High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

Time Disciplined Non-PLL Active Synchronization for Grid Forming Inverters

Grid forming inverters (GFMIs) are a critical component of the future grid. One major challenge with GFMIs is synchronization. Currently, most research in GFMI synchronization is focused around specific transition types but this is only a subcategory of the possible events facing GFMIs. In this paper, we propose categorizing all possible synchronization events into four categories: (1) initial grid synchronization, (2) ride-through, (3) blackstart coordination, (4) grid reconnection coordination. By categorizing events, we can better compare and integrate different control strategies under specific test conditions as demonstrated in simulation. This paper's framework helps guide GFMI primary-level control design to further research towards the 100% inverter-dominant grid.

blackstart↗

Risk Analysis for Remote Operation of Microreactors

Microreactors are a subset of advanced nuclear reactors that can be factory fabricated, transportable, and self-regulating. They have the potential to be used in microgrids, rural and remote areas, or emergency response applications, replacing fossil fuel sources like diesel generators and enabling sustainable energy generation. In order to make microreactor operation cost-effective, it is likely that remote communications will be needed to reduce the number of personnel required to be on site. While remote operation of energy generation and other industrial control systems is common in other industries, it is not yet adopted in the nuclear community and has many perceived and actual risks. In this paper, the severity of the risks introduced by remote operations for microreactors are explored. The primary changes in the operations involve the addition of a remote communications network and a certification system for data and controls. These changes lend themselves to considerations of cyber risks, whether unintentional or adversarial, but the assessment considers not just cyber risks introduced, but also how physical and human factors-based risks will impact the remote operations system and change the overall risk profile. This initial assessment indicates that there are standard cyber and mitigation measures that can be put in place so the risk of doing remote operations does not dramatically increase compared to local operations. This evaluation is a critical step in the process of evaluating if remote operations of microreactors is a suitable solution to meet future sustainable grid needs

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

D–Q Impedance Based Stability Analysis and Parameter Design of Three-Phase Inverter-Based AC Power Systems

Small-signal stability is an important concern in three-phase inverter-based ac power systems. The impedance-based approach based on the generalized Nyquist stability criterion (GNC) can analyze the stability related with the medium and high-frequency modes of the systems. However,. the GNC involves the right-half-plane (RHP) pole calculation of return-ratio transfer function matrices, which cannot be avoided for stability analysis of complicated ac power systems. Therefore, it necessitates the detailed internal control information of the inverters, which is not normally available for commercial inverters. To address this issue, this paper introduces the component connection method (CCM) in the frequency domain for stability analysis in the synchronous d-q frame, by proposing a method of deriving the impedance matrix of the connection networks of inverter-based ac power systems. Demonstration on a two-area system and a microgrid shows that: The CCM-enabled approach can avoid the RHP pole calculation of return-ratio matrices and enables the stability analysis by using only the impedances of system components, which could be measured without the need for the internal information. A stability analysis method based on d-q impedances, the CCM, and the determinant-based GNC is also proposed to further simplify the analysis process. Inverter controller parameters can be designed as stability regions in parameter spaces, by repetitively applying the proposed stability analysis method. Simulation and experimental results verify the validity of the proposed stability analysis method and the parameter design approach.

42 ENGINEERING↗

CERTS Microgrid Laboratory Test Bed

CERTS Microgrid concept captures the emerging potential of distributed generation using a system approach. CERTS views generation and associated loads as a subsystem or a 'microgrid'. The sources can operate in parallel to the grid or can operate in island, providing UPS services. The system can disconnect from the utility during large events (i.e. faults, voltage collapses), but may also intentionally disconnect when the quality of power from the grid falls below certain standards. CERTS Microgrid concepts were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resynchronization method met all Institute of Electrical and Electronics Engineers Standard 1547 and power quality requirements. The electrical protection system was able to distinguish between normal and faulted operation. The controls were found to be robust under all conditions, including difficult motor starts and high impedance faults.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Isochronous Architecture-Based Voltage-Active Power Droop for Multi-Inverter Systems

This article proposes an isochronous architecture for parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter-based distributed energy resources (DERs). The isochronous framework obviates the need for an explicit regulation of the frequency while allowing for sharing of reactive power. The article shows that the detrimental effects of circulating currents between inverters can be addressed in the framework developed. The isochronous architecture is implemented by employing a GPS to disseminate clock timing signals that enable the microgrid to maintain the nominal system frequency. Small signal eigenvalue analysis of a Multi-inverter Microgrid system near the steady-state operating point is presented to evaluate the system stability. Moreover, unlike traditional droop-based methods, the isochronous strategy lends itself to analytical guarantees which are developed in the article. Furthermore, the effect of delays in receiving GPS clock signals by an inverter is experimentally characterized and an inverter isolation mechanism is proposed that disconnects inverters facing large GPS communication delays. Hardware experiments on an 1.2 kVA-prototype and controller-hardware-in-the-loop validation on the CIGRE distribution network are conducted to demonstrate the effectiveness of the proposed architecture towards active and reactive power sharing between inverters with load scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Time-Disciplined Non-PLL Active Synchronization for Grid-Forming Inverters: Preprint

Grid Forming Inverters (GFMIs) are a critical component of the future Grid. One major challenge with GFMIs is synchronization. Currently, most research in GFMI synchronization is focused around specific transition types but this is only a subcategory of the possible events facing GFMIs. In this paper, we propose categorizing all possible synchronization events into four categories: (1) Initial Grid Synchronization, (2) Ride-Through, (3) Blackstart Coordination, (4) Grid Reconnection Coordination. By categorizing events, we can better compare and integrate different control strategies under specific test conditions as demonstrated in simulation. This paper’s framework helps guide GFMI primary-level control design to further research towards the 100% inverter-dominant Grid.

blackstart↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

Restoring Critical Loads In Resilient Distribution Systems using A Curriculum Learned Controller

In this paper, we propose a curriculum learned reinforcement learning (RL) controller to facilitate distribution system critical load restoration (CLR), leveraging RL's fast online response and its outstanding optimal sequential control capability. Like many grid control problems, CLR is complicated due to the large control action space and renewable uncertainty in a heavily constrained non-linear environment with strong intertemporal dependency. The nature of the problem oftentimes causes the RL policy to converge to a poor-performing local optimum if learned directly. To overcome this, we design a two-stage curriculum in which the RL agent will learn generation control and load restoration decision under different scenarios progressively. Via curriculum learning, the trained RL controller is expected to achieve a better control performance, with critical loads restored as rapidly and reliably as possible. Using the IEEE 13-bus test system, we illustrate the performance of the RL controller trained by the proposed curriculum-based method.

curriculum learning↗

Incentive-Based Control and Coordination of Distributed Energy Resources

Higher penetration of renewable generation will increase the demand for adequate (and cost-effective) controllable resources on the grid that can mitigate and contain contingencies locally before they cause a network-wide collapse. This report details a scalable hierarchical control strategy for coordinating a vast number of heterogeneous distributed energy resources (DERs) in order to provide three ancillary grid services: frequency response, regulation, and ramping reserve. The control architecture consists of 1) a Distribution Reliability Coordinator (DRC), which allocates resource responses based on their declared flexibility, 2) aggregator controllers, which control a collection of DERs, and finally, 3) DER controllers at the individual devices. Test results are provided showing scalable performance on thousands of simulated residential DERs (air conditioners and water heaters) as well as results of a hardware-in-the-loop demonstration of commercial HVAC and microgrid equipment providing real responses in coordination with a grid simulation. Technology commercialization barriers and strategy is also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Safety Filter Design for Grid-Forming Inverters

Unlike conventional generators, inverter-based generation are fundamentally incapable of providing rotational inertia. While grid-forming inverters alleviate some of that problem by synthesizing small inertia via feedback control, additional control mechanisms are needed to ensure safety and security during transients. In this paper, we propose novel real-time safety-constrained feedback controllers (``safety filters'') for droop-based (grid-forming) inverters to ensure transient security of the grid. The safety filter acts as a buffer between the network operational layer and the inverter-control layer, and only lets those dispatch control signals pass to the inverter droop-controller, which are guaranteed to not violate the safety specifications (frequency, voltage, current limits). Using a distributed barrier certificates method, we construct sector-like conditions on the control policies, which guarantee the satisfaction of transient safety specifications. Sum-of-square programming is used to synthesize the safety filters. Numerical simulation results are provided to illustrate the performance of the proposed filter on inverter-based microgrids.

Kundu, Soumya↗

Interactive Buildings: A Review

Buildings are widely regarded as potential sources for demand flexibility. The flexibility of thermal and electric load in buildings is a result of their interactive nature and its impact on the building’s performance. In this paper, the interaction of a building with the three interaction counterparts of the physical environment, civil infrastructure networks and other buildings is investigated. The literature review presents a wide variety of pathways of interaction and their associated potential impacts on building performance metrics such as net energy use, emissions, occupant comfort and operational cost. It is demonstrated that all of these counterparts of interaction should be considered to harness the flexibility potential of the buildings while maintaining other buildings performance metrics at a desired level. Juxtaposed with the upside potential for providing demand flexibility, numerous implementation challenges are identified that are associated with the evaluation and financial valuation of the capacity for demand flexibility, the aggregated flexibility potential, as well as the control and communication to facilitate the interactions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intra-microgrid communication architecture

A microgrid according to an exemplary aspect of the present disclosure includes, among other things, a plurality of intelligent electronic devices configured to communicate directly with one another in a first language. Each of the intelligent electronic devices includes a controller and a gateway. The gateway is configured to convert incoming messages from the first language to a second language native to the controller. The first language is different than the second language. A method is also disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Agent Safe Policy Learning for Power Management of Networked Microgrids

This paper presents a supervised multi-agent safe policy learning (SMAS-PL) method for optimal power management of networked microgrids (MGs) in distribution systems. While unconstrained reinforcement learning (RL) algorithms are black-box decision models that could fail to satisfy grid operational constraints, our proposed method considers AC power flow equations and other operational limits. Accordingly, the training process employs the gradient information of operational constraints to ensure that the optimal control policy functions generate safe and feasible decisions. Furthermore, we have developed a distributed consensus-based optimization approach to train the agents’ policy functions while maintaining MGs’ privacy and data ownership boundaries. After training, the learned optimal policy functions can be safely used by the MGs to dispatch their local resources, without the need to solve a complex optimization problem from scratch. Lastly, numerical experiments have been devised to verify the performance of the proposed method.

, policy gradient↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Advanced control techniques for modern inertia based inverters

In this research three artificial intelligent (AI)-based techniques are proposed to regulate the voltage and frequency of a grid-connected inverter. The increase in the penetration of renewable energy sources (RESs) into the power grid has led to the increase in the penetration of fast-responding inertia-less power converters. The increase in the penetration of these power electronics converters changes the nature of the conventional grid, in which the existing kinetic inertia in the rotating parts of the enormous generators plays a vital role. The concept of virtual inertia control scheme is proposed to make the behavior of grid connected inverters more similar to the synchronous generators, by mimicking the mechanical behavior of a synchronous generator. Conventional control techniques lack to perform optimally in nonlinear, uncertain, inaccurate power grids. Besides, the decoupled control assumption in conventional VSGs makes them nonoptimal in resistive grids. The neural network predictive controller, the heuristic dynamic programming, and the dual heuristic dynamic programming techniques are presented in this research to overcome the draw backs of conventional VSGs. The nonlinear characteristics of neural networks, and the online training enable the proposed methods to perform as robust and optimal controllers. The simulation and the experimental laboratory prototype results are provided to demonstrate the effectiveness of the proposed techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗