Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Vertically stratified two-phase flow in a curved channel: Insights from a domain perturbation analysis

In this work, we investigate the fully developed flow field of two vertically stratified fluids (one phase flowing above the other) in a curved channel of rectangular cross section. The domain perturbation technique is applied to obtain an analytical solution in the asymptotic limit of low Reynolds numbers and small curvature ratios (the ratio of the width of the channel to its radius of curvature). The accuracy of this solution is verified by comparison with numerical simulations of the nonlinear equations. The flow is characterized by helical vortices within each fluid, which are driven by centrifugal forces. The number of vortices and their direction of circulation varies with the parameters of the system (the volume fraction, viscosity ratio, and Reynolds numbers). We identify nine distinct flow patterns and organize the parameter space into corresponding flow regimes. We show that the fully developed interface between the fluids is not horizontal, in general, but is deformed by normal stresses associated with the circulatory flow. The results are especially significant for flows in microchannels, where the Reynolds numbers are small. The mathematical results in this paper include an analytical solution to two coupled biharmonic partial differential equations; these equations arise in two-phase, two-dimensional Stokes flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new ion sensing deep atomic force microscope

Here we describe a new deep atomic force microscope (AFM) capable of ion sensing. A novel probe assembly incorporates a micropipette that can be used both for sensing ion currents and as the tip for AFM imaging. The key advance of this instrument over previous ion sensing AFMs is that it uses conventional micropipettes in a novel suspension system. This paper focuses on sensing the ion current passively while using force feedback for the operation of the AFM in contact mode. Two images are obtained simultaneously: (1) an AFM topography image and (2) an ion current image. As an example, two images of a MEMS device with a microchannel show peaks in the ion current as the pipette tip goes over the edges of the channel. This ion sensing AFM can also be used in other modes including tapping mode with force feedback as well as in non-contact mode by utilizing the ion current for feedback, as in scanning ion conductance microscopy. The instrument is gentle enough to be used on some biological samples such as plant leaves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chaotic mixing in a planar, curved channel using periodic slip

We propose a novel strategy for designing chaotic micromixers using curved channels confined between two flat planes. The location of the separatrix between the Dean vortices, induced by centrifugal forces, is dependent on the location of the maxima of axial velocity. An asymmetry in the axial velocity profile can change the location of the separatrix. This is achieved physically by introducing slip alternatingly at the top and bottom walls. This leads to streamline crossing and Lagrangian chaos. An approximate analytical solution of the velocity field is obtained using perturbation theory. This is used to find the Lagrangian trajectories of fluid particles. Poincare sections taken at periodic locations in the axial direction are used to study the extent of chaos. We study two microchannel designs, called circlet and serpentine, in which the Dean vortices in adjacent half cells are co-rotating and counter-rotating, respectively. The extent of mixing, at low Re and low slip length, is shown to be greater in the serpentine case. Wide channels are observed to have much better mixing than tall channels; an important observation not made for separatrix flows till now. Eulerian indicators are used to gauge the extent of mixing, with varying slip length, and it is shown that an optimum slip length exists which maximizes the mixing in a particular geometry. Once the parameter space of relatively high mixing is identified, detailed variance computations are carried out to identify the detailed features.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum dot-based microfluidic biosensor for cancer detection

We report results of the studies relating to fabrication of an impedimetric microfluidic–based nucleic acid sensor for quantification of DNA sequences specific to chronic myelogenous leukemia (CML). The sensor chip is prepared by patterning an indium–tin–oxide (ITO) coated glass substrate via wet chemical etching method followed by sealing with polydimethylsiloxane (PDMS) microchannel for fluid control. The fabricated microfluidic chip comprising of a patterned ITO substrate is modified by depositing cadmium selenide quantum dots (QCdSe) via Langmuir–Blodgett technique. Further, the QCdSe surface has been functionalized with specific DNA probe for CML detection. The probe DNA functionalized QCdSe integrated miniaturized system has been used to monitor target complementary DNA concentration by measuring the interfacial charge transfer resistance via hybridization. The presence of complementary DNA in buffer solution significantly results in decreased electro-conductivity of the interface due to presence of a charge barrier for transport of the redox probe ions. The microfluidic DNA biosensor exhibits improved linearity in the concentration range of 10{sup −15} M to 10{sup −11} M.

60 APPLIED LIFE SCIENCES↗

Microfluidic volumetric flow determination using optical coherence tomography speckle: An autocorrelation approach

Functional modalities of Optical Coherence Tomography (OCT) based on speckle analysis are emerging in the literature. We propose a simple approach to the autocorrelation of OCT signal to enable volumetric flow rate differentiation, based on decorrelation time. Our results show that this technique could distinguish flows separated by 3 μl/min, limited by the acquisition speed of the system. We further perform a B-scan of gradient flow inside a microchannel, enabling the visualization of the drag effect on the walls.

42 ENGINEERING↗

Tracking of buried layers during plasma-assisted femtosecond laser drilling of compound targets

It was shown that drilling of multi-layered target placed in the air by tightly focused femtosecond laser radiation with high fluence (up to 1000 J/cm{sup 2}) can be monitored online using plasma-induced X-ray emission and second harmonic of incident laser radiation. The technique based on X-rays registration is appeared to be more flexible than the method based on detection of second harmonic since its accuracy depends crucially on the target type. We demonstrated that the X-ray signal clearly indicates the transition from one layer to another during the microdrilling of targets consisting of 2–4 layers of titanium foil when a laser beam is focused beneath the target surface at a depth comparable to the layer thickness. The diagnostics of microchannel production in the chicken eggshell was performed for the first time. It was found that the presence of albumen beneath the shell accounts for longtime generation of X-ray pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focal overlap gating in velocity map imaging to achieve high signal-to-noise ratio in photo-ion pump-probe experiments

We demonstrate a technique in velocity map imaging (VMI) that allows spatial gating of the laser focal overlap region in time resolved pump-probe experiments. This significantly enhances signal-to-noise ratio by eliminating background signal arising outside the region of spatial overlap of pump and probe beams. This enhancement is achieved by tilting the laser beams with respect to the surface of the VMI electrodes which creates a gradient in flight time for particles born at different points along the beam. By suitably pulsing our microchannel plate detector, we can select particles born only where the laser beams overlap. Furthermore, this spatial gating in velocity map imaging can benefit nearly all photo-ion pump-probe VMI experiments especially when extreme-ultraviolet light or X-rays are involved which produce large background signals on their own.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new electron-ion coincidence 3D momentum-imaging method and its application in probing strong field dynamics of 2-phenylethyl-N, N-dimethylamine

In this paper, we report the development of a new three-dimensional (3D) momentum-imaging setup based on conventional velocity map imaging to achieve the coincidence measurement of photoelectrons and photo-ions. This setup uses only one imaging detector (microchannel plates (MCP)/phosphor screen) but the voltages on electrodes are pulsed to push both electrons and ions toward the same detector. The ion-electron coincidence is achieved using two cameras to capture images of ions and electrons separately. The time-of-flight of ions and electrons are read out from MCP using a digitizer. We demonstrate this new system by studying the dissociative single and double ionization of PENNA (2-phenylethyl-N,N-dimethylamine). Finally, we further show that the camera-based 3D imaging system can operate at 10 kHz repetition rate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio response functions for Cherenkov-based neutron detectors

Neutron time-of-flight diagnostics at the NIF were of late outfitted with Cherenkov detectors. A fused silica radiator delivers sub-nanosecond response time and is optically coupled to a microchannel plate photomultiplier tube with gain from ~1 to 10 4 . Capitalizing on fast time response and gamma-ray sensitivity, these systems can provide better than 30 ps precision for measuring first moments of neutron distributions. Generation of ab initio instrument response functions (IRFs) is critical to meet the <1% uncertainty needed. A combination of Monte Carlo modeling, benchtop characterization, and in situ comparison is employed. Close agreement is shown between the modeled IRFs and in situ measurements using the NIF’s short-pulse advanced radiographic capability beams. First and second moments of neutron spectra calculated using ab initio IRFs agree well with established scintillator measurements. Next-step designs offer increased sensitivity and time-response.

47 OTHER INSTRUMENTATION↗

Superlinearity, saturation, and the PMT—Tailoring and calibration methodology for prompt radiation detectors

This work illustrates predominant measureable nonlinearities in photomultiplier tubes (PMTs) and introduces a controllable one called “Superlinearity,” signifying both a positive nonlinear response and the ability to extend linear operation by counteracting gain saturation mechanisms — charge depletion, space-charge field limitation, and secondary emission surface effects. Recognizing superlinearity and its effect on the temporal step response leads to a true definition of linearity, free of a small-signal linear assumption. Furthermore, given the prevalent use of glass microchannel-plate (MCP) PMTs in favor of a faster impulse response in spite of a small charge limit, we are motivated to examine their nonlinear amplitude response and deploy tailored gain bias string methods to fully harness the maximum linear gain as is usually done for transmissive metal mesh and reflective metal dynode PMTs. Our characterization methodology applies standard NIST-traceable calibrated laboratory equipment with absolute input-referenced techniques, examining step responses over many orders of magnitude in controlled illumination. By doing so, we quantitatively reveal the superlinearity strength independent of charge depletion, yielding true linear responsivity and effectively doubling the small-signal linear limit; this is very relevant to PMT modeling and charge deconvolution efforts. In conclusion, with further development, the tailoring strategies we introduce could be applied to MCP detectors, extracting all useful capillary charge with a significant improvement in large linear signal quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of GafChromic film for very high flux laser driven ion beams

We report on the calibration of GafChromic HD-v2 radiochromic film in the extremely high dose regime up to 100 kGy together with very high dose rates up to 7 × 10 11 Gy/s. The absolute calibration was done with nanosecond ion bunches at the Neutralized Drift Compression Experiment II particle accelerator at Lawrence Berkeley National Laboratory (LBNL) and covers a broad dose dynamic range over three orders of magnitude. We then applied the resulting calibration curve to calibrate a laser driven ion experiment performed on the BELLA petawatt laser facility at LBNL. Here, we reconstructed the spatial and energy resolved distributions of the laser-accelerated proton beams. The resulting proton distribution is in fair agreement with the spectrum that was measured with a Thomson spectrometer in combination with a microchannel plate detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relativistic laser driven electron accelerator using micro-channel plasma targets

We present an experimental demonstration of the efficient acceleration of electrons beyond 60MeV using micro-channel plasma targets. We employed a high-contrast, 2.5 J, 32 fs short pulse laser interacting with a 5 lm inner diameter, 300 lm long microchannel plasma target. The micro-channel was aligned to be collinear with the incident laser pulse, confining the majority of the laser energy within the channel. The measured electron spectrum showed a large increase in the cut-off energy and slope temperature when compared to that from a 2 lm flat Copper target, with the cutoff energy more than doubled and the total energy in electrons >5MeV enhanced by over 10 times. Three-dimensional particle-in-cell simulations confirm efficient direct laser acceleration enabled by the novel structure as the dominant acceleration mechanism for the high energy electrons. The simulations further reveal the guiding effect of the channel that successfully explains preferential acceleration on the laser/channel axis observed in experiments. Finally, systematic simulations provide scalings for the energy and charge of the electron pulses. Our results show that the micro-channel plasma target is a promising electron source for applications such as ion acceleration, Bremsstrahlung X-ray radiation, and THZ generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Coincidence Velocity Map Imaging Spectrometer for Ions and High-Energy Electrons to Study Inner-Shell Photoionization of Gas-Phase Molecules

We report on the design and performance of a double-sided coincidence velocity map imaging spectrometer optimized for electron-ion and ion-ion coincidence experiments studying inner-shell photoionization of gas-phase molecules with soft X-ray synchrotron radiation. The apparatus employs two microchannel plate detectors equipped with delay-line anodes for coincident, time- and position-resolved detection of photoelectrons and Auger electrons with kinetic energies up to 300 eV on one side of the spectrometer and photoions up to 25 eV per unit charge on the opposite side. We demonstrate its capabilities by measuring valence photoelectrons and ion spectra of neon and nitrogen and by studying channel-resolved photoelectron and Auger spectra along with fragment-ion momentum correlations for chlorine 2 p inner-shell ionization of cis - and trans -1,2-dichloroethene.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multi-layering of SU-8 exhibits distinct geometrical transitions from circular to planarized profiles

The negative tone photoresist SU-8 permits the creation of micrometer-scale structures by optical lithography. It is also the most used photoresist in soft lithography for the fast-prototyping of microfluidic devices. Despite its importance, the effect of capillary forces on SU-8 multi-layering onto topographical features has not been thoroughly studied. In particular, the profile of the added layer has not been examined in detail. The overlaying process exhibits a set of distinct behaviors, or regimes, depending on the relative thickness of the overlay and the underlying rectangular pattern. We demonstrate how capillary effects control the profile of multi-layer microchannels in a predictable manner. We derive a simple static model to describe the evolution of the overlay as a function of dimensionless geometric parameters. Our study provides a critical understanding of the parameters that govern multi-layer spin coating.

Sauzade, Martin↗

Plasma temperature measurement with a silicon photomultiplier (SiPM)

The temperature of a nonneutral plasma confined in a Penning–Malmberg trap can be determined by slowly lowering one side of the trap’s electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles escape the trap as a function of the barrier height. In many experiments, the escaping particles are directed toward a microchannel plate, and the resulting amplified charge is collected on a phosphor screen. The screen is used for imaging the plasma but can also be used as a Faraday cup (FC) for a temperature measurement. The sensitivity limit is then set by microphonic noise enhanced by the screen’s high-voltage bias. Alternately, a silicon photomultiplier (SiPM) can be employed to measure the charge via the light emitted from the phosphor screen. This decouples the signal from the microphonic noise and allows the temperature of colder and smaller plasmas to be measured than could be measured previously; this paper focuses on the advantages of a SiPM over a FC.

Hunter, E. D. (ORCID:0000000236242840)↗

Guiding light via slippery liquid-infused porous surfaces

Slippery liquid-infused porous surfaces (SLIPSs) have been explored for many applications, taking advantage of their highly non-wetting property. In this work, we explore the SLIPS as a cladding material for waveguiding. SLIPSs are prepared by infusing perfluoropolyether oil to hydrophobized nanoporous surfaces of silicon. Power loss and transmission efficiency of an HeNe laser (1.82 mW and 632.8 nm) with varying incident angles were measured through microchannels consisting of the SLIPSs as cladding layers (noil = 1.30) and water (nwater = 1.33) as a core, compared to other cladding types including a planar silicon surface and the nanoporous surfaces in hydrophilic (Wenzel state) and hydrophobic (Cassie–Baxter state) conditions with no oil infused. Agreeing with Snell's law, a total internal reflection occurs at the incident angle as high as 14° for the SLIPSs. The waveguide loss at 14° is only 1.8 dB/cm for the SLIPSs, while those for planar silicon, hydrophilic nanoporous, and hydrophobic nanoporous surfaces are 5.9, 7.4, and 4.9 dB/cm, respectively. The power transmission efficiency of the SLIPSs is independent of the porosity because the surfaces are fully covered with the oil layer, whereas those of hydrophilic and hydrophobic nanoporous surfaces, whose pores are filled with water and air, respectively, depend on the porosity. The significantly lower power loss and the insensitivity to the surface porosity are advantages of the SLIPSs over the other surfaces and can benefit in waveguiding applications such as optofluidics.

Asawa, Kaustubh (ORCID:0000000197142555)↗

Slicing Newton spheres with a two-camera 3D imaging system

We demonstrate a simple approach to achieve three-dimensional ion momentum imaging. The method employs two complementary metal–oxide–semiconductor cameras in addition to a standard microchannel plates/phosphor screen imaging detector. The two cameras are timed to measure the decay of luminescence excited by ion hits to extract the time of flight. The achieved time resolution is better than 10 ns, which is mainly limited by camera jitters. A better than 5 ns resolution can be achieved when the jitter is suppressed.

Chemistry↗