Various crimp junction pathologies (missing wire strands, incorrect wire gauge, incomplete wire insertion in connector) are ultrasonically tested, and their results are correlated with pull tests. Results show that the ultrasonic measurement technique consistently (as evidenced with pull-testing data) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying the technique while wire crimps are installed is also presented.

Cramer, K. Elliott↗