Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muon System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Structural Design and Analysis for a Double-Band Cold Mass Support of the MICE Coupling Magnet

The cooling channel of Muon Ionization Cooling Experiment (MICE) consists of eighteen superconducting solenoid coils, which are magnetically hooked together. A pair ofcoupling magnets operating at 4 K is applied to produce up to .6 T magnetic field on the magnet centerline to keep muon beam within the RF cavity windows. The peak magnetic force on the coupling magnet from other magnets in the MICE channel is up to 500 kN inlongitudinal direction, and the requirements for magnet center and axis azimuthal angle at 4 K are stringent. A self-centered double-band cold mass support system with intermediatethermal interruption is applied for the coupling magnet. The physical center of the magnet does not change as it is cooled down from 300 K to 4.2 K with this support system. In this paper the design parameters of the support system are discussed. The integral analysis of the support system using FEA method was carried out to etermine the tension forces in bands when various loads are applied. The magnet centre displacement and concentricity deviation form the axis of the warm bore are obtained, and the peak tension in support bands is also determined according to the simulation results.

42 ENGINEERING↗

Measurement of the Higgs boson mass in the H → ZZ*→ 4ℓ decay channel using 139 fb –1 of s = 13 TeV pp collisions recorded by the ATLAS detector at the LHC

The mass of the Higgs boson is measured in the H→ZZ * →4ℓ decay channel. The analysis uses proton–proton collision data from the Large Hadron Collider at a centre-of-mass energy of 13 TeV recorded by the ATLAS detector between 2015 and 2018, corresponding to an integrated luminosity of 139 fb –1 . The measured value of the Higgs boson mass is 124.99 ± 0.18(stat.) ± 0.04(syst.) GeV. In final states with muons, this measurement benefits from an improved momentum-scale calibration relative to that adopted in previous publications. The measurement also employs an analytic model that takes into account the invariant-mass resolution of the four-lepton system on a per-event basis and the output of a deep neural network discriminating signal from background events. This measurement is combined with the corresponding measurement using 7 and 8 TeV pp collision data, resulting in a Higgs boson mass of 124.94 ± 0.17(stat.) ± 0.03(syst.) GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Participation of JINR in the CDF Experiment

Participation of a Joint Institute for Nuclear Research (JINR) team in the research program at the Tevatron at Fermilab is described. In their work on the upgraded CDF Run II detector, the emphasis was placed on top quark physics. The JINR team was fully engaged in the data analysis of the CDF experiment, particularly, in measuring the top quark mass in the dilepton and lepton-jet modes, in measuring the top quark charge, and in searching for the Higgs boson. The JINR team made a decisive contribution to the operation of the scintillation counter subsystem of the CDF muon trigger, to the trigger based on the vertex silicon detector for selection of events with secondary vertices and to the preshower detector of the electromagnetic calorimeter. The team was involved in the construction, upgrading, and operation of the system of scintillation counters and developed a system for the online monitoring of their parameters to ensure their effective operation in Run II. The work of the JINR researchers was highly appreciated by the international CDF collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low Cost High Efficiency Magnetrons for Accelerator Applications

High efficiency, low cost RF sources are required for proton, ion, and muon accelerators. These sources must be compact and provide precise control of the output power and phase. Currently only large, expensive klystrons can provide this performance. Calabazas Creek Research Inc. proposes to develop a phase locked magnetron-based system that has phase and amplitude control via a low power amplifier. The system uses phase modulation to control the RF power. The efficiency can exceed 80% and the cost is expected to be less than $3/Watt, significantly lower than other high power amplifiers. CCR originally proposed to develop a magnetron with a grid for control of phase and amplitude. Detailed simulations showed that this was not a promising approach. The grid was found to be viable only in magnetrons with low duty cycle, and amplitude control was demonstrated; but the grid was found to be not effective for phase locking. Attention was turned to a concept from Fermilab, which is very promising for both amplitude and phase control and does not require a grid. CCR will develop an RF system providing phase and amplitude control of a 100 kW peak, 10 kW average 1.3 GHz magnetron. Procedures and techniques will be applicable to design of systems at other frequencies and power levels. The program will include development of the magnetron and locking electronics. The system will be tested at Fermilab. Commercial Applications and Other Benefits Magnetrons can provide high levels of RF power at very high efficiency at low cost. As oscillators, however, their applications are limited. Magnetrons with more precise control of the output power and control of the phase could find wide application in accelerators and colliders. They would also provide improved performance for high resolution radar.

43 PARTICLE ACCELERATORS↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗

The detector system of the Daya Bay reactor neutrino experiment

The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of ν¯e oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of sin 2 2θ 13 and the effective mass splitting Δm 2 ee . The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world's most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes, the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors’ baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This study describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise Measurement of the e{sup +}e{sup -}->pi{sup +}pi{sup -}(gamma) Cross Section with the Initial State Radiation Method at BABAR

A precise measurement of the cross section of the process e{sup +}e{sup -}->pi{sup +}pi{sup -}(gamma) from threshold to an energy of 3 GeV is obtained with the initial state radiation (ISR) method using 232 fb{sup -1} of data collected with the BABAR detector at e{sup +}e{sup -} center-of-mass energies near 10.6 GeV. The ISR luminosity is determined from a study of the leptonic process e{sup +}e{sup -}->mu{sup +}mu{sup -}gamma(gamma). The leading-order hadronic contribution to the muon magnetic anomaly calculated using the pipi cross section measured from threshold to 1.8 GeV is (514.1+-2.2(stat)+-3.1(syst))x10{sup -10}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for lepton flavor-violating decay modes B 0 → K* 0 τ ± ℓ ∓ (ℓ = e, μ) with hadronic B-tagging at Belle and Belle II

We present the results of a search for the charged-lepton-flavor violating decays B 0 → K *0 τ ± ℓ ∓ , where ℓ ∓ is either an electron or a muon. The results are based on 365 fb −1 and 711 fb −1 datasets collected with the Belle II and Belle detectors, respectively. We use an exclusive hadronic B-tagging technique, and search for a signal decay in the system recoiling against a fully reconstructed B meson. We find no evidence for B 0 → K* 0 τ ± ℓ ∓ decays and set upper limits on the branching fractions in the range of (2.9–6.4)×10 −5 at 90% confidence level.

B physics↗

Measurement of the top-quark pole mass in dileptonic $t\overline{t}$ + 1-jet events at $\sqrt{s}=13$ TeV with the ATLAS experiment

A measurement of the top-quark pole mass $m$$^{pole}_{t}$ is presented in $t\bar{t}$ events with an additional jet, $t\bar{t}$+ 1-jet, produced in pp collisions at $\sqrt{s} = 13 TeV. The data sample, recorded with the ATLAS experiment during Run 2 of the LHC, corresponds to an integrated luminosity of 140 fb −1 . Events with one electron and one muon of opposite electric charge in the final state are selected to measure the $t\bar{t}$ + 1-jet differential cross-section as a function of the inverse of the invariant mass of the $t\bar{t}$ + 1-jet system. Iterative Bayesian Unfolding is used to correct the data to enable comparison with fixed-order calculations at next-to-leading-order accuracy in the strong coupling. The process pp → $t\bar{t}$j(2 → 3), where top quarks are taken as stable particles, and the process pp → $b\bar{b}$l + vl – $\overline{ν}$j (2 → 7), which includes top-quark decays to the dilepton final state and off-shell effects, are considered. The top-quark mass is extracted using a χ 2 fit of the unfolded normalized differential cross-section distribution. The results obtained with the 2 → 3 and 2 → 7 calculations are compatible within theoretical uncertainties, providing an important consistency check.

Hadron-Hadron Scattering↗

Report from the Inaugural Meeting on the Opportunities at the SEEMS Facility June 11-12, 2019

The Inaugural Meeting on the Opportunities at the Single Event Effects—Muon Spectroscopy (SEEMS) facility was held June 11–12, 2019, at Oak Ridge National Laboratory (ORNL). Capabilities of the SEEMS facility concept were reviewed, with emphasis on particle beams for single event effects (SEE) testing of electronic devices (integrated circuits) and systems—a topic of growing interest and concern in aerospace avionics, satellites, supercomputing, autonomous cars, unmanned aerial vehicles and more. Participants from these industries and their regulators attended. A clear consensus on the growing and urgent need for SEE test capabilities like those offered by SEEMS was expressed. Subsequent to the meeting, letters of support for SEEMS were sent by The Boeing Company and Honeywell to the ORNL Laboratory Director, Thomas Zacharia.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data vs. MC Comparison of Light Signal from Cosmic Rays in the ICARUS Detectors

Currently, the ICARUS-T600 liquid argon TPC is collecting data exposed to Booster Neutrino and Numi off-axis beams within the SBN program at Fermilab. A light detection system, based on PMTs deployed behind the TPC wire chambers, is in place to detect vacuum ultraviolet photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its operations at shallow depths, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates. This contribution will primarily focus on the comparative study (data vs. MC) of light signal of cosmic muons to validate the light emulation.

43 PARTICLE ACCELERATORS↗

AC Dipole Requirements for Beam Extinction for the Fermilab Mu2e Experiment

Mu2e experiment is a particle physics experiment which studies the muon-to-electron conversion without producing neutrinos. The experiment has very strict limits on the unwanted proton beam between pulses, so an extinction process to eliminate the unwanted beam is needed. The goal of our study is to simulate an extinction system with AC dipoles and a collimator and verify the 10-10 extinction requirement is fulfilled. We also analyze several sources of error to investigate the stability of our system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MICE: The International Muon Ionization Cooling Experiment: Phase Space Cooling Measurement

MICE is an experimental demonstration of muon ionization cooling using a section of an ionization cooling channel and a muon beam. The muons are produced by the decay of pions from a target dipping into the ISIS proton beam at Rutherford Appleton Laboratory (RAL). The channel includes liquid-hydrogen absorbers providing transverse and longitudinal momentum loss and high-gradient radiofrequency (RF) cavities for longitudinal reacceleration, all packed into a solenoidal magnetic channel. MICE will reduce the beam transverse emittance by about 10% for muon momenta between 140 and 240 MeV/c. Time-of-flight (TOF) counters, threshold Cherenkov counters, and a calorimeter will identify background electrons and pions. Spectrometers before and after the cooling section will measure the beam transmission and input and output emittances with an absolute precision of 0.1%.

43 PARTICLE ACCELERATORS↗

Pulse Shape Discrimination study with Gd loaded liquid scintillator for reactor neutrino monitoring

Recently, technique of Gadolinium loaded liquid scintillator (Gd-LS) for reactor neutrino oscillation experiments has attracted attention as a monitor of reactor operation and 'nuclear Gain (GA)' for IAEA safeguards. For the practical use, R and D of the 1 ton class compact detector, which is measurable above ground, is necessary. Especially, it is important to reduce much amount of fast neutron background induced by cosmic muons with data analysis for the measurement above ground. We developed a prototype of the Gd-LS detector with 200 L of the target volume, which has Pulse Shape Discrimination (PSD) ability for the fast neutron reduction with data analysis. Usually, it is well known that it is difficult to keep high fast neutron reduction power of PSD with the large volume size such as the neutrino reactor monitor. We evaluated the PSD ability of our prototype with real fast neutrons induced by the muons in our laboratory above ground, and we could confirm to keep the high fast neutron reduction power with even our large detector size. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Horn Location Sensors (HLS) for LBNF

The Long-Baseline Neutrino Facility (LBNF) will deliver the world's most powerful muon neutrino beam to the Deep Underground Neutrino Experiment (DUNE), initially operating at 1.2 MW and upgradeable to 2.4 MW. Ensuring the accurate direction of this beam is critical for DUNE's precision goals. This talk introduces the Horn Location Sensors (HLS) system, designed to provide precise, relative measurements of the focusing horns, targets, and beam position monitors in the neutrino beamline. The HLS system employs high-precision FSI-based hydrostatic leveling sensors to track vertical motion and tilt, achieving precision on the order of 0.1 mm. Built for minimal maintenance in radioactive environments, the HLS system ensures precise alignment of beamline components during high-power operations. This system is essential for maintaining beam accuracy and enhancing DUNE's scientific performance.

43 PARTICLE ACCELERATORS↗

Large scale SiPM testing for the Cosmic Muon Veto detector

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The extruded plastic scintillators will be embedded with wavelength shifting (WLS) fibres to absorb scintillating photons and propgate the re-emitted photons to the silicon-photomultipliers for the electronic signals. The CMV detector will require 760 extruded plastic scintillators to shield the mini-ICAL detector, and will require 3040 SiPMs for the readout. The design goal for the cosmic muon veto efficiency of the CMV is $>$99.99\% and fake veto rate less than 10$^{-5}$. Hence, every SiPM used in the detector needs to be characterised to satisfy the design goal of the CMV. For this, a large-scale testing system was developed, using an LED driver, to measure the gain and noise rate of each SiPM, and thus determine it's breakdown voltage ($V_{br}$) and optimum operating overvoltage ($V_{ov}$).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tau-sneutrino next-to-lightest supersymmetric particle and multilepton signatures at the LHC

In models with gravitino as the lightest supersymmetric particle (LSP), the next-to-lightest supersymmetric particle (NLSP) can have a long lifetime and appear stable in collider experiments. We study the leptonic signatures of such a scenario with tau sneutrino as the NLSP, which is realized in the non-universal Higgs masses (NUHM) scenario. We focus on an interesting trilepton signature with two like-sign taus and an electron or a muon of the opposite sign. The neutralinos and charginos are quite heavy in the model considered, and the trilepton signal comes mostly from the slepton-sneutrino production. We identify the relevant backgrounds, taking into account tau decays, and devise a set of cuts to optimize this trilepton signal. We simulate signal and backgrounds at the Large Hadron Collider (LHC) with 14 TeV center-of-mass energy. Although the sleptons in this model are relatively light, O(100 GeV), discovery is more demanding compared to typical neutralino LSP scenarios. The trilepton signal requires a large amount of accumulated data, at least {approx}80 fb{sup -1}, at the center-of-mass (c.m.) energy of 14 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic properties of the chemically delithiated Li{sub x}Mn{sub 2}O{sub 4} with 0.07{<=}x{<=}1

Magnetism for the Li{sub x}Mn{sub 2}O{sub 4} samples with 0.07{<=}x{<=}1, which are prepared by a chemical reaction in HNO{sub 3} solution, is investigated by direct current susceptibility ({chi}) and muon-spin rotation/relaxation ({mu}SR) measurements. The effective magnetic moment ({mu}{sub eff}) of Mn ions decreases monotonically with decreasing x, indicating that Mn{sup 3+} ions with S=2 (t{sub 2g}{sup 3}e{sub g}{sup 1}) are oxidized to Mn{sup 4+} ions with S=3/2 (t{sub 2g}{sup 3}) with decreasing x. On the other hand, as x decreases from 1 to 0.6, the Curie-Weiss temperature ({Theta}{sub p}) increases monotonically from {approx}-260 to -100 K, and then levels off to -100 K with further decreasing x. This indicates that the antiferromagnetic interaction is dominant in the whole x range. For the x=0.48 sample, the temperature dependence of {chi} in field-cooling mode clearly deviates from that in zero-field-cooling mode below {approx}63 K (=T{sub m}). Furthermore, the hysteresis loop is observed in the magnetization vs. field curve at 5 K. Since the zero-field {mu}SR spectrum is well fitted by a strongly damped oscillation function, the Mn moments for the x=0.48 sample are in a highly disordered fashion down to the lowest temperature measured. -- Graphical abstract: Magnetic phase diagram of the chemically delithiated spinel Li{sub x}Mn{sub 2}O{sub 4} determined by magnetic susceptibility ({chi}) and muon spin rotation/relaxation ({mu}SR) measurements. Display Omitted Highlights: {yields} Magnetic properties of the chemically delithiated Li{sub x}Mn{sub 2}O{sub 4} samples are investigated. {yields} The antiferromagnetic interaction is dominant in the whole x range. {yields} All the Li{sub x}Mn{sub 2}O{sub 4} samples show a magnetic transition below T{sub m}. {yields} The remanent magnetization vs. x curve exhibits a maximum at x=0.48. {yields} The x=0.48 sample is in a highly disordered magnetic state even at 1.8 K.

36 MATERIALS SCIENCE↗